• 제목/요약/키워드: Concrete bar

검색결과 1,092건 처리시간 0.043초

중앙 보강재에 의한 철근콘크리트 기둥의 내진 강화에 관한 연구 (Study on Strengthening of Reinforced Concrete Columns by Central Element)

  • 노영곤
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.517-520
    • /
    • 1999
  • In this study, the problem of strengthening of reinforced concrete (RC) columns by a central steel section with minimum amount is taken up. For this purpose, RC columns with central reinforcing elements such as a steel bar, a steel H section and a steel pipe were taken up. To certify the effect of this way of reinforcing, experimental study using specimens of RC columns of shear span ratio of 2.5 was carried out. The variables which are considered to affect the behavior of RC columns subjected to axial load and cyclic shear load are the magnitude of axial load, tie ratio and main bar ratio. As the results of this study, the effect of a central reinforcing element for making higher the earthquake resistant properties of RC columns were observed.

  • PDF

지속 하중하에서 철근콘크리트 부재의 염화물 침투특성에 따른 철근부식에 관한 연구 (A Study on the Reinforcing Bar Corrosion Caused by Permeation of Chloride Ion Under Sustained Load)

  • 최일호;김형래;윤상천;지남용
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.779-782
    • /
    • 1999
  • This study was carried out to estimate the effects of the loading conditions on the corrosion of reinforcing bars and permeation of chloride ion. The permeation of chlorides depends not only on the transfer properties in concrete but also on the load applied in the case of reinforced concrete structures. Recent studies reported that the loading conditions affected the corrosion rate of the reinforcing bars under existence of an external current supply. But it was not reported that loading conditions affected corrosion of reinforcing bar caused by the characteristics of permeation and the process of cracking. In this experiment, it was shown that the corrosion of reinforcing bars and the characteristics of permeating were greatly affected by the loading conditions.

  • PDF

서중환경시 갱폼 거푸집 내부 철근의 온도변화 (Temperature Rise of Steel bars Located in a Gang Form Before Placing Concrete During Hot Weather Condition)

  • 김경훈;손호정;임춘근;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 추계 학술논문 발표대회
    • /
    • pp.11-12
    • /
    • 2012
  • This study investigates the temperature rise of reinforcement bars located in the middle of the form (for reinforcement concrete) during hot weather condition. The temperature was measured for three consecutive days before placing concrete. Test results showed that the temperature started to increase at 7:00 AM before sun rised, and peaked at around 2:00 PM. It was found that the thinner the diameter of a reinforcement bar, the higher is the speed of temperature rise and drop of the bar. The peak level of temperature for D13, D19, D25 and D32 was 54.4℃, 55.2℃, 56.4℃ and 60.2℃, respectively.

  • PDF

고로슬래그 미분말을 사용한 콘크리트의 방청성능에 관한 연구 (A Study on the Rust-protection Performance of Concrete using Ground Granulated Blast-furnace Slag)

  • 박상준;김동석;원철;이상수;김영진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.529-532
    • /
    • 2001
  • In this paper, rust-protection performance of concrete using ground granulated blast-furnace slag are discussed. 4 kinds of W/B in combination with 3 kinds of replacement ratio of ground granulated blast-furnace slag and 2 kinds of chloride ion contents of are selected as experimental parameters. According to the experimental results, as the replacement ratio of ground granulated blast-furnace slag is increased, the corrosion area of steel bar tends to be decreased. However, as the autoclave cycle and chloride ion contents are increased, the corrosion area of steel bar is increased. In conclusion, when the replacement ratio of ground granulated blast-furnace slag is 50%, the strength and rust-protection performance appear to be most excellent.

  • PDF

이질구조부 보강판의 길이에 따른 혼합구조보의 특성에 관한 연구 (A Study on Properties of Composite Beams according to Length of Reinforcing Plate for Different Types of Structure)

  • 이승조;박정민;김화중
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.297-302
    • /
    • 2002
  • This paper investigated the properties of flexural behavior of composite beams (end-Reinforced concrete, center-Steel concrete) according to attaching length of main bars to flange, shear reinforcing length for different types of structure. In the preceding study, structural properties of composite beams were investigated according to shear span to depth ratio, attaching method of main bars and shear reinforcing method. Based on these results, a series of experiments was carried out according to attaching length of main bar & reinforcing length for different types of structure. Consequently, as attaching length of main bar and shear reinforcing length increased, composite beams represented higher strength, ductility index and stress mechanism distributed in connection zone of different types of structure.

  • PDF

AE를 이용한 탄소섬유시트 강화 모르타르의 파괴거동에 관한 연구 (A Study on the Failure Behavior of Carbon Fiber Sheet Reinforced Mortar Using Acoustic Emission Technique)

  • 이진경;이준현;장일영
    • 콘크리트학회논문집
    • /
    • 제12권3호
    • /
    • pp.67-75
    • /
    • 2000
  • It was well recognized that the damages associated mainly with the aging of civil infrastructures were one of very serious problems for assurance of safety and reliability. Recently carbon fiber sheet(CFS) has been widely used for reinforcement and rehabilitation of damaged concrete beam. However, the fundamental mechanism of load transfer and its load-resistant for carbon fiber sheet reinforced concrete are not fully understood. In this study, three point bending test has been carried out to understand the damage progress and the micro-failure mechanism of CFS reinforced mortars. For this purpose, four different types of specimens are used, that is, mortar, steel bar reinforced mortar, CFS reinforced mortar, and steel bar and CFS reinforced morter. Acoustic Emission(AE) technique was used to evaluate the characteristics of damage progress and the failure mechanism of specimens. in addition, two-dimensional AE source location was also performed to monitor crack initiation and propagation processes for these specimens.

콘크리트용 골재의 알카리-실리카 반응의 함량 최악조건 (An Introduction of Pessimum Program for the Identification of Alkali-Aggregate Reaction)

  • 이상완;김수만;이평석
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회논문집(I)
    • /
    • pp.363-368
    • /
    • 2000
  • This paper is an introduction of pessimum program for the identification of alkali-silica reaction of alkali-aggregate reaction which is known as one of a major factor of concrete deterioration. A series of gel-pat testing program was undertaken to observe the reactivity of potentially alkali-silica reactive concrete aggregates which were found to be reactive by previous petrographic examination (ASTM C 295). And then a pessimum program was performed in accordance with mortar-bar test method (ASTM C 227) with different percentage of those reactive components included in the fine aggregate source to determine the pessimum quantity. Chert and quartzite were found to be major components of reactive mineral/rock, and the pessimum condition for chert was about 3%, even though the test was performed with up to 25% of the component. In the case of quartzite, however, the mortar-bar expansion appeared to be directly proportional to the amount of quartzite sample with increasing tested quantity up to 35%. Both of the expansion results were well 3 and 6 month specified maximum limitation of 0.05% and of 0.1% respectively.

  • PDF

쇄석 골재의 알칼리-실리카 반응에 관한 실험적 연구(제 1보 : 반응성골재의 판정과 골재혼입율이 알칼리-실리카 반응에 미치는 영향) (A Experimental Study on the Alkali-Silica Reaction of Crushed Stones (Part 1 : The Identification of Reactive Aggregate and the Influence of Aggregate Content to the Alkali-Silica Reaction))

  • 윤재환;이영수;정재동;노재호;이양수;조일호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1993년도 가을 학술발표회 논문집
    • /
    • pp.103-107
    • /
    • 1993
  • The Alkali Aggregate Reaction(AAR), reported first by T. E. Stanton in 1940, is a reaction between certain siliceous aggregate and hydroxyl ions present in the pore fluid of a concrete. The damage of concrete structures, deteriorated by AAR, have been reported since using the crushed stones caused by the exhaustion of natural aggregates. This study was performed to investigate the AAR of crushed stones using chemical analysis, polarization microscope, XRD, chemical method(KS F 2545, ASTM C 289), mortar bar method(KS F 2546, ASTM C 227) and Scanning Electron Microscope(SEM) and Energy Dispersive X-ray Analysis (EDXA) of reaction products by AAR in mortar bar.

  • PDF

강섬유 보강 철근 콘크리트 단순보와 연속보의 거동 (The Behavior between Steel fiber Reinforced Concrete Both Simple and Continuous Beams)

  • 곽계환;김원태;김기순;장화섭
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.167-174
    • /
    • 2003
  • It is absolutely natural to be interested in durability and safety of the structure under shear behavior. To fulfill this desire, a comparison on the shear behavior between steel fiber reinforced concrete both simple and continuous beams is done to use in the field working. Several operations are conducted : First of all, plan for optimal combination is standardized. Second, resistance for shear has been generalized in that it is decided by combination of individual elements. Third, as the fracture of tensile bar leads to destruction of specimen, shear behavior of whole specimen is decided by stress working on tensile bar. It should be generalized for other specimens also. Forth, evidence of the softness of steel fiber reinforced concrete beam by experiment lead to application in the fields. Finally, numeral values of the steel fiber reinforced concrete are analyzed and the result is compared to those of experiments. With these consequences, this study was done for the application to dynamic structures such as bridges and the repair and rehabilitation.

  • PDF

Gr.80 확대머리철근의 원전구조물 적용을 위한 ACI 349 코드개정에 관한 연구 (ACI 349 Code Change to Use the Gr.80 Headed Deformed Bars in Nuclear Power Plant Structures)

  • 이병수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 춘계 학술논문 발표대회
    • /
    • pp.200-201
    • /
    • 2017
  • Generally, a lot of reinforcements are used in nuclear power plant concrete structures, and it may cause several potential problems when concrete is poured. Because of the congestion caused by hooked bars, embedded materials, and other reinforcements, it is too difficult to pour concrete into structural member joint area. The purpose of this study is to change ACI 349 Code for using the large-size(57mm) and high-strength(Gr.80) headed deformed bars instead of standard hooked bars in nuclear power plant concrete structures in order to solve the congestion problems.

  • PDF