• Title/Summary/Keyword: Combined array

Search Result 219, Processing Time 0.026 seconds

Development of a Portable Hydrophone Array System (휴대용 수중청음기 배열 시스템의 개발)

  • Kim Bong-Chae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.25 no.4
    • /
    • pp.178-183
    • /
    • 2006
  • A hydrophone away is used to measure spatial distribution in underwater sound field and to detect incoming direction of sound waves in the ocean. It is not usually convenient to handle the hydrophone away because of its extensive scale. And it is not easy to purchase the hydrophone away because of expensive price. A hydrophone logger combined with a hydrophone and data logger was developed to consist conveniently of a hydrophone away for use to receive underwater sound waves. And a hydrophone array system with the hydrophone loggers was developed. Main configurations of the hydrophone 1o99er and the hydrophone array system are introduced in this paper. Also we present some measurement results by the hydrophone logger in a water tank and measurement examples on ambient noise in the sea by the hydrophone away system. And we discuss some advantages in use of the hydrophone array system.

Occupant Analysis and Seat Design to Reduce the Neck Injury for Rear End Impact (후방추돌시 목상해를 고려한 승객거동해석 및 좌석설계)

  • 신문균;박기종;박경진
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.9
    • /
    • pp.182-194
    • /
    • 1999
  • Occupant injury in rear end impact is rapidly becoming one of the most aggravating traffic safety problems with high human suffering and societal costs. Although rear end impact occurs at relatively low speed , it may cause permanent disability due to neck injuries resulting from an abrupt moment, shear force , and tension/compression force at the occipital condyles. The analysis is performed for a combined occupant-eat model response, using the SAFE(Safety Analysis for occupant crash Environment) computer program. The computational results are verified by those from sled tests. A parameter study is conducted for many physical and mechanical properties. Seat design has been performed based on the design of experiment process with respect to five parameters; seat-back upholstery stiffness, torsional stiffness of the seat-back. An orthogonal array is selected from the parameter study. A good design has been found from the analysis results based on the orthogonal array. The results show that reductions of stiffness in seat-back upholstery and joint are the most effective for preventing neck injuries.

  • PDF

APPLICATION OF A MULTI-WAVELENGTH NIR DIODE LASER ARRAY FOR NON-DESTRUCTIVE FOOD ANALYSIS

  • Tauscher, Bernhard;Butz, Peter;Lindauer, Ralf
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.3123-3123
    • /
    • 2001
  • Near infrared (NIR) spectroscopy has become a widely used method in food and beverage analysis because of its speed, accuracy and the simplicity of sample preparation. One of the basic requirements of NIR instruments is a wide dynamic range if weak, or small, absorption changes or concentrations are to be measured. Thus the instrument must be sufficiently luminous, and efficient, to enable measurements to be made in a reasonably short time, as for some applications (e.g. sorting) short response times are essential. Diode lasers function the same way as lasers but linewidths are not as narrow as typical lasers. In this work an array of seven laser diodes (in the range of 750-1100 nm) with energy outputs of around hundred milliwatts each were combined with a fast diode array spectrometer (400-1100 nm, 1024 pixels, integration time from 3 ms) as detector. Measurements in transmission mode were performed in solutions of sugars in aqueous solutions and in deuteriumoxide. The feasibility of non-destructive measurements in transmission mode was investigated for different fruits and vegetables.

  • PDF

A Study on Particle Diffusion to Develop Faraday Cup Array of Particle Beam Mass Spectrometer System (Faraday cup array 개발을 위한 Particle Beam Mass Spectrometer 시스템 내에서의 입자 확산 연구)

  • Mun, Ji-Hun;Shin, Yong-Hyun;Kim, Tae-Sung;Kang, Sang-Woo
    • Particle and aerosol research
    • /
    • v.8 no.1
    • /
    • pp.29-35
    • /
    • 2012
  • The Faraday cup electrode of different size has been developed and evaluated to investigate the diffusion effect of particles by Brownian motion in a particle beam mass spectrometer(PBMS). Particles which focused and accelerated by aerodynamic lens are charged to saturation in an electron beam, and then deflected electrostatically into a Faraday cup detector for measurement of the particle current. The concentration of particles is converted from currents detected by Faraday cup. Measurements of particle current as a function of deflection voltage are combined with measured relationships between particle velocity and diameter, charge and diameter, and mass and diameter, to determine the particle size distribution. The particle currents were measured using 5, 10, 20, 40 mm sized Faraday cup that can be move to one direction by motion shaft. The current difference for each sizes as a function of position was compared to figure out diffusion effect during transport. Polystyrene latex(PSL) 100, 200 nm sized standard particles were used for evaluation. The measurement using 5 mm sized Faraday cup has the highest resolution in a diffusion distance and the smaller particles had widely diffused.

KEY SCIENCE OBSERVATIONS OF AGNs WITH THE KaVA ARRAY

  • KINO, MOTOKI;NIINUMA, KOTARO;ZHAO, GUANG-YAO;SOHN, BONG WON
    • Publications of The Korean Astronomical Society
    • /
    • v.30 no.2
    • /
    • pp.633-636
    • /
    • 2015
  • KaVA (KVN and VERA Array) is a new combined VLBI array composed of KVN (Korean VLBI Network) and VERA (VLBI Exploration of Radio Astrometry). Here, we report the following two issues. (1) We review the initial results of imaging observations of M87 at 23 GHz following Niinuma et al. (2014). The KaVA images reveal extended outflows including complex substructures such as knots and limb-brightening, in agreement with previous VLBI observations. KaVA achieves a high dynamic range of ~1000, more than three times better than that achieved by VERA alone. (2) Based on subsequent observations and discussions led by the KaVA AGN SubWorking Group, we set monitoring observations of Sgr $A^{\ast}$ and M87 as our Key Science Project (hereafter KSP) because of the closeness and largeness of their central super-massive black holes. The main science goals of the KSP are (i) testing the magnetically-driven-jet paradigm by mapping velocity fields of the M87 jet, and (ii) obtaining tight constraints on physical properties of the radio emitting region in Sgr $A^{\ast}$. Towards KSP, we show the first preliminary images of M87 at 23 GHz and Sgr $A^{\ast}$ at 43 GHz with the bandwidth of 256 MHz.

A Novel Simulation Scheme for Grid Connected Photovoltaic Generation Systems

  • Park, Monwon;Kim, Bong-Tae;Yu, In-Keun
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.11B no.4
    • /
    • pp.169-174
    • /
    • 2001
  • A novel simulation scheme of transient phenomenon for the photovoltaic (PV) generation system under the real weather conditions has been proposed in this paper. A grid connected PV array is simulated using PSCAD/EMTDC. The transient changes of the output current of PV array under the real weather conditions is described and the output current of DC/AC converter flowing through the utility power network is also analyzed with the PWM switching width. Moreover, the MPPT control of PV generation system is combined to the system during the simulation for the comparison purposes of the control schemes. The outcome of the simulation demonstrates the effectiveness of the proposed simulation scheme. The result shows that the cost effective verifying for the efficiency or availability and stability of PV generation systems and the comparison research of various control schemes like MPPT under the same real whether conditions are eventually possible.

  • PDF

A Optimization Procedure for Robust Design (로버스트 설계에 대한 최적화 방안)

  • Kwon, Yong-Man;Hong, Yeon-Woong
    • Proceedings of the Korean Society for Quality Management Conference
    • /
    • 1998.11a
    • /
    • pp.556-567
    • /
    • 1998
  • Robust design in industry is an approach to reducing performance variation of quality characteristic value in products and processes. Taguchi has used the signal-to-noise ratio(SN) to achieve the appropriate set of operating conditions where variability around target is low in the Taguchi parameter design. Taguchi has dealt with having constraints on both the mean and variability of a characteristic (the dual response problem) by combining information on both mean and variability into an SN. Many Statisticians criticize the Taguchi techniques of analysis, particularly those based on the SN. In this paper we propose a substantially simpler optimization procedure for robust design to solve the dual response problems without resorting to SN. Two examples illustrate this procedure. in the two different experimental design(product array, combined array) approaches.

  • PDF

An Optimization Procedure for Robust Design (로버스트 설계에 대한 최적화 방안)

  • 권용만;홍연웅
    • Journal of Korean Society for Quality Management
    • /
    • v.26 no.4
    • /
    • pp.88-100
    • /
    • 1998
  • Robust design in industry is an a, pp.oach to reducing performance variation of quality characteristic value in products and processes. Taguchi has used the signal-to-noise raio(SN) to achieve the a, pp.opriate set of operating conditions where variablity around target is low in the Taguchi parameter design. Taguchi has dealt with having constraints on both the mean and variability of a characteristic (the dual response problem) by combining information on both mean and variability into an SN. Many Statisticians criticize the Taguchi techniques of analysis, particularly those based on the SN. In this paper we propose a substantially simpler optimization procedure for robust design to solve the dual response problems without resorting to SN. Two examples illustrate this procedure in the two different experimental design(product array, combined array) a, pp.oaches.

  • PDF

The Robust Design with Column Merging Method for the Optimal Design of Low Noise Intake System (강건설계와 열합병법을 이용한 세분화한 흡기계 저소음 최적설계)

  • 오재응;차경준;한정순;박영선;진정언
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.10
    • /
    • pp.773-784
    • /
    • 2002
  • This paper proposes an optimal design to improve the performance of the intake system by reducing the noise. We adapt the Taguchi method and column merging method for the above design. At the first stage of the design, the length and radius of each component of the current intake system are selected as control factors. Then the $L^{18}$ table of orthogonal array is used to get the effective main factors. At the second stage, the $L^{16}$ table of orthogonal array and the column merging method is combined to analyze subdivided significant factors. We know that the robust design with the column merging method provides better design for noise of intake system than the robust design itself.

A Multi-photodiode Array-based Retinal Implant IC with On/off Stimulation Strategy to Improve Spatial Resolution

  • Park, Jeong Hoan;Shim, Shinyong;Jeong, Joonsoo;Kim, Sung June
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.17 no.1
    • /
    • pp.35-41
    • /
    • 2017
  • We propose a novel multi-photodiode array (MPDA) based retinal implant IC with on/off stimulation strategy for a visual prosthesis with improved spatial resolution. An active pixel sensor combined with a comparator enables generation of biphasic current pulses when light intensity meets a threshold condition. The threshold is tuned by changing the discharging time of the active pixel sensor for various light intensity environments. A prototype of the 30-channel retinal implant IC was fabricated with a unit pixel area of $0.021mm^2$, and the stimulus level up to $354{\mu}A$ was measured with the threshold ranging from 400 lx to 13120 lx.