An Experimental Method for the Scatter Correction of MV Images Using Scatter to Primary Ratios (SPRs)  

Jeon, Hosang (Department of Radiation Oncology, Pusan National University Yangsan Hospital)
Park, Dahl (Department of Radiation Oncology, Pusan National University Hospital)
Lee, Jayeong (Department of Radiation Oncology, Pusan National University Yangsan Hospital)
Nam, Jiho (Department of Radiation Oncology, Pusan National University Yangsan Hospital)
Kim, Wontaek (Department of Radiation Oncology, Pusan National University School of Medicine)
Ki, Yongkan (Department of Radiation Oncology, Pusan National University Hospital)
Kim, Donghyun (Department of Radiation Oncology, Pusan National University Hospital)
Lee, Ju Hye (Department of Radiation Oncology, Pusan National University Hospital)
Kim, Dongwon (Department of Radiation Oncology, Pusan National University School of Medicine)
Publication Information
Progress in Medical Physics / v.25, no.3, 2014 , pp. 143-150 More about this Journal
Abstract
In general radiotherapy, mega-voltage (MV) x-ray images are widely used as the unique method to verify radio-therapeutic fields. But, the image quality of MV images is much lower than that of kilo-voltage x-ray images due to scatter interactions. Since 1990s, studies for the scatter correction have performed with digital-based MV imaging systems. In this study, a novel method for the scatter correction is suggested using scatter to primary ratio (SPR), instead of conventional methods such as digital image processing or scatter kernel calculations. We measured two MV images with and without a solid water phantom describing a patient body with given imaging conditions, and calculated un-attenuated ratios. Then, we obtained SPR distributions for the scatter correction. For experimental validation, a line-pair (LP) phantom using several Al bars and a clinical pelvis MV image was used. As the result, scatter signals of the LP phantom image were successfully reduced so that original density distribution of the phantom was restored. Moreover, image contrast values increased after SPR correction at all ROIs of the clinical image. The mean value of increases was 48%. The SPR correction method suggested in this study has high reliability because it is based on actually measured data. Also, this method can be easily adopted in clinics without additional cost. We expected that the SPR correction can be an effective method to improve the quality of MV image guided radiotherapy.
Keywords
Scatter to primary ratio; MV image; Scatter correction; Image guided radiotherapy;
Citations & Related Records
연도 인용수 순위
  • Reference
1 L.E. Antonuk, J. Boudry, W. Huang, D.L. McShan, E.J. Morton, J. Yorkston, M.J. Longo, R.A. Street: Demonstration of megavoltage and diagnostic x-ray imaging with hydrogenated amorphous silicon arrays. Medical physics 19(6):1455-1466 (1992)   DOI   ScienceOn
2 R.C. Gonzalez, R.E. Woods, S.L. Eddins: Digital image processing using MATLAB. 2nd ed, Gatesmark Publishing Knoxville, (2009)
3 I. Pitas: Digital image processing algorithms and applications. ed, Wiley. com, (2000)
4 L. Spies, T. Bortfeld: Analytical scatter kernels for portal imaging at 6 MV. Medical physics 28(4):553-559 (2001)   DOI
5 L. Spies, M. Ebert, B.A. Groh, B.M. Hesse, T. Bortfeld: Correction of scatter in megavoltage cone-beam CT. Physics in medicine and biology 46(3):821-833 (2001)   DOI
6 L. Spies, P.M. Evans, M. Partridge, V.N. Hansen, T. Bortfeld: Direct measurement and analytical modeling of scatter in portal imaging. Medical physics 27(3):462-471 (2000)   DOI
7 V.N. Hansen, W. Swindell, P.M. Evans: Extraction of primary signal from EPIDs using only forward convolution. Medical physics 24(9):1477-1484 (1997)   DOI
8 J.S. Maltz, B. Gangadharan, S. Bose, D.H. Hristov, B.A. Faddegon, A. Paidi, A.R. Bani-Hashemi: Algorithm for X-ray scatter, beam-hardening, and beam profile correction in diagnostic (kilovoltage) and treatment (megavoltage) cone beam CT. IEEE transactions on medical imaging 27(12):1791-1810 (2008)   DOI
9 D. Sheikh-Bagheri, D.W. Rogers: Monte Carlo calculation of nine megavoltage photon beam spectra using the BEAM code. Medical physics 29(3):391-402 (2002)   DOI   ScienceOn