• 제목/요약/키워드: Connection rotation capacity

검색결과 79건 처리시간 0.023초

Experimental and Numerical Analysis on Full High Strength Steel Extended Endplate Connections in Fire

  • Qiang, Xuhong;Wu, Nianduo;Jiang, Xu;Luo, Yongfeng;Bijlaard, Frans
    • 국제강구조저널
    • /
    • 제18권4호
    • /
    • pp.1350-1362
    • /
    • 2018
  • Full-scale experimental study and numerical analysis on behaviors and failure mechanisms of full high strength steel extended endplate connections in fire have been carried out and presented in this paper. The experimental behaviors of the connections were compared with the provisions of Eurocode 3. The test results show that the failure modes of the connections in fire are bolt failure with yielding of the flange, as same as those at ambient temperature. The failures of the bolts in fire are ductile while they are brittle at ambient temperature. The rotation capacity of the connections in fire is proved sufficient. What is more, at elevated temperature $550^{\circ}C$, the plastic moment resistances of Q690 and Q960 full high strength steel endplate connections are only 40% of those at ambient temperature, while their initial rotation stiffness are 66 and 63% respectively. But the rotation capacities of Q690 and Q960 high strength steel endplate connections are 1.38 and 1.74 times of those at ambient temperature. Moreover, it is found that the component method Eurocode 3 proposed based on connections made of mild steels can be used to calculate plastic resistances and to predict failure modes of high strength steel endplate connections in fire, but it is not suitable to predict their stiffness. The suggestions about rotation capacity of connections in Eurocode 3 are found too conservative for high strength steel endplate connections in fire.

일체식교량의 접속슬래브 연결철근 형상에 따른 연결부 구조거동에 대한 실험연구 (Experimental Study on the Structural Behavior of Typical Bar Connections of Approach Slab in the Integral Abutment Bridge)

  • 유성근;김나연;김호섭;김현기;김영호
    • 복합신소재구조학회 논문집
    • /
    • 제5권4호
    • /
    • pp.24-35
    • /
    • 2014
  • An experimental study on the structural behavior of connection types between approach slab and integral abutment has been done for three typical bar connections. Typical hinge style reinforcing bar detail for its connection is preferred in order to accommodate rotation of the approach slab among engineers. However, the straight horizontal bars can be used as connection detail accomodate structural capacity. Total six specimens with three types of rebar detail are tested for direct tensile and bending load. The characteristic structural behaviors are carefully monitored and all the strain gauge data obtained are analyzed. It is shown that the structural performance of all the specimens well exceed its design allowance. Several design suggestions are given based on careful reviews on the experiment.

A study of continuous stem girder systems

  • Kim, Boksun;Wright, Howard D.;Cairns, Roy
    • Structural Engineering and Mechanics
    • /
    • 제11권5호
    • /
    • pp.469-484
    • /
    • 2001
  • A new beam system comprising two cantilever stems and an interspan composite beam has been developed and its design philosophy is described in this paper. The system provides the equivalent of a semi-continuous beam without the requirement to calculate the moment rotation capacity of the beam-to-column connection. The economy of braced frames using the system has been investigated and compared with simple, continuous or semi-rigid systems. It is shown that the costs of the proposed system are similar to the semi-rigid system and cheaper than both the simply supported and rigid beam systems. Two tests have been carried out on 6 meter span beams, which also incorporated an asymmetric flange steel section. The behaviour of the system is presented and the test results are compared with those obtained from the theory.

강판 콘크리트(SC) 기둥과 H형강 보의 용접 접합부에 대한 반복 이력 실험 (Cyclic Test of welding connections for Steel-Plate Concrete Column to H-shaped Steel Girders)

  • 박호영;강철규;최병정
    • 한국지진공학회논문집
    • /
    • 제18권1호
    • /
    • pp.63-71
    • /
    • 2014
  • This study presents an experimental study of the structural behavior for steel plate-concrete column-to-steel girder connections. Experiments were carried out to investigate the moment-rotation characteristics, failure behavior and ultimate moment capacity of these connections. The results of this experimental study involving three welded moment-resisting connections subjected to cyclic loading are presented. The specimens were fabricated at full scale to evaluate their hysteretic behavior. A description of the test specimens, the details of the joint, the test system and the testing methods are described. The test results showed that the structural behavior of these composite connections was influenced by the connection details.

A parametric investigation on the hysteretic behaviour of CFT column to steel beam connections

  • Esfandyary, R.;Razzaghi, M.S.;Eslami, A.
    • Structural Engineering and Mechanics
    • /
    • 제55권1호
    • /
    • pp.205-228
    • /
    • 2015
  • The results of a numerical investigation pertaining to the hysteretic behaviour of concrete filled steel tubular (CFT) column to I-beam connections are discussed in detail. Following the verification of the numerical results against the available experimental tests, the nonlinear finite element (FE) analysis was implemented to evaluate the effects of different parameters including the column axial load, beam lateral support, shape and arrangement of stiffeners, stiffness of T-stiffeners, and the number of shear stiffeners. Pursuing this objective, an external CFT column to beam connection, tested previously, was selected as the case-study. The lateral forces on the structure were simulated, albeit approximately, using an incremental cyclic loading reversal applied at the beam tip. The results were compared in terms of hysteretic load-displacement curves, stress distributions in connection, strength, rotation, and energy dissipation capacity. It was shown that external T-stiffeners combined with internal shear stiffeners play an important role in the hysteretic performance of CFT columns to I-beam connections.

더블 웨브앵글 반강접 CFT 기둥-보 접합부의 이력거동 (Hysteresis Behavior of Semirigid CFT Column-to-Beam Connections with a Double Web-Angle)

  • 이성주;김주우
    • 한국강구조학회 논문집
    • /
    • 제25권1호
    • /
    • pp.15-24
    • /
    • 2013
  • 본 논문은 반복하중을 받는 CFT 합성골조의 더블 웨브앵글 접합부의 휨모멘트 내력에 대해 체계적으로 수행된 유한요소 연구로부터 얻은 결과를 제시하고 있다. 합성 부분강접 CFT 접합부의 회전강성, 휨모멘트 내력 및 파괴모드를 연구하기 위하여 3차원 비선형 유한요소 해석이 수행되었다. 부가적인 다양한 구조적 거동은 앵글의 두께 및 고강도 강봉 게이지 거리로 더블 웨브앵글 접합부의 파라미터에 대한 영향을 설명하고 있다. 해석모델의 적합성은 정적 유한요소해석 결과로부터 얻은 모멘트-회전각 곡선을 Richard의 회귀분석을 통하여 비교 분석하였다.

T-스티프너 보강 CFT 기둥 - H형강보 실대형 접합부의 거동 (Behavior of CFT Column to H-Beam Full-Scale Connections with External T-Stiffeners)

  • 김영주;강창훈;신경재;오영석;문태섭
    • 한국강구조학회 논문집
    • /
    • 제13권6호
    • /
    • pp.715-723
    • /
    • 2001
  • 이 논문은 T-스티프너보강된 GFT기둥-H형강보 실대형 접합부의 거동을 나타낸다. 수직요소와 수평요소로 구성된 6개 실험체의 T-스트프너는 보의 전소성모멘트에 대한 강도비를 주요변수로 하여 제작되었다. 실험을 통하여 얻은 주요 내용은 강도, 강성과 소성회전능력이다. 모든 실험체는 대체로 안정된 이력거동을 나타내었으며, 특히 수평요소는 수직요소보다 강도와 강성에 더욱더 큰 영향을 준다. 보의 소성회전성능에 있어서, 조기에 파단한 TS-2를 제외한 실험체들의 평균 보소성회전각은 2.97% rad.이다.

  • PDF

상·하부 T-stub 접합부의 초기회전강성 평가 (Evaluation of the Initial Rotational Stiffness of a Double Split Tee Connection)

  • 김희동;양재근;이재윤;이형동
    • 한국강구조학회 논문집
    • /
    • 제26권2호
    • /
    • pp.133-142
    • /
    • 2014
  • 상 하부 T-stub 접합부는 보와 기둥의 강성비, T-stub의 기하학적 형상변화, 긴결재의 개수, 패널존 효과 등의 영향에 따라서 보통모멘트골조 및 특수모멘트골조에 적합한 거동특성을 나타내는 완전강도 부분강접 접합부(full strength partial restrained connection)이다. 이러한 상 하부 T-stub 접합부가 구조적으로 안전하게 거동하기 위해서는 충분한 강도, 강성, 연성능력을 나타내어야 한다. 이 연구는 T-stub의 기하학적 형상변화가 상 하부 T-stub 접합부의 모멘트-회전각 관계에 미치는 영향을 파악하고, 이에 따른 상 하부 T-stub 접합부의 초기회전강성을 평가하기 위해 진행하였다. 이를 위하여 T-stub의 기하학적 형상변수 ${\alpha}^{\prime}$값을 변화시킨 2개의 상 하부 T-stub 접합부 실험체를 제작하여 접합부 실험을 수행하였고, 3차원 비선형 유한요소해석도 수행하였다.

패널존의 강도비에 따른 기둥-보 접합부의 내진성능 평가 (Seismic Performance Evaluation of Beam-Column Connection for Panel Zone Strength)

  • 김성용;신창훈
    • 한국방재학회 논문집
    • /
    • 제7권1호통권24호
    • /
    • pp.11-20
    • /
    • 2007
  • 본 연구에서는 H형 기둥-보 접합부에서 스캘럽 주변의 파단을 피하기 위해 스캘럽을 생략하고 보와 기둥의 쉬어탭을 볼트로 체결한 후 보 플랜지의 양면에 커버 플레이트와 리브로 보강하는 방법을 제안하였다. 스캘럽을 생략함으로써 스캘럽에서의 응력집중의 빈도를 줄이고 용접부 주위에서의 취성파괴를 방지하여 건축물의 내진성능을 향상시키는데 본 연구의 목적을 둔다. 본 목적을 위해 총 4개의 실험체를 제작하고 반복 가력 실험을 실시하였다. 주요 실험변수는 패널존 강도비이고 실험체의 항복강도, 초기강성, 총소성회전에 대한각 부재의 기여도, 에너지 소산능력으로부터 제작된 실험체들이 특수모멘트골조 내진규정에 만족을 하는지와 실험에 사용된 변수에 대한 여러 영향을 밝히고자 하였다. 그 결과 모든 실험체는 층간변위 4%, 총소성회전 0.03rad.에 충분이 도달하여 1997 AISC의 내진규정에 따라 특수모멘트골조에 만족할 것이라 판단된다.

SRC기둥-H형단면과 U형단면으로 구성된 합성보 접합부의 반복가력실험 (Cyclic Loading Test on Connection of SRC Column-Composite Beam Consisting of H-Section and U-Section Members)

  • 김영주;배재훈;안태상;김진원;유홍식
    • 한국강구조학회 논문집
    • /
    • 제26권4호
    • /
    • pp.263-275
    • /
    • 2014
  • 본 연구에서는 SRC 기둥-H형단면과 U형단면으로 구성된 합성보 접합부에 관해서 반복가력실험을 실시하였다. 합성보에 관한 핵심요소는 H형단면과 U형단면 간 용접접합부의 구조적 성능이다. 이 두 부재 접합부의 성능을 향상시키기 위해서는 수직스티프너와 사다리꼴 스티프너가 필요하다. 접합부의 반복적인 성능을 평가하기 위해서 5개의 실대형 실험체를 계획하였으며, 실험변수는 H형단면의 크기($H-500{\times}200{\times}10{\times}16$, $H-600{\times}200{\times}11{\times}17$), 스티프너와 상부근의 유무 및 용접접근공(WAH)의 유무 등이다. 실험결과, H-500 시리즈 및 H-600 시리즈 보가 있는 실험체의 회전각은 각각 4%와 3%로 나타났으며, 이는 특수모멘트골조와 중간모멘트골조에 요구되는 값이다. 실험결과는 스티프너와 상부근이 있는 실험체의 변형능력이 그렇지 않은 실험체에 비해서 우수한 결과를 보였다. 끝으로, 실험체의 에너지소산능력과 변형도 분포를 요약하였다.