• Title/Summary/Keyword: Contact lines

Search Result 200, Processing Time 0.04 seconds

Active Control of a High-Speed Pantograph using LQ-Servo Controller

  • Shin, Seung-Kwon;Song, Young-Soo;Eum, Ki-Young;Koo, Dong-Hoe
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1173-1177
    • /
    • 2004
  • The high investment is necessary for the new high speed lines. So the KRRI was interested in the possibility of upgrading the existing line in order to speed up the train in the conventional lines. The tilting train system has been developed because the reconstruction of railway for the cant compensation costs very high. The purpose of the tilting system is to compensate the centrifugal acceleration in order to reduce the lateral acceleration of the passenger at high speed on the curves.The pantograph of the tilting train is indispensable in order to supply the electrification equipments with power in safe. The dynamic interaction between the pantograph and the overhead catenary system causes the variation of the contact force and the contact force variation can cause contact losses, arcing and sparking. If the spark happens between the pantograph and the overhead catenary system, the EMI(electro magnetic interface) and noises may occur. After all, the quality of current collection is deteriorated. This paper deals with the active control of pantograph and presents the LQ-servo controller to reduce the contact force variation.

  • PDF

Countermeasures to prevent contact between phases on overhead lines (가공송전선로 상(相)간 혼촉으로 인한 고장 예방 대책)

  • Park, Yoon-Seok;Kim, Yong-Rak;Kim, Ho-Ki;Kim, Won-Jin;Choi, Jin-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.109-110
    • /
    • 2007
  • Most transmission lines pass through mountainous terrain and deep valleys, to avoid populated areas. Accordingly, the impact of climate changes, environmental conditions and system expansion have caused an increase in transmission line system fault rates. KEPCO has developed and applied phase-spacers to reduce contact faults between phases. Contact between phases represented 9% of total line faults before the devices were installed. Phase-spacers have reduced faults by up to 3.4% since the phase-spacers were installed in 2005. Also, recently developed devices provide additional economic benefits as they cost about a third of the price as similar devices introduced in foreign countries. Phase-spacers are an effective way to prevent phase contact accidents by maintaining physical space between phases. These spacers will be implemented in areas where contacts are likely to occur. They are expected to reduce accident rates and improve power quality.

  • PDF

Analysis for the dynamic responses of pantograph-overhead contact line coupled system by using a condition monitoring system (상태감시시스템을 이용한 팬터그래프-전차선로 동특성 분석에 관한 연구)

  • Cho, Yong-Hyeon;Park, Young;Lee, Ki-Won;Kwon, Sam-Young;Park, Hyun-June
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.778-781
    • /
    • 2008
  • The aim of this paper is to analyze the dynamic responses of pantograph-overhead contact line coupled system by using a condition monitoring system. The monitoring items are strain, vertical displacement and acceleration of a contact wire. Both strain and vertical displacement in the contact wire depends on uplift force and train velocity. Measurement of acceleration shows that the passage of the pantograph gives an impact force to a hard point on a contact wire.

  • PDF

Implement of Dynamic Performance Measurement System Between Pantograph and Contact wire in Tunnel (터널구간 팬터그래프와 전차선간 동적성능 검측장치 구현)

  • Park, Young;Park, Chul-Min;Lee, Ki-Won;Kwon, Sam-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.11
    • /
    • pp.1732-1736
    • /
    • 2012
  • To increase speed up of train, in the field of catenary system, it is necessary to develop of new monitoring methods for dynamic interaction between pantograph and contact wire. Also, there is a need to develop technologies that constantly measure are from various railway structure such as uplift of contact wire, vibration of catenary, dynamic strain of contact line in tunnel. In this paper condition monitoring systems for dynamic performance of catenary systems in tunnel were proposed. An advanced method and results of field tests using high speed camera for monitoring of vertical upward movement of the grooved contact wire due to the force produced from the pantograph were presented. The proposed uplift measurement system of contact wire is expected to enhance precision of current collection quality performance assessment methods at high-speed lines.

Two-dimensional Numerical Simulation of the Contact Angle and the Bubble Necking Using the Two Phase Lattice Boltzmann Method (2상 격자 볼츠만 방법을 이용한 접촉각과 Bubble Necking 2차원 수치 모사)

  • Ryu, Seung-Yeob;Kim, Jae-Yong;Ko, Sung-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.3
    • /
    • pp.10-17
    • /
    • 2011
  • Free energy based lattice Boltzmann method (LBM) has been used to simulate the contact angle and the bubble necking with large density ratio. LBM with the proper contact angle model is able to reduce the spurious currents and eliminate the singularity in the contact lines. The numerical results of the contact angles are satisfied with the Youngs law. For bubble necking flows, simulations are executed for various viscosities and contact angles. The phenomena of the bubble necking are simulated successfully and the subsequent results are presented. The present method is also applicable to the nucleate boiling flows.

A study on vibrational characteristics of the overhead-line (가선시스템의 진동특성 연구)

  • Lee Eung-Shin;Cho Yong-Hyeon;Park Sung-Yong;Jeon Byung-Uk;Lee Jang Mu
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.152-157
    • /
    • 2005
  • Recently, higher speeds have been promoted in old overhead-lines. For high-speed operation in electric railways, increasing contact loss of the pantograph is one of the most important subjects. The contact loss causes power interruption and increases wear of contact strips and contact wires. In order to investigate the causes of contact loss and to work out effective improvement methods, theoretical analyses, experiments have been carried out. First of all, the wave propagating velocity (phase velocity) and characteristics of contact wire are one of the important indices for the current collecting performance. In this paper, mathematical formula arc derived for the prediction of the traveling wave velocity. The measured values in the experiment agree well with the theoretical predictions.

  • PDF

A simulation study on predicting current collection performance with respect to the contact wire tension in 400km/h test run of the next high speed train HEMU-400X (차세대 고속철도 최고속도 시험에서 전차선 장력 증가 단계별 집전 성능 예측 시뮬레이션)

  • Kwon, Sam-Young;Park, Chun-Soo;An, Seung-Hwa
    • Proceedings of the KSR Conference
    • /
    • 2009.05b
    • /
    • pp.201-206
    • /
    • 2009
  • In the testing stage of HEMU-400X(next Korean high speed train) developing project, maximum speed(400km/h) tests will be conducted. On present and near future conditions of the overhead contact lines, 400km/h is over the design speed criteria. The predictions of current collection performance including the percentage loss of contact(arcs level) parameter through dynamic interaction simulation of HEMU-400X maximum speed test run are described in this paper. Various simulations are conducted at the condition of two different contact wire tensions to draw the proper contact wire increasing values in the 400km/h test line under the available contact wire tension supporting condition of that line.

  • PDF

Three-Dimensional Contact Dynamic Model of the Human Knee Joint During Walking

  • Mun, Joung-Hwan;Lee, Dae-Weon
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.2
    • /
    • pp.211-220
    • /
    • 2004
  • It is well known that the geometry of the articular surface has a major role in determining the position of articular contact and the lines of action for the contact forces. The contact force calculation of the knee joint under the effect of sliding and rolling is one of the most challenging issues in this field. We present a 3-D human knee joint model including sliding and rolling motions and major ligaments to calculate the lateral and medial condyle contact forces from the recovered total internal reaction force using inverse dynamic contact modeling and the Least-Square method. As results, it is believed that the patella, muscles and tendon affect a lot for the internal reaction forces at the initial heel contact stage. With increasing flexion angles during gait, the decreasing contact area is progressively shifted to the posterior direction on the tibia plateau. In addition, the medial side contact force is larger than the lateral side contact force in the knee joint during normal human walking. The total internal forces of the knee joint are reasonable compared to previous studies.

Implementation of Electrical Property Assessment System for Overhead Contact Lines (전차선로 전기적 특성 평가 시스템 구현)

  • Oh, Seok-Yong;Park, Young;Cho, Yong-Hyeon;Lee, Ki-Won;Song, Joon-Tae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.6
    • /
    • pp.497-503
    • /
    • 2011
  • Currently in Korea, the simple catenary type overhead contact line system is being applied to both conventional lines and high speed lines of electric railway, and circulation current flowing into the catenary system frequently bring undesirable consequences. Namely, the connector wire has many problems according to a flow of excessive circulation current and arc current on catenary when an electric train runs at high speed. This paper presents the development and application of a real-time data acquisition system designed to measure the electrical characteristics of an overhead catenary system in electric railways. The developed system is capable of storing data of a 25 kV power source in a live wire state through a telemetry environment. The field test results show that the proposed technique and the developed system can be practically applied to measure characteristics of current of an overhead catenary system.

Tomographic PIV measurement of internal complex flow of an evaporating droplet with non-uniformly receding contact lines

  • Kim, Hyoungsoo;Belmiloud, Naser;Mertens, Paul W.
    • Journal of the Korean Society of Visualization
    • /
    • v.14 no.2
    • /
    • pp.31-39
    • /
    • 2016
  • We investigate an internal flow pattern of an evaporating droplet where the contact line non-uniformly recedes. By using tomographic Particle Image Velocimetry, we observe a three-dimensional azimuthal vortex pair that is maintained until the droplet is completely dried. The non-uniformly receding contact line motion breaks the flow symmetry. Finally, a simplified scaling model presents that the mechanical stress along the contact line is proportional to the vorticity magnitude, which is validated by the experimental results.