• 제목/요약/키워드: Condensation in Summer

검색결과 38건 처리시간 0.022초

공동주택의 하절기 결로 방지에 대한 연구 (A Study on Anti-Condensation of the Apartment Building in Summer)

  • 김승범;서희창;김주형;김재준
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 추계 학술논문 발표대회
    • /
    • pp.17-18
    • /
    • 2012
  • Moisture condensation leading to defects that occur repeatedly in the winter, and recognize the same method, the problem of the other buildings in the same area again and again, a vicious cycle that occurs due to the temporary lack of systematic research and processing way of coping has been recurring. In this study, as warming progresses, more inside the air-conditioned summer season due to an increase in the ambient temperature of the condensation phenomenon to happen about summer wall condensation phenomena are expected to analyze the case of a building to prevent condensation and for insulation designs are proposed.

  • PDF

강제환기를 이용한 하절기 군 저장시설의 표면결로 방지에 관한 연구 (Forced Ventilation Method for Preventing Surface Condensation of Magazine of Igloo type in Summer)

  • 박선효;윤성도;손장열
    • KIEAE Journal
    • /
    • 제10권2호
    • /
    • pp.57-62
    • /
    • 2010
  • In case of earth-covered storage, the condensation occurs on surface of wall and stores in summer with high humidity because of low temperature of constructional mass. Therefore, the preventive plans should be considered to protect stores from the damage by corrosion in earth-covered storages. This study aims to suggest the methods of forced ventilation by the air, to solve the problems of construction's surface condensation at the Magazine of igloo type which is similar to earth-covered storages. A fan was installed at the air outlet for exhaust gas to conduct forced ventilation. The surface and indoor temperature were measured, and then the influence of those on condensation was analyzed. The results of this research are follows; 1) Forced ventilation by a fan affects the rise in surface temperature of walls and stores. 2) The condensation on surface of walls and stores was reduced after operating a fan.

응축폐열을 이용한 건조 및 온수장치에 관한 연구 (A Study on The Drying and Hot Water System Using Condensation Waste Heat)

  • 박노현;고하영;정진웅;강통삼
    • 대한설비공학회지:설비저널
    • /
    • 제15권4호
    • /
    • pp.362-371
    • /
    • 1986
  • In the normal Refrigeration process, the condensation heat of refrigerant s not been used because of its low-temperature waste heat. To recover the condensation waste heat of R-12 refrigerator, a drying and hot water system was designed and experimented. The results obtained were summarized as follows: 1. As the temperature a temosphere was increased, the temperature of discharge gas of compressor was increased. And the temperature was $80-84^{\circ}C$ for air condensing type and was $68-71^{\circ}C$ for water condensing type during summer. 2. The condensation waste heat could be obtained up to $50-55^{\circ}C$ of drying heat-source and Hot water in summer. In this case, recovered rate was about $73\%$. And the more temperature of drying Heat-source and Hot water were increased, the more a recovered rate were decreased. 3. When comparing drying characteristics of Agro-products in dryer of waste heat utilization and Hot air, there was no quality difference in products. But drying time of the former was 3 Hours longer than the latter. 4. The condensation waste heat of compressor could be applied into the drying of marine products, the predrying of agro-products and making hot water. And showed high possibility of the waste heat using in low-temperature storage.

  • PDF

화순 운주사 석조불감의 보존환경 및 미기상 분석 (Analysis of Microclimate and Conservation Environment of the Stone Buddha and Shrine in Unjusa Temple, Hwasun, Korea)

  • 박성미;이찬희;이명성;김사덕
    • 자원환경지질
    • /
    • 제42권1호
    • /
    • pp.73-84
    • /
    • 2009
  • 화순 운주사 석조불감(보물 제797호)은 고려시대 양식을 갖추고 있는 석조문화재로서 우리나라에서 유래를 찾아볼 수 없는 거대한 석조불감이다. 남쪽과 북쪽의 감실 내부에는 각각의 불상이 등을 맞대고 있는 쌍배 좌상의 독특한 양식을 보이고 있어 역사적, 미술사적 및 학술적으로 높은 평가를 받고 있다. 그러나 이 석조불감은 특별한 보호시설 없이 옥외에 노출되어 장기간 풍화를 받아 다양한 훼손양상이 복합적으로 나타나고 있다. 따라서 상대적인 훼손 및 환경적 요인을 분석하기 위해 석조불감 내부와 외부의 온도분포와 상대습도를 일년간 모니터링 하였다. 이 결과, 석조불감의 기온 및 상대습도 연중변화는 일정한 변동률의 폭으로 증감을 반복하며 기온은 계절에 따라 상승과 감소의 경향을 뚜렷이 보이는 반면, 상대습도는 사계절 모두 높은 습도를 유지하는 것으로 나타났다. 석조불감의 내부는 높은 상대습도로 인해 표면 결로현상이 나타나고 있으며 이는 봄, 여름 및 겨울철에 관찰된다 특히 여름철은 봄과 겨울철의 합보다도 2배정도 높게 나타나며, 기온이 높고 상대습도가 거의 100%에서 일정하게 유지되므로 결로현상이 오랫동안 암석 표면에 지속되어 구성광물을 용해시키고 표면을 변질시켜 화학적 풍화를 촉진시킬 것으로 판단된다. 따라서 이 석조불감의 보존을 위해 결로현상에 영향을 미치는 상대습도의 저감방안이 필요한 것으로 나타났다.

커튼월의 단열 향상 및 결로 방지를 위한 통기구조 적용방안 연구 (Application of Ventilated Cavity for Enhancing Insulation and Preventing Condensation of Curtain-wall System)

  • 이선우
    • 설비공학논문집
    • /
    • 제29권1호
    • /
    • pp.21-28
    • /
    • 2017
  • Curtain-wall systems have been widely applied to buildings because of their lightweight and constructability characteristics. However, as curtain-wall systems include many building materials, vapor barriers can become damaged and condensation can occur. Due to the material properties of stone curtain-walls, the external appearance and structure of a building could be damaged and the insulating performance of the curtain-wall could be worse. Natural ventilation using an air cavity in a curtain-wall is expected to be effective for the prevention of condensation in inner walls and for the reduction of building cooling energy use in the summer. The purpose of this experimental study is to analyze the influence of a ventilated cavity on the insulating performance of a curtain-wall and the ventilated cavity depth and ratio of top opening needed to prevent condensation in a curtain-wall.

Mock-up 실험을 통한 통기성 커튼월의 단열 및 결로방지 성능평가 (An Experimental Study on Insulation and Preventing Condensation Performance of Ventilated Curtain Wall)

  • 이미진;이선우;여명석;김광우
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.1081-1086
    • /
    • 2006
  • Curtainwall systems has been applied to buildings widely for constructability. However, as cutainwall system include many building materials, they become to damaged vapor barrier and incur condensation. Natural ventilation of an air cavity in a curtainwall is expected to be an prevention of condensation in inner wall and reduce cooling energy in summer. The objective of this experimental study is to evaluating the insulation and condensation Performance of ventilated curtainwall with ventilated cavity depth and ratio of opening area.

  • PDF

철골조학교(鐵骨造學校) 스틸스터드 벽체(壁體)의 단열(斷熱) 및 결로방지(結露防止) 성능(性能) 평가(評價)를 위한 실험적(實驗的) 연구(硏究) (Experimental Study to Evaluate the Thermal and Condensation Performance of Steel Stud Walls in Steel-Framed Schools)

  • 유영동;김갑득
    • 교육시설
    • /
    • 제6권4호
    • /
    • pp.16-23
    • /
    • 1999
  • The thermal and condensation performance of steel stud walls are monitored in steel-framed schools of Ee-Wol Elementary School and kindergarten using temperature and humidity sensors installed. The monitoring process carried out during the summer and winter period, shows decrement effect of the external heat flow to be quite remarkable and excellent. And steel stud walls provides a highly efficient time-lag effect in spite of its light weight property, with 30 minutes to 4 hours time-lag for external heat flow, which variation mainly depends on its location of each part of the wall. Any condensation phenomena are not observed in either external or internal surfaces.

  • PDF

여름 및 겨울철 광주지역 대기 에어로졸 입자의 유기탄소 특성 (Characteristics of Organic Carbon Species in Atmospheric Aerosol Particles at a Gwangju Area During Summer and Winter)

  • 박승식;허재영;조성용;김승재;김영준
    • 한국대기환경학회지
    • /
    • 제23권6호
    • /
    • pp.675-688
    • /
    • 2007
  • To characterize organic and elemental carbon (OC and EC), and water-soluble organic carbon (WSOC) contents, daily $PM_{2.5}$ measurements were performed in August 2006 (summer) and Jan $11{\sim}Feb$ 12 2007 (winter) at an urban site of Gwangju. Daily size-segregated aerosol samples were also collected for WSOC analysis. No clear seasonal variations in EC and WSOC concentrations were observed, while seasonal differences in OC concentration, and OC/EC and WSOC/EC ratios were shown. The WSOC/OC ratio showed higher value in summer (0.56) than in winter (0.40), reflecting the greater enhancement of secondary WSOC formation at the site in summer. Secondary WSOC concentrations estimated using EC tracer method were in the range $0.0{\sim}2.1\;{\mu}g/m^3$ (average $0.42\;{\mu}g/m^3$) and $0.0{\sim}1.1\;{\mu}g/m^3\;(0.24\;{\mu}g/m^3)$, respectively, accounting for $0{\sim}51.6%$ (average 16.8%) and $0{\sim}52.5%$ (average 13.1 %) of the measured WSOC concentrations in summer and winter. Sometimes higher WSOC/OC ratio in winter than that in summer could be attributed to two reasons. One is that the stable atmospheric condition often appears in winter, and the prolonged residence time would strengthen atmospheric oxidation of volatile organic compounds. The other is that decrease of ambient temperature in winter would enhance the condensation of volatile secondary WSOC on pre-existing aerosols. In summertime, atmospheric aerosols and WSOC concentrations showed bimodal size distributions, peaking at the size ranges $0.32{\sim}0.56\;{\mu}m$ (condensation mode) and $3.2{\sim}5.6\;{\mu}m$ (coarse mode), respectively. During the wintertime, atmospheric aerosols showed a bimodal character, while WSOC concentrations showed a unimodal pattern. Size distributions of atmospheric aerosols and WSOC with a peak in the size range $0.32{\sim}0.56\;{\mu}m$ were observed for most of the measurement periods. On January 17, however, atmospheric aerosols and WOSC exhibited size distributions with modal peaks in the size range $1.0{\sim}1.8\;{\mu}m$, suggesting that the aerosol particles collected on that day could be expected to be more aged, i.e, longer residence time, than the aerosols at other sampling periods.

Unusual Radar Echo from the Wake of Meteor Fireball in Nearly Horizontal Transits in the Summer Polar Lower-Thermosphere

  • Lee, Young-Sook;Kirkwood, Sheila;Kwak, Young-Sil
    • Journal of Astronomy and Space Sciences
    • /
    • 제35권2호
    • /
    • pp.83-92
    • /
    • 2018
  • The summer polar lower thermosphere (90-100 km) has an interesting connection to meteors, adjacent to the mesopause region attaining the lowest temperature in summer. Meteors supply condensation nuclei for charged ice particles causing polar mesospheric summer echoes (PMSE). We report the observation of meteor trail with nearly horizontal transit at high speed (20-50 km/s), and at last with re-enhanced echo power followed by diffusive echoes. Changes in phase difference between radar receivers aligned in meridional and zonal directions are used to determine variations in horizontal displacements and speeds with respect to time by taking advantage of radar interferometric analysis. The actual transit of echo target is observed along the straight pathway vertically and horizontally extended as much as a distance of at least 24 km and at most 29 km. The meteor trail initially has a signature similar to 'head echoes', with travel speeds from 20 - 50 km/s. It subsequently transforms into a different type of echo target including specular echo and then finally the power reenhanced. The reenhancement of echo power is followed by fume-like diffusive echoes, indicating sudden release of plasma as like explosive process probably involved. We discuss a possible role of meteor-triggered secondary plasma trail, such as fireball embedded with electrical discharge that continuously varies the power and transit speed.

Concentration and Seasonal Variation of Particle PCBs in Air

  • Yeo Hyun-Gu;Chun Man-Young
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제21권E1호
    • /
    • pp.13-21
    • /
    • 2005
  • Atmospheric concentrations of PCBs were monitored in Ansung-city, Kyonggi province during the 2001/2002 to characterize the concentration distribution and seasonal variation of particle polychlorinated biphenyls (PCBs). Average concentration of particle bound PCB showed maximum value for penta-CBs and minimum value for octa-CBs. Seasonal contributions $(%\)$ of total particle PCBs showed the highest value in winter months and lowest value in summer month, This result indicated that concentration of total particle PCBs increased with decreasing temperature in the atmosphere. Therefore, particle PCBs were easily formed by the condensation of gas phase PCBs in winter months. The total particle PCBs exhibited an inverse correlation with temperature (p<0.01) which suggested that particle PCBs were easily formed by condensation of gaseous PCBs in winter months.