• 제목/요약/키워드: Correct shielding

검색결과 9건 처리시간 0.022초

동물병원 방사선 안전관리체계에 대한 연구 (Study of Radiation Safety Management of Veterinary Hospital in Korea)

  • 채수영;최호정;이영원
    • 한국임상수의학회지
    • /
    • 제37권1호
    • /
    • pp.15-22
    • /
    • 2020
  • This study investigated the effectiveness of radiation safety rules in animal hospital and the awareness and behavior of veterinary radiation workers. With the questionnaires, the data was collected from randomly selected veterinarians in animal hospitals and animal medical imaging centers. Collected data were about radiation device, shielding device, regulations, safety management, education, knowledge, behavior and awareness. Frequency, correlation and multiple regression analysis were performed. The medical devices related with radiation in animal hospital were X-ray (59%), CT (15%), fluoroscopy (12%), mobile X-ray (12%) and others (2%). The number of people using radiation shielding device is high. The answers were low on knowing radiation related regulation and receiving radiation protection education. The group with higher knowledge and awareness shows positive correlation with safety behavior. The increase of use of the radiation related medical devices in veterinary hospital causes the increase of radiation exposure risk. This study suggests that radiation safety management system and policies need to be developed to protect radiation workers and give them correct information and consciousness.

전신 방사선치료(Total Body Irradiation, TBI)를 위한 한국인에 맞는 환자 고정장치에 관한 연구 (Development of Patient-Immobilizing Device for Total Body Irradiation (TBI))

  • 김명세
    • 한국의학물리학회지:의학물리
    • /
    • 제13권3호
    • /
    • pp.114-119
    • /
    • 2002
  • 조사 선량의 분포를 저해하지 않으면서 정확한 차폐가 가능하며, 짧은 시간 내에 쉽게 환자를 고정할 수 있으며, 치료 중에 환자가 의식을 잃는 경우에도 다치지 않고 지지될 수 있는, 한국인의 체형에 맞는 전신방사선치료를 위한 고정장치를 개발하고 그 효과를 평가하였다. 230 cm의 키, 100 kg의 체중을 가진 성인 환자도 지지될 수 있도록 지름 5 cm의 스텐레스 원형 봉을 사용하여 프레임을 제작하였고, 의자는 환자가 서 있는 상태에서 환자의 키, 몸의 두께에 맞추어 위치 조절이 가능하도록 고안하였다. 가슴부위의 전면 지지대는 1 cm 두께의 아크릴을 사용하여 지지의 기능과 차폐물의 고정 기능을 겸하게 하였고, 등면의 지지대는 1 cm 두께의 아크릴을 5 mm 두께, 3 cm 넓이의 스텐레스 스틸로 테를 둘러 환자의 지지와 엑스선 필름 카세트 고정장치를 겸하도록 고안하였으며 2개의 상부 도르래와 측면의 핸들로 쉽고 정확하게 조절할 수 있도록 하였다. 머리 고정장치는 비닐과 특수 스펀지를 사용하여 쇠약한 환자의 작은 흔들림도 방지할 수 있도록 하였다. 환자를 원하는 위치에 고정하는데 평균 4분 25초가 소요되었고 반복되는 분할조사의 검교정 필름에서 폐의 차폐물의 위치에 차이가 없었으며, 펜텀 실험과 환자치료에서 $\pm$5%의 선량차이를 보였다. 치료중 환자가 의식을 잃은 경우도 수차 있었으나 쓰러지지 않고 지지할 수 있었다.

  • PDF

다양한 Plugging 형태를 이용한 감마나이프의 선택적 빔 차폐 방법 (Selective Beam Shielding Method of Gamma-Knife Unit Using Various Plugging Patterns)

  • 장건호;임영진;신동오;최두호;홍성언;임언
    • Radiation Oncology Journal
    • /
    • 제11권2호
    • /
    • pp.439-448
    • /
    • 1993
  • Leksell 감마나이프(B-형)가 1992년 3월 경희대학교 의과대학 병원에 설치되었다. 선택적 빔 Plugging방법을 이용하여 정상 민감 조직에 대한 저선량 분포를 현저히 줄일 수 있으며, 또한 치료 부위에 더 좋은 선량 분포를 얻을 수 있다. 저선량에 대한 여러가지 선량 분포의 변화에 대한 연구를 하였으며, 사용중인 KULA프로그램의 선량 분포 곡선을 평가하기 위해 필름을 이용한 방사선량 계측을 실시하였고, RFA-3자동 밀도 측정기를 이용하여 평가하였다. 1992년 3월부터 1993년 2월까지 1년동안 100명의 환자중 17명의 환자에 선택적 빔 차폐 방법이 적용되었다. 고선량 영역에서는 측정값과 프로그램에서 제공된 선량 분포가 잘 일치하였다. 뇌하수체 선종의 치료시 치료 부위가 클 경우에는 본 연구 방법의 적용이 매우 중요시 되었으며, 반면에 치료 영역이 작을 경우에는 적절한 헬맷의 선택이 중요함을 알 수 있었다. 치료 환자의 중요 민감 장기의 방사선 선량 평가에서는 뇌간에 3~12 Gy, 시신경 교차에 3~11.2 Gy이었다. 중추신경계 영역의 최적화된 치료를 위하여 다양한 Plugging형태를 임상에 적용하는 것이 방사선에 민감한 정상 조직을 보호하기 위해 매우 중요한 인자가 됨을 알았다.

  • PDF

3축 자계 측정 시스템의 개발 (The Development of Magnetic Field Measurement System of 3 Axis)

  • 김기준
    • 한국전기전자재료학회논문지
    • /
    • 제30권4호
    • /
    • pp.253-257
    • /
    • 2017
  • Nowadays, it is increasingly important to detect whether cables are live for the operator's safety if there is a sudden power failure. It is especially hard to detect the electrical field of an underground line because of shielding. This paper on detection of live-line states in cables studied the detection characteristics of the change in the magnetic field and axis as the frequency, voltage, and distance at the same load are changed using 3 axes. A search coil type was used as a magnetic field sensor with non-contact. We found that magnetic fields decrease proportionally to the square of the distance and the decrease of rated voltage with load effected to magnetic field. The magnetic field was detected by 3-axis sensors given correct proximity, but appeared as noise components beyond a distance of 2 cm.

전산화 단층 촬영 장치를 이용한 뇌척수 조사의 치료 계획 (Computed Tomographic Simulation of Craniospinal Irradiation)

  • 이충일;김회남;오택열;황도성;박남수;계철승;김연실
    • 대한방사선치료학회지
    • /
    • 제11권1호
    • /
    • pp.53-59
    • /
    • 1999
  • The aim of this study is to improve the accuracy of field placement and junction between adjacent fields and block shielding through the use of a computed tomography(CT) simulator and virtual simulation. The information was acquired by assessment of Alderson Rando phantom image using CT simulator (I.Q. Xtra - Picker), determination of each field by virtual fluoroscopy of voxel IQ workstation AcQsim and colored critical structures that were obtained by contouring in virtual simulation. And also using a coronal, sagittal and axial view can determine the field and adjacent field gap correctly without calculation during the procedure. With the treatment planning by using the Helax TMS 4.0, the dose in the junction among the adjacent fields and the spinal cord and cribriform plate of the critical structure was evaluated by the dose volume histogram. The pilot image of coronal and sagittal view took about 2minutes and 26minutes to get 100 images. Image translation to the virtual simulation workstation took about 6minutes. Contouring a critical structure such as cribriform plate, spinal cord using a virtual fluoroscopy were eligible to determine a correct field and shielding. The process took about 20 minutes. As the result of the Helax planning, the dose distribution in adjacent field junction was ideal, and the dose level shows almost 100 percentage in the dose volume histogram of the spinal cord and cribriform plate CT simulation can get a correct therapy area due to enhancement of critical structures such as spinal cord and cribriform plate. In addition, using a Spiral CT scanner can be saved a lot of time to plan a simulation therefore this function can reduce difficulties to keep the patient position without any movements to the patient, physician and radiotherapy technician.

  • PDF

Optimization of image reconstruction method for dual-particle time-encode imager through adaptive response correction

  • Dong Zhao;Wenbao Jia;Daqian Hei;Can Cheng;Wei Cheng;Xuwen Liang;Ji Li
    • Nuclear Engineering and Technology
    • /
    • 제55권5호
    • /
    • pp.1587-1592
    • /
    • 2023
  • Time-encoded imagers (TEI) are important class of instruments to search for potential radioactive sources to prevent illicit transportation and trafficking of nuclear materials and other radioactive sources. The energy of the radiation cannot be known in advance due to the type and shielding of source is unknown in practice. However, the response function of the time-encoded imagers is related to the energy of neutrons or gamma-rays. An improved image reconstruction method based on MLEM was proposed to correct for the energy induced response difference. In this method, the count vector versus time was first smoothed. Then, the preset response function was adaptively corrected according to the measured counts. Finally, the smoothed count vector and corrected response were used in MLEM to reconstruct the source distribution. A one-dimensional dual-particle time-encode imager was developed and used to verify the improved method through imaging an Am-Be neutron source. The improvement of this method was demonstrated by the image reconstruction results. For gamma-ray and neutron images, the angular resolution improved by 17.2% and 7.0%; the contrast-to-noise ratio improved by 58.7% and 14.9%; the signal-to-noise ratio improved by 36.3% and 11.7%, respectively.

투시 검사 시 장비에 따른 환자와 시술자의 입사표면선량 연구 (Fluoroscopic the equipment study in accordance with the entrance surface dose study of patients and practitioners)

  • 양해두;홍선숙;성민숙;하동윤
    • 대한디지털의료영상학회논문지
    • /
    • 제15권2호
    • /
    • pp.13-18
    • /
    • 2013
  • Purpose : Fluoroscopy equipment, depending on the type of changes that occur in the patient's position ESD and study the patient's scatter ray of ESD Practitioners considered a comparative analysis was to evaluate the correct dose. Materials and Methods : HITACHI four overtube type TU-8000 Flat Detector and Under tube C-Arm Philips' Multi Diagnost Eleva with Flat Detector type were measured by. Each devices is a measure of the patient's esd randophantom position in tabel unfors Xi multi funtion then fixed to the abdomen fluoroscopy and 10 seconds, spot was measured three times, practitioners of the incident surface dose by considering the patient's scatter ray of the table for each device in the average human stomach 21cm thickness acrylic phantom ($25cm{\times}25cm$) Place the practitioner position after position randophantom unfors Xi multi funtion in the thyroid and stomach 1 minute by a fixed one-time fluoroscopy and measured. Results : 10 seconds and the patient perspective of the c-arm ESD 1.2 times smaller on the AP and oblique measurements were measured in the 6-13 times smaller. spot positions to changes in the measured three times on the AP of the abdomen, ESD is 18 times smaller c-arm measurements and the oblique measurement was 19-30 times smaller. And 1 minute at practitioners fluoroscopy esd in the thyroid 2.12 times the c-arm, chest 1.75 times less the dose was measured. On the AP, depending on the device, but the lack of dose difference oblique positions of the two devices depending on changes in the area due to changes in both the AP than on the dose increased, the difference in dose between the two devices, the maximum difference was approximately 27 times. Conclusion : Fluoroscopic equipment at the time of inspection in accordance with changes in dose according to the patient and the patient's positions changes, because the area of the scatter ray considering the change of dose measurements be made, and study of the equipment according to the characteristics of the efficiency and the exposure of the patient and practitioner is considered smooth study equipment manufacturers that can be done is to build the system and think that is also important. Various fluoroscopy when you check future changes in many factors of change in dose for the equipment in the laboratory system by considering the scatter ray radiation shielding for the management to take advantage of reckless undertube have been utilized as more exposure Reduction activities can help is considered as the direction.

  • PDF

방사선 중재적 시술 중 시술자의 피폭선량에 대한 연구 (A Study on Radiation Exposure Dose of Operator During Interventional Radiology Procedure)

  • 전미은;임청환;정홍량;유인규;홍동희;강병삼
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제35권3호
    • /
    • pp.219-226
    • /
    • 2012
  • 방사선 중재적 시술자들이 중재적 시술 중 잠재적인 위험을 인식하지 못하고 있다. 본 연구의 목적은 방사선 중재적 시술 중 시술자들의 피폭선량을 평가하여 이를 바탕으로 중재적 시술 중 피폭선량을 줄일 수 있는 방법의 기준안을 제안하는 것이다. 본 연구는 3개월 동안 전신선량계를 사용하여 20명의 중재적 시술자로부터 시행하는 모든 중재적 시술에서 방사선 피폭선량을 측정하였다. 방사선 중재적 시술을 시행하는 동안 납당량이 0.5 mmPb 방사선장해방어용 기구를 착용하는 것으로 평균 89.5 %의 피폭선량이 감쇄되었고, 납당량이 두꺼울수록 선량감쇄율은 증가하였다. TACE 시술을 시행하는 동안 연속투시보다 펄스투시를 선택하여 사용하는 것은 피폭선량이 평균 47.7 % 감쇄되었다. 중재적 시술자는 중재적 시술이 진행되는 동안 방사선장해방어용 기구를 착용하고, 적극적인 방사선방호 활동을 실시하여야 하며, 자신의 피폭선량에 대해 알고 있어야 한다. 그리고 피폭선량을 최소화하기 위한 자신의 위치나 장비 사용에 대해서도 알아야 한다.

강릉 지역에서 자동 전운량 장비와 GWNU 태양 복사 모델을 이용한 지표면 일사량 분석 (An Analysis of Global Solar Radiation using the GWNU Solar Radiation Model and Automated Total Cloud Cover Instrument in Gangneung Region)

  • 박혜인;조일성;김부요;지준범;이규태
    • 한국지구과학회지
    • /
    • 제38권2호
    • /
    • pp.129-140
    • /
    • 2017
  • 이 연구에서는 지표 관측 자료와 위성 자료 그리고 GWNU 단층 복사 모델을 이용하여 맑은 상태의 전천 일사량을 계산하였으며, 전운량에 따라 관측 및 모델의 일사량 값을 비교 분석하였다. 연구 자료는 2012년 강릉원주대학교 복사 관측소의 전천 일사량, 기온, 기압, 습도, 에어로졸 등의 관측 자료와 OMI 센서의 오존전량 자료 그리고 구름의 유무 및 전운량을 판단하기 위하여 자동 전운량 장비인 Skyview 자료를 이용하였다. 전운량이 0 할인 맑은 날의 경우 관측 값과 모델 값이 0.98로 높은 상관계수를 나타내었으나 RMSE가 $36.62Wm^{-2}$로 비교적 높게 나타났다. 이는 Skyview 장비가 얇은 구름이나 박무 및 연무 등의 기상상태를 판단하지 못하였기 때문이다. 흐린 날의 경우 구름의 영향을 보정하기 위해 전운량과 두 값의 차에 대한 비율을 이용한 회귀식을 복사 모델에 적용하였으며, 장비의 오탐지를 제외한 경우 상관계수가 0.92로 높은 상관성을 보였으나 RMSE가 $99.50Wm^{-2}$으로 높은 값을 보였다. 더 정확한 분석을 위해서는 직달 성분의 차폐 유무 및 구름 광학 두께를 포함한 다양한 구름 요소의 추가적인 분석이 요구된다. 이 연구결과는 분 또는 시간에 따른 일사량을 산출하여 일사량이 관측되지 않는 지역에서 유용하게 사용될 수 있다.