• Title/Summary/Keyword: Cone Beam CT

Search Result 238, Processing Time 0.026 seconds

The reliability of the cephalogram generated from cone-beam CT (Cone-beam CT로부터 제작된 측모 두부계측방사선사진의 정확도 평가)

  • Kang, Ji-Young;Kim, Kwang-Won;Lim, Sung-Hoon
    • The korean journal of orthodontics
    • /
    • v.37 no.6
    • /
    • pp.391-399
    • /
    • 2007
  • Three-dimensional approaches for the diagnosis and analysis of the dentofacial area are becoming more popular in accordance with the development of cone-beam CT (CBCT). The purposes of this study were to evaluate the reliability of cephalometric measurements of lateral cephalograms generated from a CBCT image by making comparisons with the traditional digital lateral cephalogram, and to evaluate the possibility of the clinical application of CBCT generated cephalogram images. Methods: Twenty patients whose external auditory meatus could be identified in the CBCT image were selected, and both CBCT and digital cephalograms were taken. Differences between the measurements of both cephalograms were tested by paired t-test. Results: Among the 22 measurements used, only U1-FH, Mx6 to PTV, and maxillomandibular difference showed statistically significant differences between the CBCT generated cephalogram and the digital cephalogram. Conclusions: The results suggest that the CBCT generated cephalogram can be used for some cephalometric measurements not requiring porion, PTV, condylion as a landmark (SNA, SNB, U1 to SN, IMPA, interincisal angle, etc.).

A Review of Organ Dose Calculation Tools for Patients Undergoing Computed Tomography Scans

  • Lee, Choonsik
    • Journal of Radiation Protection and Research
    • /
    • v.46 no.4
    • /
    • pp.151-159
    • /
    • 2021
  • Background: Computed tomography (CT) is one of the crucial diagnostic tools in modern medicine. However, careful monitoring of radiation dose for CT patients is essential since the procedure involves ionizing radiation, a known carcinogen. Materials and Methods: The most desirable CT dose descriptor for risk analysis is the organ absorbed dose. A variety of CT organ dose calculators currently available were reviewed in this article. Results and Discussion: Key common elements included in CT dose calculators were discussed and compared, such as computational human phantoms, CT scanner models, organ dose database, effective dose calculation methods, tube current modulation modeling, and user interface platforms. Conclusion: It is envisioned that more research needs to be conducted to more accurately map CT coverage on computational human phantoms, to automatically segment organs and tissues for patient-specific dose calculations, and to accurately estimate radiation dose in the cone beam computed tomography process during image-guided radiation therapy.

Characteristics of a new cone beam computed tomography

  • Park, Chang-Seo;Kim, Kee-Deog;Park, Hyok;Jeong, Ho-Gul;Lee, Sang-Chul
    • Imaging Science in Dentistry
    • /
    • v.37 no.4
    • /
    • pp.205-209
    • /
    • 2007
  • Purpose: To determine the physical properties of a newly developed cone beam computed tomography (CBCT). Materials and Methods: We measured and compared the imaging properties for the indirect-type flat panel detector (FPD) of a new CBCT and the single detector array (SDA) of conventional helical CT (CHCT). Results: First, the modulation transfer function (MTF) of the CBCT were superior to those of the CHCT. Second, the noise power spectrum (NPS) of the CBCT were worse than those of the CHCT. Third, detective quantum efficiency (DQE) of the indirect-type CBCT were worse than those of the CHCT at lower spatial frequencies, but were better at higher spatial frequencies. Although the comparison of contrast-to-noise ratio (CNR) was estimated in the limited range of tube current, CNR of CBCT were worse than those of CHCT. Conclusion: This study shows that the indirect-type FPD system may be useful as a CBCT detector because of high resolution.

  • PDF

Comparison of panoramic radiography with cone beam CT in predicting the relationship of the mandibular third molar roots to the alveolar canal

  • Shahidi, Shoaleh;Zamiri, Barbod;Bronoosh, Pegah
    • Imaging Science in Dentistry
    • /
    • v.43 no.2
    • /
    • pp.105-109
    • /
    • 2013
  • Purpose: Preoperative radiographic assessment of the mandibular third molars is essential to prevent inferior alveolar nerve damage during extraction. The purpose of this study was to assess the reliability of panoramic signs of association between the roots of teeth and the canal, and to compare the panoramic signs with cone beam computed tomography (CBCT) findings. Materials and Methods: CBCT images of 132 impacted mandibular third molars were evaluated to determine the association of the root to the canal. The CBCT findings were compared with the corresponding panoramic images. Logistic regression analysis was used to define the diagnostic criteria of the panoramic images. Results: Among the panoramic signs, loss of the cortical line was the most frequent radiographic sign predicting association (sensitivity: 79.31). Contact of the tooth with the canal was observed in all cases in which the loss of cortical line of the canal or darkening of the roots was found on the panoramic radiographs. Conclusion: Darkening of the roots and loss of the cortical line on panoramic radiographs might be highly suggestive of the risk of nerve injury.

Anomalies of the clivus of interest in dental practice: A systematic review

  • McCartney, Troy E.;Mupparapu, Mel
    • Imaging Science in Dentistry
    • /
    • v.51 no.4
    • /
    • pp.351-361
    • /
    • 2021
  • Purpose: The clivus is a region in the anterior section of the occipital bone that is commonly imaged on large-volume cone-beam computed tomography (CBCT). There have been several reports of incidental clivus variations and certain pathological entities that have been attributed to the variations. This study aimed to evaluate the effects of these variations within the scope of dentistry. Materials and Methods: Medical databases (PubMed, Scopus, and Web of Science) were searched using a controlled vocabulary (clival anomalies, cone-beam CT, canalis basilaris medianus, fossa navicularis magna, clival variation). The search was limited to English language, humans, and studies published in the last 25 years. The articles were exported into RefWorks® and duplicates were removed. The remaining articles were screened and reviewed for supporting information on variations of the clivus on CBCT imaging. Results: Canalis basilaris medianus and fossa navicularis magna were the most common anomalies noted. Many of these variations were asymptomatic, with most patients unaware of the anomaly. In certain cases, associated pathologies ranged from developmental (Tornwaldt cyst), to acquired (recurrent meningitis). While no distinct pathognomonic aspects were noted, there were unique patterns of radiographic diagnosis and treatment modalities. Most patients had a normal course of follow-up. Conclusion: Interpretation of CBCT volumes is a skill every dentist must possess. When reviewing large-volume CBCT scans, the clinician should be able to distinguish pathology from normal anatomic variations within the skull base. The majority of clivus variations are asymptomatic and will remain undetected unless incidentally noted on radiographic examinations.

Validity of Horizontal Reference Planes on Cone-Beam Computed Tomography Generated Postero-Anterior Cephalogram (Cone-beam CT영상으로부터 얻어진 정모두부방사선사진에서 수평기준선의 설정)

  • Kang, Hee-Jea;Kim, Jong-Ryoul;Kim, Yong-Il
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.33 no.4
    • /
    • pp.346-351
    • /
    • 2011
  • Purpose: The purpose of this study was to measure the angular differences between the horizontal reference planes on the CBCT generated PA cephalogram and the modified interpupillary plane, which was usually used in the clinical examination, and to evaluate the validity of the horizontal reference planes. Methods: The CBCT generated PA cephalogram was used to measure the angles between the FH, Lo and IP planes. The subjects consisted of 42 patients with facial asymmetry (males: 21, females: 21, mean-age: 21.6 years). The control groups were also assessed (males: 10, females: 10, mean-age: 23.8 years). The distance of the interpupil was measured on the soft-tissue volume rendered image. The angular differences were statistically analyzed using the $Mann-Whitney$ $U$ $test$ for inter-group comparisons and the $Friedman$ $test$ for intra-group comparisions. Results: The angle between the FH plane and IP plane (the angle of the FH-IP line) showed a statistically significant difference between the two groups ($p$ <0.05). There was no statistical differences between each angle (angle of the FH-IP line, angle of the FH-Lo line, angle of the Lo-IP line) on the intra-group comparision ($p$ >0.05). Conclusion: The angle between the Lo line and IP line (angle of the Lo-IP line) showed no statistically significant difference in both the control and asymmetry groups. Therefore, the Lo line could be used as a horizontal reference plane in CBCT generated PA cephalograms.

An anatomical study on the mandibular medial surface by CBCT analysis for safer implant placement (안전한 임플란트 식립을 위한 하악골 내측면의 CBCT를 이용한 해부학적 연구)

  • Lee, Jung-Kyo;Kim, Yeo-Gab
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.37 no.1
    • /
    • pp.43-48
    • /
    • 2011
  • Introduction: This study examined the anatomical morphology of the medial surface of the posterior mandible using 3-dimensional cone-beam computed tomography (CT) images to reduce the number of complications related to dental implant placement. Materials and Methods: Fifty patients were enrolled in this study with an average age (${\pm}$standard deviation) of 44.28 (${\pm}13.05$). On the coronal views cone-beam CT of the first molars, the distance between the top of the canal and alveolar crest vertical distance (VD), the distance between the upper-most point of the canal and the point perpendicular to the lingual cortical margin of the mandible lingual distance (LD), the location of the starting point of VD for reducing from the vertical reference line (VD point), and the inclination of the mandibular medial surface (lingual inclination) were measured, and a statistical evaluation was performed using SPSS for Windows version 15.0. Results: The mean VD0 was $16.91{\pm}2.47\;mm$ and VDx decreased with increasing x value. The mean LD was $5.27{\pm}1.36\;mm$. The VD began to decrease at the mean location of $6.12{\pm}0.96\;mm$ from the vertical reference line. The mean lingual inclination was $1.52{\pm}0.72^{\circ}$. Conclusion: These results will assist in the accurate placement of dental implants and the reduction of complications, particularly in the case of preoperative implant planning using only 2-dimensional imaging methods. (ex. panoramic radiography)

Conversion coefficients for the estimation of effective dose in cone-beam CT

  • Kim, Dong-Soo;Rashsuren, Oyuntugs;Kim, Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • v.44 no.1
    • /
    • pp.21-29
    • /
    • 2014
  • Purpose: To determine the conversion coefficients (CCs) from the dose-area product (DAP) value to effective dose in cone-beam CT. Materials and Methods: A CBCT scanner with four fields of view (FOV) was used. Using two exposure settings of the adult standard and low dose exposure, DAP values were measured with a DAP meter in C mode ($200mm{\times}179mm$), P mode ($154mm{\times}154mm$), I mode ($102mm{\times}102mm$), and D mode ($51mm{\times}51mm$). The effective doses were also investigated at each mode using an adult male head and neck phantom and thermoluminescent chips. Linear regressive analysis of the DAP and effective dose values was used to calculate the CCs for each CBCT examination. Results: For the C mode, the P mode at the maxilla, and the P mode at the mandible, the CCs were 0.049 ${\mu}Sv/mGycm^2$, 0.067 ${\mu}Sv/mGycm^2$, and 0.064 ${\mu}Sv/mGycm^2$, respectively. For the I mode, the CCs at the maxilla and mandible were 0.076 ${\mu}Sv/mGycm^2$ and 0.095 ${\mu}Sv/mGycm^2$, respectively. For the D mode at the maxillary incisors, molars, and mandibular molars, the CCs were 0.038 ${\mu}Sv/mGycm^2$, 0.041 ${\mu}Sv/mGycm^2$, and 0.146 ${\mu}Sv/mGycm^2$, respectively. Conclusion: The CCs in one CBCT device with fixed 80 kV ranged from 0.038 ${\mu}Sv/mGycm^2$ to 0.146 ${\mu}Sv/mGycm^2$ according to the imaging modes and irradiated region and were highest for the D mode at the mandibular molar.

Surgical stent for dental implant using cone beam CT images (콘빔형 전산화단층영상을 이용한 치과임플란트 식립유도장치 개발)

  • Choi, Hyung-Soo;Kim, Gyu-Tae;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • v.40 no.4
    • /
    • pp.171-178
    • /
    • 2010
  • Purpose : The purpose of this study is to develop a surgical stent for dental implant procedure that can be easily applied and affordable by using cone beam computerized tomography (CBCT). Materials and Methods : Aluminum, Teflon-PFA (perfluoroalkoxy), and acetal (polyoxymethylene plastic) were selected as materials for the surgical stent. Among these three materials, the appropriate material was chosen using the CBCT images. The surgical stent, which could be easily placed into an oral cavity, was designed with chosen material. CBCT images of the new surgical stent on mandible were obtained using Alphard-3030 dental CT system (Asahi Roentgen Co., Ltd., Kyoto, Japan). The point of insertion was prescribed on the surgical stent with the multiplanar reconstruction software of OnDemand3D (CyberMed Inc., Seoul, Korea). Guide holes were made at the point of insertion on the surgical stent using newly designed guide jig. CBCT scans was taken for the second time to verify the accuracy of the newly designed surgical stent. Results : Teflon-PFA showed radiologically excellent image characteristics for the surgical stent. High accuracy and reproducibility of implantation were confirmed with the surgical stent. Conclusion : The newly designed surgical stent can lead to the accurate implantation and achieve the clinically predictable result.

Radiographic evaluation of dentigerous cyst with cone beam CT (콘빔형전산화단층장치를 이용한 함치성낭의 방사선학적 연구)

  • Park, Yong-Chan;Lee, Wan;Lee, Byung-Do
    • Imaging Science in Dentistry
    • /
    • v.40 no.3
    • /
    • pp.115-121
    • /
    • 2010
  • Purpose : The purpose of this study was to accurately analyze the radiographic characteristics of dentigerous cyst (DC) with multiplanar images of cone beam computed tomography (CBCT). Materials and Methods : Thirty eight radiographically and histopathologically proven cases of DCs were analyzed with panoramic radiograph and CBCT, retrospectively. The radiographic CT pattern, symmetry of radiolucency around the unerupted tooth crown, ratio of long length to short length, degree of cortical bone alternation, effects on adjacent tooth, and cyst size were analyzed. Relative frequencies of these radiographic features were evaluated. In order to compare the CBCT features of DC with those of odontogenic keratocyst (OKC), 9 cases of OKCs were analyzed with the same method radiographically. Results : DCs consisted of thirty unilocular cases (79.0%), seven lobulated cases (18.4%) and one multilocular case (2.6%). Eight were asymmetric (21.0%) and thirty were symmetric (79.0%). Maxillary DC showed rounder shape than mandibular DC (L/S ratio; maxilla 1.32, mandible 1.67). Alternations of lingual cortical bone (14 cases, 48.2%) were more frequent than those of buccal side (7 cases, 24.1%). CBCT images of DC showed definite root resorption and bucco-lingual tooth displacement. These findings were hardly observed on panoramic radiographs of DCs. Comparison of CBCT features of DC with those of OKC showed several different features. Conclusions : CBCT images of DC showed various characteristic radiographic features. Therefore, CBCT can be helpful for the diagnosis of DC radiographically.