• 제목/요약/키워드: Convective

검색결과 1,279건 처리시간 0.038초

Global Coupled 모델 2와 3.1의 MJO 모의성능 평가 (Assessment of MJO Simulation with Global Coupled Model 2 and 3.1)

  • 문자연;김기영;조정아;양영민;현유경;김백조
    • 대기
    • /
    • 제32권3호
    • /
    • pp.235-246
    • /
    • 2022
  • A large number of MJO skill metrics and process-oriented MJO simulation metrics have been developed by previous studies including the MJO Working Group and Task Force. To assess models' successes and shortcomings in the MJO simulation, a standardized set of diagnostics with the additional set of dynamics-oriented diagnostics are applied. The Global Coupled (GC) model developed for the operation of the climate prediction system is used with the comparison between the GC2 and GC3.1. Two GC models successfully capture three-dimensional dynamic and thermodynamic structure as well as coherent eastward propagation from the reference regions of the Indian Ocean and the western Pacific. The low-level moisture convergence (LLMC) ahead of the MJO deep convection, the low-level westerly and easterly associated with the coupled Rossby-Kelvin wave and the upper-level divergence are simulated successfully. The GC3.1 model simulates a better three-dimensional structure of MJO and thus reproduces more realistic eastward propagation. In GC2, the MJO convection following the LLMC near and east of the Maritime Continent is much weaker than observation and has an asymmetric distribution of both low and upper-level circulation anomalies. The common shortcomings of GC2 and GC3.1 are revealed in the shorter MJO periods and relatively weak LLMC as well as convective activity over the western Indian Ocean.

Theoretical fabrication of Williamson nanoliquid over a stretchable surface

  • Sharif, Humaira;Hussain, Muzamal;Khadimallah, Mohamed Amine;Ayed, Hamdi;Taj, Muhammad;Bhutto, Javed Khan;Mahmoud, S.R.;Iqbal, Zafer;Ahmad, Shabbir;Tounsi, Abdelouahed
    • Advances in concrete construction
    • /
    • 제14권2호
    • /
    • pp.103-113
    • /
    • 2022
  • On the basis of fabrication, the utilization of nano material in numerous industrial and technological system, obtained the utmost significance in current decade. Therefore, the current investigation presents a theoretical disposition regarding the flow of electric conducting Williamson nanoliquid over a stretchable surface in the presence of the motile microorganism. The impact of thermal radiation and magnetic parameter are incorporated in the energy equation. The concentration field is modified by adding the influence of chemical reaction. Moreover, the splendid features of nanofluid are displayed by utilizing the thermophoresis and Brownian motion aspects. Compatible similarity transformation is imposed on the equations governing the problem to derive the dimensionless ordinary differential equations. The Homotopy analysis method has been implemented to find the analytic solution of the obtained differential equations. The implications of specific parameters on profiles of velocity, temperature, concentration and motile microorganism density are investigated graphically. Moreover, coefficient of skin friction, Nusselt number, Sherwood number and density of motile number are clarified in tabular forms. It is revealed that thermal radiation, thermophoresis and Brownian motion parameters are very effective for improvement of heat transfer. The reported investigation can be used in improving the heat transfer appliances and systems of solar energy.

Seismic behavior of liquid storage tanks with 2D and 3D base isolation systems

  • Kilic, Samet;Akbas, Bulent;Shen, Jay;Paolacci, Fabrizio
    • Structural Engineering and Mechanics
    • /
    • 제83권5호
    • /
    • pp.627-644
    • /
    • 2022
  • In past major earthquakes (1994 Northridge, 1995 Kobe, Chi-Chi 1999, Kocaeli 1999), significant damages occurred in the liquid storage tanks. The basic failure patterns were observed to be the buckling of the tank wall and uplift of the anchorage system. The damages in the industrial facilities and nuclear power plants have caused the spread of toxic substances to the environment and significant fires. Seismic isolation can be used in liquid storage tanks to decouple the structure and decrease the structural demand in the superstructure in case of ground shaking. Previous studies on the use of seismic isolation systems on liquid storage tanks show that an isolation system reduces the impulsive response but might slightly increase the convective one. There is still a lack of understanding of the seismic response of seismically isolated liquid storage tanks considering the fluid-structure interaction. In this study, one broad tank, one medium tank, and one slender tank are selected and designed. Two- and three-dimensional elastomeric bearings are used as seismic isolation systems. The seismic performance of the tanks is then investigated through nonlinear dynamic time-history analyses. The effectiveness of each seismic isolation system on tanks' performance was investigated. Isolator tension forces, modal analysis results, hydrodynamic stresses, strains, sloshing heights and base shear forces of the tanks are compared. The results show that the total base shear is lower in 3D-isolators compared to 2D-isolators. Even though the tank wall stresses, and strains are slightly higher in 3D-isolators, they are more efficient to prevent the tension problem.

Micro-Channel형 열교환기에 부착된 핀의 열접촉저항이 열전달 특성에 미치는 영향 (Effect of Thermal Contact Resistence on the Heat Transfer Characteristics of Air Flow around the Finned Micro-Channel Tube for MF Evaporator)

  • 박용석;성홍석;성동민;서정세
    • 한국기계가공학회지
    • /
    • 제20권11호
    • /
    • pp.121-126
    • /
    • 2021
  • In this study, the effect of thermal contact resistance between pin-channel tubes on the heat transfer characteristics was analytically examined around the channel tubes with the pins attached to two consecutive arranged channel pipes. The numerical results showed that the heat transfer coefficient decreased geometrically as the thermal contact resistance increased, and the corresponding temperature change on the contact surface increased as the thermal contact resistance increased. The thinner the pin, the more pronounced the geometric drop in the heat transfer coefficient. It was confirmed that the higher the height of the pin, the higher was the heat transfer coefficient, however, the greater the size of the thermal contact resistance, the smaller was the heat transfer coefficient. It was found that the temperature change in the inner wall of the channel tube did not significantly affect the heat transfer characteristics owing to the thermal contact resistance. Furthermore, the velocity of air at the entrance of the channel tube was proportional to the heat transfer coefficient due to a decrease in the convective heat resistance corresponding to an increase in the flow rate.

Relationship between Low-level Clouds and Large-scale Environmental Conditions around the Globe

  • Sungsu Park;Chanwoo Song;Daeok Youn
    • 한국지구과학회지
    • /
    • 제43권6호
    • /
    • pp.712-736
    • /
    • 2022
  • To understand the characteristics of low-level clouds (CLs), environmental variables are composited on each CL using individual surface observations and six-hourly upper-air meteorologies around the globe. Individual CLs has its own distinct environmental conditions. Over the eastern subtropical and western North Pacific Ocean in JJA, stratocumulus (CL5) has a colder sea surface temperature (SST), stronger and lower inversion, and more low-level cloud amount (LCA) than the climatology whereas cumulus (CL12) has the opposite characteristics. Over the eastern subtropical Pacific, CL5 and CL12 are influenced by cold and warm advection within the PBL, respectively but have similar cold advection over the western North Pacific. This indicates that the fundamental physical process distinguishing CL5 and CL12 is not the horizontal temperature advection but the interaction with the underlying sea surface, i.e., the deepening-decoupling of PBL and the positive feedback between shortwave radiation and SST. Over the western North Pacific during JJA, sky-obscuring fog (CL11), no low-level cloud (CL0), and fair weather stratus (CL6) are associated with anomalous warm advection, surface-based inversion, mean upward flow, and moist mid-troposphere with the strongest anomalies for CL11 followed by CL0. Over the western North Pacific during DJF, bad weather stratus (CL7) occurs in the warm front of the extratropical cyclone with anomalous upward flow while cumulonimbus (CL39) occurs on the rear side of the cold front with anomalous downward flow. Over the tropical oceans, CL7 has strong positive (negative) anomalies of temperature in the upper troposphere (PBL), relative humidity, and surface wind speed in association with the mesoscale convective system while CL12 has the opposite anomalies and CL39 is in between.

이온교환막의 균질/비균질 표면 형상에 따른 전기 와류 가시화 및 전기적 특성 분석 (Visualization and Electrical Response of Electroconvective Vortices on the Surface of Homo/Heterogeneous Ion Exchange Membranes)

  • 조명현;최진웅;김범주
    • 한국재료학회지
    • /
    • 제33권1호
    • /
    • pp.21-28
    • /
    • 2023
  • The electromembrane process, which has advantages such as scalability, sustainability, and eco-friendliness, is used in renewable energy fields such as fuel cells and reverse electrodialysis power generation. Most of the research to visualize the internal flow in the electromembrane process has mainly been conducted on heterogeneous ion exchange membranes, because of the non-uniform swelling characteristics of the homogeneous membrane. In this study, we successfully visualize the electro-convective vortices near the Nafion homogeneous membrane in PDMS-based microfluidic devices. To reinforce the mechanical rigidity and minimize the non-uniform swelling characteristics of the homogeneous membrane, a newly developed swelling supporter was additionally adapted to the Nafion membrane. Thus, a clear image of electroconvective vortices near the Nafion membrane could be obtained and visualized. As a result, we observed that the heterogeneous membrane has relatively stronger electroconvective vortices compared to the Nafion homogeneous membranes. Regarding electrical response, the Nafion membrane has a higher limiting current and less overlimiting current compared to the heterogeneous membrane. Based on our visualization, it is assumed that the heterogeneous membrane has more activated electroconvective vortices, which lower electrical resistance in the overlimiting current regime. We anticipate that this work can contribute to the fundamental understanding of the ion transport characteristics depending on the homogeneity of ion exchange membranes.

연속시간 마코프 프로세스를 이용한 지하매질에서의 통계적 핵종이동 모델 (A Stochastic Model for the Nuclide Migration in Geologic Media Using a Continuous Time Markov Process)

  • 이연명;강철형;한필수;박헌휘;이건재
    • Nuclear Engineering and Technology
    • /
    • 제25권1호
    • /
    • pp.154-165
    • /
    • 1993
  • 연속시간 마코프프로세스를 이용한 한 통계적 방법에 의한 일차원 지하 핵종이동 모델이 제시되었다. 지하매질은 보편적으로 지하수속도, 분산계수 또는 지연계수 등 물리화학적 변수 등의 비균질성을 보여 일반적인 결정론적 이류분산모델로는 잘 기술되지 않는다. 통계적 모델에서의 최종결과는 시간에 따른 함수로서의 기대값과 그 기대값의 분산도를 보여주는 분산치다. 매질이 균질하다고 생각될 정도로 나뉘어진 구획에 대한 핵종의 농도 분포를 구하여 결정론적인 해석해에 의한 농도분포와 비교하여 비균질 매질, 또는 현저하게 구분되는 다층매질의 경우에 대해서 유용 할 것이라는 결론을 얻었다. 매질을 나눈 구획수가 수치적 분산에 민감한 것으로 나타났지만 해석적 모델에 의해 분산계수가 보정될 수 있었다.

  • PDF

격납용기 피동냉각계통내 자연순환 공기유량 및 열전달 실험연구 (An Experiment of Natural Circulated Air Flow and Heat Transfer in the Passive Containment Cooling System)

  • 류석희;오승민;박군철
    • Nuclear Engineering and Technology
    • /
    • 제26권4호
    • /
    • pp.516-525
    • /
    • 1994
  • TMI 및 Chernobyl 사고이후 향후 원전에 대한 안전성 향상을 강화하기위해 개량형 원전에 대해 여러가지 피동형 안전설비가 제안되고 있다. 피동냉각계통의 타당성을 검증하고 상세 설계자료를 제공하기 위해, 본 연구는 웨스팅하우스사의 AP-600 피동격납용기와 같은 한쪽 가열면을 갖는 폐쇄유로에 대한 공기 유입구 위치 및 외부영향이 자연순환 공기유량에 미치는 영향과 자연 및 강제대류하에서 대류열전달계수를 조사하였다. 본 실험은 AP-600 격납용기를 1/26로 축소한 segment 유형의 실험장치를 토대로 수행되었다. 자연 및 강제대류 조건하의 공기유로내 특정 위치에서 공기의 속도 및 온도를 측정하였다. 실험결과는 일차원 단순 모델과 비교하였으며, 좋은 일치점을 보였다.

  • PDF

Thermodynamic simulation and structural optimization of the collimator in the drift duct of EAST-NBI

  • Ning Tang;Chun-dong Hu;Yuan-lai Xie;Jiang-long Wei;Zhi-Wei Cui;Jun-Wei Xie;Zhuo Pan;Yao Jiang
    • Nuclear Engineering and Technology
    • /
    • 제54권11호
    • /
    • pp.4134-4145
    • /
    • 2022
  • The collimator is one of the high-heat-flux components used to avoid a series of vacuum and thermal problems. In this paper, the heat load distribution throughout the collimator is first calculated through experimental data, and a transient thermodynamic simulation analysis of the original model is carried out. The error of the pipe outlet temperature between the simulated and experimental values is 1.632%, indicating that the simulation result is reliable. Second, the model is optimized to improve the heat transfer performance of the collimator, including the contact mode between the pipe and the flange, the pipe material and the addition of a twisted tape in the pipe. It is concluded that the convective heat transfer coefficient of the optimized model is increased by 15.381% and the maximum wall temperature is reduced by 16.415%; thus, the heat transfer capacity of the optimized model is effectively improved. Third, to adapt the long-pulse steady-state operation of the experimental advanced superconducting Tokamak (EAST) in the future, steady-state simulations of the original and optimized collimators are carried out. The results show that the maximum temperature of the optimized model is reduced by 37.864% compared with that of the original model. The optimized model was changed as little as possible to obtain a better heat exchange structure on the premise of ensuring the consumption of the same mass flow rate of water so that the collimator can adapt to operational environments with higher heat fluxes and long pulses in the future. These research methods also provide a reference for the future design of components under high-energy and long-pulse operational conditions.

Revisiting the Z-R Relationship Using Long-term Radar Reflectivity over the Entire South Korea Region in a Bayesian Perspective

  • Kim, Tae-Jeong;Kim, Jin-Guk;Kim, Ho Jun;Kwon, Hyun-Han
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2021년도 학술발표회
    • /
    • pp.275-275
    • /
    • 2021
  • A fixed Z-R relationship approach, such as the Marshall-Palmer relationship, for an entire year and for different seasons can be problematic in cases where the relationship varies spatially and temporally throughout a region. From this perspective, this study explores the use of long-term radar reflectivity for South Korea to obtain a nationwide calibrated Z-R relationship and the associated uncertainties within a Bayesian regression framework. This study also investigates seasonal differences in the Z-R relationship and their roles in reducing systematic error. Distinct differences in the Z-R parameters in space are identified, and more importantly, an inverse relationship between the parameters is clearly identified with distinct regimes based on the seasons. A spatially structured pattern in the parameters exists, particularly parameter α for the wet season and parameter β for the dry season. A pronounced region of high values during the wet and dry seasons may be partially associated with storm movements in that season. Finally, the radar rainfall estimates through the calibrated Z-R relationship are compared with the existing Z-R relationships for estimating stratiform rainfall and convective rainfall. Overall, the radar rainfall fields based on the proposed modeling procedure are similar to the observed rainfall fields, whereas the radar rainfall fields obtained from the existing Marshall-Palmer Z-R relationship show a systematic underestimation. The obtained Z-R relationships are validated by testing the predictions on unseen radar-gauge pairs in the year 2018, in the context of cross-validation. The cross-validation results are largely similar to those in the calibration process, suggesting that the derived Z-R relationships fit the radar-gauge pairs reasonably well.

  • PDF