• Title/Summary/Keyword: Constant Comparison Method

Search Result 373, Processing Time 0.03 seconds

Study on the Use of the Constant Comparison Method : Lessons from Training Novice Modelers (지속비교 방법에 관한 연구 : 초심 모델러 교육으로부터의 교훈)

  • Kim, Taekyung;Park, Jinsoo;Rho, Sangkyu
    • The Journal of Society for e-Business Studies
    • /
    • v.18 no.1
    • /
    • pp.165-189
    • /
    • 2013
  • Conceptual modeling is a critical activity for developing successful business information systems. The objective of this study is to evaluate the possibility of applying the constant comparison method from the grounded theory to conceptual modeling. To achieve the objective, we trained novice modelers and split them into two groups for evaluation. The experimental results show that applying the constant comparison method could increase acceptability from more experienced conceptual modelers. Moreover, while the control group was experienced difficulties when domain knowledge is unfamiliar, the experimental group could handle difficulties more effectively. In addition, applying the constant comparison method also decreased the time to complete analysis for conceptual modeling.

Development of an Apparatus for In-situ Vacuum Gauge Calibration (In-situ 진공게이지 교정장치 개발)

  • Hong, S.S.;Lim, I.T.;Jho, M.J.;Chung, W.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.6
    • /
    • pp.605-611
    • /
    • 2006
  • We have developed in-situ vacuum gauge calibration system in the range 1 Pa to 100 kPa by using constant volume method. The system is capable of gauge calibration by comparison method without demount the reference gauges. The system will be useful for dissemination of national vacuum standards to foreign developing countries and domestic industries.

A Comparison of Constant Current and Constant Voltage Control in LED Driver (LED driver에서의 정전류 및 정전압 제어의 비교 연구)

  • Han, Soo-Bin;Park, Suck-In;Jung, Hak-Kun;Song, Eu-Gine;Jung, Bong-Man
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.83-84
    • /
    • 2010
  • This paper reviews the performance difference between constant voltage control and constant current control in LED driver. Simulations of both control methods are performed for performance comparison especially with temperature variation. The results show that constant current control method is inherently better than constant voltage control for LED drive.

  • PDF

Experimental Comparison for Constant e using Spreadsheet (Spreadsheet를 활용한 상수 e의 실험적 비교)

  • 김철수;양영근
    • The Mathematical Education
    • /
    • v.40 no.1
    • /
    • pp.113-123
    • /
    • 2001
  • We investigated an irrational constant e and compared its computational methods using spreadsheet. Such methods are based on classical definition, infinite series, continued fraction, infinite product exponential function and accelerated classical method. This kind of work is focused on experimental mathematics using computers in math class. This approach will be helpful for mathematics teachers to teach constant e in their classroom.

  • PDF

Study on the Simulation of the 4-Stroke Cycle Spark Ignition Engines (First Paper) (4 행정 사이클 스파크 점화기관의 시뮬레이션에 관한 연구 (제1보))

  • 윤건식;우석근;서문진;신승한
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.6
    • /
    • pp.1260-1271
    • /
    • 2001
  • The simulation program which predicts the gas behavior in a spark ignition engine has been developed and verified by the comparison with the experimental results foy the MPI engine, naturally aspirated and turbochared engines with a carburettor. First paper describes the calculations of the behavior of gas in the intake and exhaust system. The generalized method of characteristics including friction, heat transfer, area change and entropy gradients was used to analyse the pipe flow The constant-Pressure model was applied for the analysis of the flow through engine valved, and the constant-pressure perfect-mixing model was applied for the flow at manifold junction. The concept of the sudden area change was used for the muffler and catalytic convertor. Fer the plenum chamber in an MPI engine, constant-pressure model and constant-volume model were both examined. Through the comparison of predicted results with experiments, the simulation program was verified by showing good prediction of the behavior of IC engine qualitatively and quantitatively under wide range of operating conditions.

  • PDF

Estimation of Smoothing Constant of Minimum Variance and Its Application to Shipping Data with Trend Removal Method

  • Takeyasu, Kazuhiro;Nagata, Keiko;Higuchi, Yuki
    • Industrial Engineering and Management Systems
    • /
    • v.8 no.4
    • /
    • pp.257-263
    • /
    • 2009
  • Focusing on the idea that the equation of exponential smoothing method (ESM) is equivalent to (1, 1) order ARMA model equation, new method of estimation of smoothing constant in exponential smoothing method is proposed before by us which satisfies minimum variance of forecasting error. Theoretical solution was derived in a simple way. Mere application of ESM does not make good forecasting accuracy for the time series which has non-linear trend and/or trend by month. A new method to cope with this issue is required. In this paper, combining the trend removal method with this method, we aim to improve forecasting accuracy. An approach to this method is executed in the following method. Trend removal by a linear function is applied to the original shipping data of consumer goods. The combination of linear and non-linear function is also introduced in trend removal. For the comparison, monthly trend is removed after that. Theoretical solution of smoothing constant of ESM is calculated for both of the monthly trend removing data and the non monthly trend removing data. Then forecasting is executed on these data. The new method shows that it is useful especially for the time series that has stable characteristics and has rather strong seasonal trend and also the case that has non-linear trend. The effectiveness of this method should be examined in various cases.

Comparison of Coefficient of Consolidation and Prediction of Excess Pore Water Pressure of Agricultural Reservoir under Embankment on Soft Ground (연약지반상에 축조된 농업용저수지의 과잉공극수압 예측과 압밀계수의 비교)

  • Lee, Dal-Won;Kim, Eun-Ho
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.52 no.2
    • /
    • pp.1-9
    • /
    • 2010
  • This study was carried out to comparison of coefficient of consolidation and the prediction of excess pore water pressure in agricultural reservoir on soft clay ground. For the purpose of verification of the proposed equation, laboratory model tests and field tests were performed and excess pore water pressure was compared to those predicted with the Terzaghi's method. The predicted excess pore water pressure according to ponding was very applicable to practice because it was close to the observed data. Also, for the comparison of coefficient of consolidation, the oedometer, constant rate of strain (CRS), and Rowe cell tests were performed. The coefficient of consolidation at the Rowe cell and CRS tests showed a greate increase than in the oedometer test. The ratio of the vertical and horizontal coefficient of consolidation showed a large difference according to various tests method and mixing ratio. Therefore, it is recommended that careful attention should be paid to predicting the required consolidation period in agricultural reservoir.

Numerical Prediction of Phase Change within the Molten Steel with Thin Slab Casting (박슬라브 주형에 따른 용강내의 상변화현상에 대한 수치적 해석)

  • 최원록;유홍선;최영기
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.3
    • /
    • pp.14-22
    • /
    • 2000
  • A numerical analysis has been performed on the two-dimensional rectangular gallium melting problem using the enthalpy method. The major advantage of this method is that the physical domain is discretized with fixed grids without transforming variables and the interface conditions of phase change are accounted for the definition of suitable source terms in the governing equations. But in the fixed method, there is some ambiguity in defining the porosity constant which has no physical interpretation. If the velocity correction is included in the momentum equation, for the appropriate range of porosity constant, the realistic predictions are obtained. The object of the present work is to predict the phase change within the molten steel with thin riser slab using the modified enthalpy-porosity method. The computational procedures for predicting velocity and temperature are based on the finite volume method and the non-staggered grid system. The influence of natural convection on the melting process is considered. A comparison with the experimental results shows that the modified method is better than the previous one.

  • PDF

Comparison of Numerical Methods for Two-dimensional Wave Breaker on a Plane Beach of Constant Slope (2차원 Beach에서 쇄파의 시뮬레이션을 위한 수치계산기법의 비교)

  • Jeong K. L.;Lee Y.-G.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2004.03a
    • /
    • pp.119-125
    • /
    • 2004
  • Unsteady nonlinear wave motions on the free surface over a plane beach of constant slope are numerically simulated using a finite difference method in rectangular grid system. Two-dimensional Navier-Stokes equations and the continuity equation are used for the computations. Irregular leg lengths and stars are employed near the boundaries of body and free surface to satisfy the boundary conditions. Also, the free surface which consists of markers or segments is determined every time step with the satisfaction of kinematic and dynamic free surface conditions. Moreover, marker-density method is also adopted to allow plunging jets impinging on the free surface. The second-order Stokes wave theory and solitary wave theory are employed for the generation of waves on the inflow boundary. For the simulation of wave breaking phenomena, the computations are carried out with the plane beach of constant slope in surf zone. The results are compared with each other. The marker-density method is better then the hybrid method. Also they are compared with other existing experimental results. The Agreement between the experimental data and the computation results is good.

  • PDF

Comparison of TDC Circuit Design Method to Constant Delay Time

  • Choi, Jin-Ho
    • Journal of information and communication convergence engineering
    • /
    • v.8 no.4
    • /
    • pp.461-465
    • /
    • 2010
  • This paper describes the design method of Time-to-Digital Converter(TDC) to obtain the constant delay time and good reliability. The reliability property is described with delay elements. In TDC the time signal is converted to digital value which is based on delay elements for the time interpolation. To obtain the constant delay time, the first and the last delay elements have different structure compared to the middle delay elements. In the first and the last delay elements, the driving ability could be controlled for the different delay time. The delay element can be designed by analog and digital devices. The delay time of the element using analog devices is not sensitive to process parameters than that of the element using digital devices. And the TDC circuit by the elements using analog devices shows better reliability than that by the elements using digital devices also.