• Title/Summary/Keyword: Continuous Positive Airway Pressure

Search Result 87, Processing Time 0.024 seconds

A Study on the Changes in Ventilator Care Rate and Outcome of Very Low Birth Weight Infants During Last Four Years (최근 4년간 극소 저출생 체중아의 인공 호흡기 치료율과 경과 변화에 관한 연구)

  • Jung, Byun Kyung;Kim, Yeoung Ju;Lee, Sang Geel
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.11
    • /
    • pp.1073-1079
    • /
    • 2003
  • Purpose : Recently there has been a decrease in ventilator care rate and duration of very low birth weight infants(VLBWI) in Fatima Hospital. The aims of this study were to survey the frequency and duration of ventilation in VLBWI and to develop a non-invasive neonatal intensive care unit (NICU) policy. Methods : We performed a retrospective study of 284 newborn of infants less than 1,500 gm admitted to NICU and discharged from January 1998 to December 2001. Patients were intubated or applied continuous positive airway pressure(CPAP) via nasal prong immediately after presenting signs of respiratory distress. We analyzed epidemiologic data to study the changes in ventilator care rate, duration and outcome of ventilator care groups. Results : Of 284 newborn infants, 146 required invasive management, such as endotracheal intubation and assisted ventilation. The characteristics, the severity of clinical symptoms and laboratory findings in ventilator care groups at birth showed no significant differences. The annual proportion of infants requiring assisted ventilation decreased according to increasing gestational age. The median duration of ventilation decreased markedly from 6.0 days in 1998 to 2.7 days in 2001. Final complications and outcomes in ventilator care groups showed no significant differences. Conclusion : Our study shows a significant reduction in the invasiveness of the treatment of VLBW infants, which was not associated with an increased mortality or morbidity. A non-invasive strategy for the VLBW infant with minimal to moderate respiratory distress after birth in NICU is better than immediate invasive management. Non-invasive nasal CPAP is a simpler and safer method than invasive assisted ventilation.

A Case of Obstructive Sleep Apnea Syndrome Associated with Primary Hypothyroidism and Dilated Cardiomyopathy (원발성 갑상선 기능저하증과 확장형 심근증이 동반된 폐쇄성 수면무호흡증후군 1예)

  • Yu, Sung-Keun;Park, Ji-Young;Pack, Jong-Hae;Park, Hye-Jung;Shin, Kyeong-Cheol;Chung, Jin-Hong;Lee, Kwan-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.51 no.6
    • /
    • pp.590-596
    • /
    • 2001
  • The hallmarks of sleep apnea syndrome include daytime hypersomnolence, snoring, obesity, disturbed nocturnal sleep, and apneic episodes. Thyroid deficiency states are now a well recognized cause of sleep apnea. Central, obstructive, and mixed patterns of sleep apnea may be observed in hypothyroidism. A-33-yr-old man was admitted complaining of daytime hypersomnolence, snoring, sleep apnea and obesity. A polysomnogram showed obstructive pattern of sleep apnea syndrome. Physical examination and hormonal study revealed a narrowing of the upper airway and primary hypothyroidism. Dilated cardiomyopathy was diagnosed by echocardiogram. The poctients was treated for obstructive sleep apnea syndrome with nasal continuous positive airway pressure(CPAP) for 2 months and the underlying hypothyroidism with thyroid hormone therapy. This successfully controlled the snoring, sleep apnea, and other apnea-related symptoms. Here, we describe our experience of nasal CP AP and thyroid hormone therapy in a patient with primary hypothyroidism associated with obstructive sleep apnea syndrome and dilated cardiomyopathy with review of the relevant literature.

  • PDF

Snoring Clinic Visitors' Knowledge of Obstructive Sleep Apnea Syndrome (코골이 클리닉을 방문한 환자들의 폐쇄성 수면무호흡증 인식도)

  • Lee, So-Jin;Lee, Jin-Seong;Shin, Hong-Beum;Cho, Sang-Yong;Rhee, Chae-Seo;Jeong, Do-Un
    • Sleep Medicine and Psychophysiology
    • /
    • v.18 no.2
    • /
    • pp.87-94
    • /
    • 2011
  • Objective: OSAS (obstructive sleep apnea syndrome) is a common disorder and its consequences are often serious. It is important to detect the disorder early in the course for proper treatment. This study is to grasp the snoring clinic visitors' knowledge level of OSAS. Method: One hundred and seventy-nine visitors at the of snoring clinic of Seoul National University Hospital were surveyed by questionnaire about reasons of visit and knowledge of treatment methods of snoring and OSAS, diagnostic method, OSAS-related symptoms, and complications. Results: Most of the respondents (89.4%) "have already heard about OSAS" and the major sources of information was the mass media (58.1%) such as television and radio. More than half (60.3%) were aware that snoring is closely related to OSAS. More than half (59.8%) recognized that a nocturnal polysomnograpy was necessary for proper diagnosis. Two thirds (67%) of the respondents noted surgery as a treatment for snoring. More than half (55.9%) answered that they would follow the doctor's advice on the treatment choice. Only 12.3% of respondents "have heard about nCPAP". No one chose nCPAP (nasal continuous positive airway pressure) as a treatment for either snoring or OSAS. About one third (34.6%) of the respondents were aware that OSAS is related to hypertension. Only 12.8% noted that OSAS is related to diabetes mellitus. Conclusion: Visitors at the snoring clinic were found to have substantially limited knowledge of health risks and proper treatments of OSAS. We suggest that it is crucially important to educate patients and offer easy-to-understand information on snoring and OSAS. We predict that provision of educaiton and information to patients and general public will faciliate the diagnosis and treatment of snoring and OSAS and reduce the related disorders such as hypertension, stroke, and diabetes mellitus.

Preliminary Study of The Periodic Limb Movement Disorder Following Nasal CPAP : Is It Associated With Supine-Sleeping Position? (지속적 양압술과 수면중 주기적 사지운동 장애의 관계에 대한 예비적 연구 : 앙와위가 주기적 사지운동 장애와 관련되는가?)

  • Yang, Chang-Kook;Clerk, Alex A
    • Sleep Medicine and Psychophysiology
    • /
    • v.4 no.2
    • /
    • pp.164-171
    • /
    • 1997
  • Introduction : Periodic limb movement disorder (PLMD) is shown to common in patients with OSA and may become evident or worsened when treated with nasal continuous positive airway pressure (CPAP). Whether this is due to im proved sleep continuity. adverse nocturnal body positioning, uncovered by CPAP, or due to the CPAP stimulus is still debat-ed. We hypothesized that the increase in PLM activity following CPAP is associated with more supine-sleeping tendencies when being treated with CPAP. In the present work, we compared differences in the PLMD index (PLMI) and sleeping position of patients with sleep disordered breathing before and after CPAP treatment. Method : We studied 16 patients (mean age 46 yr, 9M, 7F) with OSA (11 patients) or UARS (5 patients) who either had PLMD on initial polysomnogram (baseline PSG) or on nasal CPAP trial (CPAP PSG). All periodic leg movements were scored on anterior tibialis EMG during sleep according to standard criteria (net duration; 0.5-5.0 seconds, intervals; 4-90 seconds. 4 consecutive movements). Paired t-tests compared PLMD index (PLMI), PLMD-related arousal index (PLMD-ArI), respiratory disturbance index (RDI), and supine sleeping position spent with baseline PSG and CPAP PSG. Results : Ten patients (63%) on baseline PSG and fifteen patients (94%) on CPAP PSG had documented PLMD ($PLMI{\ge}5$) respectively with significant increase on CPAP PSG(p<0.05). Ten patients showed the emergence (6/10 patients) or substantial worsening (4/10 patients) of PLMD during CPAP trial. Mean CPAP pressure was $7.6{\pm}1.8\;cmH_2O$. PLMI tended to increase from baseline PSG to CPAP PSG, and significantly increase when excluding 2 outlier (baseline PSG, $19.0{\pm}25.8/hr$ vs CPAP PSG, $29.9{\pm}12.5/hr$, p<0.1). PLMD-ArI showed no significant change, but a significant decrease was detected when excluding 2 outlier (p<0.1). There was no significant sleeping positional difference (supine vs non-supine) on baseline PSG, but significantly more supine position (supine vs non-supine, p<0.05) on CPAP PSG. There was no significant difference in PLMI during supine-sleeping and nonsupine-sleeping position on both of baseline PSG and CPAP PSG. There was also no significant difference in PLMI during supine-sleeping position between baseline PSG and CPAP PSG. With nasal CPAP, there was a highly significant reduction in the RDI (baseline PSG, $14.1{\pm}21.3/hr$ vs CPAP PSG, $2.7{\pm}3.9/hr$, p<0.05). Conclusion : This preliminary data confirms previous findings that CPAP is a very effective treatment for OSA, and that PLMD is developed or worsened with treatment by CPAP. This data also indicates that supine-sleeping position is more common when being treated with CPAP. However, there was no clear evidence that supine position is the causal factor of increased PLMD with CPAP. It is, however, suggested that the relative movement limitation induced by CPAP treatment could be a contributory factor of PLMD.

  • PDF

Comparison of Two Methods of Recruiting the Acutely Injured Lung (급성 폐손상에서 폐를 Recruit시키는 방법간의 비교 연구)

  • Suh, Gee-Young;Kang, Kyeong-Woo;Park, Sang-Joon;Kim, Ho-Choel;Young, Lim-Si;Chung, Man-Pyo;Han, Jeong-Ho;Kim, Ho-Joong;Kwon, O-Jung;Rhee, Chong-H.
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.4
    • /
    • pp.500-512
    • /
    • 2000
  • Background : To evaluate the efficacy of two methods of obtaining lung recruitment to reduce ventilator-induced lung injury(VILI). Methods : Fifteen New-Zealand white rabbits were ventilated in the pressure-controlled mode while maintaining constant tidal volume(10 ml/kg) and fixed respiration rate. Lung injury was induced by repeated saline lavage (PaO2<100 mmHg), and the pressure-volume curve was drawn to obtain Pflex. The animals were then randomly assigned to three groups and ventilated for 4 hours. In the control group(n=5), positive end-expiratory pressure(PEEP) less than that of Pflex by 3 mmHg was applied throughout the study. In the recruitment maneuver(RM) group(n=5), RM(CPAP of 22.5 mmHg, for 45 seconds) was performed every 15 minutes in addition to PEEP level less than Pflex by 3 mmHg This phrase is unclear. In the Pflex group, PEEP of Pflex was given without RM. Gas exchange, lung mechanics, and hemodynamics parameters as well as pathology were examined. Results : 1) Both the control and RM groups showed decreasing tendency in PaO2 with time. There was significantly decreased PaO2 at 4 hr compared to Ihr(p<0.05). But in the Pflex group, PaO2 did not decrease with time(p<0.05 vs other groups at 3, 4 hr). PaCO2 did not show significant difference among the three groups. 2) There was no significant difference in static compliance and plateau pressure. Mean blood pressure and heart rate also did not show any significant difference among the three groups. 3) The pathologic exam showed significantly less neutrophil infiltration in the Pflex group than in the control group(p<0.05). There was borderline significant difference in hyaline membrane score among the groups (p= 0.0532). Conclusion : Although recruitment maneuver of the injured lung may be important in decreasing VILI, it alone may not be sufficient to minimize VILI.

  • PDF

Sleep Fragementation Decreases during the nCPAP Titration Night in Obstructive Sleep Apnea Syndrome (폐쇄성 수면무호흡증에서 지속적 상기도 양압술 압력 처방 검사 시 나타나는 수면분절의 감소)

  • Lee, Jin-Seong;Jeong, Do-Un
    • Sleep Medicine and Psychophysiology
    • /
    • v.15 no.2
    • /
    • pp.82-86
    • /
    • 2008
  • Objectives: Obstructive sleep apnea syndrome (OSAS) not only causes respiratory disturbances during sleep but also decreases the quality of nocturnal sleep through sleep fragmentation and sleep structure change. We aimed at comparing the changes in sleep fragmentation and structure between baseline (diagnostic) nocturnal polysomnography (NPSG) and nCPAP (nasal continuous positive airway pressure) titration trial. Methods: One hundred and three patients with a baseline night of respiratory disturbance index (RDI) of 5 or greater and reduced RDI score during nCPAP titration night were retrospectively selected for the study. Sleep fragementation and sleep structure between baseline NPSG and the NPSG during nCPAP titration were compared. Sleep fragmentation index (SFI) was defined as the total number of awakenings and shifts to stage 1 sleep divided by the total sleep time in hour. SFI and other polysomnographic parameters were statistically compared between the two nights. Results: SFI during baseline NPSG and nCPAP titration nights were $29.0{\pm}13.8$ and $15.2{\pm}8.8$, respectively, indicating a significant SFI decrease during nCPAP titration (t=9.7, p<0.01). SFI showed significant negative correlations with sleep efficiency (r=-0.60, p<0.01) and total sleep time (r=-0.45, p<0.01) and a positive correlation with RDI (r=0.28, p<0.01). Conclusion: Use of nCPAP, even during the titration, significantly decreases sleep fragmentation and improves sleep structure in OSAS patients. We suggest that SFI may be utilized as a measure of assessing OSAS severity and nCPAP efficacy.

  • PDF

The Effect of Pressure Support on Respiratory Mechanics in CPAP and SIMV (CPAP 및 SIMV Mode하에서 Pressure Support 사용이 호흡역학에 미치는 효과)

  • Lim, Chae-Man;Jang, Jae-Won;Choi, Kang-Hyun;Lee, Sang-Do;Koh, Youn-Suck;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong;Park, Pyung-Whan;Choi, Jong-Moo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.3
    • /
    • pp.351-360
    • /
    • 1995
  • Background: Pressure support(PS) is becomimg a widely accepted method of mechanical ventilation either for total unloading or for partial unloading of respiratory muscle. The aim of the study was to find out if PS exert different effects on respiratory mechanics in synchronized intermittent mandatory ventilation(SIMV) and continuous positive airway pressure (CPAP) modes. Methods: 5, 10 and 15 cm $H_2O$ of PS were sequentially applied in 14 patients($69{\pm}12$ yrs, M:F=9:5) and respiratory rate (RR), tidal volume($V_T$), work of breathing(WOB), pressure time product(PTP), $P_{0.1}$, and $T_1/T_{TOT}$ were measured using the CP-100 pulmonary monitor(Bicore, USA) in SIMV and CPAP modes respectively. Results: 1) Common effects of PS on respiratory mechanics in both CPAP and SIMV modes As the level of PS was increased(0, 5, 10, 15 cm $H_2O$), $V_T$ was increased in CPAP mode($0.28{\pm}0.09$, $0.29{\pm}0.09$, $0.31{\pm}0.11$, $0.34{\pm}0.12\;L$, respectively, p=0.001), and also in SIMV mode($0.31{\pm}0.15$, $0.32{\pm}0.09$, $0.34{\pm}0.16$, $0.36{\pm}0.15\;L$, respectively, p=0.0215). WOB was decreased in CPAP mode($1.40{\pm}1.02$, $1.01{\pm}0.80$, $0.80{\pm}0.85$, $0.68{\pm}0.76$ joule/L, respectively, p=0.0001), and in SIMV mode($0.97{\pm}0.77$, $0.76{\pm}0.64$, $0.57{\pm}0.55$, $0.49{\pm}0.49$ joule/L, respectively, p=0.0001). PTP was also decreased in CPAP mode($300{\pm}216$, $217{\pm}165$, $179{\pm}187$, $122{\pm}114cm$ $H_2O{\cdot}sec/min$, respectively, p=0.0001), and in SIMV mode($218{\pm}181$, $178{\pm}157$, $130{\pm}147$, $108{\pm}129cm$ $H_2O{\cdot}sec/min$, respectively, p=0.0017). 2) Different effects of PS on respiratory mechanics in CP AP and SIMV modes By application of PS (0, 5, 10, 15 cm $H_2O$), RR was not changed in CPAP mode($27.9{\pm}6.7$, $30.0{\pm}6.6$, $26.1{\pm}9.1$, $27.5{\pm}5.7/min$, respectively, p=0.505), but it was decreased in SIMV mode ($27.4{\pm}5.1$, $27.8{\pm}6.5$, $27.6{\pm}6.2$, $25.1{\pm}5.4/min$, respectively, p=0.0001). $P_{0.1}$ was reduced in CPAP mode($6.2{\pm}3.5$, $4.8{\pm}2.8$, $4.8{\pm}3.8$, $3.9{\pm}2.5\;cm$ $H_2O$, respectively, p=0.0061), but not in SIMV mode($4.3{\pm}2.1$, $4.0{\pm}1.8$, $3.5{\pm}1.6$, $3.5{\pm}1.9\;cm$ $H_2O$, respectively, p=0.054). $T_1/T_{TOT}$ was decreased in CPAP mode($0.40{\pm}0.05$, $0.39{\pm}0.04$, $0.37{\pm}0.04$, $0.35{\pm}0.04$, respectively, p=0.0004), but not in SIMV mode($0.40{\pm}0.08$, $0.35{\pm}0.07$, $0.38{\pm}0.10$, $0.37{\pm}0.10$, respectively, p=0.287). 3) Comparison of respiratory mechanics between CPAP+PS and SIMV alone at same tidal volume. The tidal volume in CPAP+PS 10 cm $H_2O$ was comparable to that of SIMV alone. Under this condition, the RR($26.1{\pm}9.1$, $27.4{\pm}5.1/min$, respectively, p=0.516), WOB($0.80{\pm}0.85$, 0.97+0.77 joule/L, respectively, p=0.485), $P_{0.1}$($3.9{\pm}2.5$, $4.3{\pm}2.1\;cm$ $H_2O$, respectively, p=0.481) were not different between the two methods, but PTP($179{\pm}187$, $218{\pm}181 cmH_2O{\cdot}sec/min$, respectively, p=0.042) and $T_1/T_{TOT}$($0.37{\pm}0.04$, $0.40{\pm}0.08$, respectively, p=0.026) were significantly lower in CPAP+PS than in SIMV alone. Conclusion: PS up to 15 cm $H_2O$ increased tidal volume, decreased work of breathing and pressure time product in both SIMV and CPAP modes. PS decreased respiration rate in SIMV mode but not in CPAP mode, while it reduced central respiratory drive($P_{0.1}$) and shortened duty cycle ($T_1/T_{TOT}$) in CPAP mode but not in SIMV mode. By 10 em $H_2O$ of PS in CPAP mode, same tidal volume was obtained as in SIMV mode, and both methods were comparable in respect to RR, WOB, $P_{0.1}$, but CPAP+PS was superior in respect to the efficiency of the respiratory muscle work (PTP) and duty cycle($T_1/T_{TOT}$).

  • PDF

The Effect of Continuous Positive Pressure Therapy for Obstructive Sleep Apnea on Quality of Life : A Single-Institution Study (폐쇄성수면무호흡증에 대한 지속적 양압치료가 삶의 질에 미치는 영향 : 단일기관 연구)

  • Shin, Hyun Suk;Choi, Mal Rye;Kim, Shin il;Hong, Se Yeon;Eun, Hun Jeong
    • Sleep Medicine and Psychophysiology
    • /
    • v.27 no.2
    • /
    • pp.56-66
    • /
    • 2020
  • Objectives: In this study, the clinical characteristics of OSA patients and the quality of life before and after CPAP use were compared to determine the degree of improvement in quality of life according to CPAP use. Methods: Age, sex, height, weight, body mass index, Epworth Sleepiness Scale, Modified Mallampatti Score, Montreal Cognitive Assessment-Korean, and Pittsburgh Sleep Quality Index were compared between men and women through medical records. To understand the degree of improvement in quality of life resulting from use of CPAP, a personal telephone call was made to compare the VAS scores for quality of life before and after CPAP use. Results: In height (HT) (Z = -4.525, p < 0.001), weight (BW) (Z = -2.844, p < 0.05), sleep quality (PSQI) (Z = -2.671, p < 0.05), and arousal index (AI) (Z = -2.105, p < 0.05), there was a difference between men and women (p < 0.05). There was no difference in the remaining variables. Cross-analysis (Chi-square test) confirmed a difference between severity and sex of OSA. It has been found that there is no statistically significant order in size according to level-specific severity of OSA for PreCPAP QOL, PostCPAP QOL, CPAPUse Months, and CPAP4Hr/d (%) (p > 0.05). The difference between AHI before and after CPAP was 36.48 ± 21.54 (t = 11.609, p < 0.001) and the difference between QOL before and after CPAP was -25.43 ± 22.06 (t = -7.901, p < 0.001), both of which were significant (p < 0.001). Conclusion: Among OSA patients, there were differences in height (HT), weight (BW), sleep quality (PSQI), arousal index (AI), and severity of OSA between men and women, but the quality of life before and after CPAP was different. However, there was no difference between men and women in quality of life before and after CPAP. In addition, quality of life in OSA patients improved after using CPAP.

Design Concept Value Competitive Research Between Service Provider and Service Receiver (수면무호흡 환자의 양압기 제품서비스디자인 개발에 대한 서비스 제공자와 수혜자가 느끼는 디자인 컨셉 가치 비교연구)

  • Lee, Sung Pil;Jung, Ju Young;Lee, Sang Ki;Hong, Jung Pyo
    • Journal of Service Research and Studies
    • /
    • v.7 no.4
    • /
    • pp.39-50
    • /
    • 2017
  • As a comparative study on the value of design concept between service provider (Developer) and service receiver (Customer) group, the aims of this study was to present a service model focused on Continuous positive airway pressure (CPAP) based on U-health care and user environment. Double Diamond-based methods led to a case study that conducted jointly by the department of otolaryngology in U hospital, Ulsan. By targeted on Sleep Apnea patients from the stage of diagnosis to CPAP treatment, variety of meaningful experiences have been extracted and classified into several types of customers. In the final analysis of the 13 service scenario models, Kano Satisfaction and Potential Customer Satisfaction Improvement Index (PCSI) were conducted with the customers, yet Score Model and Concept Position were evaluated by the service provider groups who engaged in development services. The results of this study showed that 7 items in the total of 12 items reached a consensus of viewpoint on value between service receiver and service provider, which the attributes of the service model are based on user environment. Whereas the other 5 items showed the divergent viewpoint on value which included the attributes of U-healthcare service model.

Influence of Sleep-Related Breathing Disorders on Changes of Cardiovascular Function (수면과 관련된 호흡장애가 심혈관계의 기능 변화에 미치는 영향)

  • Moon, Hwa-Sik
    • Sleep Medicine and Psychophysiology
    • /
    • v.4 no.2
    • /
    • pp.129-139
    • /
    • 1997
  • The data collected to date indicate that sleep-related breathing disorders, including sleep-disordered breathing(sleep apnea) and underlying respiratory system diseases, are one of the important risk factors for cardiovascular dysfunction. Sleep-disordered breathing(sleep apnea) is now recognized as one of the leading causes of systemic hypertension, cardiac arrhythmias, coronary heart disease, pulmonary hypertension, right heart failure, and stroke. Sleep may exert a profound effect on breathing in patients with underlying respiratory system disease including bronchopumonary diseases, chest wall abnormalities, central alveolar hypoventilation syndromes or respiratory neuromuscular disorders. Chronic hypoxia and hypercapnia in these patients may accelerate the development of long term cardiovascular complications such as cardiac arrhythmias, pulmonary hypertension, and right heart failure(cor pulmonale). Several recent studies reported that sleep-related breathing disorders are associated with long-term cardiovascular morbidity and mortality. Careful assessment of respiratory and cardiovascular function in these patients is critical. Aggressive and highly effective treatment of sleep-related breathing disorders using tracheostomy, mechanical ventilation, nasal continuous positive airway pressure therapy(nCPAP), intercurrent oxygen therapy or other interventions can reduce the prevalence of cardiovascular dysfunction and the long-term mortality.

  • PDF