• Title/Summary/Keyword: Computer software

Search Result 8,400, Processing Time 0.035 seconds

Design Trend and Improvement Strategies of Contents Developed by Teachers -Focus on Prizewinner of the Research Competition on Educational Informatization- (교사 개발 콘텐츠의 설계 동향과 개선 방안 -교육정보화연구대회 입상작을 중심으로-)

  • Jo, Miheon
    • Journal of The Korean Association of Information Education
    • /
    • v.19 no.3
    • /
    • pp.311-322
    • /
    • 2015
  • This study analyzed the trend and problems in the design of contents developed by teachers, and suggested strategies for improvement. It analyzed the contents ranked as the first level in the Research Competition on Educational Informatization for the last 3 years. Concerning the 8 types of instructional activities and the 6 types of knowledge acquisition, most contents took limited types(i.e., the individual tutoring type, the concept learning type and the principle learning type). In addition, when the contents were evaluated according to the quality certification criteria for educational software, it was found that the quality level of the design was low in many criteria. When the content analysis was applied for the in-depth analysis of design characteristics, various problems were found in the areas such as evaluation, feedback and learning objectives. Also other common problems were found in the design areas such as level-based differentiated learning, interaction between students and contents, presentation of text and narration, utilization of information on a student, screen design, the content level appropriate for students. In relation to the problems found from the analysis, some strategies for improvement were suggested concerning the following topics: question selection and guidance for evaluation, content and types of feedback, statement of learning objectives, selection of content, interaction, and screen design.

A STUDY ON THE FACIAL ESTHETIC PREFERENCES AMONG KOREAN YOUTHS: ASSESSMENT OF PROFILE PREFERENCES (한국 젊은이의 안면미 선호경향에 관한 연구 : 얼굴의 측모평가를 중심으로)

  • Song, Sejin;Choi, Ik-chan
    • The korean journal of orthodontics
    • /
    • v.22 no.4 s.39
    • /
    • pp.881-920
    • /
    • 1992
  • This study was designed to assess profile preferences among Korean youths in the year 1992. Facial esthetics was evaluated by means of silhouette profiles, eliminating the influence of a number of aspects that may affect judgment when normal lateral photographs are used. The main points of preference to be clarified here are as follows. First, on facial convexity, Second, on nasion depth, Third, on mentolabial sulcus depth, Fourth, on the position of upper and lower lips, Fifth, on facial type according to Angle's classification of malocclusion, Sixth, on Song's tangents. The 54 subjects printed in questionnaire as black and white silhouettes were selected from 300 tracings from cephalometric radiographs of people whose age ranging from 11 to 20 years. Photographs of six female subjects were retouched by computer graphic software and printed in color and black/white photographs which were used for adaptation of eyes of participants in selecting profiles in silhouette. They constitute 2 questions. The 54 subjects were grouped as 22 questions, each of them composed of 6 subjects, according to the aspects to be clarified. Twenty four questions in total were asked to assess profile preferences. For the assessment, the profile line, the facial esthetic triangle, Song's tangents, and Angle's classification of malocclusion were introduced. The profile line is composed of 11 component points which are Trichion, Glabella, Nasion, Pronasale, Subnasale, Labrale superius, Stomion, Labrale inferius, Supramentale, Pogonion, and Gnathion. The facial esthetic triangle is composed of 3 tangents: A-tangent which is the tangent of dorsum of nose, B-tangent which is the line passing through Sn and Ls, and C-tangent which is drawn on the turning point of the curve which lies between mentolabial sulcus (Sm) and pogonion (Pg). Angle's classification has 3 types of malocclusion which are Class I, Class II, and Class III. Class II malocclusion is subdivided into Division 1 and Division 2. The participants of the survey were composed of 861 college students (448 male students, 413 female students) whose majors grouped as Fine Arts. Liberal Arts, and Natural Sciences, and whose mean age 21.8 years. The statistics program SPSS/PC + of SPSS Inc. was used to analyze answers of participants. Crosstabulation, Chi-square test, and Kendall test were done. The conclusions are as follows: First, Korean youths have a tendency to prefer the slightly convex face to the flat or concave face. Second, they prefer a moderately deep nasion. Third, they prefer a moderately deep mentolabial sulcus. Fourth, they prefer the position of lips which are near to Ricketts' E-line. The position of the upper lip which is slightly posterior to E-line is preferred. The upper lip which lies too far anterior or posterior to the lower lip is not perferred. Fifth, they prefer most, according to Angle's Classification of Malocclusion, Class I facial profile which has a slight inclination to Class II division 2. The order of preference is Class I, Class II division 2, Class III, and Class II division 1. Sixth, they prefer the type 2 and 3 of Song's tangents. The facial profile within which A-and B-tangent meet is preferred. The facial profile which has Cotangent that .meets with A-tangent slightly posterior to the crossing point of A-and B-tangent or that parallels with B-tangent is preferred.

  • PDF

The effect of mandibular position and gantry angle on the evaluation of implant site with implant CT (임플랜트 전산화단층사진에서 하악의 위치와 gantry각의 변화가 임플랜트 매식로 평가에 미치는 영향에 관한 연구)

  • Lee Sul-Mi;An Chang-Hyeon;Choi Hang-Moon;Heo Min-Suk;Lee Sam-Sun;Choi Soon-Chul;Park Tae-Won
    • Imaging Science in Dentistry
    • /
    • v.32 no.1
    • /
    • pp.35-39
    • /
    • 2002
  • Purpose: The altered gantry angle during scanning for some multiplanar reconstruction CT program (CT/MPR) may cause distortion of the image. The aim of this study was to ascertain whether there is a image distortion in a reformatted image when the gantry and the object are equally inclined using ToothPix and DentaScan program. Materials and Methods: A resin block model with four cylindrical holes and a human dry mandible were used. Two MPR software packages, ToothPix and DentaScan program, were used for reformatted panoramic images. The block and the gantry were equally inclined at 0°, 15°, and 30°. Results: With ToothPix program, a resin block model with empty holes and a dry mandible showed inclined images in the reformatted panoramic image. Increasing the gantry angle, the depth and inclination of the holes were increased in the reformatted central panoramic images. However, a resin block model with gutta perch a in its holes and a dry mandible with a wire in its mandibular canal didn't show image distortion. With DentaScan program, image distortion was not seen in any situation. Conclusion: ToothPix program may distort the reformatted image when the gantry angle is not at zero degrees. However, with DentaScan program, the patient may be positioned comfortably and the gantry can be adjusted to the patient positioning.

  • PDF

Finite Element Stress Analysis on the Supporting Tissues depending upon the Position of Osseointegrated Implants Supporting Fixed Bridges (고정성 보철물을 지지하는 골유착성 임플란트의 위치에 따른 지지조직에서의 유한요소적 응력분석)

  • Yoon, Dong-Joo;Shin, Sang-Wan;Suh, Kyu-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.1
    • /
    • pp.87-99
    • /
    • 1993
  • Many studies have been reported on the successful replacement of missing teeth with osseointegrated dental Implants. However, little research has been carried out on the bio-mechanical aspect of the stress on the surrounding bone of the free-standing type of dental implant prostheses. This experimental study was aimed to analyze the stress distribution pattern on the supporting tissues depending upon the position of osseointegrated implants supporting fixed bridges. In the cases of unilateral partially edentulous mandible (the 2nd premolar and the 1st and 2nd molars missing), two osseointegrated implants were placed at the 2nd premolar and 2nd molar sites (Model A) , the 1st and 2nd molar sites (Model B, Anterior cantilevered type), the 2nd premolar and 1st molar sites (Model C, Posterior cantilevered type). Chewing forces of dentate patients and denture wearer were applied vertically on the 2nd premolar, the 1st molar, and the 2nd molar of each model. A 3-Unit fixed partial denture was constructed at each model and cantilevered extension parts were involved in Model B and Model C. Two dimensional finite element analysis was undertaken. The commercial software (Super SAP) for IBM 16 bit personal computer was utilized. The results were as follows : 1. The magnitude of applied load influenced on the total value of stresses, but did not in-fluence on the pattern of stress distribution. 2. The magnitude of stress developed from the supporting tissues were in order of Model C,Model A,Model B. 3. High stresses were concentrated on the cervical and apical portion of the implant/bone interface. 4. A difference of the stress magnitude on the implant/bone interface between mesial and distal implant was most prominant in Model C and in order of Model A and Model B. 5. The stresses developed in Model A were evenly distributed throughout both implants. 6. The stresses concentrated on the cervical portion of cantilevered side were higher in the posterior cantilevered type than in the anterior cantilevered type.

  • PDF

A STUDY ON GEOMETRIC COMPARISON OF FOUR INTERCHANGEABLE IMPLANT PROSTHETIC RETAINING SCREWS AND MEASUREMENT OF LOOSENING TORGUE (호환 가능한 임플랜트 보철용 유지 나사들의 형태 비교와 풀림 회전력의 측정에 관한 연구)

  • Cho, Su-Mi;Lim, Ju-Hwan;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.3
    • /
    • pp.468-482
    • /
    • 1998
  • Since the concept of osseointegration was introduced by Branemark of Sweden, dental implants have been used for various dental prosthetic treatments. The survival rate of dental implant is likely to be closely related to the total biomechanical role of each component of implant system. The use of interchangeable component is very attractive for dental practitioners because such an approach would save treatment cost, flexibility of prosthetic treatment options as well as conveniences. Therefore, the use of interchangeable implant system has been increasing without scientific assessment of safety and efficacy of various interchangeable implant system. The purpose of this study, therefore, were to compare the geometric characteristic of four interchangeable dental implant screws and the loosening torque of these screws. Four types of dental implant screws tested in this study were Nobelpharma, 3i, Impla-med, Restore. Four screws each of the test specimens were subjected for scanning electron microscopic examinations under the same condition and a 35x magnified standard SEM picture was objected from each test specimen using JSM-5200 scanning microscope. From each of the SEM pictures, eight parameters. i.e., diameter of screw head. screw length, thread pitch, major diameter. neck diameter, neck length, crest width and root width were determined using a caliper. The measurement for each parameters were then corrected for their magnification factor. The loosening torque were also determined by using a torque gauge. All of the measurements were statistically analyzed by ANOVA test and multiple range test. Statistical significance was set in advance at the probability level of less than 0.05. All analyses were done with SPSS software for the personal computer. The conclusion obtained from this studies were summarized as the following; 1. No statistically significances were noted in the thread pitch. and crest width in the four screws, and in the case of major diameter, the Impla-med screw was significantly smaller than the other three screws (p<0.05). Therefore, four implant bolts could be physically inserted in a abutment nuts. 2. The diameter of screw head was decreased in the order of Restore, 3i, Nobelpharma, Impla-med screws and the length of screws were decreased in the order of 3i, Restore, Nobelpharma and Impla-med. The diameter of neck was decreased in the order of Impla-med, Restore. Nobelpharma, 3i screws. The differences of each of these parameters were statistically significant (p<0.05). The width of root of screws were decreased in the order of Nobelpharma, Impla-med, Restore and 3i. The differences among Nobelpharma and Impla-med. Restore and 3i were statistically significant (p<0.05). 3. When the screws were loosening 1, 3, 4 and 5 times, the loosening torque for Impla-med and 3i screws were significantly higher than that of Nobelpharma or Restore screws (p<0.05). However, when statistically smaller than that of 3i, Restore or Nobelpharma screws(p<0.05).

  • PDF

Comparison of the outcomes of three-dimensional finite element analysis under arbitrary and realistic occlusal loading conditions in mandibular posterior region (하악 구치부에서 임의로 부여된 교합과 실제 교합의 삼차원 유한요소해석결과의 비교)

  • Lee, Wonsup;Alom, Ghaith;Kim, Myung-Soo;Park, Young-Seok;Lim, Young-Jun;Kim, Myung-Joo;Kwon, Ho-Beom
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.2
    • /
    • pp.112-120
    • /
    • 2020
  • Purpose: The purpose of this study was to compare the biomechanical outcome in the mandibular posterior region between two different loading conditions by finite element analysis. Materials and Methods: The mandibular posterior teeth model and the implant model were generated for the study. And 2 different types of loading conditions were provided: Arbitrary occlusion and natural occlusion obtained from the digital occlusal analyzer, Accura (Accura, Dmetec Co. Ltd., Seoul, Korea). Total load of 100 N was evenly distributed over arbitrary occlusion points, and 100 N load was differentially distributed over natural occlusion points according to Accura data. The biomechanical outcome was evaluated by the finite element analysis software. Results: The result of finite element analysis showed considerable difference in both von Mises stress pattern and displacement under different loading conditions. Conclusion: In finite element analysis, it is recommended to simulate a realistic occlusal loading pattern that is based on accurate measurement.

A Study on Parallel Performance Optimization Method for Acceleration of High Resolution SAR Image Processing (고해상도 SAR 영상처리 고속화를 위한 병렬 성능 최적화 기법 연구)

  • Lee, Kyu Beom;Kim, Gyu Bin;An, Sol Bo Reum;Cho, Jin Yeon;Lim, Byoung-Gyun;Kim, Dong-Hyun;Kim, Jeong Ho
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.6
    • /
    • pp.503-512
    • /
    • 2018
  • SAR(Synthetic Aperture Radar) is a technology to acquire images by processing signals obtained from radar, and there is an increasing demand for utilization of high-resolution SAR images. In this paper, for high-speed processing of high-resolution SAR image data, a study for SAR image processing algorithms to achieve optimal performance in multi-core based computer architecture is performed. The performance deterioration due to a large amount of input/output data for high resolution images is reduced by maximizing the memory utilization, and the parallelization ratio of the code is increased by using dynamic scheduling and nested parallelism of OpenMP. As a result, not only the total computation time is reduced, but also the upper bound of parallel performance is increased and the actual parallel performance on a multi-core system with 10 cores is improved by more than 8 times. The result of this study is expected to be used effectively in the development of high-resolution SAR image processing software for multi-core systems with large memory.

Implementation of Rule Management System for Validating Spatial Object Integrity (공간 객체 무결성 검증을 위한 규칙 관리 시스템의 구현)

  • Go, Goeng-Uk;Yu, Sang-Bong;Kim, Gi-Chang;Cha, Sang-Gyun
    • Journal of KIISE:Software and Applications
    • /
    • v.26 no.12
    • /
    • pp.1393-1403
    • /
    • 1999
  • 공간 데이타베이스 시스템을 통하여 공유되는 공간 데이타는 무결성이 적절하게 유지되지 않는 한 전체 응용 시스템의 행위를 예측할 수 없게 되므로 데이타의 무결성 확인 및 유지는 필수적이다. 특히 공공 GIS에 저장된 공간 데이타는 토지 이용도 평가, 도시 계획, 자원 관리, 시설물 관리, 안전 관리, 국방 등 국가 전체 및 지역의 중요한 정책 결정을 위한 다양한 응용 시스템들에 의해 이용되므로 적절한 공간 객체의 무결성 확인이 더욱 더 필요하다. 본 논문에서는 능동(active) DBMS의 능동 규칙(active rule) 기법을 이용하여 공간 객체의 무결성 확인을 지원하기 위한 규칙 관리 시스템을 제시한다. 능동 규칙을 이용한 공간 객체의 무결성 확인은 응용 프로그래머를 무결성 확인에 대한 부담으로부터 자유롭게 할 수 있다. 본 시스템은 특정 DBMS에 종속되지 않는 독립적인 외부 시스템으로 존재하며, 능동 규칙 관리기, 규칙 베이스, 그리고 활성규칙 생성기의 3 부분으로 구성된다. 사용자가 공간 데이타베이스 응용 프로그램을 통해 공간 객체를 조작하고자 할 때, 본 시스템은 데이타베이스 트랜잭션을 단위로 조작되는 모든 공간 객체의 무결성 확인을 위해 응용 프로그램에 삽입될 무결성 제약조건 규칙들을 효율적으로 관리하는 역할을 한다.Abstract It is necessary that the integrity of spatial data shared through the spatial database system is validated and appropriately maintained, otherwise the activity of whole application system is unpredictable. Specially, the integrity of spatial data stored in public GIS has to be validated, because those data are used by various applications which make a decision on an important policy of the region and/or whole nation such as evaluation of land use, city planning, resource management, facility management, risk management/safety supervision, national defense. In this paper, we propose rule management system to support validating the integrity of spatial object, using the technique of active rule technique from active DBMS. Validating data integrity using active rules allows database application programmer to be free from a burden on validation of the data integrity. This system is an independent, external system that is not subject to specific DBMS and consists of three parts, which are the active rule manager, the rule base, and the triggered rule generator. When an user tries to manipulate spatial objects through a spatial database application program, this system serves to efficiently manage integrity rules to be inserted into the application program to validate the integrity constraints of all the spatial objects manipulated by database transactions.

Development of an Verification System for Enhancing BIM Design Base on Usability (활용성을 고려한 BIM 설계 오류 검증시스템 개발)

  • Yang, Dong-Suk
    • Land and Housing Review
    • /
    • v.8 no.1
    • /
    • pp.23-29
    • /
    • 2017
  • The BIM design is expected to expand to the domestic and overseas construction industries, depending on the effect of construction productivity and quality improvement. However, with the obligation of Public Procurement Service to design the BIM design, it includes a design error and the problem of utilization of 3D design by choosing a simple 2D to 3D remodelling method that can not be modelled in 3D modeling or use of the construction and maintenance phases. The results reviewed by BIM design results were largely underutilized and were not even performed with the verification of the error. In order to resolve this, one must develop the check system that secures the quality of BIM design and ensure that the reliability of BIM results are available. In this study, it is designed to develop a program that can automatically verify the design of the BIM design results such as violation of the rules of the BIM design, design flaws, and improve the usability of the BIM design. In particular, this programs were developed not only to identify programmes that were not commercially available, but also to validate drawings in low-light computer environments. The developed program(LH-BIM) store the information of attribute extracted from the Revit file(ArchiCAD, IFC file included) in the integrated DB. This provides the ability to freely lookup the features and properties of drawings delivered exclusively by the LH-BIM Program without using the Revit tools. By doing so, it was possible to resolve the difficulties of using traditional commercial programs and to ensure that they operate only with traditional PC performance. Further, the results of the various BIM software can be readily validated, which can be solved the conversion process error of IFC in the case of SMC. Additionally, the developed program has the ability to automatically check the error and design criteria of the drawings, as well as the ability to calculate the area estimation. These functions allow businesses to apply simple and easy tasks to operate tasks of BIM modelling. The developed system(LH-BIM) carried out a verification test by reviewing the review of the BIM Design model of the Korea Land & Housing Corporation. It is hoped that the verification system will not only be able to achieve the Quality of BIM design, but also contribute to the expansion of BIM and future construction BIM.

IDENTIFICATION OF FUSOBACTERIUM NUCLEATUM AND FUSOBACTERIUM NECROPHORUM USING POLYMERASE CHAIN REACTION(PCR) (중합효소연쇄반응(Polymerase Chain Reaction)을 이용한 Fusobacterium nucleatum 및 Fusobacterium necrophorum의 동점에 관한 연구)

  • Kang, Chang-Woo;Park, Dong-Sung;Yoon, Soo-Han
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.1
    • /
    • pp.40-48
    • /
    • 1999
  • This study was designed to examine the specificities of the designed primers for F. nucleatum and F. necrophorum and to compare the PCR results using clinical samples with those of the anaerobic culture method. F. nucleatum and F. necrophorum spp. are frequently isolated in infected root canals, and they are related to periapical diseases. F. nucleatum(VPI 10197) and F. necrophorum(ATCC 25286) were used as references for PCR reaction, and thirty five teeth with one canal and periapical lesion were used. The samples were cultured anaerobically and identified using Rapid ID 32A(BioMerieux Vitek, Inc., France) as biochemical battery. In the GenBank database, species-specific PCR primers(nuc1/nuc2 primers for F. nucleatum and nec1/nec2 primers for F. necrophorum) were designed from the 16S ribosomal DNA(rDNA) sequences of F. nucleatum(accession number M58683) and F. necrophorum(accession number AF044948). PCR procedures of F. nucleatum(VPI 10197) and F. necrophorum (ATCC 25286) were simulated on a computer software. Amplify(v.1.2${\beta}$ for Macintosh). 820 bps and 817 bps of nucleotides were expected, respectively. Using extracted DNAs with QiaAmp tissue kit(Qiagen co., Germany), PCR was done. The results were as follows : 1. The nuc1/nuc2 primers produced an amplicon of 820 bps and the nec1/nec2 primers produced an amplicon of 817 bps. 2. The nuc1/nuc2 primers and the nec1/nec2 primers were specific and did not react with species other than the designated ones(i.e. nuc1/nuc2 primers did not produce amplicons for F. necrophorum, and vice versa.). And the PCR products of Porphyromonas endodontalis(ATCC 35406), Porphyromonas gingivalis(ATCC 33277), Prevotella intermedia(ATCC 25611), and Prevotella nigrescens(ATCC 33563), frequently isolated in infected root canals and periapical lesions, were not amplified by the primers specific for Fusobacterium nucleatum and Fusobacterium necrophorum. 3. This method utilizing PCR could detect F. nucleatum and F. necrophorum in clinical samples, while anaerobic culture method could detect neither.

  • PDF