Browse > Article
http://dx.doi.org/10.7781/kjoss.2014.26.4.263

Cyclic Loading Test on Connection of SRC Column-Composite Beam Consisting of H-Section and U-Section Members  

Kim, Young Ju (Construction Engineering Center, DRB Holding Co., Ltd.)
Bae, Jae Hoon (Construction Engineering Center, DRB Holding Co., Ltd.)
Ahn, Tae Sang (Construction Engineering Center, DRB Holding Co., Ltd.)
Kim, Jin Won (Building Structure & Material Research Dept., POSCO Steel Solution Center)
Ryu, Hong Sik (Building Structure & Material Research Dept., POSCO Steel Solution Center)
Publication Information
Journal of Korean Society of Steel Construction / v.26, no.4, 2014 , pp. 263-275 More about this Journal
Abstract
In this study, connection of steel reinforced concrete(SRC) column and composite beam which consists of H-section and U-section members were tested under cyclic loading. An essential point of the composite beam is the structural performance of welded joint between the H-section and the U-section members. To improve the structural performance of joint of two beam members, vertical stiffeners, trapezoidal stiffeners, and top bars were used. Five full-scaled specimens were designed to study the effect of a number of parameters on cyclic performance of connections such as H-section beam size($H-500{\times}200{\times}10{\times}16$, $H-600{\times}200{\times}11{\times}17$), the presence of stiffeners and top bars, and the presence of no weld access hole(WAH) method. Based on the test results, deformation capacity of the specimens with H-500 series beam and H-600 series beam were 4% and 3% rotation angle, which is the requirement for the Special Moment Frame and Intermediate Moment Frame(IMF), respectively. Test result showed that deformation capacity of connection with stiffeners and top bars is greater than that of connection without stiffeners and top bars. Finally, energy dissipation capacity and strain profile of specimens were summarized.
Keywords
Composite beam; H-section; U-section; Beam-Column connection; Cyclic loading test; Deformation capacity;
Citations & Related Records
Times Cited By KSCI : 4  (Citation Analysis)
연도 인용수 순위
1 CEN (2004) prEN 1994-1-1:2004: Final Version of Editorial Group; Eurocode 4, Design of composite steel and concrete structures Part 1.1: General rules and rules for buildings, Comite Europeen de Normalisation (CEN), Brussels, Belgium.
2 Johnson, R.P. (1994) Composite Structures of Steel and Concrete; Volume I. Beams, Slabs, Columns, and Frames for Buildings, Blackwell Scientific Publications, Osney Mead, Oxford.
3 김영주, 배재훈, 안태상, 장동운(2014) 합성보에 적용된 앵글 전단연결재의 Push-out 실험, 한국강구조학회논문집, 한국강구조학회, 제26권, 제3호, pp.155-167. (Kim, Y.J., Bae, J.H., Ahn, T.S., and Jang, D.W. (2014) Push-out Test on Welded Angle Shear Connectors used in Composite Beams, Journal of Korean Society of Steel Construction, KSSC, Vol.26, No.1, pp.155-167 (in Korean)).   과학기술학회마을   DOI   ScienceOn
4 대한건축학회(2009) 건축구조설계기준 및 해설(KBC2009), 기문당. (AIK (2009) Korean Building Code and Commentary-Structural, Architectural Institute of Korea (in Korean))
5 ANSI/AISC 341-10 (2010) Seismic Provisions for Structural Steel Buildings, American Institute of Steel Construction, Chicago.
6 Kim, Y.J., Oh, S.H., and Moon, T.S. (2004) Seismic Behavior and Retrofit of Steel Moment Connections Considering Slab Effects, Engineering Structures, Vol.26, No.13, pp.1993-2005.   DOI   ScienceOn
7 한국강구조학회(2009) 건축강구조 표준접합상세지침, 구미서관. (KSSC (2009) Standard Connection Detail of Steel Structures for Buildings, Korean Society of Steel Construction, Goomi Books, Korea (in Korean)).
8 김성배, 김상섭, 유덕수(2013) 신형상 U형 하이브리드 합성보와 기둥 접합부의 내진성능에 관한 연구, 한국강구조학회논문집, 한국강구조학회, 제25권, 제1호, pp.47-59. (Kim, S.B., Kim, S.S., and Ryu, D.S. (2013) Study on the Cyclic Seismic Testing of U-shape Hybrid Composite Beam-to-Composite Column Connections, Journal of Korean Society of Steel Construction, KSSC, Vol.25, No.1, pp.47-59 (in Korean)).   과학기술학회마을   DOI   ScienceOn
9 양일승, 오영호, 이만재(2012) 드라이빙핀전용 전단연결재를 이용한 합성보의 탄소성 거동, 한국강구조학회논문집, 한국강구조학회, 제24권, 제1호, pp.73-80. (Yang, I.S., Oh, Y.H., and Lee, M.J. (2012) Elasto-Plastic Behaviors of Composite Beam using Shear Connectors installed in Driving Pins, Journal of Korean Society of Steel Construction, KSSC, Vol.24, No.1, pp.73-80 (in Korean)).   과학기술학회마을   DOI   ScienceOn
10 황현종, 엄태성, 박홍근, 이창남, 김형섭(2013) TSC 합성보 - PSRC 합성기둥 접합부에 대한 주기하중 실험, 한국강구조학회논문집, 한국강구조학회, 제25권, 제6호, pp.601-612. (Hwang, H.J., Eom, T.S., Park, H.G., Lee, C.N., and Kim, H.S. (2003) Cyclic Loading Test for TSC Beam - PSRC Column Connections, Journal of Korean Society of Steel Construction, KSSC, Vol.25, No.6, pp.601-612 (in Korean)).   과학기술학회마을   DOI
11 Ciutina, A.L. and Stratan, A. (2008) Cyclic Performances of Shear Connectors, Composite Construction in Steel and Concrete VI, ASCE, SEI, Devil Thumb Ranch, Colorado, USA.
12 FEMA (2000) State of the Art Report on Connection Performance, FEMA355D, Federal Emergency Management Agency, Washington, DC.