• 제목/요약/키워드: Compartment Fire Test

검색결과 50건 처리시간 0.022초

A60급 구획 적용 격벽 관통용 관의 열전달 특성 II: 관 재질 및 단열재 종류에 따른 방화시험 (Heat Transfer Characteristics of Bulkhead Penetration Piece for A60 Class Compartment II: Fire Resistance Test for Piece Material and Insulation Types)

  • 박우창;송창용
    • 한국해양공학회지
    • /
    • 제33권4호
    • /
    • pp.340-349
    • /
    • 2019
  • In the case of a fire accident on a ship or an offshore plant, the design of the bulkhead penetration piece must be verified via a fire test procedure (FTP), as specified by the Maritime Safety Committee (MSC). The purpose of this study is to verify both the numerical analysis results and the design specifications for penetration pieces that could be applied to the A60 class bulkhead division. In this study, the FTP was carried out in accordance with the test procedure prescribed in the MSC regulation. In order to review the fire resistance performance according to the material type, bulkhead penetration pieces for the FTP were made from brass, carbon steel for machine structures (S45C), and austenite stainless steel (SUS316). In addition, spray-type insulation and mechanical fastener-type insulation were applied to investigate the fire resistance performance according to the type of insulation. To verify the heat transfer numerical analysis results for the A60 class bulkhead penetrating piece from this test study, the design specifications of the penetrating piece material and the insulation type applicable to a ship and an offshore plant were identified.

구획 화재에서 스프링클러 열 손실계수 변화에 따른 작동 시간 분석 (Analysis on the Effects of the Heat Loss Coefficient on the Operation Time of Sprinkler in Compartment Fire)

  • 유우준
    • 한국화재소방학회논문지
    • /
    • 제32권5호
    • /
    • pp.34-39
    • /
    • 2018
  • 본 연구에서는 구획 공간 화재 시 발열량이 급격히 변하는 조건에서 스프링클러헤드의 손실인자 변화에 따른 작동시간을 분석하였다. 이를 위해서 내화보드로 구성된 구획 공간의 크기가 폭 0.3 m, 세로 0.5 m, 길이 3.0 m인 구조물을 제작하고 헵탄(n-Heptane) 풀 화재 실험을 수행하여 구획 공간 내부의 온도 분포, 헵탄의 질량감소율 그리고 발열량을 산출하였다. 또한, Fire Dynamics Simulator (FDS) Version 6.5를 사용하여 실험 조건과 동일한 발열량을 가정하고 스프링클러헤드의 설치위치 및 손실인자(C-factor) 변화에 따른 작동 시간을 분석하였다. 그 결과 반응시간지수(Response Time Index, RTI)가 $100(m{\cdot}s)^{0.5}$이고 작동온도가 $72^{\circ}C$인 스프링클러는 화원 상층부의 기류 온도가 $100^{\circ}C$에서 $300^{\circ}C$로 상승하고, 기류의 속도가 약 0.7 m/s인 경우 C-factor = 0과 1일 때 스프링클러의 작동시간은 최소 30 s~60 s, C-factor = 3일 때 62 s에서 최대 92 s, C-factor = 5일 때 120 s 이상으로 나타났다.

Temperature distribution in a full-scale steel framed building subject to a natural fire

  • Wald, Frantisek;Chladna, Magdalena;Moore, David;Santiago, Aldina;Lennon, Tom
    • Steel and Composite Structures
    • /
    • 제6권2호
    • /
    • pp.159-182
    • /
    • 2006
  • Current fire design codes for determining the temperature within the structural elements that form part of a complete building are based on isolated member tests subjected to the standard fire. However, the standard time-temperature response bears little relation to real fires and doesn't include the effects of differing ventilation conditions or the influence of the thermal properties of compartment linings. The degree to which temperature uniformity is present in real compartments is not addressed and direct flame impingement may also have an influence, which is not considered. It is clear that the complex thermal environmental that occurs within a real building subject to a natural fire can only be addressed using realistic full-scale tests. To study global structural and thermal behaviour, a research project was conducted on the eight storey steel frame building at the Building Research Establishment's Cardington laboratory. The fire compartment was 11 m long by 7 m wide. A fire load of $40kg/m^2$ was applied together with 100% of the permanent actions and variable permanent actions and 56% of live actions. This paper summarises the experimental programme and presents the time-temperature development in the fire compartment and in the main supporting structural elements. Comparisons are also made between the test results and the temperatures predicted by the structural fire Eurocodes.

차단막에 의한 랙크 구획화가 화재확산 저감에 미치는 영향 (Effect of Rack Compartment using Barriers on Reducing the Fire Spread)

  • 조규환;여인환
    • 한국화재소방학회논문지
    • /
    • 제32권1호
    • /
    • pp.66-75
    • /
    • 2018
  • 랙크 내 설치되는 차단막은 초기 화재확산을 지연시키는데 큰 역할을 담당하고 있으나 소화를 목적으로 설치되는 천장형 스프링클러의 입장에서는 소화수의 원활한 공급에 장애물로서 비춰질 수도 있다. 이에 In-Rack 스프링클러와 차단막을 동시에 적용하는 방법 등이 제시되고 있으나 차단막의 설치조건에 따른 화재확산 지연성능 및 In-Rack 스프링클러에 미치는 영향 등에 관한 연구는 부족한 실정이다. 이에 본 연구에서는 축소모델 화재실험을 통해 차단막의 설치조건에 따른 화재확산 지연성능과 In-Rack 스프링클러에 미치는 영향 등을 분석하였다. 그 결과, 랙크 내에 수평과 수직 차단막을 동시에 설치한 경우, 4배 이상의 화재확산 지연성능이 발휘되는 것을 확인하였으며, 구획화로 인한 구획 내 온도 상승 또한 약 2~3배 가량 높은 것으로 나타나 In-Rack 스프링클러가 조기에 작동될 수 있도록 유도하는 긍정적인 효과 또한 존재하는 것으로 나타났다.

미분무수 소화설비의 선박용 기관실 적용에 관한 연구 (A Study on the Application of Water Mist Fire Extinguishing System to Machinery Spaces)

  • 김기옥;안병호;양우진;김영한
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 후기학술대회논문집
    • /
    • pp.132-133
    • /
    • 2005
  • A study to evaluate the fire extinguishing performance of the water mist system inside simulated machinery spaces according to IMO MSC/Circ.668 was performed. Fire tests were conducted inside a compartment having a area 100$m^2$(10m${\times}$10m) with a ceiling height of 10m and door opening of 2m${\times}$2m in size. Test fuels were used heptane, diesel, wood crib and mineral oil. Water mist nozzles were installed downward at ceiling and horizontally at bilge area. All fires in the test were extinguished within 15minutes of system activation and there was no reignition or fire spread.

  • PDF

화재하중에 따른 구획화재 실험 연구 (The Study on Compartment Fire Experiment According to Fire Load)

  • 권오상;김흥열
    • 한국화재소방학회논문지
    • /
    • 제31권6호
    • /
    • pp.16-22
    • /
    • 2017
  • 국내에서는 복잡해지고 다양해지고 있는 건축물에서의 화재위험에 대응하기 위해 성능기반 화재안전 설계가 논의되고 있지만, 건축물에서의 다양한 인자들에 의한 화재특성의 에측의 어려움으로 인하여 성능기반 화재안전 설계의 도입이 제한되고 있다. 본 연구에서는 뉴질랜드에서 제시하고 있는 화재위험도별 화재하중 값의 실대형 화재실험을 통해 성능기반 설계 도입을 위한 기준 방향 설정 및 기초 자료로 사용하고자 하였다. 실대형 화재실험은 10 MW급의 실대형 칼로리미터에서 $0.8(L){\times}2.0(H)m$의 단일 개구부를 포함하고 있는 $2.4(L){\times}3.6(W){\times}2.4(H)m$ 크기의 시험체 틀의 내부에 목재 크립을 화재하중에 따라 배치시켜, 목재 크립이 전소할 때 까지 진행하였다. 화재실험에서 열방출률의 변화는 목재 크립에 화염이 착화 된 후 외부로 출화되는 약 90초 이후부터 급격히 증가하였으며, 위험도 레벨 1에서는 최대 4743.4 kW의 열발출률이 실험시작 후 244 초에 측정되었고 위험도 레벨 2에서는 5050.9 kW의 최대 열방출률이 497 초에 측정되었다. 또한 위험도 레벨 3에서는 최대 열방출률이 4446.9 kW로 실험시작 677 초에 측정되었다.

주거용 컨테이너 화재 특성에 관한 실험적 고찰 (An Experimental Study on Characteristics of the Residential Container Building Fire)

  • 이정윤;정기창;김홍
    • 한국안전학회지
    • /
    • 제23권1호
    • /
    • pp.24-27
    • /
    • 2008
  • The recent fire incident in an elementary school of Chonan city causes the media focus on the fire safety of residential container buildings. In this study, real fire tests were conducted in this kind of buildings. Fire temperature and radiant heat flux were measured, in order to investigate the hazard-reduction effects during the fire emergency of residential container buildings. According to the test results, flash over occur in 10 minutes, peak fire temperature was $935.5^{\circ}C$, peak radiant heat flux was $24.99kW/m^2$ at 8minutes after residential container building fire.

원전구조물 적용 마감재의 국내 연소시험방법 조사연구 (Study of Testing Methods for Combustible Properties of Finishing Materials Applied into Nuclear Power Plants)

  • 권인규
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 춘계 학술논문 발표대회
    • /
    • pp.60-61
    • /
    • 2018
  • Finishing materials are very important to restrain fire spread from a compartment to another in a fire situation. Therefore, the evaluation of combustible properties for the combustible material is essential to apply finishing materials into a generic buillding or s special occupancy structure. In this study, the testing methods for evaluation of combustible performance of finishing materials of domestic were surveyed in order to prepare the guideline of application of finishing materials in nulear power plant.

  • PDF

조립식 건축물의 화재특성연구 (An Experimental Investigation on Combustion Characteristics of the Knockdown Building)

  • 이정윤;김홍
    • 한국안전학회지
    • /
    • 제23권3호
    • /
    • pp.30-35
    • /
    • 2008
  • The recent fire incident in an elementary school of Chonan city causes the media focus on the fire safety of residential container buildings. In this study, real fire tests were conducted in this kind of buildings. Combustion products including $O_2$, $CO_2$, CO, $NO_x,$, $SO_x$, HCI, HCN were measured, in order to investigate the hazard-reduction effects of employing gas mask protected with filter during the fire emergency of residential container buildings. According to the test results, whether or not employing the filter showed a sheer difference in the toxicity of the fire-induced gases, and then the importance of wearing a gas mask was evidently demonstrated.

건물 내장재의 화재위험성 평가 방법 (A Fire Hazard Assessment of Interior Finish Materials)

  • 김운형
    • 한국화재소방학회논문지
    • /
    • 제12권2호
    • /
    • pp.17-28
    • /
    • 1998
  • 건물 화재시 예상되는 내장재의 실째 화재성농올 기준으로 한 위험성 명가방법올 제시하였다. 이률 위해 ISO Room Corner Test. (9705)를 기준으로 Qui ntie re의 화재확산 모델을 이용하여 내장재의 열 적 특성과 플래쉬 오버 도달시간과의 상관성을 유도하고 스쩨덴의 실제 시험결과와 비교 분석하였다. 이 결과, 내장재의 상대척인 화재위험성은 화재확산 변수 b륨 기준으로 명가될 수 있었다.

  • PDF