Browse > Article

A Study on Radiation Exposure Dose of Operator During Interventional Radiology Procedure  

Jeon, Mi-Eun (Dept. of Radiological Science, Hanseo University)
Lim, Cheong-Hwan (Dept. of Radiological Science, Hanseo University)
Jung, Hong-Ryang (Dept. of Radiological Science, Hanseo University)
You, In-Gyu (Dept. of Radiological Science, Hanseo University)
Hong, Dong-Hee (Dept. of Radiological Science, Seonam University)
Kang, Byung-Sam (Dept. of Radiotechnology, Shingu College)
Publication Information
Journal of radiological science and technology / v.35, no.3, 2012 , pp. 219-226 More about this Journal
Abstract
Interventional radiologists are not aware of the potential injury from procedures. The purpose of this study are to evaluate radiation exposure of interventional radiologist from intervention procedures and to develop guideline of the simple methods for decreasing their radiation exposure from intervention procedure. In this study, Dosimeters were used to monitor operator doses of radiation exposure in a broad range of procedures from 20 interventional radiologist during the periods of 3 months. And, we searched protection methods of each interventional radiologist. During TACE procedure, there was using 0.5 mmPb radiation protector decreased average 89.5 % of radiation exposure. Thicker radiation protector provide decreasing radiation exposure. And radiation exposure dose decreased average 47.7 % by using pulse fluoroscopic mode. Therefore, interventional radiologist should wear protective aprons, use active shielding, monitor their doses, and know how to poisoning themselves during the procedure and operate correct of the machines for minimum dose.
Keywords
Interventional Radiology; Radiation Exposure Dose; Radiation Protection;
Citations & Related Records
연도 인용수 순위
  • Reference
1 D BOR etc: Comparison of effective doses obtainedfrom dose-area product and air kerma measurements in interventional radiology, The British Journal of Radiology, 77, 315-322, 2004   DOI   ScienceOn
2 윤철호, 윤석환, 최준구: 방사선 종사자 근무 분야별 피폭에 관한 검토, 방사선기술과학, 31(3), 217-222, 2008
3 정홍량, 임청환, 이만구, 전국 종합병원 방사선사의 개인피폭선량에 대한 고찰, 방사선기술과학, 28(2), 137-144, 2005
4 Pantos I, Patatoukas G, Katritis DG, Efstathopoulos E: Patient and doses from X-ray angiography during interventional procedures, 5, 1-11, 2009   DOI   ScienceOn
5 Vano E, Goicolea J, Galvan C, et al: Skin radiation injuries in patients following repeated coronary angioplasyt procedures, Br J Radiol, 74, 1023-31, 2001   DOI
6 유인규, 정진욱, 한준구, 박재형, 강위생: 각종 중재적 시술 시술자의 피폭선량, 대한방사선의학회지, 30(2), 265-270, 1994
7 김태일, 윤진호, 백금문, 김정이, 오제선, 이형진: 디지털 디텍터 방식(Flat pannel detector) 혈관조영장비의 선량비교, 대한심맥관중재기술학회지, 10, 84-91, 2007
8 정진욱: 중재적방사선 분야에서의 환자피폭선량 평가, COVP1200815974. 1-93, 2007
9 이은하: 관상동맥조영술 시 환자피폭 감소에 대한 연구, 고려대학교의용과학대학원 석사학위논문, 2010
10 오현진, 오현주, 차승환 등: 진단용방사선관계종사자의 피폭선량 분석에 관한 연구, 식품의약품안전청연구보고서,7, 206-210, 2003
11 ICRP Publication 85: Interventional Procedures Avoiding Radiation Injuries, Publication 85, 2001
12 중재적방사선분야에서의 환자피폭선량 평가: 식품의약안정청, 2007
13 최수용, 김태환, 정차권, 조철구: 우리나라 방사선 관련 작업종사자에 대한 피폭선량 분석, korean journal of epidermiology, 21(1), 72-80, 1999
14 임청환: 전산화단층촬영의 방사선피폭에 의한 위험도 추정, 경원대학교 대학원 박사학위논문, 2005
15 ICRP 73, Radiological Protection and safety in medicine, 5-53, 1998
16 Jen Persliden etc: Patient and staff doses in interventional X-ray procedures in SWEDEN, Radiation Protection Dosimetry, 114, 1-3, 150- 157, 2005   DOI   ScienceOn
17 조현철: 혈관조영실에서 근무하는 방사선 작업 종사자에 대한 방사선 피폭선량 측정과 방사선 안전 관리에 대한 인식과 행동조사, 고려대학교 보건대학원 석사학위논문, 2004
18 N W MARSHALL etc: Patient and staff dosimetryin neuroradiological procedures, The BritishJournal of Radiology, 68, 495-501, 1995