• Title/Summary/Keyword: Coordinate System

Search Result 2,199, Processing Time 0.047 seconds

GPS Surveying for Application of Geodetic Point (실용측지점의 활용을 위한 GPS측량)

  • 오창수
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.20 no.1
    • /
    • pp.33-38
    • /
    • 2002
  • The object of this study is to verify the feasibility in the application of the GPS system data to the existing geodetic and cadastral survey system. WGS-84 data, which were converted into domestic geometric coordinate system, were compared with those of the existing triangular coordinate system in Gwangju area. The significant results in this study are summarized below ; GPS system is more speedy and accurate than the existing triangular coordinate system in the survey of points in triangular coordinate or on the map. And the error in the GPS system was more uniform than that of the existing triangular coordinate system. GPS system is more effective than the existing triangular coordinate system in the future geodetic and cadastral survey because GPS data can be processed by the computer. It is necessary to calculate the conversion coefficients to apply GPS data practically to the existing geodetic and cadastral survey system. It can be achieved by the individual investigation on how the existing data in the domestic coordinate system were determined.

Accuracy Analysis for Conversion of the Cadastral Coordinate System into the Global Coordinate System in Areas between Cadastral Datum (지적 원점계열 인접 지역에서 지적좌표의 세계좌표 변환 정확도 분석)

  • Hong, Sung-Eon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.11
    • /
    • pp.4228-4233
    • /
    • 2010
  • This study analyzed the positional accuracy of cadastral control points where central datum points and eastern datum points meet in the area of standard datum of geographic coordinate, in order to suggest the possibility of converting cadastral coordinates into global coordinates in the future in areas between cadastral datum. 12 GPS observation data points were extracted from the station of triangulation in the experimental area, and the accuracy of coordinate conversions in the area where central and eastern datum points meet was analyzed. The results show that the x-coordinate RMSE was ${\pm}0.0014m$ and the y-coordinate RMSE was ${\pm}0.0011m$. Such excellent results indicated that it is possible to convert to the global coordinate system. Thus, in converting to the global coordinate system, it appears possible to convert even borderline datum point areas if points with stable outcomes are selected by inspecting various triangulation markers, then used to carry out the conversion.

Diagnostics of Journal Bearing System Using Coordinate Transformed Vibration Signals (진동측정 좌표축 회전을 이용한 저널베어링 상태 진단)

  • Youn, Byeng D.;Jeon, Byungchul;Jung, Joonha;Kim, Donghwan;Sohn, Seok-Man
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.97-98
    • /
    • 2014
  • Vibration signal has been widely utilized in the diagnostics of rotating mechanical system. Diagnostics systems in rotating machinery are depends on the vibration data which are acquired from the system. However, the characteristics of acquired data can be vary according to the position of anomaly installed or the position of data acquired. In this research, the coordinate transform of journal bearing vibration signal was proposed to overcome the limitation mentioned above. Journal bearing systems are equipped two gap sensors with ninety degree angles, and it can enable to generate coordinate transformed signals in arbitrary angle domain. More abundant information for each normal or anomaly conditions are obtained from coordinate transformation than only the data of the existing measuring position, then we have developed a reliable and robust diagnosis algorithm for journal bearing system.

  • PDF

Motion Tracking Algorithm for A CCTV System (CCTV 시스템을 위한 움직임 추적 기법)

  • Kang, Seoung-Il;Hong, Sung-Hoon
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.295-296
    • /
    • 2006
  • This paper implements a method that tracking the moving objects that detected by the motion detection function of the digital CCTV system. We simply implement the motion detection function of the digital CCTV system that use frame difference and thresholding. When motion is detected, the motion detection function generates two outputs. One output is the event that the motion is arised in input image frame. The other output is coordinate that motion is exists. Then, do the block matching algorithm[2] using coordinate, that motion is exists, as initial coordinate of the block matching algorithm. The best matched coordinate is new initial coordinate of the block matching algorithm for the next image frame. We simply use the block matching algorithm that implements tracking the moving objects. It is simple, but useful the actual digital CCTV system.

  • PDF

Investigation on the Generalized Hydrodynamic Force and Response of a Flexible Body at Different Reference Coordinate System (기준 좌표계에 따른 탄성체의 일반화 파랑 하중 및 응답에 대한 연구)

  • Heo, Kyeonguk;Choi, Yoon-Rak
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.58 no.6
    • /
    • pp.348-357
    • /
    • 2021
  • In this paper, the generalized hydrodynamic force and response of a flexible body are calculated at different reference coordinate systems. We generalize the equation of motion for a flexible body by using the conservation of momentum (Mei et al., 2005). To obtain the equations in the generalized mode, two different reference coordinates are adopted. The first is the body-fixed coordinate system by a rigid body motion. The other is the inertial coordinate system which has been adopted for the analysis. Using the perturbation scheme in the weakly-nonlinear assumption, the equations of motion are expanded up to second-order quantities and several second-order forces are obtained. Numerical tests are conducted for the flexible barge model in head waves and the vertical bending is only considered in the hydroelastic responses. The results show that the linear response does not have the difference between the two formulations. On the other hand, second-order quantities have different values for which the rigid body motion is relatively large. However, the total summation of second-order quantities has not shown a large difference at each reference coordinate system.

Design of Linear Recursive Target State Estimator for Collision Avoidance System (차량 충돌 방지 시스템을 위한 선형 순환 표적 추정기 설계)

  • Han, Seul-Ki;Ra, Won-Sang;Whang, Ick-Ho;Park, Jin-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1740-1741
    • /
    • 2011
  • This paper proposes a new linear recursive target state estimator for automotive collision warning system. The target motion is modeled in Cartesian coordinate system while the radar measurements such as range, line-of-sight angle and range rate are obtained in polar coordinate system. To solve the problem by nonlinear relation between these two coordinate system, a practical linear filter design scheme employing the predicted line-of-sight Cartesian coordinate system (PLCCS) is proposed. Especially, PLCCS can effectively incorporate range rate measurements into target tracking system. It is known that the utilization of range rate measurements enables the improvement of target tracking performance. Moreover, PLCCS based target tracking system is implemented by linear recursive filter structure and hence is more suitable scheme for the development of reliable collision warning system. The performance of the proposed method is demonstrated by computer simulations.

  • PDF

Regular Polyprism Parallel Coordinate Plot as a Statistical Graphics Tool (통계적 그래픽스 도구로서의 정다각기둥평행좌표그림)

  • Jang, Dae-Heung
    • The Korean Journal of Applied Statistics
    • /
    • v.21 no.4
    • /
    • pp.695-704
    • /
    • 2008
  • The parallel coordinate plot is a graphical data analysis technique for plotting multivariate data. The parallel coordinate plot overcomes the visualization problem of the Cartesian coordinate system for dimensions greater than 4. But, using different ordering of coordinate axes in the parallel coordinate plot of the same data may make different interpretations. Hence, we can use the regular polyprism parallel coordinate plot as an alternative for overcoming the variable arrangement problem of the parallel coordinate plot.

Review and Evaluation of Hand-Arm Coordinate Systems for Measuring Vibration Exposure, Biodynamic Responses, and Hand Forces

  • Dong, Ren G.;Sinsel, Erik W.;Welcome, Daniel E.;Warren, Christopher;Xu, Xueyan S.;McDowell, Thomas W.;Wu, John Z.
    • Safety and Health at Work
    • /
    • v.6 no.3
    • /
    • pp.159-173
    • /
    • 2015
  • The hand coordinate systems for measuring vibration exposures and biodynamic responses have been standardized, but they are not actually used in many studies. This contradicts the purpose of the standardization. The objectives of this study were to identify the major sources of this problem, and to help define or identify better coordinate systems for the standardization. This study systematically reviewed the principles and definition methods, and evaluated typical hand coordinate systems. This study confirms that, as accelerometers remain the major technology for vibration measurement, it is reasonable to standardize two types of coordinate systems: a tool-based basicentric (BC) system and an anatomically based biodynamic (BD) system. However, these coordinate systems are not well defined in the current standard. Definition of the standard BC system is confusing, and it can be interpreted differently; as a result, it has been inconsistently applied in various standards and studies. The standard hand BD system is defined using the orientation of the third metacarpal bone. It is neither convenient nor defined based on important biological or biodynamic features. This explains why it is rarely used in practice. To resolve these inconsistencies and deficiencies, we proposed a revised method for defining the realistic handle BC system and an alternative method for defining the hand BD system. A fingertip-based BD system for measuring the principal grip force is also proposed based on an important feature of the grip force confirmed in this study.

Robust Pelvic Coordinate System Determination for Pose Changes in Multidetector-row Computed Tomography Images

  • Kobashi, Syoji;Fujimoto, Satoshi;Nishiyama, Takayuki;Kanzaki, Noriyuki;Fujishiro, Takaaki;Shibanuma, Nao;Kuramoto, Kei;Kurosaka, Masahiro;Hata, Yutaka
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.10 no.1
    • /
    • pp.65-72
    • /
    • 2010
  • For developing navigation system of total hip arthroplasty (THA) and evaluating hip joint kinematics, 3-D pose position of the femur and acetabulum in the pelvic coordinate system has been quantified. The pelvic coordinate system is determined by manually indicating pelvic landmarks in multidetector-row computed tomography (MDCT) images. It includes intra- and inter-observer variability, and may result in a variability of THA operation or diagnosis. To reduce the variability of pelvic coordinate system determination, this paper proposes an automated method in MDCT images. The proposed method determines pelvic coordinate system automatically by detecting pelvic landmarks on anterior pelvic plane (APP) from MDCT images. The method calibrates pelvic pose by using silhouette images to suppress the affect of pelvic pose change. As a result of comparing with manual determination, the proposed method determined the coordinate system with a mean displacement of $2.6\;{\pm}\;1.6$ mm and a mean angle error of $0.78\;{\pm}\;0.34$ deg on 5 THA subjects. For changes of pelvic pose position within 10 deg, standard deviation of displacement was 3.7 mm, and of pose was 1.28 deg. We confirmed the proposed method was robust for pelvic pose changes.

Redefinition Procedures of the Korean Geodetic System (한국측지좌표계의 재정립에 대한 연구)

  • 이영진;조규전;김원익
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.14 no.2
    • /
    • pp.141-150
    • /
    • 1996
  • A satellite positioning system has been recently introduced in Korea and the applications of the system are in-creasing gradually, and it is, therefore, interested in the geocentric coordinate system. In this paper, the requirements of the redefinition of the Korean geodetic system which is suited to the geocentric datum and the strategies for the establishment of new geodetic networks are considered. It is also taken into account to maintain the control points, in the transition from the old coordinate systems to a new coordinate system.

  • PDF