• 제목/요약/키워드: Compensation Controller

검색결과 750건 처리시간 0.025초

퍼지제어를 이용한 마이크로 로보트 핑거의 힘제어 (Force Control of Micro Robotic Finger Using Fuzzy Controller)

  • 류재춘;박종국
    • 한국지능시스템학회논문지
    • /
    • 제7권5호
    • /
    • pp.67-76
    • /
    • 1997
  • In this paper, a theoretical study is presented for the force control of a miniature robotic manipulator which is driven by a pair of piezo-electric bimorph cells. In the theoretical analysis, one finger is modeled as a flexible cantilevers with a force sensor at the tip and the finger is a solid beam. The robotic finger is used to hold the objects with different stiffness such as an iron block and a living insect and a moving objcet. So it is very important to develop an adequate controller for the holding operation of the finger. The main problems in force controlling are overdamping, overshoot and unknown environment(such as the stiffness of object and unknown plant parameters). So, the main target is propose the new fuzzy compensation for unknown environment and incease the system performance. The fuzzy compensation is implemented by using PI-type fuzzy approach to identified unknown environment. And the result of proposed controller was compared with the conventaional PID and optimal controller.

  • PDF

Adaptive DC-link Voltage Control for Shunt Active Power Filter

  • Wang, Yu;Xie, Yun-Xiang
    • Journal of Power Electronics
    • /
    • 제14권4호
    • /
    • pp.764-777
    • /
    • 2014
  • This study analyzes the mathematical relationship between DC-link voltage and system parameters for shunt active power filters (APFs). Analysis and mathematical deduction are used to determine the required minimum DC-link voltage for APF. A novel adaptive DC-link voltage controller for the three-phase four-wire shunt APF is then proposed. In this controller, the DC-link voltage reference value will be maintained at the required minimum voltage level. Therefore, power consumption and switching loss will effectively decrease. The DC-link voltage can also adaptively yield different DC-link voltage levels based on different harmonic currents and grid voltage levels and thus avoid the effects of harmonic current and grid voltage fluctuation on compensation performance. Finally, representative simulation and experimental results in a three-phase four-wire center-split shunt APF are presented to verify the validity and effectiveness of the minimum DC-link voltage design and the proposed adaptive DC-link voltage controller.

Compensation for temperature-level control of tanked water system with time delay

  • Nakamura, Masatoshi;Watanabe, Kiyoto
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1993년도 한국자동제어학술회의논문집(국제학술편); Seoul National University, Seoul; 20-22 Oct. 1993
    • /
    • pp.42-47
    • /
    • 1993
  • Importance of separation of a nonlinear dynamical system into nonlinear static part and linear dynamical part was insisted in designing a controller for the nonlinear system. We further proposed compensation techniques for oscillation of controlled variables caused by system time delay and compensation of steady state errors caused by modelling errors of the systems. The proposed principle of designing procedure and the compensation methods were discussed by applying them for temperature and level control of an actual tanked water system.

  • PDF

CRT 프로젝션 TV에서의 Convergence 보정 알고리즘 (A Convergence Compensation Algorithm for A CRT Projection TV)

  • 강석판;정창기;최두현
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 신호처리소사이어티 추계학술대회 논문집
    • /
    • pp.355-358
    • /
    • 2003
  • Basically, the mis-convergence, which is inevitable in CRT Projection TV. is the degree of deviation of red and blue from green beam. The cause of mis-convergence is the change of magnetic field and electrical characteristic in deflection circuits and convergence amplification circuit. A new and easily implementable mis-convergence compensation algorithm is presented in this paper. The proposed algorithm does not needs any compensation devices. It uses only TV OSD and a remote controller and anyone who wants to compensate can easily correct the mismatch. Through real compensation experiments, it is found that the proposed algorithm is useful and effective one.

  • PDF

Design of a High-Precision Constant Current AC-DC Converter with Inductance Compensation

  • Chang, Changyuan;Xu, Yang;Bian, Bin;Chen, Yao;Hu, Junjie
    • Journal of Power Electronics
    • /
    • 제16권3호
    • /
    • pp.840-848
    • /
    • 2016
  • A primary-side regulation AC-DC converter operating in the PFM (Pulse Frequency Modulation) mode with a high precision output current is designed, which applies a novel inductance compensation technique to improve the precision of the output current, which reduces the bad impact of the large tolerance of the transformer primary side inductance in the same batch. In this paper, the output current is regulated by the OSC charging current, which is controlled by a CC (constant current) controller. Meanwhile, for different primary inductors, the inductance compensation module adjusts the OSC charging current finely to improve the accuracy of the output current. The operation principle and design of the CC controller and the inductance compensation module are analyzed and illustrated herein. The control chip is implemented based on a TSMC 0.35μm 5V/40V BCD process, and a 12V/1.1A prototype has been built to verify the proposed control method. The deviation of the output current is within ±3% and the variation of the output current is less than 1% when the inductances of the primary windings vary by 10%.

퍼지마찰력보상기를 이용한 정밀위치제어에 관한 연구 (A Study on Pricision Positioning Control using a Fuzzy Friction Compensation)

  • 윤승환;양상식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 B
    • /
    • pp.1045-1049
    • /
    • 1996
  • For the precision positioning and tracking control, the proper friction compensation is essential. The friction causes steady state error. The friction compensation based on the velocity and the controlling input or the desired velocity provides limited performance if the compensation value is fixed. In this paper, a friction compensation scheme using a fuzzy logic is proposed. The friction compensation amount is adjusted depending on the velocity and controlling input. The proposed fuzzy friction compensator with a pole-assignment controller is implemented in a linear positioning system. To illustrate the effectiveness of this scheme, computer simulations and experiments are carried out for the cases of no friction compensation, the proposed fuzzy friction compensation, and another friction compensation scheme based on velocity and control input, and the results are compared with each other.

  • PDF

퍼지제어기를 이용한 로보트 액츄에이터용 초음파 모터의 온도 보상에 관한 연구 (The Study on the Temperature Compensation of Ultrasonic Motor for Robot Actuator Using Fuzzy Controller)

  • 차인수;유권종;백형래;김영동
    • 전력전자학회논문지
    • /
    • 제3권3호
    • /
    • pp.165-172
    • /
    • 1998
  • USM의 전기 기계적인 변환은 USM의 고정자에 정렬된 PZT트랜듀서를 구동하기 위한 2-상 고주파 전력 변환부와 고정자와 회전자 사이에 마찰력을 변환하는 기계적인 트러로써 나눠지며 이러한 구조특성 때문에 온도에 의한 비선형 특성이 내포하게 된다. 초음파 모터의 외함의 온도가 +2$0^{\circ}C$~3$0^{\circ}C$에서는 정상적인 특성을 나타내지만 장시간의 운전에 의한 모터의 마찰열에 의해 온도증가는 구동주파수, 구동전류, 속도의 감소를 가져온다. 현재 사용되고 있는 초음파 모터는 온도에 대한 보상이 이뤄지지 않고 있다. 본 논문에서는 퍼지제어 기법을 통해 초음파 모터의 운전중 외함의 온도증가에 따른 속도 보상용 시스템을 제안한다.

PMSM에 대한 활성화 함수를 가지는 토크 보상기의 속도제어 (A Speed Control Scheme with The Torque Compensator based on the Activation Function for PMSM)

  • 김홍민;임근민;안진우;이동희
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 추계학술대회
    • /
    • pp.315-316
    • /
    • 2011
  • This paper presents speed control scheme of the PMSM which has torque compensator to reduce the speed error and ripple. The proposed speed controller is based on the conventional PI control scheme. But the additional torque compensator which is different to the conventional differential controller produces a compensation torque to suppress speed ripple. In order to determine the proper compensation, the activation function which has discrete value is used in the proposed control scheme. With the proposed activation function, the compensation torque acts to suppress the speed error increasing. The proposed speed control scheme is verified by the computer simulation and experiments of 400[W] PMSM. In the simulation and experiments, the proposed control scheme has better control performance compare than the conventional PI and PID control schemes.

  • PDF

PMLSM의 추력 리플 저감을 위한 DSP기반 디지털 제어기의 설계 (Design of Digital Controller Based DSP for Thrust Ripples Suppression of PMLSM)

  • 진상민;주옥오;김도선;조윤현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.140-142
    • /
    • 2008
  • Thrust ripples in Permanent Magnet Linear Motor(PMLSM) are mainly generated by cogging force. Cogging force caused by the interaction between the iron core and the Permanent Magnet(PM), and end effect. This paper has proposed a control method for thrust ripples suppression and design of one-chip proceeding digital controller using TMS320LF2407. This control method is realized by Field Oriented Control(FOC) adding to current compensation. The effectiveness of proposed control method is verified by experimentation comparing between the compensation and non-compensation.

  • PDF

고조파 전류 제거를 위한 새로운 전류 보상 기법 (Novel Current Compensation Technique for Harmonic Current Elimination)

  • 정강률
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(2)
    • /
    • pp.587-591
    • /
    • 2004
  • This paper proposes a novel current compensation technique that can eliminate the harmonic currents included in line currents without computation of harmonic current components. A current controller with fast dynamics for an active filter is described. Harmonic currents are directly controlled without the need for sensing and computing the harmonic current of the load current, thus simplifying the control system. Current compensation is done in the time domain, allowing a fast time response. The DC voltage control loop keeps the voltage across the DC capacitor constant. High power factor control by an active filter is described. All control functions are implemented in software using a single-chip microcontroller, thus simplifying the control circuit. Any current-controlled synchronous rectifier can be used as a shunt active filter through only the simple modification of the software and the addition of current sensors. It is shown through experimental results that the proposed controller gives good performance for the shunt active filter.

  • PDF