• Title/Summary/Keyword: Counter Facility

Search Result 51, Processing Time 0.035 seconds

The Practical Simplified Equation for Settlement Evaluation of Counter Facility in Soft Ground Centering on Rubble Mound (연약지반에 설치된 항만 외곽시설의 안전점검을 위한 침하 평가 간편식 제안 - 사석경사제 중심으로)

  • Kim, Yong-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.6
    • /
    • pp.317-324
    • /
    • 2020
  • In this study, a simplified equation for settlement evaluation suitable for the special conditions of a counter facility is suggested. Recently, counter facilities, especially breakwaters, are constructed on soft ground in distant seas as new-port development projects. A counter facility that resists the external forces by self-weight settles easily when constructed on soft ground. Settlement in a counter facility and breakwater is not an important factor for maintenance than a land facility. On the other hand, the current settlement evaluation criteria are excessive for conducting a safety inspection. A settlement evaluation from a safety inspection followed by "Detailed Guidelines for a safety inspection on a counter facility" is used. A simplified equation was proposed to calculate the maximum settlement by applying the allowable residual settlement or settlement stability evaluation results. The suitability of the simplified equation was assessed compared to the assessed rating from the settlement survey results. The proposed simplified equation showed that the settlement evaluation rating had been upgraded. The proposed simplified equation is expected to be used to evaluate the practical structural stability and functional performance.

Development of Particle Counter with wireless FMS (무선 FMS를 지원하는 초미세 입자 계수기 개발)

  • Ku, Ja-Yl;Jun, Sung-Don
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2010.07a
    • /
    • pp.63-66
    • /
    • 2010
  • 기존의 입자계수기(Particle Counter)는 0.3um의 최소 인식 크기와 샘플링 유량이 2.83 lpm을 갖는다. 본 논문에서는 0.1um의 최소 인식 크기와 샘플링 유량이 28.3lpm과 50lpm을 갖는 입자 계수기를 개발하였다. 이와 함께 온도, 습도, 정전기를 실시간으로 측정하여, 이를 무선 인터페이스를 통해서 모니터링 프로그램과 연동, DB화하여 크린룸 현장의 환경을 실시간으로 유지 관리하도록 하였다.

  • PDF

Research about a multifunction high-speed counter implementation which uses FPGA (FPGA를 이용한 다기능 고속 카운터 구현에 관한 연구)

  • Lee, Do-Hyang;Yang, Oh
    • Proceedings of the KIEE Conference
    • /
    • 2003.07d
    • /
    • pp.2112-2114
    • /
    • 2003
  • In this paper, We used FPGA which was high speed counter implementation. It was Counting accurately rather fast so that there were we as a counter facility of the pulse implemented. We constructed wide environment rather because we used H8/3672 with FPGA. This FPGA was sythesized by A54SX72A. FPGA programmed by VHDL for a 208pin PQFP package. The measurement the pulse is possible though it peels off a maximum 200kHz. There is used at a stopping action movement and control of the body.

  • PDF

The Effect of Gap Size on Counter Current Flow Limitation Phenomena in Narrow Annular Gaps with Large Diameter

  • Jeong, Ji-Hwan;Lee, Seung-Jin;Park, Rae-Joon;Kim, Sang-Baek
    • Nuclear Engineering and Technology
    • /
    • v.34 no.4
    • /
    • pp.396-405
    • /
    • 2002
  • An experimental study on counter-current flow limitation phenomena in narrow annular passages was carried out The gap sizes tested were 1, 2 and 3 mm. This is very small compared with the outer diameter of the annular passage, 500 mm. It was visually observed that a CCFL might occur in some part of the periphery while the other part is remained in a counter current flow pattern. That is, non-uniform behaviour of fluids due 4o a 2-dimensional effect appear in a large diameter facility. Because of this non-uniformity, a CCFL is defined in the present work as the situation where net water accumulation is sustained. That is, some amount of water should not be allowed to penetrate the gap and accumulate over the gap at CCFL criterion. The measured data are presented in the form of Wallis'type correlation with characteristic length of gap size. It was found that the present correlation is in good agreement with other empirical correlation based on measurements whose test section diameter is close and the gap size is much larger than that of the present test section.

A Study on the evaluation of the auditory guide facility under emergency situation (비상시 청각형 유도시설의 유도성능 평가에 관한 연구)

  • Na, Wook-Jung;Jeon, Gyu-Yeob;Hong, Won-Hwa
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1205-1208
    • /
    • 2006
  • Today, our city structure is being complicated from the development of industry. Invisible losses, life and fortune loss caused by arson is embossed in our society. The preparation of counter plan about increasing factors of fire damage is not easy. With respect to mankind life, however, it is very important. Therefore, the focus of this research examine refuge degree in each smoke density level when a fire break out in the space. I evaluated auditory guide facility thorough real scale test. In this thesis, I will propose the efficient refuge deriving facilities.

  • PDF

Development of 4-Channel Particle Counter based on bluetooth Supporting FMS (FMS를 지원하는 블루투스 기반의 4-채널 미세 입자 계수기 개발)

  • Ohm, Woo-Yong;Ku, Ja-Yl;Park, Sung-Wook
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.3
    • /
    • pp.185-193
    • /
    • 2014
  • In this paper, we developed a 4-channel particle counter for measuring particles, temperature, humidity in production facilities of clean-room environment, and the measured data can be transmitted via bluetooth. To measure the particle size ranging 0.3um~5um, we designed optical lens, particle detection chamber and multi-channel particle detection circuit. And we also developed a FMS program for real-time monitoring of measuring data, which resulted in the stable operation.

Using Behavior of Corridor and Lounge at the Residence Floor in Skilled Nursing Facilities for the Elderly (노인전문요양시설 거주층의 복도 및 휴게홀 이용행태)

  • Lee Min-Ah;Ryu Ok-Soon
    • Journal of the Korean Home Economics Association
    • /
    • v.42 no.11
    • /
    • pp.31-45
    • /
    • 2004
  • The purpose of this study was to provide basic information about the facility planning to reduce elderly isolation and to improve their rehabilitation ability. Four re%archers observed the using behavior of the elderly residents in the corridor and lounge of 5 facilities. The results of the study were as follows. The using rate of the lounge wis higher than that of the corridor since most of the elderly were controlled by the staffs at the lounge. The facility could decrease the crowd of the lounge by arranging the sofa at the corridor-especially surrounding the atrium. The use rate in the lounge was very dependent on the time of the day, because its use was influenced mainly by daily schedule, and this resoled in it being largely inactive most of the time. A counter plan is needed to encourage natural interaction among the elderly. Individual or small group activities are required in addition to the regular programs. Since the furniture arrangements_(sofas and tables) at the corridor could induce elderly isolation and inactivity, various equipments should be arranged for the self-controlled activities. The indirect participation in the regular activities, which are usually conducted in the lounge, should also be considered in the corridor so that the elderly could observe them at any places.

An experimental study on the performance of a window system air-conditioner using R407C and R410B (R407C 및 R410B 적용 창문형 에어컨의 성능에 관한 실험적 연구)

  • Kim, M.H.;Shin, J.S.;Kim, K.J.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.4
    • /
    • pp.536-544
    • /
    • 1997
  • This study presents test results of a residential window system air-conditioner using R22 and two potential alternative refrigerants, R407C and R410B. A series of performance tests was performed for the basic and liquid-suction heat exchange cycle in a psychrometric calorimeter test facility. For R407C, the same rotary compressor was used as in the R22 system. However, compressor for the R410B system was modified to provide the similar cooling capacity. The evaporator circuit was changed to get a counter-cross flow heat exchanger to take advantage of zeotropic mixture's temperature glide, and liquid-line suction-line heat exchange cycle was also considered to improve the performance of the system. Test results were compared to those for the basic R22 system.

  • PDF

The Characteristics for BNCT facility in Hanaro Reactor

  • Soheigh Suh;Lee, Dong-Han;Ji, Young-Hoon;Lee, Dong-Hoon;Yoo, Seong-Yul;Rhee, Chang-Hun;Rhee, Soo-Yong;Jun, Byung-Jin
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.161-163
    • /
    • 2002
  • The BNCT(Boron Neutron Capture Therapy) facility has been developed in Hanaro(High-flux Advanced Neutron Application Reactor), a research reactor of Korea Atomic Energy Research Institute. A typical tangenial beam port is utilized with this BNCT facility. Thermal neutrons can be penetrated within the limits of the possible maximum instead of being filtered fast neutrons and gamma rays as much as possible using the silicon and bismuth single crystals. In addition to, the liquid nitrogen (LN$_2$) is used to cool down the silicon and bismuth single crystals for the increase of the penetrated thermal neutron flux. Neutron beams for BNCT are shielded using the water shutter. The water shutter was designed and manufactured not to interfere with any other subsystem of Hanaro when the BNCT facility is operated. Also, it is replaced with conventional beam port plug in order to cut off helium gas leakage in the beam port. A circular collimator, composed of $\^$6/Li$_2$CO$_3$ and polyethylene compounds, is installed at the irradiation position. The measured neutron flux with 24 MW reactor power using the Au-198 activation analysis method is 8.3${\times}$10$\^$8/ n/cm$^2$ s at the collimator, exit point of neutron beams. Flatness of neutron beams is proven to ${\pm}$ 6.8% at 97 mm collimator. According to the result of acceptance tests of the water shutter, the filling time of water is about 190 seconds and drainage time of it is about 270 seconds. The radiation leakages in the irradiation room are analyzed to near the background level for neutron and 12 mSv/hr in the maximum for gamma by using BF$_3$ proportional counter and GM counter respectively. Therefore, it is verified that the neutron beams from BNCT facility in Hanaro will be enough to utilize for the purpose of clinical and pre-clinical experiment.

  • PDF

An Experimental Study on the Freezing Temperature of Admixture Agent for Concrete (콘크리트용 혼화제의 동결온도에 관한 실험적 연구)

  • 한경익;이건철;이진규;윤기원;한천구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1996.04a
    • /
    • pp.48-51
    • /
    • 1996
  • Recently, frost damage of storage tank for admixture agent caused by low temperature in winter and quality deterioration of admixture agent ofen happened. But, many problems are caused because of no applicable regulations of admixture agent facility and so on. Therefore, this study presents the reference data about using and quality control of admixture agent in practice and the judgement data about working out a counter plan of suitable heat insulation of injecion equipment of admixture agent exposed at outside in winter by measuring the freezing point of admixture agent for concrete.

  • PDF