• Title/Summary/Keyword: Constructions

Search Result 1,404, Processing Time 0.032 seconds

Prediction of Traffic Congestion in Seoul by Deep Neural Network (심층인공신경망(DNN)과 다각도 상황 정보 기반의 서울시 도로 링크별 교통 혼잡도 예측)

  • Kim, Dong Hyun;Hwang, Kee Yeon;Yoon, Young
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.18 no.4
    • /
    • pp.44-57
    • /
    • 2019
  • Various studies have been conducted to solve traffic congestions in many metropolitan cities through accurate traffic flow prediction. Most studies are based on the assumption that past traffic patterns repeat in the future. Models based on such an assumption fall short in case irregular traffic patterns abruptly occur. Instead, the approaches such as predicting traffic pattern through big data analytics and artificial intelligence have emerged. Specifically, deep learning algorithms such as RNN have been prevalent for tackling the problems of predicting temporal traffic flow as a time series. However, these algorithms do not perform well in terms of long-term prediction. In this paper, we take into account various external factors that may affect the traffic flows. We model the correlation between the multi-dimensional context information with temporal traffic speed pattern using deep neural networks. Our model trained with the traffic data from TOPIS system by Seoul, Korea can predict traffic speed on a specific date with the accuracy reaching nearly 90%. We expect that the accuracy can be improved further by taking into account additional factors such as accidents and constructions for the prediction.

Analysis of Greenhouse Gas Reduction Potentials in a University using Bottom-up Model (상향식 모형을 이용한 대학의 온실가스 감축 잠재량 평가)

  • Yoo, Jung-Hwa;Park, Nyun-Bae;Jo, Mi-hyun;Jeon, Eui-Chan
    • Journal of Climate Change Research
    • /
    • v.3 no.3
    • /
    • pp.183-193
    • /
    • 2012
  • In this study, the S University's energy usage, greenhouse gas emissions situation and potential reduction amount were analyzed using a long-term energy analysis model, LEAP. In accordance with the VISION 2020 and university's own improvement plans, S University plans to complete a second campus through expansion constructions by 2020 and by allocating the needed land. Accordingly, increases in energy usage and greenhouse gas emissions seem inevitable. Hence, in this study, the calculations of potential reduction amount by 2020 were attempted through the use of LEAP model by categorizing the energy used based on usage types and by proposing usage typebased reduction methods. There were a total of 4 scenarios: a standard scenario that predicted the energy usage without any additional energy reduction activity; energy reduction scenario using LED light replacement; energy reduction scenario using high efficiency building equipment; and a scenario that combines these two energy reduction scenarios. As scenario-based results, it was ascertained that, through the scenario that had two other energy reduction scenarios combined, the 2020 greenhouse gas emissions amount would be 14,916 tons of $CO_2eq$, an increase of 43.7% compared to the 2010 greenhouse gas emissions amount. Put differently, it was possible to derive a result of about 23.7% reduction of the greenhouse gas emissions amount for S University's greenhouse gas emissions amount through energy reduction activities. In terms of energy reduction methods, changing into ultra-high efficiency building equipment would deliver the most amount of reduction.

Vegetation and Water Characteristics of an Eco-technological Water Purifying Biotope in Yongin (용인시에 위치한 생태공학적 수질정화 비오톱의 식생 및 수환경 특성)

  • Nam, Bo Eun;Kim, Jae Geun;Hong, Mun Gi
    • Journal of Wetlands Research
    • /
    • v.20 no.4
    • /
    • pp.432-445
    • /
    • 2018
  • Vegetation and water characteristics of an eco-technological water purifying biotope were investigated at five years after the wetland construction. A total of 91 vascular plant species in 36 families were recorded. Initially planted emergent macrophytes such as Phragmites australis, P. japonicus, Zizania latifolia, Typha latifolia, and T. angustifolia mainly comprised the vegetational components of the wetland. The effect of water purification was observed markedly in most indicators such as electric conductivity (P < 0.01), $NO_3-N$ (P < 0.05), $NH_4-N$ (P < 0.001), $K^+$ (P < 0.05), $Na^+$ (P < 0.01), and $Mg^{2+}$ (P < 0.01). In particular, $NO_3-N$ and $NH_4-N$ concentrations decreased to about 60% and 30%, respectively, via the purification process of the wetland. Separativeness and curvature from the meandering structure of 15 units (multi-cell wetland system) seemed likely to make the wetland continuously play a role as an eco-technological water purifying biotope. We recommend that eco-technological design factors should be included in wetland constructions for efficient and continuous functioning, thus enhancing ecological values of wetlands.

A Study on Estimation of End Bearing Capacity of a PHC-W Pile in Building Underground Additional Wall Using the PHC-W Earth Retaining Wall (PHC-W 흙막이 벽체를 이용한 건축물 지하증설벽체에서 PHC-W말뚝의 선단지지력 산정에 관한 연구)

  • Kim, Chea Min;Yun, Daehee;Lee, Chang Uk;Johannes, Jeanette Odelia;Kim, Sung Su;Choi, Yongkyu
    • Journal of the Korean Geotechnical Society
    • /
    • v.35 no.3
    • /
    • pp.5-16
    • /
    • 2019
  • With the recent concentration of urban populations, the constructions of large structures are increasing, along with the development of foundations for large structures. PHC Piles have been used in many structures ever since Japanese introduced the technology at the end of the 20th century. Recently, many studies on the use of the PHC Pile have been carried out as earth retaining using the merits of PHC piles. In this study, static axial compression tests were conducted on the PHC-W piles constructed as column-type in building underground additional wall using the PHC-W earth retaining wall. The end bearing capacity of pile was calculated using the axial load transfer measurement that was obtained from the static axial compression test result. Since end bearing capacity of the PHC-W pile embedded in weathered rock showed a different behaviour from the conventional PHC pile, the calculation method of end bearing capacity for column-type PHC-W piles would be proposed. The unit ultimate end bearing equation proposed for single and group PHC-W pile embedded in weathered rock is $q_b=13.3N_b$ and $q_b=6.8N_b$.

Analysis and cause of defects in reinforced cement concrete lining on NATM tunnel based on the Precise Inspection for Safety and Diagnosis - Part I (정밀안전진단 결과를 활용한 NATM (철근)의 라이닝 결함 종류별 발생원인 및 분석 - Part I)

  • Choo, Jinho;Lee, Inmo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.1
    • /
    • pp.1-29
    • /
    • 2019
  • Related to the previous paper on the typical crack pattern of tunnel lining with NATM, the characteristic defects in reinforced cement concrete lining of NATM tunnel have analyzed with the precise inspection with safety and diagnosis (PISD) by KISTEC. Depending on the reinforcing materials, steel rebar, steel fiber, and glass fiber have been implemented to reinforcing lining in various NATM tunnel constructions. Reinforcing lining with rebar are prevailed on NATM tunnel to countermeasure the weak geological circumstances, to pursuit the economical tunnel sections, and to resist the risk of tunnel deterioration. By the special act on the safety control of public facilities, the reinforced NATM tunnels for more than 1 km length are scrutinized closely to characterize defects; crack, reinforcement exposure, and lack of lining. Crack resistance by reinforcing is shown in comparison with the normalized crack to the length of tunnel. Typical exposed reinforcements in lining have exemplified with various sections. The lack of lining due to the mal-construction, spalling, fire, earthquake and leaching has been analyzed. The cause and mechanism with the field inspections and other studies has also been verified. Detailed cases are selected by the above concerns as well as the basic information from FMS (Facilities Management System). Likewise the previous paper, this study provides specialized defects in reinforced lining of NATM and it can be widely used in spreading the essential technics and reporting skills. Furthermore, it would be advised and amended for the detail guideline of Safety Diagnosis and PISD (tunnel).

A Comparison of the Effects of Silica and Hydroxyapatite Nanoparticles on Poly(ε-caprolactone)-Poly(ethylene glycol)-Poly(ε-caprolactone)/Chitosan Nanofibrous Scaffolds for Bone Tissue Engineering

  • Hokmabad, Vahideh Raeisdasteh;Davaran, Soodabeh;Aghazadeh, Marziyeh;Alizadeh, Effat;Salehi, Roya;Ramazani, Ali
    • Tissue Engineering and Regenerative Medicine
    • /
    • v.15 no.6
    • /
    • pp.735-750
    • /
    • 2018
  • BACKGROUND: The major challenge of tissue engineering is to develop constructions with suitable properties which would mimic the natural extracellular matrix to induce the proliferation and differentiation of cells. Poly(${\varepsilon}$-caprolactone)-poly(ethylene glycol)-poly(${\varepsilon}$-caprolactone) (PCL-PEG-PCL, PCEC), chitosan (CS), nano-silica ($n-SiO_2$) and nano-hydroxyapatite (n-HA) are biomaterials successfully applied for the preparation of 3D structures appropriate for tissue engineering. METHODS: We evaluated the effect of n-HA and $n-SiO_2$ incorporated PCEC-CS nanofibers on physical properties and osteogenic differentiation of human dental pulp stem cells (hDPSCs). Fourier transform infrared spectroscopy, field emission scanning electron microscope, transmission electron microscope, thermogravimetric analysis, contact angle and mechanical test were applied to evaluate the physicochemical properties of nanofibers. Cell adhesion and proliferation of hDPSCs and their osteoblastic differentiation on nanofibers were assessed using MTT assay, DAPI staining, alizarin red S staining, and QRT-PCR assay. RESULTS: All the samples demonstrated bead-less morphologies with an average diameter in the range of 190-260 nm. The mechanical test studies showed that scaffolds incorporated with n-HA had a higher tensile strength than ones incorporated with $n-SiO_2$. While the hydrophilicity of $n-SiO_2$ incorporated PCEC-CS nanofibers was higher than that of samples enriched with n-HA. Cell adhesion and proliferation studies showed that n-HA incorporated nanofibers were slightly superior to $n-SiO_2$ incorporated ones. Alizarin red S staining and QRT-PCR analysis confirmed the osteogenic differentiation of hDPSCs on PCEC-CS nanofibers incorporated with n-HA and $n-SiO_2$. CONCLUSION: Compared to other groups, PCEC-CS nanofibers incorporated with 15 wt% n-HA were able to support more cell adhesion and differentiation, thus are better candidates for bone tissue engineering applications.

Study on the Changes in Riverfront Landscape of Taehwa River, Ulsan City (울산시 태화강 수변 경관 변천에 관한 연구)

  • Jeung, Min-Ki;Han, Sam-Geon
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.8
    • /
    • pp.117-128
    • /
    • 2018
  • The central of Ulsan was formed and has been developed in alluvial plains the Riverfront of Taehwa River and Dongcheon River Fortresses including Gyebyeonseong of the late Silla, Chisoseong of the Goryeo, Ulsan Gyeonsangjwabyeongyeongseong, Ulsaneupseong, Ulsanwaeseong and Yeompoyeongseong as well as Gugangseowon and Old Ulsanhyanggyo and other facilities well display such fact. In the southern areas of Taehwa River, Byeokpajeong of Samsan, Buddhist temples and pavilion architectures used to be located. In its upstream areas, Eonyangeupseong, Eonyanghyanggo, Banguseowon and Daegokcheon Petroglyph exist as well. As such, the Riverfront of Taehwa River are a central space where the civilization of Ulsan has grown and developed, and are regarded as a core scenic asset of Ulsan. However, the look and nature of Taehwa River changed significantly due to Ulsan irrigation project and the construction of modern bridges such as Ulsangyo and Ulsan railway bridge during the period of Japanese occupation. The old look of the area started to be ruined by water contaminations and developments of waterfront lands that resulted from the development of Ulsan Industrial Center in 1962. The water quality of Taehwa River has been improved as a result of allotting a huge budget and administrative powers before and after 1997, the year when Ulsan was elevated to a metropolitan city. However, the surrounding views around Taehwa River changed greatly due to various urban development projects including apartment complex constructions. This is because the development of the Riverfront started from a land utilization project, in which the construction of apartment complexes was included in the initial phase; as a result, the areas were changed to be private scenic assets for those apartments. Aware of such issue, this study aims to identify major scenic elements that were present in the period before such developments in the river's surrounding areas from literature and geography materials; and to reveal how various urban development projects that have been performed from the period of Japanese occupation have changed the scenic elements of Riverfront of Taehwa River. The purpose of this study is to identify qualitative and quantitative changes in scenic elements of the Riverfront of Taehwa River as well as the characteristics of the resulting changes in the surrounding scenery.

A Study on Lateral Displacement of Caisson Constructed on Improved Ground (개량 지반에 설치된 케이슨의 측방변위에 대한 연구)

  • Kim, Myunghak;Lee, Sangwook;Yoon, Minseung;Han, Byungwon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.4
    • /
    • pp.33-41
    • /
    • 2011
  • In case of building up port facilities on soft ground, unsymmetrical surcharge of embankment, which make the excess pore water pressure to increase, causes to occur lateral displacement due to plasticity of soil. A study on lateral displacement and settlement of the caisson, which is installed on improved ground, was accomplished. The field measurement data and calculated values obtained from FEM program of Plaxis were compared and analyzed. For numerical analysis, the properties of soils, constructions stage and time were considered. Lateral displacement was measured at the point of inclinometers installed in front of caisson. Settlement was measured at the center of extra embankment behind of caisson. Comparison of measured and calculated for lateral displacement showed that the calculated value was greater than the measured, and increasing trend was different. The calculated value showed step increasing as step extra embankment applied, whereas the measured gradually was increased. For settlement of embankment, the amount of both measured and calculated were similar, but the trend was different like that of lateral movement.

A Study on the Analysis of the Relaxation Area and the Improvement Effect of the Ground by Road Subsidence (지하연속벽 배면 도로의 지반침하에 따른 이완영역분석방법과 지반 보강 효과검증에 관한 연구)

  • Lee, Hyoung Kyu;Lee, Yong-Sun
    • Journal of the Korean Geotechnical Society
    • /
    • v.37 no.1
    • /
    • pp.29-41
    • /
    • 2021
  • Although underground works are essential to use underground spaces in urban areas efficiently, various damages caused by constructions have often occurred, making them major social problems. Since 2018, it is stipulated in the Special Act on Underground Safety Management that appropriate construction methods must be used in the design stage to prevent various damage cases. This Special Act includes establishing an area subject to underground safety impact assessment, analysis of ground and geological status, review of effects caused by changes in groundwater, review of ground safety, and establishment of measures to secure underground safety. This study area consists of various strata in order of landfill, sedimentary silt, sedimentary sand, sedimentary gravel, weathering zone, and foundation rock. Also, the slurry wall, a highly rigid underground continuous wall, was chosen as a construction method to consider high water table distribution and minimize the influence of the surroundings in this area. However, ground subsidence occurred on the road nearby in December 2019 due to the inflow of loosening soil to the construction area. Thus, several types of site investigations were conducted to suggest an appropriate analysis method and to find out loosed ground behavior and its area for the subsided site. As a result, new design soil properties were re-calculated, and the reinforcement measures were proposed through analytical verification.

A Study on Improving the Data Quality Validation of Underground Facilities(Structure-type) (지하시설물(구조물형) 데이터 품질검증방법 개선방안 연구)

  • Bae, Sang-Keun;Kim, Sang-Min;Yoo, Eun-Jin;Im, Keo-Bae
    • Journal of Cadastre & Land InformatiX
    • /
    • v.51 no.2
    • /
    • pp.5-20
    • /
    • 2021
  • With the available national spatial information that started from the sinkholes that occurred nationwide in 2014 and integrated 15 areas of underground information, the Underground Spatial Integrated Map has been continuously maintained since 2015. However, until recently, as disasters and accidents in underground spaces such as hot water pipes rupture, cable tunnel fires, and ground subsidence continue to occur, there is an increasing demand for quality improvement of underground information. Thus, this paper attempted to prepare a plan to improve the quality of the Underground Spatial Integrated Map data. In particular, among the 15 types of underground information managed through the Underground Spatial Integrated Map, quality validation improvement measures were proposed for underground facility (structure-type) data, which has the highest proportion of new constructions. To improve the current inspection methods that primarily rely on visual inspection, we elaborate on and subdivide the current quality inspection standards. Specifically, we present an approach for software-based automated inspection of databases, including graphics and attribute information, by adding three quality inspection items, namely, quality inspection methods, rules, and flow diagram, solvable error types, to the current four quality inspection items consisting of quality elements, sub-elements, detailed sub-elements, and quality inspection standards.