• Title/Summary/Keyword: Concrete Filled Tube(CFT)

Search Result 218, Processing Time 0.026 seconds

An Experimental Study on Structural Performance of Welded Built-up Square CFT Stub Columns (용접조립 각형 CFT 단주의 구조특성에 관한 실험적 연구)

  • Lee, Seong Hui;Choi, Young Hwan;Yom, Kyong Soo;Kim, Jin Ho;Choi, Sung Mo
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.5
    • /
    • pp.645-653
    • /
    • 2008
  • Welded built-up square tubes are manufactured by flare welding at the center of the column width for cold-formed L-shaped four-piece plates and improved composite effect of concrete and steel by vertical inner anchor. Also, the axial resistance of concrete is increased by the thinness of the steel column, and the composite effect of concrete and steel prevents the steel column from local buckling. In this study, we introduced a manufacturing method of built-up square column steel square concrete-filled tubular column with vertical inner anchor and superior structural performance of the square stub column verified by the structural test for 15 specimens with parameters of shape of tube (built-up square tube, general steel tube), width over thickness of the steel tube (B/t=50, 58, 67) and the strength of concrete (f'c=10MPa, 50MPa).

An Experimental Study on the Temperature Distribution of Square CFT Columns According to the Types of Fire Protection (내화피복 종류에 따른 각형 CFT기둥의 온도분포에 관한 실험적 연구)

  • Kim, Hae-Soo;Lee, Chy-Hyoung
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.6
    • /
    • pp.523-532
    • /
    • 2010
  • Concrete-filled square steel tube (CFT) columns have inherently high fire resistance and load-bearing capacity. Nevertheless, it is sometimes necessary to improve their fire resistance using external fire protection. This paper presents the experimental results of the temperature distribution of CFT columns with fire protection. A fire load test was carried out by exposing small-scale specimens to heat in an electric furnace that was especially built for testing loaded columns. The temperature distribution of CFT columns under constant axial loads was determined, as were its significant parameters, such as the types of fire protection and thickness, the thickness of the square CFT, and the fire duration times. The results of this study showed the temperature distribution of each specimen of the electric furnace and the temperature distribution properties of concrete and steel. In addition, the axial displacement and local buckling behavior of CFT columns based on temperature changes was observed.

Structural Behavior of Two-Seam Cold Formed Square CFT Column to Beam Connections (2심 냉간성형 각형 CFT기둥-보 접합부의 구조거동)

  • Oh, Heon-Keun;Kim, Sun-Hee;Park, Chan-Myun;Choi, Sung-Mo
    • Journal of Korean Association for Spatial Structures
    • /
    • v.12 no.4
    • /
    • pp.81-90
    • /
    • 2012
  • The concrete-filled tube (CFT) column has the excellent structural performance. But it is difficult to connect with column and beam because of closed section. Its Solution, 2 members of ㄷchennel in which Internal diaphragm is installed were welded beforehand and the method of making Rectangular Steel Tube was proposed. According to upside and downside junction shape, Internal diaphragm suggested as symmetric specimen and asymmetric specimen. The upper and lower diaphragm of the Symmetric specimen used the same horizontal and The upper diaphragm of the Asymmetric specimen used the horizontal plate and the lower diaphragm used the vertically plate. In this research, 4 T-shape column to beam steps connections were tested with cyclic loading experiment in order to evaluate the structural capability of the offered connection. Symmetric specimens be a failure in 0.03rad from beam flange. And Asymmetric specimens be a failure in 0.05rad from column interface. The comparison results of All specimens shown similar to energy absorption capacity in 0.02rad.

The Study on the Fire Resistance Performance of the CFT (Concrete filled Tube) Column According to the Concrete Compressive Strength and Load Ratio (콘크리트 압축강도 및 하중비에 따른 CFT기둥의 내화성능에 관한 연구)

  • Cho, Kyung-Suk;Kim, Heung-Youl;Kim, Hyung-Jun;Kwon, In-Kyu
    • Fire Science and Engineering
    • /
    • v.24 no.2
    • /
    • pp.44-51
    • /
    • 2010
  • This study, to develop the technology of the fire resistance design of CFT structure based on fire resistance performance design, was suppose to use as basic data for performance design through a measure of temperature and deformation of the CFT specimen as parameter is the concrete compressive strength and load ratio. In accordance with KS F 2257-1 and 7, 24 MPa and 40 MPa and the load ratio of 0.9, 0.6 and 0.2 were imposed on a square column and as a result of evaluating in accordance with the fire resistance criteria, in case of 24 MPa, the fire resistance performance was improved by 73 minutes when the load ratio was reduced by 0.3. And when it comes to 40 MPa, the fire resistance was 31 minutes and 180 minutes when a load ratio was 0.6 and 0.2, respectively. As a result of evaluating fire resistant performance depending on variation of internal concrete strength, it proved that the higher the strength the lower the fire resistance.

Evaluation of ductility and response modification factor in moment-resisting steel frames with CFT columns

  • Hashemi, Seyed Sh.;Sadeghi, Kabir;Vaghefi, Mohammad;Shayan, Kaveh
    • Earthquakes and Structures
    • /
    • v.12 no.6
    • /
    • pp.643-652
    • /
    • 2017
  • One of the methods to strengthen the structures against the seismic lateral loading is the employment of the composite columns. A concrete-filled tube (CFT) has the cumulative advantages of steel and concrete. Concrete-filled steel tube columns have been widely used in the moment-resisting frame (MRF) structures, located in both non-seismic zones and high-risk seismic zones. In this paper, the results of studies on two important seismic parameters of ductility and the response modification factor (RMF) of the MRFs with CFT columns are submitted. While the studies are carried out, the effects of span length-story height ratio, the strength of materials and seismic behavior of MRFs are considered. In this regard, the ductility, RMF and the strength of 36 models of the steel MRFs with CFTs are analyzed. The fiber plastic hinges numerical simulation and pushover analysis method are used in the calculations. Based on the obtained results, the RMFs suitable for the 5-, 10- and 15- story frames are proposed.

Ductility Capacity for Concrete Filled Steel Circular Tubes Reinforced by Carbon Fiber Sheets(CFSs) (탄소섬유쉬트로 보강된 콘크리트충전 원형강관기둥의 연성능력)

  • Park, Jai-Woo;Hong, Young-Kyun;Choi, Sung-Mo
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.2
    • /
    • pp.185-195
    • /
    • 2010
  • This paper presents the experiment results for a CFT column confined by carbon fiber sheets(CFSs) under an axial load. Nine specimens were constructed and axial compression tests were conducted. The main experiment parameters were diameter-thickness ratio(D/t), reinforcing CFSa, and the attachment of a cushion gap between surface of steel tube and CFSs. The load-displacement curves of the specimens were obtained from the compression tests. Finally, it was concluded that the CFT column with a gap had grater ductility capacity improvement that the CFT column confined by CFSs.

An Experimental Study on the Behavior of Column-to-Column Connections of Prefabricated Concrete Filled Tubes (프리훼브 콘크리트충전 각형강관기둥 이음부의 휨거동에 관한 실험적 연구)

  • Kim, Jae Hoon;Lee, Myung Jae
    • Journal of Korean Society of Steel Construction
    • /
    • v.11 no.3 s.40
    • /
    • pp.311-318
    • /
    • 1999
  • Concrete filled tubular(CFT) members have many structural and constructional advantages. The prefabrication of CFT members can be thought an idea for the good qualify control of concrete. The objective of this study is to suggest the construction method of prefab CFT beam-columns. Tests are performed to understand their structural behaviors. The opening space between prefab CFT members and the size of tubular members are the parameters of this study. The results of this study will be based on the suggestion of prefab CFT.

  • PDF

Long-Term Behavior of CFT Column under Central Axial Load (중심축 하중을 받는 CFT 기둥의 장기거동에 관한 연구)

  • 권승희;김진근
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.1
    • /
    • pp.77-85
    • /
    • 2001
  • Concrete filled steel tubular (CFT) columns are becoming popular in structural applications. The increased popularity comes from their excellent structural properties such as high strength, high ductility, and large energy absorption capacity. However, the disadvantage feature of CFT column is the difficulty in predicting its time dependant characteristic (i.e., creep and shrinkage) of inner concrete. The time dependent behavior of CFT column can cause serious serviceability problems. Therefore, it is necessary to investigate the long term behavior of CFT column. This paper presents analytical and experimental studies on long-term behavior of CFT-column under a central axial loading. Two loading cases are considered in the research; (1) the load applied only at the inner core concrete of CFT-column and (2) the load applied simultaneously on both concrete and steel tube. Analysis method using the bond strength model is proposed and conclusions on long-term properties of CFT-column can be derived from the results.

Research on the Mock-up for CFT Using 100MPa High Strength Concrete and 800MPa High Strength Steel (800MPa 고강도 강재 및 100MPa 초고강도 콘크리트를 활용한 CFT 합성 구조 시스템 개발을 위한 현장 성능평가에 관한 연구)

  • Kim, Woo-Jae;Lee, Youg-Do;Park, Hee-Gon;Lee, Jae-Sam;Jung, Sang-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.05b
    • /
    • pp.35-37
    • /
    • 2011
  • This study was a comparison result between the laboratory and mock up test to apply the ultra high strength concrete to CFT(Concrete Filled Tube) structure. The investigated result of tendency and quality similarity of each specimen, was set up a management range according to checking the validity and suitability analysis. Also, It wil be utilized to data as construction guidelines of CFT.

  • PDF

Evaluation for fire resistance performance of high strength CFT with loading (재하하중에 따른 고강도 CFT의 내화성능 평가)

  • Hong, Seok-Beom;Yoo, Jo-hyeong;Kim, Woo-Jae;Lee, Ji-Hwan
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.184-185
    • /
    • 2013
  • Concrete filled steel Tube(CFT) columns have great strength but also fire resistance performance due to the heat storage effect of concrete. In this research, we focus on the fire performance of CFT using 100 MPa concrete without fire protection. We use steel fiber and nylon fiber for fire resistance. We perform the fire test of CFT specimen with loading 200, 300 and 400 ton. To investigate the effect of loading to fire resistance, we compare the fire resistance time according to the loading.

  • PDF