• 제목/요약/키워드: Computerized Tomography Unit

검색결과 12건 처리시간 0.019초

종합병원 컴퓨터단층촬영유니트의 건축계획에 관한 연구 (A Study on the Planning of the Computerized Tomography Unit in General Hospital)

  • 윤우용;채철균
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제19권1호
    • /
    • pp.59-66
    • /
    • 2013
  • Purpose: Although Computerized Tomography is one of the most useful diagnosis devices and Frequency of use by all kind of patient is higher than other device, it can be hardly to find out adequate data to planning of Computerized Tomography Unit. So questions have been raised about how to organize the unit. Methods: In order to suggest architectural guideline of Computerized Tomography Unit, expert interview, field survey and analysis to the floor plan have been conducted in this article. The area calculation was based on center line. Results: This article suggests a number of the guideline and the example of the planning which contains how to design Computerized Tomography Unit. Especially, in the case of the example on the planning, main points of the guideline is reflected. Implications: The result of this survey would be useful as a reference when the architect tries to design Computerized Tomography unit.

Three-dimensional functional unit analysis of hemifacial microsomia mandible-a preliminary report

  • Choi, Ji Wook;Kim, Byung Hoon;Kim, Hyung Soo;Yu, Tae Hoon;Kim, Bong Chul;Lee, Sang-Hwy
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제37권
    • /
    • pp.28.1-28.7
    • /
    • 2015
  • Background: The aim of this study was to present three-dimensional (3D) structural characteristics of the mandible in the hemifacial microsomia. The mandible has six distinct functional units, and its architecture is the sum of balanced growth of each functional unit and surrounding matrix. Methods: In order to characterize the mandibular 3D architecture of hemifacial microsomia, we analyzed the mandibular functional units of four hemifacial microsomia patients using the 3D reconstructed computed tomography (CT) images. And we compared the functional unit size between affected and non-affected side. Results: The length of condyle and angle showed significant differences between affected and non-affected sides. However, the length of mandibular body showed insignificant differences. The size differences between affected and non-affected side were observed at the condyle, angle, and body in descending order. Conclusions: This preliminary study suggests that the main etiopathogenic units are condyle and angle in the hemifacial microsomia mandible. Further investigation with the increased number of subjects will be helpful to establish treatment modality by etiopathogenic targeting of hemifacial microsomia.

우리나라 병원의 경영전략 실태 (Management Strategy of Hospitals in Korea)

  • 문옥륜;이기효
    • 한국병원경영학회지
    • /
    • 제1권1호
    • /
    • pp.108-135
    • /
    • 1996
  • This paper investigates the current feature of management strategy of hospitals in Korea, and examines the relationships between adoption of a particular strategic orientation and the hospitals environmental and organizational characteristics, strategic behaviors and management improvement activities, and financial performance. Data were collected from CEOs of 88 hospitals among 650 hospitals for a 13.5% response rate using the self-administered questionnaire by mail survey. The major findings that obtained are as follows: 1. Only 37.2% of response hospitals carried out strategic planning, Most of these hospitals established the first strategic planning in 1991(81.3%) and renovated strategic planning by 4 or 5 years(56.3%), and modified strategic planning with flexibility(59.4%). Most strategic plans were documented, but informalized(68.8%). And only 29.0% of these hospitals had independent planning division. 2. Hospital services that CEOs assessed rank ordered for their impact on profitability are as follows: i)diagnostic ultrasound facility, computerized tomography scanner, obstetric inpatient unit, therapeutic X-ray, and physical therapy at present. ii)diagnostic ultrasound facility, physical therapy, computerized tomography scanner, emergency department, and health screening at future. And the services rank ordered that CEOs hoped to introduce are as follows: emergency department, physical therapy, health screening, volunteer services, and computerized tomography scanner. 3. Using a typology developed by Miles and Snow(l978), the strategic orientation of response hospitals are shifting significantly from defenders in the past to analyzers in the present, and to prospectors in the future(p<.01). 4. With regard to hospital environmental and organizational characteristics such as ownership, physician training, location, bed size, and hospital management training career and specialty of CEOs, the four strategic orientation archetypes varied not significantly. But, hospitals with a analyser orientation in the present and a reactor orientation in the future perceived competition significantly higher than the other three archetypes(p<.05). 5. The four archetypes rank ordered in terms of appling strategic behaviors and management improvement activities are as follows: prospector, analyzer, reactor, and defender. 6. The four archetypes differed significantly in terms of their financial performance using revenue per bed(p<.05). Reactors and prospectors in terms of total revenue per bed, prospectors in terms of outpatient revenue per bed, and reactors and prospectors in terms of inpatient revenue per bed had the best performance.

  • PDF

컴퓨터 영상을 이용한 임플란트 식립부위의 골밀도와 조직학적 연구 (BONE DENSITY AND HISTOMORPHOMETRY ASSESSMENT OF DENTAL IMPLANT USING COMPUTERIZED TOMOGRAPHY)

  • 손장호;최병환;박수원;조영철;성일용;이지호;변기정
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제31권2호
    • /
    • pp.136-142
    • /
    • 2009
  • Bone density in the recipient implant site seems to be an important factor for long term success of endosseous implants. Preoperative evaluation of bone density is very helpful to assist the clinician with the treatment planning of implant therapy. Accurate information on bone density will help the surgeon identify suitable implant sites, thereby improving the success rate of the procedure. Purpose; The aim of this study was to evaluate a correlation between bone density measured preoperatively with computerized tomography and histologically measured bone density by bone biopsy. Patients and methods; Twenty seven patients were selected. All the patients were in good health, with no systemic disorder and additional bone graft. Preoperatively the patients underwent CT scanning to evaluate Houmsfield Unit(HU). Each patients wore a surgical template for implant placement. During surgery 2mm in diameter and 6mm in length specimens were taken. Histomorphometric analysis was performed using digitalized image analysis software Axiovision 4.3. Also, the Resonance frequency analysis(RFA) and insertion torque values were recorded. Results; The highest histomorphometric values was found in the posterior mandible $32.3{\pm}3.8$, followed by $29.9{\pm}2.6$ for the posterior maxilla, $29.4{\pm}2.6$ for the anterior maxilla, $28.6{\pm}2.3$ for the anterior mandible(p=0.214). The hounsfield unit was $989.2{\pm}258.1$ in the posterior mandible, $845.0{\pm}241.5$ in the anterior maxilla, $744.5{\pm}92.6$ in the anterior mandible, $697.3{\pm}136.9$ in the posterior maxilla(p=0.045). This results may suggest that there are strong correlation between the histomorphometric values and hounsfield unit(r=0.760, p<0.05). The RF measurements were $81.9{\pm}2.4$ ISQ in the posterior mandible, $79.0{\pm}1.4$ ISQ in the anterior mandible, $78.3{\pm}4.6$ ISQ in the posterior maxilla, $76.5{\pm}5.0$ ISQ in the anterior maxilla(p=0.048). The insertion torque values was $43.2{\pm}4.2\;Ncm$ in the posterior mandible, $42.0{\pm}0.0\;Ncm$ in the anterior mandible, $41.3{\pm}4.1\;Ncm$ in the posterior maxilla, $40.8{\pm}3.8\;Ncm$ in the anterior maxilla(p=0.612). This results may suggest that there are statistical significance between the hounsfield unit and the insertion torque values(r=0.494, p<0.05), the histomorphometric values and the insertion torque values(r=0.689, p<0.05). But there was no correlation between histomorphometric values and ISQ. There was no statistical significance in age and gender effect on parameters. Conclusions; There was significant correlations between bone density and implant stability parameters. The bone density measurements using preoperative CT may help clinicians to predict primary stability before implant insertion, which is associated with implant survival rates.

Cone Beam Computed Tomography를 이용한 상악 임플란트 식립 전후의 골밀도 변화에 관한 연구 (ASSESSMENT OF BONE DENSITY ON MAXILLA AFTER IMPLANTATION WITH CONE BEAM COMPUTED TOMOGRAPHY)

  • 최정훈;이주민;김용덕;신상훈;정인교
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제32권3호
    • /
    • pp.229-235
    • /
    • 2010
  • Purpose: This study examined the significance of increased bone density according to time after implantation on maxilla using demographic data with CBCT and compared the bone density between before vs. after implantation using the Hounsfield index. Materials and Methods: Twenty-five implant site on maxilla were selected. Cone-beam computerized tomography (CBCT) scans were used for the analysis. The implant sites were evaluated digitally using the Hounsfield scale with EzImplant TM and the results were compared over time. Statistical data over time was carried out to determine the correlation between the recorded Hounsfield unit (HU) over time and gender difference using repeated ANOVA. Results: The bone density of implantation site over time showed an increase in the HU mean values. Immediately after implantation, bone density was significantly increased than bone density before implantation. Until 6 month follow-up, bone density showed stable increasement. There is no significant difference on gender. Conclusions: Using CBCT, bone density increased over time after implantation on maxilla. Bone density measurements using CBCT might provide an objective assessment of the bone quality as well as the correlation between bone density and stability of implant.

시간단축 알고리즘을 통한 3D 동영상 구현 (Implementation of 3D Video using Time-Shortening Algorithm)

  • 신진섭;정찬웅
    • 한국인터넷방송통신학회논문지
    • /
    • 제20권6호
    • /
    • pp.123-128
    • /
    • 2020
  • 본 논문에서는 3차원 동영상을 구현하기 위하여 인체에 유해한 방사능 피폭량이 부챗살 형태의 Fan Beam 보다 상대적으로 적은 원추형 Cone Beam CT 시스템을 설계하였다. 설계된 시스템은 X-ray가 조사된 각도에서 획득한 데이터를 영상처리부로 전송하고 영상을 구성하는 계산 속도를 빠르게 하기 위하여 초월함수가 보다 적은 3단계 회전 행렬을 이용하여 3차원 영상을 구현하는 회전 기반법을 사용하였다. 본 연구에서는 3차원 영상을 구성하는 시간단축을 통해 초당 3~5장의 영상을 얻음으로써 3차원 동영상을 실시간으로 구현하였으며 기존의 데이터 적층 방법에 비해 본 논문에서 사용한 회전 기반법이 우수함을 증명하였으며 단점 및 해결방법 제시하였다.

3D 동영상획득을 위한 Cone-Beam 형 X-Ray CT 시스템 구현에 관한 연구 (The Study on the Implementation of the X-Ray CT System Using the Cone-Beam for the 3D Dynamic Image Acquisition)

  • 정찬웅;전계석
    • 한국음향학회지
    • /
    • 제28권4호
    • /
    • pp.370-374
    • /
    • 2009
  • 본 논문에서는 3차원 동영상을 구현하기 위하여 인체에 유해한 방사능 피폭량이 부챗살 형태의 Fan Beam 보다 상대적으로 적은 원추형 Cone Beam CT 시스템을 설계하였다. 설계된 시스템은 X-ray가 조사된 각도에서 획득한 데이터를 영상처리부로 전송하고 영상을 구성하는 계산 속도를 빠르게 하기 위하여 초월함수가 보다 적은 3단계 회전 행렬을 이용하여 3차원 영상을 구현하는 회전 기반법을 사용하였다. 본 연구에서는 3차원 영상을 구성하는 시간단축을 통해 초당 3~5장의 영상을 얻음으로써 3차원 동영상을 실시간으로 구현하였다.

방사선치료 시 Metal artifact reduction Algorithm의 임상적용 유용성평가 (A Study on Usefulness of Clinical Application of Metal Artifact Reduction Algorithm in Radiotherapy)

  • 박자람;김민수;김정미;정현숙;이충환;백금문
    • 대한방사선치료학회지
    • /
    • 제29권2호
    • /
    • pp.9-17
    • /
    • 2017
  • 목 적: 방사선치료에서 CT number에 의해 나타나는 조직의 묘사 및 전자밀도는 CT(Computed Tomography)기반의 전산화치료계획 정확성을 보장하는데 중요한 역할을 한다. 하지만 체내의 금속 이식물은 CT number의 정확성을 감소시킬 뿐 아니라 조직 묘사에 대한 불확실성을 나타내기 때문에 임상에서는 metal artifact를 감소시킬 수 있는 알고리즘이 개발되었다. 이에 본 연구에서는 본원에서 사용하고 있는 GE사의 SMART MAR의 CT number 정확도를 평가하고 방사선치료에서의 유용성에 대해 평가하고자 한다. 대상 및 방법: 영상평가를 위해 CIRS ED phantom을 이용하여 6개 조직의 rod를 삽입하여 동일한 체적의 ROI를 형성 후 original 영상을 획득하고 의료용 티타늄 rod를 삽입하여 non-SMART MAR 영상과 SMART MAR영상을 획득하여 CT number와 SD값을 비교하였다. Metal artifact로 인해 CT number 변화에 따른 선량변화 확인을 위해 전산화계획시스템 Epclipse를 사용하여 CIRS ED phantom CT 영상에 PTV를 형성하여 original 영상을 획득하고 편측 티타늄 삽입, 양측 티타늄 삽입 영상을 획득하여 non-SMART MAR와 SMART MAR영상에 동일한 치료계획을 수립하여 PTV가 받는 평균처방선량, HI(Homogeneity Index), CI(Conformity Index)를 비교, 분석하였다. 흡수선량 측정은 원통형 아크릴 팬텀과 0.125 cc ionchamber, electrometer를 이용하여 선량변환상수(cCy/nC)를 계산하고 CIRS phantom을 이용하여 편측, 양측 티타늄 rod를 삽입한 영상으로 non-SMART MAR와 SMART MAR 영상을 획득하여 동일한 지점에서의 흡수선량을 측정하여 전산화치료계획상의 point dose와 비교하였다. 결 과: 영상평가 결과 CT number는 non-SMART MAR영상보다 SMART MAR 영상이 original영상에 더 유사한 값이 나왔고 SD값은 SMART MAR영상에서 더 감소되었다. 선량평가 결과 평균처방선량과 HI 및 CI 값은 SMART MAR 영상보다 non-SMART MAR 영상이 original 영상에 더 근접한 결과가 나왔지만 통계적으로 유의하지 않았다. 흡수선량 측정결과 치료계획상의 point dose와 실제 흡수선량과의 차이가 non-SMART MAR의 영상에서는 각각 2.69, 3.63 %의 차이가 있었지만 SMART MAR영상에서는 0.56, 0.68 %로 감소하였다. 결 론: 금속 이식물을 삽입한 환자의 CT 영상에 SMART MAR를 적용했을 때 CT number 정확성 상승 및 SD 감소로 영상의 질이 향상되므로 종양과 정상조직의 윤곽도 생성 및 선량계산 시 유용할 것으로 사료된다.

  • PDF

May-Thurner 증후군과 동반된 하지 심부정맥혈전환자에서 혈전제거술과 스텐트삽입술 (Pharmaco-mechanical Thrombectomy and Stent Placement in Patients with May-Thurner Syndrome and Lower Extremity Deep Venous Thrombosis)

  • 전용선;김영삼;조정수;윤용한;백완기;김광호;김정택
    • Journal of Chest Surgery
    • /
    • 제42권6호
    • /
    • pp.757-762
    • /
    • 2009
  • 배경: May-Thurner 증후군은 좌측장골정맥이 우측장골동맥에 의해 눌리어 정맥 환류장해에 의해 혈전증을 일으키는 것을 말한다. 저자들은 심부 정맥혈전중의 치료를 위해 시행한 혈전 제거-용해술 및 스탠트 삽입술의 결과를 분석하고자 한다. 대상 및 방법: May-Thurner 증후군과 동반된 하지 심부정맥혈전증으로 진단받고 좌측 장골정맥에 스탠트를 삽입한 34명(평균연령 $64.6{\pm}13.7$세, 여자 25(74%)명)을 대상으로 하였다. 시술은 흡인성 혈전제거와 혈전용해 후 분지성 협착이 있는 곳에 Wall stent를 삽입하고 풍선 확장을 하였다. Multi side hole 카테타를 혈전이 있는 부위에 위치시키고 Urokinase를 시간당 8만에서 12만 International Unit을 1일 또는 2일 동안 주입하였다. 시술 중 폐동맥혈전색전증을 방지 하기 위하여 대부분 환자에서 시술 전 일시적 하대정맥 여과기(IVC Filter)를 삽입하였다. 퇴원 후 3개월간 경구용 와파린을 투여 하였으며 퇴원 전과 퇴원 후 6개월에 Multi Detector Computerized Tomography (MDCT) 혈관촬영을 이용하여 혈전의 유무를 판단하였다. 결과: 시술 48시간 이내 부종과 동통이 완전하게 소실된 환자가 2 (6%)명이었으며 증상의 완화가 있는 환자가 28 (82%)명, 증상의 호전이 없는 환자가 4 (12%)명이었다. 퇴원 시 MDCT혈관촬영에서 9 (26%)명에서 혈전없음, 21 (62%)명에서 부분 혈전, 그리고 4명(12%)에서 폐쇄소견을 보였다. 퇴원 6개월 후에 2명을 제외한 32명이 추적 MDCT혈관촬영을 하였는데 23 (72%)명에서 혈전없음을 9 (26%)명에서는 부분혈전이 관찰 되었다. 평균 5.6개월 관찰기간 동안 2 (6%)명에서 심부정맥혈전이 재발되어 재입원하였으며 하지 부종과 통증을 동반한 혈전 후 증후군은 9예(26%)에서 발생하였다. 결론: May-Thurner 증후군과 동반된 하지 심부정맥혈전환자에서 심부정맥혈전의 제거와 혈전용해술과 함께 시술된 스탠트 삽입은 효과적인 치료 방법으로 생각된다.

가상현실 기술을 활용한 방사선치료 교육 콘텐츠 제작 구현 (Implementation of Radiotherapy Educational Contents Using Virtual Reality)

  • 권순무;심재구;천권수
    • 한국방사선학회논문지
    • /
    • 제12권3호
    • /
    • pp.409-415
    • /
    • 2018
  • 스마트기기기의 발전으로 일상생활에 큰 변화를 가지고 왔으며, 가장 크게 변화된 영역 중 하나가 가상현실 영역이다. 가상현실이란 디스플레이 장치를 이용해 이미 만들어진 3차원 고해상도 이미지를 마치 자신이 그 속에 존재하는 것과 같은 착각을 일으키는 기술이다. 실습장비가 구축되지 않은 교과목의 경우 시청각 자료에 의존할 수밖에 없어 실습 집중도 및 수업에 대한 질적 저하 발생하고 있는 현실이다. 방사선과 학생들에게 효과적인 교재 개발을 위해 가상 현실을 이용하였다. 가상현실을 이용한 동영상 교보재 제작을 위해 방사선종양학과가 개설된 병원을 선정하여 2017년 7월부터 9월에 촬영을 2회 실시하였다. 방사선종양학과 업무 흐름도를 고려하여 동영상을 제작하였으며, 전산화단층모의치료실 및 선형가속기실 두 군데에서 촬영을 진행하였다. 동영상 촬영에 앞서 각각에 대한 시나리오 및 촬영 동선을 사전 체크하여 동영상 편집을 용이하게 할 수 있도록 사전 작업을 진행하였다. Window XP 운영체제를 사용하는 PC환경에서 모델링과 맵핑 작업을 실시하였다. 대표적인 가상현실 카메라인 고프로 Hero4 2대를 이용하여 화소는 4K UHD: 약 800만 화소 해상도는 $3,840{\times}2,160/4,096{\times}2,160$ 두 개를 사용하였으며, 동영상 제작 후 편집은 프로그램 어도비프리미어 CC, 에프터이펙트, 포토샵, 일러스트를 사용하였다. 총 재생 시간은 가상현실을 이용한 교보재 제작 시 구토 및 어지러움증이 발생하지 않는 시간 5분 내외로 편집을 진행하였다. 동영상 구성은 도입, 시설 설명, 장비 설명, 교과 설명 및 정리로 진행하였으며, 동영상 촬영 후 편집 기간은 약 2주 정도 소요되었다. 현재 개발된 가상현실 방사선과 교육콘텐츠는 다양한 기관에서 활용할 수 있도록 시장을 확보하고 홍보를 확대하는 작업을 추진하고 있다. 향 후 가상현실을 체험한 학습자들을 대상으로 가상현실을 이용한 방사선과 교육 콘텐츠에 대한 만족도 및 학습 효능감에 대해 조사하여 가상현실 기술을 이용한 교보재에 대한 학습 콘텐츠 유용성을 평가하여 효과적인 임상실습 환경을 제공하고자 한다.