• Title/Summary/Keyword: Compensation topology

Search Result 58, Processing Time 0.021 seconds

Loss Analysis of Inductive Power Transfer System considering Output Voltage Variation based on LCC-S Compensation Topology (LCC-S 공진 방식을 갖는 무선 충전 시스템의 출력전압에 따른 손실분석 연구)

  • Jo, Cheol-Hee;Kim, Seung-Min;Seol, Dae-Jung;Kim, Dong-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2020.08a
    • /
    • pp.190-192
    • /
    • 2020
  • 본 논문은 LCC-S 보상회로를 적용한 무선충전시스템의 출력전압 크기에 따른 송신부와 수신부 시스템의 손실을 비교하여 출력전압 설계 기준을 제시한다. 출력전압에 따라 풀 브리지 인버터와 송수신 PAD 및 보상회로, 정류기의 손실을 분석한다. 출력전압에 따른 송수신 시스템의 손실을 비교하여 LCC-S 공진 방식을 적용한 무선충전 시스템의 출력전압을 설계하는 기준을 제시한다. 출력전압에 따른 3.3kW 급 프로토타입을 제작하여 실험을 통해 제안된 분석의 타당성을 검증한다.

  • PDF

Wireless Power Transfer for Electric Vehicles Charging Based on Hybrid Topology Switching With a Single Inverter

  • Chen, Yafei;Zhang, Hailong;Kim, Dong-Hee;Park, Sung-Jun;Park, Seong-Mi
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.2_1
    • /
    • pp.115-124
    • /
    • 2020
  • In wireless power transfer (WPT) system, the conventional compensation topologies only can provide a constant current (CC) or constant voltage (CV) output under their resonant conditions. It is difficult to meet the CC and CV hybrid charging requirements without any other schemes. In this study, a switching hybrid topology (SHT) is proposed for CC and CV electric vehicle (EV) battery charging. By utilizing an additional capacitor and two AC switches (ACSs), a double-side LCC (DS-LCC) and an inductor and double capacitors-series (LCC-S) topologies are combined. According to the specified CC and CV charging profile, the CC and CV charging modes can be flexibly converted by the two additional ACSs. In addition, zero phase angle (ZPA) also can be achieved in both charging modes. In this method, because the operating frequency is fixed, without using PWM control, and only a small number of devices are added, it has the benefits of low-cost, easy-controllability and high efficiency. A 3.3-kW experimental prototype is configured to verify the proposed switching hybrid charger. The maximum DC efficiencies (at 3.3-kW) of the proposed SHT is 92.58%.

Development of DC-DC Converter for Ancillary Power Supply in Hybrid Electric Vehicle (하이브리드 자동차 보조전원 공급용 DC-DC 컨버터 개발)

  • Kim, Jong-Cheol;Choi, Deok-Kwan;Park, Hae-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.261-265
    • /
    • 2005
  • This paper describes the DC-DC Converter for Ancillary Power Supply in Hybrid Electric Vehicle. DC-DC Converter is used for charging 12V auxiliary battery supplying electric power to head ramp, audio, ECU etc in automobiles. used DC-DC Converter Topology is PS-ZVS FB(Phase Shifted Zero Voltage Switching Full-Bridge) to reduce switching loss and EMI noise induced by high frequency operating condition. And For easy compensation and stable system response characteristic, current mode control method including slope compensation is employed. Constant current / constant voltage charging control method guarantee stable electric charging of auxiliary battery. Simulation toll PSIM6.0 is used for initial circuit parameter settings and H/W debuging. Thermal problems of Switching components in DC-DC Converter is improved by using Thermo Tracer.

  • PDF

Eliminating the Third Harmonic Effect for Six Phase Permanent Magnet Synchronous Generators in One Phase Open Mode

  • Liu, Jian;Yang, Gui-Jie;Li, Yong;Gao, Hong-Wei;Su, Jian-Yong
    • Journal of Power Electronics
    • /
    • v.14 no.1
    • /
    • pp.92-104
    • /
    • 2014
  • To insure stable operation and eliminate twice torque ripple, a topology for a six phase permanent magnet synchronous generator (SP-PMSG) with a neutral point connected together was analyzed in this paper. By adopting an extended transformation matrix, the mathematic model of the space vector control was established. The voltage and torque equations were deduced while considering the third harmonic flux and inductance. In addition, the suppression third harmonic method and the closed loop control strategy were proposed. A comparison analysis indicates that the cooper loss minimum method and the current magnitude minimum method can meet different application requirements. The voltage compensation amount for each of the methods was deduced which also takes into account the third harmonic effect. A simulation and experimental result comparison validates the consistency through theoretical derivation. It can be seen that all of the two control strategies can meet the requirements of post-fault.

Identification on the Three-Dimensional Vortical Structures of Impeller Flow by a Multi-Plane Stereoscopic PIV Method (스테레오 PIV 기법에 의한 임펠러 와류유동의 3차원 구조측정)

  • Yoon, Sang-Youl;Kim, Kyung-Chun
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.690-695
    • /
    • 2001
  • The three-dimensional spatial structures of impeller flow created by a six bladed Rushton turbine have identified based on the volumetric velocity information from multi-plane stereoscopic PIV measurements. A total of 10 planes with 2 mm space with a 50 mm by 64 mm size of the field of view were targeted. To reduce the depth of focus, we adopted an angle offset configuration which satisfied the Scheimpflug condition. The distortion compensation procedure was utilized during the in situ calibration. Phase-locked instantaneous data were ensemble averaged and interpolated in order to obtain mean 3-D, volumetric velocity fields on a 60 degree sector of a cylindrical ring volume enclosing the turbine blade. Using the equi-vorticity surface rendering, the spatial structure of the trailing vortices was clearly demonstrated. Detail flow characteristics of the radial jet reported in previous studies of mixer flows were easily identified.

  • PDF

Enhanced Controller Topology for Photovoltaic Sourced Grid Connected Inverters under Unbalanced Nonlinear Loading

  • Sivakumar, P.;Arutchelvi, Meenakshi Sundaram
    • Journal of Power Electronics
    • /
    • v.14 no.2
    • /
    • pp.369-382
    • /
    • 2014
  • A growing dynamic electrical demand has created an increasing interest in utilizing nonconventional energy sources like Photovoltaic (PV), wind power, etc. In this context, this paper focuses on the design and development of a composite power controller (CPC) in the decoupled double synchronous reference frame (DDSRF) combining the advantages of direct power control (DPC) and voltage oriented control (VOC) for a PV sourced grid connected inverter. In addition, a controller with the inherent active filter configuration is tested with nonlinear and unbalanced loads at the point of common coupling in both grid connected and autonomous modes of operation. Furthermore, the loss and reactive power compensation due to a non-fundamental component is also incorporated in the design, and the developed DDSRF model subsequently allows independent active and reactive power control. The proposed developed model of the controller is also implemented using MATLAB-Simulink-ISE and a Xilinx system generator which evaluate both the simulated and experimental setups. The simulation and experimental results confirm the validity of the developed model. Further, simulation results for the DPC are also presented and compared with the proposed CPC to further bring out the salient features of the proposed work.

Single-Tuned Active Filter with Function of Double-Tuned Active Filter (Double Tuned Active Filter 기능을 갖는 Single Tuned Active Filter)

  • Kim Chan-Ki;Yang Byeong-Mo;Jung Gil-Jo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.6
    • /
    • pp.544-552
    • /
    • 2004
  • This paper deals with the hybrid active filter which can reduce the 11th/13th harmonics in AC network by using the single tuned filter. Since the proposed algorithm uses the detuning compensation capability of the filter, the output voltage of the proposed active power filter is changed according to the capacitance of capacitors, magnitude of harmonic current, resonance frequency and control mode. In this paper, the control characteristics and the design of hybrid active filter is investigated. A new hybrid active filter with new algorithm, which is an active filter with single tuned filter instead of double tuned filter, is proposed.

The Study of 3-Phase Bi-Directional DC to AC Inverter for the Bi-Model PV PCS (자립형 태양광 발전 시스템을 위한 3상 양방향 DC-AC 인버터 연구)

  • Yang, Seung-Dae;Jung, Seung-Hwan;Choi, Ju-Yeop;Choy, Ick;Lee, Young-Kwon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.319-324
    • /
    • 2012
  • This paper presents the study of 3-Phase bi-directional DC to AC inverter with unity power factor. 3-Phase bi-directional DC to AC inverter is important for the bi-modal PV PCS with an energy storage system. Both Inverting and converting are needed to connect between the grid side and boost converting side to charge and discharge the energy storage system. The paper proposes the appropriate circuit topology and proper control system for the bi-directional inverter. It also proposes the method of selecting the optimum control method considering system stability. PSIM simulation is used to validate the proposed algorithm.

  • PDF

A Cost-Effective, Single-Phase Line-Interactive UPS System that Eliminates Inrush Current Phenomenon for Transformer-Coupled Loads

  • Bukhari, Syed Sabir Hussain;Atiq, Shahid;Lipo, Thomas A.;Kwon, Byung-il
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.3
    • /
    • pp.675-682
    • /
    • 2016
  • Sudden voltage drops and outages frequently disturb the operation of sensitive loads for domestic, commercial, and industrial use. In some cases, these events may even impair the functioning of relevant equipment. To maintain power under such conditions, a UPS system is usually installed. Once a disturbance happens at the grid side, the line-interactive UPS system takes over the load to prevent an interruption. But, due to magnetic saturation of the transformer, a significant inrush current may occur for the transformer-coupled loads during this transition. The generation of such transient currents may in turn decrease the line voltage and activates over-current protecting devices of the system. In this work, a cost-effective, line-interactive UPS system is proposed that eliminates the inrush current phenomenon associated with transformer-coupled loads. The strategy was implemented by connecting a standard current-regulated voltage source inverter (CRVSI) to the secondary winding of the load transformer. During any transient condition at the grid side, the load current is monitored and regulated to achieve either seamless compensation of the load current or complete transferal of load from grid to the inverter. Experimental results were obtained for a prototype under all possible operating conditions so as to validate the performance of the proposed topology.

Identification on the Three-Dimensional Vortical Structures of Impeller Flow by a Multi-Plane Stereoscopic PIV Method (스테레오 PIV 기법에 의한 임펠러 와류유동의 3차원 구조측정)

  • Yoon, Sang-Youl;Kim, Kyung-Chun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.6
    • /
    • pp.773-780
    • /
    • 2003
  • The three-dimensional spatial structures of impeller flow created by a six bladed Rushton turbine have identified based on the volumetric velocity information from multi-plane stereoscopic PIV measurements. A total of 10 planes with 2 mm space and a 50 mm by 64 mm size of the field of view were targeted. To reduce the depth of focus, we adopted an angle offset configuration which satisfied the Scheimpflug condition. The distortion compensation procedure was utilized during the in situ calibration. Phase-locked instantaneous data were ensemble averaged and interpolated in order to obtain mean 3-D. volumetric velocity fields on a 60 degree sector of a cylindrical ring volume enclosing the turbine blade. Using the equi-vorticity surface rendering, the spatial structure of the trailing vortices was clearly demonstrated. Detail flow characteristics of the radial jet reported in previous studies of mixer flows were easily identified.