Abstract
Concrete-filled square steel tube (CFT) columns have inherently high fire resistance and load-bearing capacity. Nevertheless, it is sometimes necessary to improve their fire resistance using external fire protection. This paper presents the experimental results of the temperature distribution of CFT columns with fire protection. A fire load test was carried out by exposing small-scale specimens to heat in an electric furnace that was especially built for testing loaded columns. The temperature distribution of CFT columns under constant axial loads was determined, as were its significant parameters, such as the types of fire protection and thickness, the thickness of the square CFT, and the fire duration times. The results of this study showed the temperature distribution of each specimen of the electric furnace and the temperature distribution properties of concrete and steel. In addition, the axial displacement and local buckling behavior of CFT columns based on temperature changes was observed.
콘크리트가 충전된 각형강관기둥(이하, 각형 CFT기둥)은 높은 내화성능과 하중저항능력을 보유하고 있지만, CFT기둥의 외부에 내화피복을 함으로써 기둥의 내화성능을 향상시킬 필요가 있다. 본 연구는 내화 피복된 각형 CFT기둥의 온도분포에 대한 실험결과이다. 실험을 위하여 특수 제작된 전기로를 이용하여 축소모형 시험체의 재하가열실험을 수행하였다. 축하중을 받는 내화 피복된 각형 CFT기둥의 온도 분포 특성을 파악하기 위하여 내화피복의 종류와 두께, 강관의 두께 및 가열시간 등을 변수로 설정하였다. 실험결과 전기로의 온도에 따른 시험체별 온도분포와 콘크리트와 강재의 온도분포 특성을 파악하였다. 또한 시험체의 온도변화에 따른 축변위와 국부좌굴 등의 거동을 파악하였다.