• 제목/요약/키워드: Common Earth

검색결과 370건 처리시간 0.029초

공동 접지망에서의 접지 저항값 시뮬레이션 및 측정 (Simulation and Measurement of Earth resistance Values in Common Earth Network)

  • 김용규;김종기;양도철;박현준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.1073-1074
    • /
    • 2006
  • In this paper, we perform a simulation to verify the earth resistance values in Common Earth Network. The simulation is performed on the assumption that certain shorts are occurred in common earth network. Furthermore, from the result, we confirmed that very small earth resistance values in common earth network are given, by carrying out practical measurements in railway sections where common earth network is composed. From the effect, we could discover that the construction of common earth network is in a disadvantageous position on the financial aspect, while it is the most desirable way of construction for the purpose of Earth.

  • PDF

궤도회로에서의 공동접지와 단독접지 인터페이스 (Interface between Common earth and Individual earth on the Track circuit)

  • 이길노;김용규;김종기;김학련
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.269-274
    • /
    • 2005
  • This paper is studied on earth network configuration when common earth is applied to electrified railway system. And the permitted capacity of buried earth cable used for configuring common earth network and application plan of existing individual earth system when common em1:h network is applied to existing electrification line improvement are studied. For this, the configuration of common earth network is examined according to the SNCF regulation, and the interface between common earth and individual earth is analysed on the basis of the existing track circuit used in electrified line.

  • PDF

$2{\times}25 kV$급전 방식에서의 공동 접지망 적용에 따른 귀선 전류의 영향 (Effects of the Common Earth Network on the Traction Return Current in $2{\times}25 kV$ Power Supply System)

  • 김용규;류창근
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제51권9호
    • /
    • pp.509-514
    • /
    • 2002
  • The aim of this research is to find out how the common earth network affects the level of the traction return current in the $2{\times}25 kV$ Power Supply System. The traction return current plays a significant role in the operation of the facilities near the rails. It is shown that the common earth network in the $2{\times}25 kV$ power supply system not only minimizes the level of the traction return current, but also increases the safety of the working crew on the railways. In order to determine the relationship between common earth network and the traction return current, we investigated the earth system of the Gyongbu High Speed Line that is constructed following the SNCF regulations. We carried out the field test in the Osong station. The results of the test show that the common earth network minimizes the effect of the traction return current. We also find that the simulated results are very similar to the test results. We concluded that the results of the test can be applied for the rest of the Gyongbu High Speed Line under construction.

고속선 귀선전류 측정값 비교 및 분석 (Comparison and Analysis of Return Current Measurement Values on High Speed Line)

  • 김용규;김주엽;오세찬;백종현;윤용기;곽우현
    • 전기학회논문지
    • /
    • 제66권5호
    • /
    • pp.877-884
    • /
    • 2017
  • A method of common earth, which is proposed by French Railway(SNCF) and is applied to high speed railway, minimizes the effect of the traction return current from tracks so that trackside electric devices can be protected and operation and maintenance staffs are kept out from injury in an electric railway environment. According to it, all the new domestic electric railway lines are replaced from existing individual earth method to the common earth method. In this paper, we analyze the correlation between common earth method and traction return current to prove whether the common earth has surely contributed to minimize the effect of the traction return current. The analysis was done based on the measurement of the traction return current at the domestic high speed railway line.

전기철도시스템의 접지 유형에 따른 귀선 전류 비교 (Comparison of Return current by the Earth type in the Electrical railway system)

  • 이길노;김용규;백종현;유창근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.53-55
    • /
    • 2005
  • In electrical railway system, power supplied to electrical locomotive by catenary is returned to sub-station on track. The current returned to sub-station on track is return current, which is an essential factor for the safety of the wayside electrical equipment and maintenance staff. Therefore, earth system acts an important role to protect wayside electrical equipment and maintenance staff against return current. In general, individual earth system protects partially the electrical railway system, but common earth system does the whole electrical railway system and minimizes the flow of return current. In this paper, we are compared the effect of return current according to earth type by actual measurement in existing electrical railway system. The measurement was conducted at Shinchungju sub~station in high speed trains, and Guro sub-station, which is electrified section in classical line.

  • PDF

낙뢰 피해 최소화를 위한 공동 접지망 구성 (Common Earth Network constitution for minimize surge damage)

  • 김용규;백종현;최경일;류근수
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.190-195
    • /
    • 2008
  • Surge proof equipment is an installation to make surge flow on the ground promptly so as to reduce surge-related damage on infrastructure, not to prevent surge from falling down on infrastructure directly. Compared with classical line individual earth, High speed line common earth has higher surge characteristic and plays a significant role to prevent infrastructure damage and injuries from surge, or short circuit accident between 25kV catenary and rail. In this paper, we analyzed the case of accident that caused communication/signaling system impaired while a tractor crossing level crossing at Honam line; in addition, we examined the accident reduction measures to minimize injury and property damage from cutting accidents with respect to common earth network.

  • PDF

혼합 배전선로에 직격낙뢰시 전주와 케이블직선접속재가 케이블 동심중성선 전위상승에 미치는 영향 (A Study of Concentric-Neutral Line Voltage Increase Related by Pole and Cable Joint When Lightening Overvoltage Injected in Combined Distribution Line)

  • 전용주;전명수
    • 전기학회논문지
    • /
    • 제67권6호
    • /
    • pp.702-707
    • /
    • 2018
  • In case of Lighting occurs in Domestic combined distribution line, normally the voltage for the neutral line increase dramatically. General connection for underground cable is bundled common earth type so the lightning over voltage increase at the concentric-neutral line is not big enough to give impact on cable sheath. But in case of Non bundled common earth type it is necessary to analyze the phenomena on cable sheath caused by lightening overvoltage. Especially pole and cable joint are the core factor to consider. In this paper concrete pole and cable joint were evaluated in case of Non bundled common earth type combined distribution Line. EMTP simulation model has been designed and several case study were made. Also several experimental test were made to verify the simulation result.

High-energy Photons and Particles in Space Environment

  • Ohno, Shin-ichi
    • Journal of Photoscience
    • /
    • 제9권2호
    • /
    • pp.170-173
    • /
    • 2002
  • Space is full of energetic events emitting high-energy radiations which may be fatal to all living things unless protected. The present paper briefly describes high-energy photons and particles incident on Earth surface and their common properties toward living things. Role of radiation played in evolution of life and earth environment will be presented.

  • PDF

송전선로 철탑기초의 접지저항 해석 (Analysis of the Earth Resistance for the Tower Footing of T/L)

  • 이현구;하태현;배정효;김대경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.344-346
    • /
    • 2001
  • The sharing of common corridors by electric power transmission lines and pipelines is becoming more common place. However, such corridor sharing can result in undesired coupling of electromagnetic energy from the power lines to the near facilities. During a fault on any of the transmission lines, energization of the earth by supporting structures near the fault can result in large voltages appearing locally between the earth and the steel wall of any nearby pipeline. This paper presents the outline of the tower footings for the transmission lines having been used in KEPCO and analyzes the earth resistance for operation method of the tower footing, that is contact presence for the anchor and reinforcing rob of the tower and foundation presence of the underground wiring.

  • PDF

경부선 전철화 구간에서의 공동접지에 의한 귀선전류 분석 (Analysis of Return Current by Common Earth on Electrical Line of the Gyeongbu Line)

  • 김용규;백종현
    • 한국산학기술학회논문지
    • /
    • 제11권12호
    • /
    • pp.4968-4974
    • /
    • 2010
  • 전기철도는 전차선을 통해 차량을 구동할 수 있는 전력을 공급하며, 공급된 전류는 선로 및 접지망을 통해 변전소로 귀환한다. 국내의 경우, 이러한 귀선전류에 영향을 주는 접지망 구성은 대부분 단독 접지방식을 사용하였으나, 경부고속선의 도입과 함께 공동 접지방식의 개념이 전기철도에 적용되었다. 본 논문에서는 고속철도의 기존선 운행을 위한 전철화 구간에서 측정, 분석한 귀선전류를 기반으로 전철화 구간에 있어서의 접지방식과 귀선전류의 관계를 분석하였다. 이러한 분석은 경부고속선 궤도회로에서 측정된 귀선전류 분석값과 경부고속선과 기존선 전철화 구간의 접지방식 비교에 따른 귀선전류의 예측값을 활용하였다.