• Title/Summary/Keyword: Correction Image

Search Result 1,221, Processing Time 0.032 seconds

A Method to Enhance the Recognition Rate of Marker Images in Augmented Reality (증강현실 마커 이미지의 인식률 개선 방안)

  • Park, Chan;Lee, Wan-Bok
    • Journal of Convergence for Information Technology
    • /
    • v.12 no.1
    • /
    • pp.1-6
    • /
    • 2022
  • As augmented reality technology becomes more common and prevelant, marker-based AR contents are applied in various ways. However AR contents are still hardly utilized due to the low recognition rate of marker images. In order to increase the recognition rate of AR marker images, this paper experiment and analyzed how much the recognition rate of markers could be improved when image correction and design changes was applied. The experimental result shows that the image correction task could significantly improve the number of image characteristics and the recognition grade if the image was modified in a way its saturation value is increased. Moreover, the recognition rate was improved even more when regular pattern design was added to the original marker image. In conclusion, it was possible to make the marker well recognized through proper correction of the image and additional process of pattern design in the process of producing the marker image.

Automatic Jitter Evaluation Method from Video using Optical Flow (Optical Flow를 사용한 동영상의 흔들림 자동 평가 방법)

  • Baek, Sang Hyune;Hwang, WonJun
    • Journal of Korea Multimedia Society
    • /
    • v.20 no.8
    • /
    • pp.1236-1247
    • /
    • 2017
  • In this paper, we propose a method for evaluating the uncomfortable shaking in the video. When you shoot a video using a handheld device, such as a smartphone, most of the video contains unwanted shake. Most of these fluctuations are caused by hand tremors that occurred during shooting, and many methods for correcting them automatically have been proposed. It is necessary to evaluate the shake correction performance in order to compare the proposed shake correction methods. However, since there is no standardized performance evaluation method, a correction performance evaluation method is proposed for each shake correction method. Therefore, it is difficult to make objective comparison of shake correction method. In this paper, we propose a method for objectively evaluating video shake. Automatically analyze the video to find out how much tremors are included in the video and how much the tremors are concentrated at a specific time. In order to measure the shaking index, we proposed jitter modeling. We applied the algorithm implemented by Optical Flow to the real video to automatically measure shaking frequency. Finally, we analyzed how the shaking indices appeared after applying three different image stabilization methods to nine sample videos.

Analysis of Noise Power Spectrum According to Flat-Field Correction in Digital Radiography (디지털 의료영상에서 Flat-Field 보정에 따른 Noise Power Spectrum 분석)

  • Lee, Meena;Kwon, Soonmu;Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.3
    • /
    • pp.227-232
    • /
    • 2013
  • The pixels used in a digital X-ray detector have different sensitivities and offset values. A non-uniform image is consequently obtained. Flat-field correction was introduced to resolve this problem and carried out image preprocessing in a digital imaging system. Nevertheless, the non-uniform images caused by several reasons have been being occasionally acquired. In this study, the non-uniform images acquired in digital imaging systems were applied to flat-field correction, and NPSs were calculated and analyzed with those images before and after correction. It was confirmed that low frequency noise were effectively eliminated.

A Non-uniform Correction Algorithm Based on Scene Nonlinear Filtering Residual Estimation

  • Hongfei Song;Kehang Zhang;Wen Tan;Fei Guo;Xinren Zhang;Wenxiao Cao
    • Current Optics and Photonics
    • /
    • v.7 no.4
    • /
    • pp.408-418
    • /
    • 2023
  • Due to the technological limitations of infrared thermography, infrared focal plane array (IFPA) imaging exhibits stripe non-uniformity, which is typically fixed pattern noise that changes over time and temperature on top of existing non-uniformities. This paper proposes a stripe non-uniformity correction algorithm based on scene-adaptive nonlinear filtering. The algorithm first uses a nonlinear filter to remove single-column non-uniformities and calculates the actual residual with respect to the original image. Then, the current residual is obtained by using the predicted residual from the previous frame and the actual residual. Finally, we adaptively calculate the gain and bias coefficients according to global motion parameters to reduce artifacts. Experimental results show that the proposed algorithm protects image edges to a certain extent, converges fast, has high quality, and effectively removes column stripes and non-uniform random noise compared to other adaptive correction algorithms.

Development of Distortion Correction Technique in Tilted Image for River Surface Velocity Measurement (하천 표면영상유속 측정을 위한 경사영상 왜곡 보정 기술 개발)

  • Kim, Hee Joung;Lee, Jun Hyeong;Yoon, Byung Man;Kim, Seo Jun
    • Ecology and Resilient Infrastructure
    • /
    • v.8 no.2
    • /
    • pp.88-96
    • /
    • 2021
  • In surface image velocimetry, a wide area of a river is photographed at an angle to measure its velocity, inevitably causing image distortion. Although a distorted image can be corrected into an orthogonal image by using 2D projective coordinate transformation and considering reference points on the same plane as the water surface, this method is limited by the uncertainty of changes in the water level in the event of a flood. Therefore, in this study, we developed a tilt image correction technique that corrects distortions in oblique images without resetting the reference points while coping with changes in the water level using the geometric relationship between the coordinates of the reference points set at a high position the camera, and the vertical distance between the water surface and the camera. Furthermore, we developed a distortion correction method to verify the corrected image, wherein we conducted a full-scale river experiment to verify the reference point transformation equation and measure the surface velocity. Based on the verification results, the proposed tilt image correction method was found to be over 97% accurate, whereas the experiment result of the surface velocity differed by approximately 4% as compared to the results calculated using the proposed method, thereby indicating high accuracy. Application of the proposed method to an image-based fixed automatic discharge measurement system can improve the accuracy of discharge measurement in the event of a flood when the water level changes rapidly.

The Comparison of Quantitative Accuracy between Energy Window-Based and CT-Based Scatter Correction Method in SPECT/CT Images (SPECT/CT 영상에서 에너지창 기반 산란보정과 CT 기반 산란보정 방법의 정량적 정확성 비교)

  • Kim, Ji-Hyeon;Lee, Joo-Young
    • Journal of radiological science and technology
    • /
    • v.45 no.2
    • /
    • pp.135-143
    • /
    • 2022
  • In SPECT image, scatter count is the cause of quantitative count error and image quality degradation. This study is to evaluate the accuracy of CT based SC(CTSC) and energy window based SC(EWSC) as the comparison with existing Non SC. SPECT/CT images were obtained after filling air in order to acquire a reference image without the influence of scatter count inside the Triple line insert phantom setting hot rod(99mTc 74.0 MBq) in the middle and each SPECT/CT image was obtained each separately after filling water instead of air in order to derive the influence of scatter count under the same conditions. For EWSC, 9 sub-energy windows were set additionally in addition to main energy window(140 keV, 20%) and then, images were acquired at the same time and five types of EWSC including DPW(dual photo-peak window)10%, DEW(dual energy window)20%, TEW(triple energy window)10%, TEW5.0%, TEW2.5% were used. Under the condition without fluctuations in primary count, total count was measured by drawing volume of interest (VOI) in the images of the two conditions and then, the ratio of scatter count of total counts was calculated as percent scatter fraction(%SF) and the count error with image filled with water was evaluated with percent normalized mean-square error(%NMSE) based on the image filled with air. Based on the image filled with air, %SF of images filled with water to which each SC method was applied is non scatter correction(NSC) 37.44, DPW 27.41, DEW 21.84, TEW10% 19.60, TEW5% 17.02, TEW2.5% 14.68, CTSC 5.57 and the scatter counts were removed the most in CTSC and %NMSE is NSC 35.80, DPW 14.28, DEW 7.81, TEW10% 5.94, TEW5% 4.21, TEW2.5% 2.96, CTSC 0.35 and the error in CTSC was found to be the lowest. In SPECT/CT images, the application of each scatter correction method used in the experiment could improve the quantitative count error caused by the influence of scatter count. In particular, CTSC showed the lowest %NMSE(=0.35) compared to existing EWSC methods, enabling relatively accurate scatter correction.

An Experimental Method for the Scatter Correction of MV Images Using Scatter to Primary Ratios (SPRs) (산란선 대 일차선비(SPR)를 이용한 MV 영상의 산란 보정을 위한 실험적 방법)

  • Jeon, Hosang;Park, Dahl;Lee, Jayeong;Nam, Jiho;Kim, Wontaek;Ki, Yongkan;Kim, Donghyun;Lee, Ju Hye;Kim, Dongwon
    • Progress in Medical Physics
    • /
    • v.25 no.3
    • /
    • pp.143-150
    • /
    • 2014
  • In general radiotherapy, mega-voltage (MV) x-ray images are widely used as the unique method to verify radio-therapeutic fields. But, the image quality of MV images is much lower than that of kilo-voltage x-ray images due to scatter interactions. Since 1990s, studies for the scatter correction have performed with digital-based MV imaging systems. In this study, a novel method for the scatter correction is suggested using scatter to primary ratio (SPR), instead of conventional methods such as digital image processing or scatter kernel calculations. We measured two MV images with and without a solid water phantom describing a patient body with given imaging conditions, and calculated un-attenuated ratios. Then, we obtained SPR distributions for the scatter correction. For experimental validation, a line-pair (LP) phantom using several Al bars and a clinical pelvis MV image was used. As the result, scatter signals of the LP phantom image were successfully reduced so that original density distribution of the phantom was restored. Moreover, image contrast values increased after SPR correction at all ROIs of the clinical image. The mean value of increases was 48%. The SPR correction method suggested in this study has high reliability because it is based on actually measured data. Also, this method can be easily adopted in clinics without additional cost. We expected that the SPR correction can be an effective method to improve the quality of MV image guided radiotherapy.

Research of Phase Correlation Method for Identifying Quantitative Similarity in Adjacent Real-time Streaming Frame

  • Cho, Yongjin;Yun, Yeji;Lee, Kyou-seung;Oh, Jong-woo;Lee, DongHoon
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.157-157
    • /
    • 2017
  • To minimize the damage by wild birds and acquire the benefits such as protection against weeds and maintenance of water content in soil, the mulching black color vinyl after seeding should be carried out. Non-contact and non-destructive methods that can continuously determine the locations are necessary. In this study, a crop position detection method was studied that uses infrared thermal image sensor to determine the cotyledon position under vinyl mulch. The moving system for acquiring image arrays has been developed for continuously detecting crop locations under plastic mulching on the field. A sliding mechanical device was developed to move the sensor, which were arranged in the form of a linear array, perpendicular to the array using a micro-controller integrated with a stepping motor. The experiments were conducted while moving 4.00 cm/s speed of the IR sensor by the rotational speed of the stepping motor based on a digital pulse width modulation signal from the micro-controller. The acquired images were calibrated with the spatial image correlation. The collected data were processed using moving averaging on interpolation to determine the frame where the variance was the smallest in resolution units of 1.02 cm. Non-linear integral interpolation was one of method for analyzing the frequency using the normalization image and then arbitrarily increasing the limited data value of $16{\times}4pixels$ in one frame. It was a method to relatively reduce the size of overlapping pixels by arbitrarily increasing the limited data value. The splitted frames into 0.1 units instead of 1 pixel can propose more than 10 times more accurate and original method than the existing correction method. The non-integral calibration method was conducted by applying the subdivision method to the pixels to find the optimal correction resolution based on the first reversed frequency. In order to find a correct resolution, the expected location of the first crop was indicated on near pixel 4 in the inversion frequency. For the most optimized resolution, the pixel was divided by 0.4 pixel instead of one pixel to find out where the lowest frequency exists.

  • PDF

Chemical Shift Artifact Correction in MREIT

  • Minhas, Atul S.;Kim, Young-Tae;Jeong, Woo-Chul;Kim, Hyung-Joong;Lee, Soo-Yeol;Woo, Eung-Je
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.6
    • /
    • pp.461-468
    • /
    • 2009
  • Magnetic resonance electrical impedance tomography (MREIT) enables us to perform high-resolution conductivity imaging of an electrically conducting object. Injecting low-frequency current through a pair of surface electrodes, we measure an induced magnetic flux density using an MRI scanner and this requires a sophisticated MR phase imaging method. Applying a conductivity image reconstruction algorithm to measured magnetic flux density data subject to multiple injection currents, we can produce multi-slice cross-sectional conductivity images. When there exists a local region of fat, the well-known chemical shift phenomenon produces misalignments of pixels in MR images. This may result in artifacts in magnetic flux density image and consequently in conductivity image. In this paper, we investigate chemical shift artifact correction in MREIT based on the well-known three-point Dixon technique. The major difference is in the fact that we must focus on the phase image in MREIT. Using three Dixon data sets, we explain how to calculate a magnetic flux density image without chemical shift artifact. We test the correction method through imaging experiments of a cheese phantom and postmortem canine head. Experimental results clearly show that the method effectively eliminates artifacts related with the chemical shift phenomenon in a reconstructed conductivity image.

Efficient Image Warping Mechanism Using Template Matching and Partial Warping (템플릿 매칭과 부분 워핑을 이용한 효율적인 원근 영상 워핑 기법)

  • Jeong, Dae-Heon;Cho, Tai-Hoon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.339-342
    • /
    • 2017
  • Geometric transform of an image is used to image correction. Ridid-Body, Simlilary transform, etc, many correction methods are exist in computer vision. Image warping is used to correction for image with perspective. To image warping I extracted 4 feature point about warping position. But It is difficult to extract 4 points accurately and warping result with these point is occurs error over 3 or 4 pixel at warping position. So I used template matching to extract 4 points correctly and selected repeatedly 2 points of 4 points because to confirm result correctly. positions of 2 points are changed in near of 3 by 3 pixel and warped each change. So I selected optimal 4 points with a error of less than 1 pixel and finally, warped image using optimal points. For this way is possible to obtain optimum result.

  • PDF