• Title/Summary/Keyword: Consistent

Search Result 9,988, Processing Time 0.038 seconds

Merging Galaxy Cluster Abell 115: Weak Lensing with Subaru Observation

  • Kim, Mincheol;Jee, Myungkook J.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.42 no.2
    • /
    • pp.41.1-41.1
    • /
    • 2017
  • We present weak-lensing analysis of the merging galaxy cluster Abell 115 at z=0.197 based on Subaru i and V band images. As merging clusters often show, Abell 115's merging signatures include radio relics, double X-ray peaks, and large offsets between the cluster member galaxies and the X-ray distributions. A weak-lensing study provides underlying dark matter distribution, the key information to determine the complex merging scenario of the cluster. In this work, we present 2D mass reconstruction of the cluster, which reveals two distinct mass peaks consistent with galaxy distributions. We measure the first weak-lensing mass of each subcluster. Our weak-lensing total mass estimate is a few factors lower than the published dynamical mass obtained from velocity dispersion. This large mass discrepancy may be attributed to a significant departure from dynamical equilibrium. We also re-analyze the archival chandra data and find that the result is consistent with weak-lensing mass.

  • PDF

A Theoretical Study on the Dispersion of Elastic Waves in Particulate Composites (입자복합재료 내부의 탄성파 분산에 관한 이론적 연구)

  • 김진연;이정권
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.7
    • /
    • pp.1697-1704
    • /
    • 1994
  • Elastic wave propagation in discrete random medium studies to predict dynamic effective properties of composite materials containing spherical inclusions. A self-consistent method is proposed which is analogous to the well-known coherent potential approximation. Three conditions that must be satisfied by two effective elastic moduli and effective density are derived for the time without limit of frequency. The derived self-consistency conditions have the physical meaning that the scattering of coherent wave by the constituents in effective medium is vanished on the average. The frequency-dependent complex effective wave speed and coherent attenuation can be obtained by solving the derived self-consistency conditions numerically. The wave speed and attenuation obtained from present theory are shown to be in the better agreements with previous experimental observations than the previous theory.

A Case of Ancylostoma ceylanicum Infection Occurring in an Australian Soldier Returned from Solomon Islands

  • Speare, Rick;Bradbury, Richard Stewart;Croese, John
    • Parasites, Hosts and Diseases
    • /
    • v.54 no.4
    • /
    • pp.533-536
    • /
    • 2016
  • A 26-year-old male member of the Australian Defense Force presented with a history of central abdominal pain of 4 weeks duration and peripheral eosinophilia consistent with eosinophilic enteritis. Acute hookworm disease was diagnosed as the cause. Adult worms recovered from feces after therapy with albendazole were morphologically consistent with Ancylostoma ceylanicum. As the patient had been deployed with the Regional Assistance Mission to Solomon Islands for 6 months prior to this presentation, it is very likely that the A. ceylanicum was acquired in Solomon Islands. Until now, it has been assumed that any Ancylostoma spp. recovered from humans in Solomon Islands is A. duodenale. However, this case demonstrates that human hookworm infection acquired in the Solomon Islands could be caused by A. ceylanicum.

Technical Advances, Image Quality and Quality Control Regulations in Mammography

  • Ng, Kwan-Hoong
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.38-41
    • /
    • 2002
  • Mammography is considered the single most important diagnostic tool in the early detection of breast cancer. Today's dedicated mammographic equipment, specially designed x-ray screen/film combinations, coupled with controlled film processing, produces excellent image quality and can detect very low contrast small lesions. In mammography, it is most important to produce consistent high-contrast, high-resolution images at the lowest radiation dose consistent with high image quality. Some of the major technical development milestones that have let to today's high quality in mammographic imaging are reviewed. Both the American College of Radiology Mammography Accreditation Program and the Mammography Quality Standards Act have significant impact on the improvement of the technical quality of mammographic images in the United States and worldwide. A most recent development in digital mammography has opened up avenues for improving diagnosis.

  • PDF

Electromechanical Relationn of metallic heat wires and Its Application to the Estimation of In_situ Stress of Structural Tendons (금속계열선의 전기기계적 상관작용과 긴장력 계측이 가능한 긴장재)

  • Zi Goang-Seup;Jun Ki-Woo
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2006.04a
    • /
    • pp.445-450
    • /
    • 2006
  • It is proposed that the electromechanical relation of the conductive materials with high electrical resistance may be used to estimate the current stress of prestressing tendons. To choose the best conductive material to this end, we studied the electromechanical relations of carbon fibers and metalic heat wires experimentally. It is found that the relation of carbon fibers can be modelled by a parabolic(or hyperbolic) function in the early stage of deformation. However because the relation is not consistent when it is unloaded and reload, carbon fibers are not suitable for this purpose. Metallic heat wires show a consistent linear relation during loading and unloading in the elastic deformation and are suitable for this purpose. To estimate the electromechanics relation of metallic wires, we developed a simple formula based on the rigid plasticity. We propose a new kind of prestressing tendons whose stress can be monitored.

  • PDF

Small-Sample Inference in the Errors-in-Variables Model (소표본 errors-in-vairalbes 모형에서의 통계 추론)

  • 소병수
    • Journal of Korean Society for Quality Management
    • /
    • v.25 no.1
    • /
    • pp.69-79
    • /
    • 1997
  • We consider the semiparametric linear errors-in-variables model: yi=(${\alpha}+{\beta}ui+{\varepsilon}i$, xi=ui+${\varepsilon}i$ i=1, …, n where (xi, yi) stands for an observation vector, (ui) denotes a set of incidental nuisance parameters, (${\alpha}$ , ${\beta}$) is a vector of regression parameters and (${\varepsilon}i$, ${\delta}i$) are mutually uncorrelated measurement errors with zero mean and finite variances but otherwise unknown distributions. On the basis of a simple small-sample low-noise a, pp.oximation, we propose a new method of comparing the mean squared errors(MSE) of the various competing estimators of the true regression parameters ((${\alpha}$ , ${\beta}$). Then we show that a class of estimators including the classical least squares estimator and the maximum likelihood estimator are consistent and first-order efficient within the class of all regular consistent estimators irrespective of type of measurement errors.

  • PDF

A Note on the Small-Sample Calibration

  • So, Beong-Soo
    • Journal of Korean Society for Quality Management
    • /
    • v.22 no.2
    • /
    • pp.89-97
    • /
    • 1994
  • We consider the linear calibration model: $y_1={\alpha}+{\beta}x_i+{\sigma}{\varepsilon}_i$, i = 1, ${\cdots}$, n, $y={\alpha}+{\beta}x+{\sigma}{\varepsilon}$ where ($y_1$, ${\cdots}$, $y_n$, y) stands for an observation vector, {$x_i$} fixed design vector, (${\alpha}$, ${\beta}$) vector of regression parameters, x unknown true value of interest and {${\varepsilon}_i$}, ${\varepsilon}$ are mutually uncorrelated measurement errors with zero mean and unit variance but otherwise unknown distributions. On the basis of simple small-sample low-noise approximation, we introduce a new method of comparing the mean squared errors of the various competing estimators of the true value x for finite sample size n. Then we show that a class of estimators including the classical and the inverse estimators are consistent and first-order efficient within the class of all regular consistent estimators irrespective of type of measurement errors.

  • PDF

Determinants of Accounting Policy for R&D Costs (연구개발에 대한 회계정책 결정요인 분석)

  • 조성표
    • Journal of Technology Innovation
    • /
    • v.5 no.1
    • /
    • pp.67-89
    • /
    • 1997
  • This study investigates the factors determining accounting method for R&D costs (capitalizevs. expense) in Korea. Using agency theory and other economic factors, probit and regression model have been developed to distinguish between firms choosing different accounting alternatives for R&D costs. The results are consistent to debt contract, R&D burden and regulation hypotheses both in probit and regression analysis. The size variable has opposite sign in univariate t-test and probit analysis, which may be due to the differences of political environment between Korea and the US. Generally, the results are consistent to those of previous research. The evidence suggests that larger firms with higher leverage and larger burden of R&D costs are more likely to capitalize R&D costs, while regulated firms are more likely to expense R&D costs.

  • PDF

Prevalence of Fascioliasis and changes in blood components in slaughtered Korean native cattle of North Kyeongnam area (경남 북부지역에서 도축된 한우의 간질 감염율과 혈액성장의 변화에 관한 연구)

  • 서득록;이국천;이순선;김종수;김충희
    • Korean Journal of Veterinary Service
    • /
    • v.18 no.2
    • /
    • pp.158-162
    • /
    • 1995
  • An abattoir survey was carried out on 300 Korean native cattles reared and slaughtered in North Kyeongnam area to determine the prevalence of Fasciola hepatica infections. The average prevalence of fascioliasis was 46.4% ; the infection rate had a tendency to increase with age. Some hematological and biochemical indices were assayed in Korean native cattle naturally harbouring Fasciola hepatica infection and compared with uninfection control. Affected animal revealed reduction total erythrocyte count and hemoglobin, which was consistent in total leucocyte count and packed cell volume. Infected cattle had lower level of serum total protein and albumin, was consistent serum calcium and glucose indices, had higher levels of SGOT, SGPT and cholesterol indices.

  • PDF

Toward a Self-Consistent Simulation of the Cosmic Reionization

  • An, Gyeong-Jin
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.1
    • /
    • pp.78.2-78.2
    • /
    • 2010
  • Ionization of hydrogen occurs globally in our universe. The epoch of this cosmic reionization may be probed by various observations, among which the 21cm observation of neutral hydrogen at high redshift is the most promising candidate. In order to provide a mock data, we have performed the first, self-consistent simulation of cosmic reionization. We account for all possible UV-radiating sources which reside in halos ranging from minihalos to atomically-cooling halos. In order to simulate the contribution from Pop III objects, we also calculate the radiative transfer of Lyman-Werner radiation and apply a suppression criterion for Pop III objects. Our priliminary result indicates that Pop III objects ionize the universe at very high redshift and create rich, small-scale bubble structure, while sources in atomically-cooling halos ionize the universe at relatively low redshift and create large-scale bubble structure. We discuss how these two different scales and epoch may be probed by future 21cm observations.

  • PDF