• 제목/요약/키워드: Connection condition

검색결과 694건 처리시간 0.034초

LICHNEROWICZ CONNECTIONS IN ALMOST COMPLEX FINSLER MANIFOLDS

  • LEE, NANY;WON, DAE-YEON
    • 대한수학회보
    • /
    • 제42권2호
    • /
    • pp.405-413
    • /
    • 2005
  • We consider the connections $\nabla$ on the Rizza manifold (M, J, L) satisfying ${\nabla}G=0\;and\;{\nabla}J=0$. Among them, we derive a Lichnerowicz connection from the Cart an connection and characterize it in terms of torsion. Generalizing Kahler condition in Hermitian geometry, we define a Kahler condition for Rizza manifolds. For such manifolds, we show that the Cartan connection and the Lichnerowicz connection coincide and that the almost complex structure J is integrable.

THE EXISTENCE AND UNIQUENESS OF E(*κ)-CONNECTION IN n-*g-UFT

  • Lee, Jong Woo
    • Korean Journal of Mathematics
    • /
    • 제13권1호
    • /
    • pp.1-11
    • /
    • 2005
  • The purpose of the present paper is to introduce a new concept of the E($^*{\kappa}$)-connection ${\Gamma}^{\nu}_{{\lambda}{\mu}}$, which is both Einstein and ($^*{\kappa}$)-connection, and to obtain a necessary and sufficient condition for the existence of the unique E($^*{\kappa}$)-connection in $n-^*g$-UFT. Next, under this condition, we shall obtain a surveyable tensorial representation of the unique E($^*{\kappa}$)-connection in $n-^*g$-UFT.

  • PDF

YANG-MILLS CONNECTIONS ON CLOSED LIE GROUPS

  • Pyo, Yong-Soo;Shin, Young-Lim;Park, Joon-Sik
    • 호남수학학술지
    • /
    • 제32권4호
    • /
    • pp.651-661
    • /
    • 2010
  • In this paper, we obtain a necessary and sufficient condition for a left invariant connection in the tangent bundle over a closed Lie group with a left invariant metric to be a Yang-Mills connection. Moreover, we have a necessary and sufficient condition for a left invariant connection with a torsion-free Weyl structure in the tangent bundle over SU(2) with a left invariant Riemannian metric g to be a Yang-Mills connection.

e-마켓플레이스의 연계유형에 관한 연구 (A Study on the Connection Type in e-Marketplace)

  • 최형림;박남규;황성원;이창섭;박민선
    • 한국전자거래학회:학술대회논문집
    • /
    • 한국전자거래학회 2003년도 종합학술대회 논문집
    • /
    • pp.172-177
    • /
    • 2003
  • As the electronic commerce in industry is spreading rapidly, the invitation and investment of e-marketplace is becoming a necessary condition for the industry's competition power insurance and existence. The successful conditions of e-marketplace are many supplier, many buyer, a globalism through the association and cooperation of a foreign marketplace. For that, the connection action inter industries and marketplaces is very necessary, In a condition of the study about the systematic connection type's classification is not exist, the paper aims at classifying the connection type that influences of e-marketplace playing a leading role. So, the connection type classifies into the list offering type, the trade mediation type, the supplementation type, the collaboration type, the information linking type. When we go ahead with a e-marketplace's plan, the paper will guide how to approach and analyze it.

  • PDF

가구형태와 사회적 관계의 객관적·주관적 측면이 우울에 미치는 영향 : 1인 가구와 다인 가구의 비교를 중심으로 (The impact of household types and social relationships on depression : based on the comparison between single-person households and multi-person households)

  • 최유정;이명진;최샛별
    • 한국가족관계학회지
    • /
    • 제21권2호
    • /
    • pp.25-51
    • /
    • 2016
  • Objectives: This research started with the attempt to comprehend the relationship between household types and psychological stability by linking single-person households to the emotional index "depression." Method: For this purpose, we first compare to see if there is a difference in socio-demographic variables, social relationships, the degree of depression between single households and multi-person households, and to comprehend the relative influence that household types have on depression by taking other factors under consideration. Results: Then based on the results, we compare and analyze the factors that affect the degree of depression on single-person households and multi-person households, respectively. To summarize the results, first of all, residents in single-person households are somewhat older but show lower level of income, education, and health condition compared to peers inmulti-person households. They also had a consistently high level not only in the frequency of contact and emotional connection with families, relatives, and friends, but also in the degree of depression when compared to multi-person households. Secondly, for depression, considering the various factors targeting all the households, the following had a strong influence in the order of "health condition compared to peers," "emotional connection with family," "household types," "emotional connection with colleagues," "frequency of contact with neighbors," "gender," and "age."The degree of depression increases in the following conditions: if the health condition is worse, lower emotional connection with family, single-person household, lower emotional connection with colleagues, lower the frequency of contact with neighbors, female, and older the age. Thirdly, comparing the factors that affect depression by dividing single-person households and multi-person households, "health condition compared to peers" and "emotional connection with family" had the largest effect in common, respectively. In cases of living alone, regardless of other factors, the degree of depression increases with "health condition compared to peers" and "emotional connection with family." Conclusions: On the contrary, in multi-person households, "health condition compared to peers," "emotional connection with family," "emotional connection with colleagues," "income," and "gender" are important.

임플랜트-지대주의 연결방법에 따른 임플랜트 보철의 유한요소 응력분석 (FINITE ELEMENT STRESS ANALYSIS OF IMPLANT PROSTHESIS ACCORDING TO CONNECTION TYPES OF IMPLANT-ABUTMENT)

  • 허진경;계기성;정재헌
    • 대한치과보철학회지
    • /
    • 제43권4호
    • /
    • pp.544-561
    • /
    • 2005
  • Purpose : This study was to assess the loading distributing characteristics of implant systems with internal connection or external connection under vertical and inclined loading using finite element analysis. Materials and methods : Two finite element models were designed according to type of internal connection or external connection The crown for mandibular first molar was made using cemented abutment. Each three-dimensional finite element model was created with the physical properties of the implant and surrounding bone This study simulated loads of 200N at the central fossa in a vertical direction (loading condition A), 200N at the centric cusp tip in a 15$^{\circ}$ inward inclined direction (loading condition B), or 200N at the centric cusp tip in a 30$^{\circ}$ outward inclined direction (loading condition C) respectively. Von Mises stresses were recorded and compared in the supporting bone, fixture, abutment and abutment screw. Results : 1. In comparison with the whole stress or the model 1 and model 2, the stress pattern was shown through th contact of the abutment and the implant fixture in the model 1, while the stress pattern was shown through the abutment screw mainly in the model 2. 2. Without regard to the loading condition, greater stress was taken at the cortical bone, and lower stress was taken at the cancellous bone. The stress taken at the cortical bone was greater at the model 1 than at the model 2, but the stress taken at the cortical bone was much less than the stress taken at the abutment, the implant fixture, and the abutment screw in case of both model 1 and model 2. 3. Without regard to the loading condition, the stress pattern of the abutment was greater at the model 1 than at the model 2. 4. In comparison with the stress distribution of model 1 and model 2, the maximum stress was taken at the abutment in the model 1. while the maximum stress was taken at the abutment screw in the model 2. 5. The magnitude of the maximum stress taken at the supporting bone, the implant fixture, the abutment, and the abutment screw was greater in the order of loading condition A, B and C. Conclusion : The stress distribution pattern of the internal connection system was mostly distributed widely to the lower part along the inner surface of the implant fixture contacting the abutment core through its contact portion because of the intimate contact of the abutment and the implant fixture and so the less stress was taken at the abutment screw, while the abutment screw can be the weakest portion clinically because the greater stress was taken at the abutment screw in case of the external connection system, and therefore the further clinical study about this problem is needed.

YAMABE SOLITONS ON KENMOTSU MANIFOLDS

  • Hui, Shyamal Kumar;Mandal, Yadab Chandra
    • 대한수학회논문집
    • /
    • 제34권1호
    • /
    • pp.321-331
    • /
    • 2019
  • The present paper deals with a study of infinitesimal CL-transformations on Kenmotsu manifolds, whose metric is Yamabe soliton and obtained sufficient conditions for such solitons to be expanding, steady and shrinking. Among others, we find a necessary and sufficient condition of a Yamabe soliton on Kenmotsu manifold with respect to CL-connection to be Yamabe soliton on Kenmotsu manifold with respect to Levi-Civita connection. We found the necessary and sufficient condition for the Yamabe soliton structure to be invariant under Schouten-Van Kampen connection. Finally, we constructed an example of steady Yamabe soliton on 3-dimensional Kenmotsu manifolds with respect to Schouten-Van Kampen connection.

임플란트와 지대주간 내측 연결을 갖는 임플란트 보철의 유한요소 응력분석 (FINITE ELEMENT STRESS ANALYSIS OF IMPLANT PROSTHESIS WITH INTERNAL CONNECTION BETWEEN THE IMPLANT AND THE ABUTMENT)

  • 안종관;계기성;정재헌
    • 대한치과보철학회지
    • /
    • 제42권4호
    • /
    • pp.356-372
    • /
    • 2004
  • Statement of problom: In the internal connection system the loading transfer mechanism within the inner surface of the implant and also the stress distribution occuring to the mandible can be changed according to the abutment form. Therefore it is thought to be imperative to study the difference of the stress distribution occuring at the mandible according to the abutment form. Purpose: The purpose of this study was to assess the loading distributing characteristics of 3 implant systems with internal connection under vertical and inclined loading using finite element analysis. Material and method: Three finite element models were designed according to the type of internal connection of ITI(model 1), Friadent(model 2), and Bicon(model 3) respectively. This study simulated loads of 200N in a vertical direction (A), a $15^{\circ}$ inward inclined direction (B), and a $30^{\circ}$ outward inclined direction (C). Result: The following results have been made based on this numeric simulations. 1. The greatest stress showed in the loading condition C of the inclined load with outside point from the centric cusp tip. 2. Without regard to the loading condition, the magnitudes of the stresses taken at the supporting bone, the implant fixture, and the abutment were greater in the order of model 2, model 1, and model 3. 3. Without regard to the loading condition, greater stress was concentrated at the cortical bone contacting the upper part of the implant fixture, and lower stress was taken at the cancellous bone. 4. The stress of the implant fixture was usually widely distributed along the inner surface of the implant fixture contacting the abutment post. 5. The stress distribution pattern of the abutment showed that the great stress was usually concentrated at the neck of the abutment and the abutment post, and the stress was also distributed toward the lower part of the abutment post in case of the loading condition B, C of the inclined load. 6. In case of the loading condition B, C of the inclined load, the maximum von Misess stress at the whole was taken at the implant fixture both in the model 1 and model 2, and at the abutment in the model 3. 7. The stress was inclined to be distributed from abutment post to fixture in case of the internal connection system. Conclusion: The internal connection system of the implant and the abutment connection methods, the stress-induced pattern at the supporting bone, the implant fixture, and the abutment according to the abutment connection form had differenence among them, and the stress distribution pattern usually had a widely distributed tendency along the inner surface of the implant fixture contacting the a butment post.

Splinted or Non-splinted: 다수의 인접한 치아 결손부 수복을 위한 임플란트 보철 (Splinted and non-splinted implant-supported restorations : prosthetic considerations for restoring multiple adjacent teeth)

  • 윤형인
    • 대한치과의사협회지
    • /
    • 제54권3호
    • /
    • pp.198-205
    • /
    • 2016
  • The purpose of this paper was to investigate the significance of splinted and non-splinted implant-supported restorations with an internal connection for multiple consecutively missing teeth. Upon examination of the effects of fixture-abutment connection, the distribution of occlusal load was favorable in splinted implant-prosthesis with an external connection, but effect of strain distribution was not significant in splinted implant-prosthesis with an internal connection. In splinted implant-prostheses for short implants, strain distribution was not affected by the method of retention. For cement-retained prostheses, the effect of strain distribution due to splinting was not significant. In clinical studies, non-splinted prostheses with an internal connection for multiple consecutively missing teeth showed high survival rate, mild marginal bone loss, and stable periodontal condition. However, failure to achieve optimal proximal contact between single-unit prostheses may lead to food impaction, and veneer fracture may be inevitable when the framework provides inadequate support in the proximal region. In conclusion, splinted implant-prosthesis is not an indication in all cases, and clinical consideration of its use should be based on the patient's oral condition, such as location and number of implants, formation of proximal contact, canine guidance, existence of parafunctional habit, and oral hygiene, when multiple consecutively missing teeth are replaced by internal connection type implant.

  • PDF

EINSTEIN'S CONNECTION IN 5-DIMENSIONAL ES-MANIFOLD

  • Hwang, In Ho
    • Korean Journal of Mathematics
    • /
    • 제25권1호
    • /
    • pp.127-135
    • /
    • 2017
  • The manifold $^*g-ESX_n$ is a generalized n-dimensional Riemannian manifold on which the differential geometric structure is imposed by the unified field tensor $^*g^{{\lambda}{\nu}}$ through the ES-connection which is both Einstein and semi-symmetric. The purpose of the present paper is to prove a necessary and sufficient condition for a unique Einstein's connection to exist in 5-dimensional $^*g-ESX_5$ and to display a surveyable tnesorial representation of 5-dimensional Einstein's connection in terms of the unified field tensor, employing the powerful recurrence relations in the first class.