• Title/Summary/Keyword: Conversion Factor

Search Result 979, Processing Time 0.028 seconds

Size-Specific Dose Estimation In the Korean Lung Cancer Screening Project: Does a 32-cm Diameter Phantom Represent a Standard-Sized Patient in Korean Population?

  • Kim, Eun Young;Kim, Tae Jung;Goo, Jin Mo;Kim, Hyae Young;Lee, Ji Won;Lee, Soojung;Lim, Jun-tae;Kim, Yeol
    • Korean Journal of Radiology
    • /
    • v.19 no.6
    • /
    • pp.1179-1186
    • /
    • 2018
  • Objective: The purposes of this study were to evaluate size-specific dose estimate (SSDE) of low-dose CT (LDCT) in the Korean Lung Cancer Screening (K-LUCAS) project and to determine whether CT protocols from Western countries are appropriate for lung cancer screening in Korea. Materials and Methods: For participants (n = 256, four institutions) of K-LUCAS pilot study, volume CT dose index ($CTDI_{vol}$) using a 32-cm diameter reference phantom was compared with SSDE, which was recalculated from $CTDI_{vol}$ using size-dependent conversion factor (f-size) based on the body size, as described in the American Association of Physicists in Medicine Report 204. This comparison was subsequently assessed by body mass index (BMI) levels (underweight/normal vs. overweight/obese), and automatic exposure control (AEC) adaptation (yes/no). Results: Size-specific dose estimate was higher than $CTDI_{vol}$ ($2.22{\pm}0.75mGy$ vs. $1.67{\pm}0.60mGy$, p < 0.001), since the f-size was larger than 1.0 for all participants. The ratio of SSDE to $CTDI_{vol}$ was higher in lower BMI groups; 1.26, 1.37, 1.43, and 1.53 in the obese (n = 103), overweight (n = 70), normal (n = 75), and underweight (n = 4), respectively. The ratio of SSDE to $CTDI_{vol}$ was greater in standard-sized participants than in large-sized participants independent of AEC adaptation; with AEC, SSDE/$CTDI_{vol}$ in large- vs. standard-sized participants: $1.30{\pm}0.08$ vs. $1.44{\pm}0.08$ (p < 0.001) and without AEC, $1.32{\pm}0.08$ vs. $1.42{\pm}0.06$ (p < 0.001). Conclusion: Volume CT dose index based on a reference phantom underestimates radiation exposure of LDCT in standard-sized Korean participants. The optimal radiation dose limit needs to be verified for standard-sized Korean participants.

Mineralized Polysaccharide Transplantation Modules Supporting Human MSC Conversion into Osteogenic Cells and Osteoid Tissue in a Non-Union Defect

  • Ge, Qing;Green, David William;Lee, Dong-Joon;Kim, Hyun-Yi;Piao, Zhengguo;Lee, Jong-Min;Jung, Han-Sung
    • Molecules and Cells
    • /
    • v.41 no.12
    • /
    • pp.1016-1023
    • /
    • 2018
  • Regenerative orthopedics needs significant devices to transplant human stem cells into damaged tissue and encourage automatic growth into replacements suitable for the human skeleton. Soft biomaterials have similarities in mechanical, structural and architectural properties to natural extracellular matrix (ECM), but often lack essential ECM molecules and signals. Here we engineer mineralized polysaccharide beads to transform MSCs into osteogenic cells and osteoid tissue for transplantation. Bone morphogenic proteins (BMP-2) and indispensable ECM proteins both directed differentiation inside alginate beads. Laminin and collagen IV basement membrane matrix proteins fixed and organized MSCs onto the alginate matrix, and BMP-2 drove differentiation, osteoid tissue self-assembly, and small-scale mineralization. Augmentation of alginate is necessary, and we showed that a few rationally selected small proteins from the basement membrane (BM) compartment of the ECM were sufficient to up-regulate cell expression of Runx-2 and osteocalcin for osteoid formation, resulting in Alizarin red-positive mineral nodules. More significantly, nested BMP-2 and BM beads added to a non-union skull defect, self-generated osteoid expressing osteopontin (OPN) and osteocalcin (OCN) in a chain along the defect, at only four weeks, establishing a framework for complete regeneration expected in 6 and 12 weeks. Alginate beads are beneficial surgical devices for transplanting therapeutic cells in programmed (by the ECM components and alginate-chitosan properties) reaction environments ideal for promoting bone tissue.

Optimization of Preparation Conditions of Vanadium-Based Catalyst for Room Temperature Oxidation of Hydrogen Sulfide (황화수소 상온 산화를 위한 바나듐계 촉매의 제조 조건 최적화 연구)

  • Kang, Hyerin;Lee, Ye Hwan;Kim, Sung Chul;Chang, Soon Woong;Kim, Sung Su
    • Applied Chemistry for Engineering
    • /
    • v.32 no.3
    • /
    • pp.326-331
    • /
    • 2021
  • In this study, the preparation conditions for a TiO2-based vanadium-based catalyst for oxidizing hydrogen sulfide at room temperature were optimized. Four types of commercial TiO2 were used as a catalyst support and the performance evaluation of hydrogen sulfide oxidation at room temperature of V/TiO2 by varying vanadium contents prepared using the impregnation method was performed. Among the types of TiO2 tested, it was confirmed that the catalyst with the vanadium content of 5% and based on TiO2(A) has the best hydrogen sulfide conversion rate of 58%. By comparing the physical and chemical properties of the catalyst, the specific surface area of the support and the species of dominant vanadium are the major factor in catalyst performance. In order to confirm the regeneration characteristics of the catalyst with reduced activity, heat treatment was performed at 400 ℃ for 2 h, and the amount of hydrogen sulfide oxidation decreased by 10% due to the partial deposition of sulfur in the regenerated catalyst, but it was confirmed that the initial performance was similar.

Active Front End Rectifier Control of DC Distribution System Using Neural Network (신경회로망을 적용한 직류배전시스템의 AFE 정류기 제어에 관한 연구)

  • Kim, Seongwan;Jeon, Hyeonmin;Kim, Jongsu
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.7
    • /
    • pp.1124-1128
    • /
    • 2021
  • As regulations of emissions from ships become more stringent, electric propulsion systems have been increasingly used to solve this problem in vessels ranging from large merchant ships to small and medium-sized ships. Methods for improving the efficiency of the electric propulsion system include the improvement of power sources; the use of a system linked to environmentally friendly power sources, such as batteries, fuel cells, and solar power; and the development of hardware and control methodology for rectifiers, power conversion devices, and propulsion motors. The method using a phase-shifting transformer with diodes has been widely used for rectification. Power semiconductor devices with grid connection to an environmentally friendly power source using DC distribution, a variable speed power source, and the application of small and medium-sized electric propulsion systems have been developed. Accordingly, the demand for active front-end (AFE) rectifiers is increasing. In this study, a method using a neural network rather than a conventional proportional-integral controller was proposed to control the AFE rectifier. Tested controller data were used to design a neural network controller trained through MATLAB/Simulink. The neural network controller was applied to a rectification system designed using PSIM software. The results indicated the effectiveness of improving the waveform and power factor DC output stage according to the load variation. The proposed system can be applied as a rectification system for small and medium-sized environmentally friendly ships.

Effects of light intensity on growth performance, blood components, carcass characteristics, and welfare of broilers

  • Hee-Jin, Kim;Jiseon, Son;Hyun-Soo, Kim;Eui-Chul, Hong;Ji-Hyuk, Kim
    • Journal of Animal Science and Technology
    • /
    • v.64 no.5
    • /
    • pp.985-996
    • /
    • 2022
  • This study investigated the effects of light intensity on growth performance, blood components, eye condition, and carcass characteristics of broiler chickens. Three hundred and fifty-two 1-day-old male chicks were assigned to one of four treatments (four repetitions per treatment, 22 birds per repetition) and reared in a floor pen for 5 weeks. From the second week, chicks were reared under four different levels of light intensity (5, 20, 35, and 50 lx) and the lighting duration was maintained at 18-hours light : 6-hours dark (18L : 6D). The feed intake and body weight were measured weekly. At 35 days of age, 12 birds per treatment were randomly selected for blood sampling, eye measurement, and carcass analysis. There were no significant differences in body weight gain, feed intake, and feed conversion ratio among treatments. Triglyceride levels in the serum were significantly higher in the 5 lx treatment, and creatinine was significantly lower in the 5 lx treatment (p < 0.05). The heterophil : lymphocyte ratios decreased significantly as light intensity increased (p < 0.05); however, other blood cell compositions were not affected by light intensity. Interleukin-6 content was significantly higher in the 5 lx treatment than in other treatments (p < 0.05), but the content of tumor necrosis factor-α was not significantly different among treatments. Serum corticosterone concentration was significantly higher at 5 lx than at 20, 35, and 50 lx (p < 0.05). The corneal diameter was the highest in 5 lx treatment (p < 0.05), and tended to increase as the light intensity decreased. Other eye parameters were not significantly different among treatments, but displayed a tendency to increase as the light intensity decreased. Carcass yield and part yields were not affected by light intensity. Meat quality parameters (pH, color, cooking loss, and water-holding capacity) did not show significant difference among the treatments. The results indicate that a light intensity of 5 lx may increase physiological stress or have a negative effect on broiler welfare, even if the performance and carcass characteristics are not affected. Therefore, a light intensity of 20 lx or above is recommended considering both the growth performance and welfare of broilers.

Analysis of Photovoltaic Performance Improvement of Cu2Zn1-xCdxSn(SxSe1-x)4 Thin Film Solar Cells by Controlling Cd2+ Element Alloying Time Using CBD Method (CBD 공법을 이용하여 Cd2+ 원소 Alloying 시간을 조절한 Cu2Zn1-xCdxSn(SxSe1-x)4 박막 태양전지의 광전지 성능 향상 분석)

  • Sang Woo, Park;Suyoung, Jang;Jun Sung, Jang;Jin Hyeok, Kim
    • Korean Journal of Materials Research
    • /
    • v.32 no.11
    • /
    • pp.481-488
    • /
    • 2022
  • The Cu2ZnSn(SxSe1-x)4 (CZTSSe) absorbers are promising thin film solar cells (TFSCs) materials, to replace existing Cu(In,Ga)Se2 (CIGS) and CdTe photovoltaic technology. However, the best reported efficiency for a CZTSSe device, of 13.6 %, is still too low for commercial use. Recently, partially replacing the Zn2+ element with a Cd2+element has attracting attention as one of the promising strategies for improving the photovoltaic characteristics of the CZTSSe TFSCs. Cd2+ elements are known to improve the grain size of the CZTSSe absorber thin films and improve optoelectronic properties by suppressing potential defects, causing short-circuit current (Jsc) loss. In this study, the structural, compositional, and morphological characteristics of CZTSSe and CZCTSSe thin films were investigated using X-ray diffraction (XRD), X-ray fluorescence spectrometer (XRF), and Field-emission scanning electron microscopy (FE-SEM), respectively. The FE-SEM images revealed that the grain size improved with increasing Cd2+ alloying in the CZTSSe thin films. Moreover, there was a slight decrease in small grain distribution as well as voids near the CZTSSe/Mo interface after Cd2+ alloying. The solar cells prepared using the most promising CZTSSe absorber thin films with Cd2+ alloying (8 min. 30 sec.) exhibited a power conversion efficiency (PCE) of 9.33 %, Jsc of 34.0 mA/cm2, and fill factor (FF) of 62.7 %, respectively.

Analysis of Operation System Establishment Cases for Efficient use of Risk Assessment at Construction Sites - H Focusing on Construction Company Cases (건설현장의 위험성평가 효율적 활용을 위한 운영 시스템 구축사례 분석 - H 건설사 사례중심으로)

  • Jae-Bung Lee
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.4
    • /
    • pp.828-838
    • /
    • 2022
  • Purpose: Through the establishment of a computerized system of risk assessment, the purpose is to analyze the case of whether the co-workers who are subject to the risk assessment at the construction site can easily fill it out and expect disaster reduction through efficient risk assessment activities. Method: By providing the risk factors and safety measures for the work by selecting the type of work, the risk estimation and the establishment of countermeasures can be made, and a system has been established to enable practical disaster prevention activities by presenting disaster cases for the work. Result: Through the analysis of the change in the scaled disaster rate for the years following the on-site application after the establishment of the risk assessment computer system of H Construction Company, it was confirmed that the scaled disaster rate of the domestic construction industry increased, while the conversion disaster rate of H Construction Company decreased. Conclusion: Through the computational systemization of risk assessments, workers in the field can easily access the risk assessment, evaluate the risk factors of the process and establish risk prevention measures, and it has been analyzed that there is an impact on the reduction of the disaster rate during the operational analysis period.

Life Cycle Greenhouse Gas Emission Assessment on Locally Generated Kenaf Residue Biomass Fuel in South Korea (EU RED-II 방법론을 적용한 국내 미이용 바이오매스 케나프 펠릿의 전과정 온실가스 배출량 산정)

  • Youn Il Kim;Sun Young Jung;Youngjae Jo;Sung Yoon;Byung Hwan Um
    • Korean Chemical Engineering Research
    • /
    • v.61 no.2
    • /
    • pp.258-264
    • /
    • 2023
  • The greenhouse gas (GHG) emission assessment of kenaf pellet, produced from locally generated kenaf residues in South Korea, has been studied based on the EU RED-II methodology for calculating GHG impact of biomass fuels. Based on the production pathway of kenaf residue pellet and emission coefficients from EU JRC report, the life cycle GHG emission of kenaf residue pellet is assessed as 3.0 gCO2eq/MJpellet and the life cycle GHG emission of electricity generated from kenaf residue pellet is assessed as 11.9 gCO2eq/MJ when electrical efficiency of final conversion is 25%. The potential GHG emission reduction of electricity produced from kenaf pellet is 90.3% compared to the domestic electricity emission factor 42.8 kgCO2eq/MWh. Also, the electricity produced from kenaf pellet can reduce at least 59.6% of GHG emission compared to the electricity produced from imported wood pellets.

Food Habits and Nutrient Intakes by Self-reported Food Consumption of Middle and High School Students In Seoul, Gyeonggi, and Gyeongnam Area (서울, 경기, 경남 일부 지역의 중${\cdot}$고등학생의 식습관과 자가 섭취 상태 조사법을 통한 영양 섭취 평가)

  • Yi, Na-Young;Lee, Kyung-Eun;Kwak, Tong-Kyung
    • Journal of the Korean Society of Food Culture
    • /
    • v.21 no.5
    • /
    • pp.473-480
    • /
    • 2006
  • The purpose of this study were to investigate middle and high school students' food habits and food attitudes, and to assess student's nutrient consumption. A self-administered questionnaire was developed based on review of literature. The questionnaire consisted of three sections (food habits, food attitudes, and food consumption). The questionnaires were distributed to 4,050 students enrolled in 34 middle and high schools located in Seoul, Gyeonggi, and Gyeongnam provinces. A final response rate was 88.2% (3,570) excluding responses that had significant missing data. Data of the food habits and food attitudes were analyzed with descriptive analysis, $x^2$-test, and t-test using SPSS WIN(ver.11.0). The student's self-reported food consumption data was converted into nutrient consumption using conversion factor. Many middle and high school students skipped breakfast and/or dinner. Approximately 29% of the students did not eat vegetables and fruits. Scores of the middle school student's attitudes(19.1) towards foods were significantly higher than those of the high school student's attitudes(18.7)(p<.001). Student's nutrient intakes were estimated according to the student's self-reported food consumption data. The nutrient intakes were compared with DRIs(Dietary Reference Intakes: DRIs) for their age groups. The result of EAR(Estimated Average Requirement: EAR) cut-point method demonstrated 57.7% of middle school boys, 64.4% of middle school girls, 70.2% of high school boys, and 71.0% of high school girls did not meet EAR for Calcium. Additionally, it showed that 39.0% of middle school boys, 23.7% of middle school girls, 58.4% of high school boys, and 24.4% of high school girls did not consume EAR for Vitamin $B_1$. 25.7% of middle school boys did not meet EAR for Vitamin $B_2$, while 44.4% high school boys did not satisfy EAR for Vitamin $B_2$.

Myocardial Coverage and Radiation Dose in Dynamic Myocardial Perfusion Imaging Using Third-Generation Dual-Source CT

  • Masafumi Takafuji;Kakuya Kitagawa;Masaki Ishida;Yoshitaka Goto;Satoshi Nakamura;Naoki Nagasawa;Hajime Sakuma
    • Korean Journal of Radiology
    • /
    • v.21 no.1
    • /
    • pp.58-67
    • /
    • 2020
  • Objective: Third-generation dual-source computed tomography (3rd-DSCT) allows dynamic myocardial CT perfusion imaging (dynamic CTP) with a 10.5-cm z-axis coverage. Although the increased radiation exposure associated with the 50% wider scan range compared to second-generation DSCT (2nd-DSCT) may be suppressed by using a tube voltage of 70 kV, it remains unclear whether image quality and the ability to quantify myocardial blood flow (MBF) can be maintained under these conditions. This study aimed to compare the image quality, estimated MBF, and radiation dose of dynamic CTP between 2ndDSCT and 3rd-DSCT and to evaluate whether a 10.5-cm coverage is suitable for dynamic CTP. Materials and Methods: We retrospectively analyzed 107 patients who underwent dynamic CTP using 2nd-DSCT at 80 kV (n = 54) or 3rd-DSCT at 70 kV (n = 53). Image quality, estimated MBF, radiation dose, and coverage of left ventricular (LV) myocardium were compared. Results: No significant differences were observed between 3rd-DSCT and 2nd-DSCT in contrast-to-noise ratio (37.4 ± 11.4 vs. 35.5 ± 11.2, p = 0.396). Effective radiation dose was lower with 3rd-DSCT (3.97 ± 0.92 mSv with a conversion factor of 0.017 mSv/mGy∙cm) compared to 2nd-DSCT (5.49 ± 1.36 mSv, p < 0.001). Incomplete coverage was more frequent with 2nd-DSCT than with 3rd-DSCT (1.9% [1/53] vs. 56% [30/54], p < 0.001). In propensity score-matched cohorts, MBF was comparable between 3rd-DSCT and 2nd-DSCT in non-ischemic (146.2 ± 26.5 vs. 157.5 ± 34.9 mL/min/100 g, p = 0.137) as well as ischemic myocardium (92.7 ± 21.1 vs. 90.9 ± 29.7 mL/min/100 g, p = 0.876). Conclusion: The radiation increase inherent to the widened z-axis coverage in 3rd-DSCT can be balanced by using a tube voltage of 70 kV without compromising image quality or MBF quantification. In dynamic CTP, a z-axis coverage of 10.5 cm is sufficient to achieve complete coverage of the LV myocardium in most patients.