• Title/Summary/Keyword: Contamination

Search Result 5,488, Processing Time 0.033 seconds

Monitoring of fecal contamination in a partly restored urban stream in Seoul, Korea

  • Seo, Eun-Young;Jung, Dawoon;Yong, Seung-Cheon;Park, Rho Young;Lee, Young-Ok;Ahn, Tae-Seok
    • Environmental Engineering Research
    • /
    • v.21 no.2
    • /
    • pp.211-218
    • /
    • 2016
  • Cheonggye-cheon is a partly restored urban stream located in central Seoul. We monitored fecal contamination using three different fecal indicators, total coliforms (TC), fecal coliforms (FC) and E. coli, to assess differences in each indicator on days of varying weather conditions. Presumptive TC, FC and E. coli colonies were identified by their 16S rRNA sequences. The results showed that enumeration of E. coli provided a better reflection of fecal contamination of the stream than TC and FC. The main sources of contamination were the inflow of fecal-polluted groundwater from the vicinity of a subway line and two inflowing streams. The fecal contamination was worsened on days with heavy rain because untreated sewage from a collecting facility flowed into the stream. Moreover, growth potential of fecal indicator (E. coli) in situ induced by algal exudates was measured. Our results suggest that an appropriate standard based on E. coli rather than TC and FC should be established for improving water quality management strategies of Cheonggye-cheon in the future.

AN EXPERIMENTAL STUDY ON THE PORCELAIN POROCITY EXERTED BY THE CONTAMINATION OF THE CERAMO-METAL ALLOY AND LIQUID (도재소부전장금관용 합금과 용액의 오염이 기포발생에 미치는 영향에 관한 실험적 연구)

  • Jeun, Young-Chan;Lee, Ho-Yong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.20 no.1
    • /
    • pp.33-49
    • /
    • 1982
  • This study was undertaken to observe the porcelain porosity exerted by the contamination of the alloy and liquid. The alloy used in this study was Jelstar; liquids were Ceramco Sta-Wet liquid, distilled water and tap water; and Ceramco vacuum porcelain powder was used. The measurements with photomicroscope (x200, Olympus) were made on the porosity, the diameter (mm) of the pores and the numbers of the pores ($No/mm^2$) The results of this study were obtained as follows: 1. In the porosity, the opaque layer contained over 70% of the total porosity, and the porosity was increased about twice in every porcelain layer by the tap water. 2. The contamination of the alloy and liquid caused porosity to increase markedly at the interface of the metal-porcelain. 3. The diameter of the pores were increased about 1.5 times larger by the contaimination of the liquid, and only a slight increase in the opaque layer due to the contamination of the alloy. 4. In the numbers of the pores, there were significant differences according to the contamination of the alloy and the porcelain layer. And the contamination of the liquid caused significant differences only in the opaque layer.

  • PDF

Application of the Detection of External Contamination on Radiation Workers for Bed Type Whole Body Counting Using Monte Carlo Method (몬테카를로 방법을 적용한 bed type 전신계측기의 방사선작업종사자 외부오염 검출 응용)

  • Kim, Jeong-In;Lee, Byoung-Il
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.4
    • /
    • pp.242-245
    • /
    • 2013
  • Monte Carlo method was applied to discriminate the external contamination on radiation workers in nuclear power plants for internal dose assessment generally used with a bed type scanning detector whole body counter. Korean voxel model with internal contamination was used to estimate the detection patterns of whole body scanning. Also, the BOMAB model with various external contamination was assumed to compare with detection of radionuclides inside the human body. From the comparison of detection efficiency between front and back side up, external contamination was easily distinguished.

A Numerical Prediction of Contamination Behavior in a Room under the Turbulent Flow and Pressure-Based Boundary Conditions (난류유동 압력경계조건을 가진 실내공간에서의 오염물질 거동에 관한 수치적 예측)

  • 이재헌;노홍구;김광영;오명도
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.5
    • /
    • pp.1272-1281
    • /
    • 1990
  • A numerical study to predict the contamination behavior in a room being contaminated has been performed. The room with one inlet and three exits, which maintained same pressure at the ceiling, has been chosen as test model. Six sets of calculation have been performed, for one, two or three contamination sources of 1*10$^{-4}$ kg$_{c}$/s strength at two different velocities(0.2m/s, 20m/s). Numerical results show that the number the contamination concentration near the first source increased by every 20%-30% of the maximum concentration for each increase of the contamination source.e.

A Study on the Contamination Criterion Map of Seashore Areas in Korea (전국 해안지역의 오손분포도 산정에 관한 연구)

  • Kim, Joon-Eel;Kim, Dong-Myung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.10
    • /
    • pp.89-96
    • /
    • 2008
  • The objective of this study is to establish the algorithm for contamination criterion map based on the recent weather condition. Present criterion was established by the study on the countermeasure of salt contamination for electrical equipment. It did not represent recent weather condition. Therefore it is necessary to develop a contamination criterion map for assessment of contamination in design areas in Korea. To develop contamination criterion map of seashore areas, we used relational numerical formula based on past measurement data with the amount of rainfall, geomorphic variables(elevation slope, land use). These results are expected to be used as a reference material for design distribution facilities in seashore areas.

Microbial Contamination of Masks Worn by Healthcare Professionals (일부 의료기관 종사자가 사용한 마스크의 미생물 오염 사례)

  • Hyekyung Seo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.4
    • /
    • pp.395-402
    • /
    • 2023
  • Objectives: Microbial contamination of face masks used by healthcare professionals can vary depending on the degree of exposure to bioaerosols in various healthcare environments. However, research on this topic is limited. Therefore, we analyzed microbial contamination of N95 respirators used in hospital offices, wards, and outpatient settings. Methods: Samples isolated from N95 respirators worn for 2, 4, and 6 hours were incubated at a temperature of 35-37℃ or 25-28℃ for 24 hours or for 3-7 days, and colony-forming units were counted in chocolate agar, tryptic soy agar, and Sabouraud dextrose agar plates. Total indoor airborne bacteria were also measured in the healthcare environments. Finally, microbial species were identified using Gram staining with a microscopic speculum. Results: The three types of environments did not deviate from the maintenance of standard indoor air quality. There was no difference between the microbial species identified in the healthcare environment and mask contamination. However, the number of bacteria in the masks worn in each environment differed, and the degree of contamination increased with mask-wearing time (p<0.05). Conclusions: Therefore, care must be taken to avoid recontamination of masks due to improper use and exposure to biological hazards in healthcare environments. In conclusion, scientific evidence is necessary for safe mask-wearing times. Based on the results of this study, we hope to conduct further research to establish guidelines for the safe use of face masks during respiratory disease epidemics.

Investigation of Hygiene Indicator Organisms and Listeria monocytogenes Contamination in Smoked Salmon Oncorhynchus keta Distributed in Korea (국내 유통 중인 훈제 연어(Oncorhynchus keta)의 위생지표세균 및 Listeria monocytogenes 오염도 조사)

  • Su-Jeong Lee;Eun-Woo Lee;Won Je Jang
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.56 no.5
    • /
    • pp.721-727
    • /
    • 2023
  • This study was conducted to evaluate the level of microbial contamination in smoked salmon products sold in hypermarkets in major metropolitan cities in Korea. Listeria monocytogenes is the primary cause of smoked and raw salmon product recalls. Here, we used L. monocytogenes as a bacterial hygiene indicator and investigated the microbial contamination level of frozen/refrigerated smoked salmon products collected from hyper markets. Contamination levels were analyzed by seasons, manufacturers, and consumption regions. For hygiene indicator bacteria, total bacteria count, coliforms, and Escherichia coli were examined according to the food code established by the Ministry of Food and Drug Safety, and polymerase chain reaction (PCR) was performed to detect Listeria sp. The highest contamination level was observed in spring in Busan among five consumption regions. Listeria was detected at a level of 2.1% among all samples collected. And especially L. monocytogenes was detected in two cases from the samples collected from Daegu and Daejeon. Sanitary standards and specifications should be established according to the contamination level of smoked salmon products investigated in this study, and continuous monitoring is necessary.

Conceptual Design and Development of an Automatic Classification System According to Radioactive Contamination Level Measurement and Contamination of Radioactive Metal Waste (방사성 금속폐기물의 방사능 오염도 측정 및 오염 여부에 따른 자동 분류 시스템 개념설계 및 개발)

  • Sun Beom Kwon;Bo Gil Kim;Jeong Min Yeom;Gyeong Mo Lee;Hong Yeon Lee;Sang Jun Han
    • Journal of Radiation Industry
    • /
    • v.17 no.1
    • /
    • pp.11-17
    • /
    • 2023
  • Waste generated during the dismantling of nuclear power plants is not only diverse in types such as metal, concrete, soil, but also in a large amount, requiring systematic and efficient management. It is very important to quickly and accurately measure radioactive contamination of wastes generated simultaneously at the decommissioning site, classify them by level, and make decisions so that they can be disposed of in accordance with related laws and regulations. In this paper, for the technical and economic aspects of recycling of radioactive metal waste generated during the dismantling of nuclear power plants, we propose a management system that can measure the radioactive contamination by shape of metal waste at the decommissioning site and automatically classify it according to the presence or absence of contamination. Accordingly, a system for collecting information on metal samples such as weight measurement and shape acquisition of metal waste, measurement of radioactive contamination and identification of nuclides, and an automatic classification system according to radioactivity measurement results were described.

Visualization and contamination analysis for groundwater quality of CDEWSF in Gwangju area using statistical method (통계적 기법을 이용한 광주지역 민방위비상급수용 지하수 수질 오염도 분석 및 시각화 연구)

  • Jang, Seoeun;Lee, Daehaeng;Kim, Jongmin;Kim, Haram;Jeong, Sukkyung;Bae, Seokjin;Cho, Younggwan
    • Analytical Science and Technology
    • /
    • v.31 no.3
    • /
    • pp.122-133
    • /
    • 2018
  • In this study, groundwater quality data measured for 11 years from 2006 to 2016 were analyzed statistically for 101 civil defense emergency water supply facilities (CDEWSF) in the Gwangju area. The contamination level was quantified into four grades by using excess drinking water quality standards, average concentration analysis, and tendency analysis results for each facility. On the basis of this approach, the groundwater contamination degree of each item was evaluated according to land use status, installation year, depth, and geological distribution. The contamination grade ratios, which were obtained by analyzing three contamination indicators (water quality exceeded frequency, average concentration analysis, and trend analysis) for 15 items on statistically significant of civil defense emergency water was relatively high, in the order of Turbidity (51.5 %) > Color (32.7 %) > Nitrate nitrogen (28.7 %) > Hardness (25.7 %). As a result of the contamination grade analysis, except for the items of Turbidity, Color, and Nitrate nitrogen, the contamination levels were distributed in various degrees from "clean (0)" to "seriously contaminated (3)." Regarding the contamination grade of 12 items, 25 % of the total were classified as "possibly contaminated (1)," and 75 % were rated "clean (0)." The four items (Turbidity, Color, Nitrate nitrogen, and Hardness) for which contamination indication rate were evaluated as "high" by the were visualized on a contamination map.

Experimental Study on Fabrication of AZO Transparent Electrode for Organic Solar Cell Using Selective Low-Temperature Atomic Layer Deposition (저온 선택적 원자층 증착공정을 이용한 유기태양전지용 AZO 투명전극 제조에 관한 실험적 연구)

  • Kim, Ki-Cheol;Song, Gen-Soo;Kim, Hyung-Tae;Yoo, Kyung-Hoon;Kang, Jeong-Jin;Hwang, Jun-Young;Lee, Sang-Ho;Kang, Kyung-Tae;Kang, Heui-Seok;Cho, Young-June
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.6
    • /
    • pp.577-582
    • /
    • 2013
  • AZO (aluminum-doped zinc oxide) is one of the best candidate materials to replace ITO (indium tin oxide) for TCOs (transparent conductive oxides) used in flat panel displays, organic light-emitting diodes (OLEDs), and organic solar cells (OSCs). In the present study, to apply an AZO thin film to the transparent electrode of an organic solar cell, a low-temperature selective atomic layer deposition (ALD) process was adopted to deposit an AZO thin film on a flexible poly-ethylene-naphthalate (PEN) substrate. The reactive gases for the ALD process were di-ethyl-zinc (DEZ) and tri-methyl-aluminum (TMA) as precursors and H2O as an oxidant. The structural, electrical, and optical characteristics of the AZO thin film were evaluated. From the measured results of the electrical and optical characteristics of the AZO thin films deposited on the PEN substrates by ALD, it was shown that the AZO thin film appeared to be comparable to a commercially used ITO thin film, which confirmed the feasibility of AZO as a TCO for flexible organic solar cells in the near future.