• Title/Summary/Keyword: Color measurement

Search Result 889, Processing Time 0.038 seconds

Measurement Coding for Compressive Sensing of Color Images

  • Dinh, Khanh Quoc;Trinh, Chien Van;Nguyen, Viet Anh;Park, Younghyeon;Jeon, Byeungwoo
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.3 no.1
    • /
    • pp.10-18
    • /
    • 2014
  • From the perspective of reducing the sampling cost of color images at high resolution, block-based compressive sensing (CS) has attracted considerable attention as a promising alternative to conventional Nyquist/Shannon sampling. On the other hand, for storing/transmitting applications, CS requires a very efficient way of representing the measurement data in terms of data volume. This paper addresses this problem by developing a measurement-coding method with the proposed customized Huffman coding. In addition, by noting the difference in visual importance between the luma and chroma channels, this paper proposes measurement coding in YCbCr space rather than in conventional RGB color space for better rate allocation. Furthermore, as the proper use of the image property in pursuing smoothness improves the CS recovery, this paper proposes the integration of a low pass filter to the CS recovery of color images, which is the block-based ${\ell}_{20}$-norm minimization. The proposed coding scheme shows considerable gain compared to conventional measurement coding.

A Study on the Measurement of Colour Fastness by CCM and New Fastness Formula (CCM을 이용한 변퇴색 견뢰도 등급의 판정 및 New Fastness Formula에 관한 연구)

  • Hong Min-Gi;Park Ju-Young;Park Yong-Mi;Koo Kang;Huh Man-Woo;Kim Sam-Soo
    • Textile Coloration and Finishing
    • /
    • v.18 no.2 s.87
    • /
    • pp.15-23
    • /
    • 2006
  • A new fastness formula based on CIEDE2000 color-difference formula is developed by B. Rigg and his coworkers. It is very simple to calculate fastness grade for color change than ISO 105-A05 fastness formula based on CIELAB color-difference formula. Sample pair sets which cover a wide range color space were accumulated from NCS(Natural Color System) color book. For those sample pair sets, visual measurement experiment and instrument measurement experiment of fastness grade were carried out and each performance of ISO 105-A02 fastness formula and newly developed fastness formula was compared through degree of agreement for visual measurement result. Newly developed fastness formula indicated improved performance for measuring fastness grade but current ISO fastness formula for assessing change in color, ISO 105-A05, was confirmed that it's performance is inadequate to measure fastness grade. Then fastness formulae were examined more closely according to particular color spaces and the correlation of hue, lightness and chrom for measuring fastness grade was also considered in this study.

Calibration for Color Measurement of Lean Tissue and Fat of the Beef

  • Lee, S.H.;Hwang, H.
    • Agricultural and Biosystems Engineering
    • /
    • v.4 no.1
    • /
    • pp.16-21
    • /
    • 2003
  • In the agricultural field, a machine vision system has been widely used to automate most inspection processes especially in quality grading. Though machine vision system was very effective in quantifying geometrical quality factors, it had a deficiency in quantifying color information. This study was conducted to evaluate color of beef using machine vision system. Though measuring color of a beef using machine vision system had an advantage of covering whole lean tissue area at a time compared to a colorimeter, it revealed the problem of sensitivity depending on the system components such as types of camera, lighting conditions, and so on. The effect of color balancing control of a camera was investigated and multi-layer BP neural network based color calibration process was developed. Color calibration network model was trained using reference color patches and showed the high correlation with L*a*b* coordinates of a colorimeter. The proposed calibration process showed the successful adaptability to various measurement environments such as different types of cameras and light sources. Compared results with the proposed calibration process and MLR based calibration were also presented. Color calibration network was also successfully applied to measure the color of the beef. However, it was suggested that reflectance properties of reference materials for calibration and test materials should be considered to achieve more accurate color measurement.

  • PDF

Uncertainty Evaluation of Color Measurement on Light Sources and Display Devices (광원 및 디스플레이 기기의 색특성 측정의 불확도 평가)

  • Park, Seong-Chong;Lee, Dong-Hoon;Kim, Yong-Wan;Park, Seung-Nam
    • Korean Journal of Optics and Photonics
    • /
    • v.20 no.2
    • /
    • pp.110-117
    • /
    • 2009
  • This work introduces the uncertainty evaluation formulation on color measurement of light sources and display devices, such as CIE 1931 (x, y) chromaticity, CIE 1960 (u, v) chromaticity, correlated color temperature, and distribution temperature. All the mentioned quantities are reduced from spectral data in the visible range, for which uncertainties are strongly correlated between different wavelengths. Using matrix algebra we have formulated the uncertainty propagation from the SI- traceable spectral irradiance standard to the individual color related measurement quantities taking the correlation between wavelengths into account. As a result, we have demonstrated uncertainty evaluation examples of 3 types of light sources: CIE illuminant A, LED white light, and LCD white light. This method can be applied to any other quantities based on spectral measurement such as solar irradiance, material color measurement, etc.

Get Color Image That Using Monochrome CCD Camera and Color Filter, and Color Revision (Monochrome-Camera와 Color-Filter를 이용한 Color Image획득과 색상보정)

  • Kwon O. S.;Park Y. C.
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.329-334
    • /
    • 2005
  • Most people are using a Color-CCD-Camera in other to acquire a color image. But we are getting a color image with the Monochrome-CCD-Camera equipped for Rotation-Color-Filter in front of the camera lens. The Monochrome CCD Camera has some advantages such as the low price. In addition Rotation-Color-Filter's design is very simple. So we can make this structure easily and economically. In this paper, we described how to make a color image from Monocrome-Camera and correcting color well.

  • PDF

Effect of surface finishing treatments on the color stability of CAD/CAM materials

  • Ozen, Funda;Demirkol, Nermin;Oz, Ozge Parlar
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.3
    • /
    • pp.150-156
    • /
    • 2020
  • PURPOSE. The aim of this study was to evaluate the effect of different surface finishing processes on the color stabilities of lithium disilicate glass-ceramics, zirconia-reinforced lithium silicate ceramics, and resin nanoceramics after artificial ageing. MATERIALS AND METHODS. 216 samples were prepared from 3 different CAD/CAM materials (LAVA Ultimate, IPS e.max CAD, VITA Suprinity) with A1 HT color at a size of 14 × 12 mm and a thickness of 0.5 ± 0.05 mm. Color measurements of the samples were performed with a spectrophotometer using color parameters and CIE Lab color system on a gray backing between baseline color and after 5000 cycles of artificial ageing in 4 stages (i.e. the first measurement before the treatment, the second measurement after polishing, the third measurement after cement application, and the fourth measurement after artificial ageing). The results were evaluated using the Variance analysis and Fisher's LSD test. RESULTS. Resin nanoceramics (LU) exhibited higher color change values than zirconia-reinforced lithium silicate (VS) and lithium disilicate (EC) ceramics after artificial ageing. Manual polishing and glazing resulted in similar color change for LU and VS (P>.05). In the EC group, glazing provided statistically different results as compared to the manual polishing and control groups (P<.05). Among the ceramic groups, color change values of the subgroup, which was treated by glazing, of the zirconia-reinforced lithium silicate (VS) and lithium disilicate (EC) samples were below the clinically acceptable level (ΔE < 3.5). CONCLUSION. The lowest color change for all stages was observed in Vita Suprinity.

Filed Application of the Color Concrete Panel with Red Mud and Pigment (레드머드와 착색재를 이용한 컬러 콘크리트 패널 현장적용)

  • Kim, Tae-Cheong;Kim, Jong;Jeon, Chung-Keun;Yeun, Kyu-Won;Yoon, Gi-Woon;Shin, Dong-An
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.11a
    • /
    • pp.19-22
    • /
    • 2009
  • The Study has analyzed the overall material properties, the measurement of forming colors and applicability of color concrete through making color concrete using red mud heated at 800℃mixed with existing pigment and applying it to the actual field. As the results, the slump flow and aeration meet the target value and the compressed strength of the concrete mixed with red mud and pigment is higher than that of the plain. In addition, the measurement of forming colors turn out to be satisfactory and the color forming is excellent. In the field application, the color concrete panel is proved to make sure the beauty of store exits through its various design available.

  • PDF

The real-time three-dimensional shape measurement by prism lens (프리즘 광학계를 이용한 실시간 삼차원 형상 측정)

  • Kim J.S.;Song C.K.;Joo B.K.;Hong J.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.727-731
    • /
    • 2005
  • We introduce a method of color-coded illumination that is simple and fast. The purpose of this study is the real-time shape measurement of three-dimensional object by using color-coded information. The object is illuminated by a prism color spectrum. A color spectrum of a white-light source is imaged onto the object by illumination from one certain direction. The object is observed by a color CCD camera from a direction of observation, which is different from the direction of illumination. It can be evaluated by the red, blue, green using a inherence colors of hue value are good point.

  • PDF

A Novel Color Breakup Measurement Technique for Field Sequential Display

  • Lai, Yueh-Yi;Liao, Wen-Hung;Mo, Chi-Neng
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.1069-1072
    • /
    • 2009
  • Field sequential display has some advantages but color breakup (CBU) is the significant problem. Many researches had introduced several methods to reduce CBU phenomenon, however there are no reliable methods to measure the degree of CBU. In this report, a novel CBU measurement technique which was based on the image processing method and subjective analysis results had proposed to evaluate the degree of CBU. Color Breakup Index (CBI) was presented to be a useful index to recognize the CBU phenomenon in the different field sequential technique displays.

  • PDF

A Study on the Measurement of Spectral Response Characteristics of Color Image Sensor (칼라영상센서의 분광감도 측정에 관한 연구)

  • 박승옥;김홍석
    • Korean Journal of Optics and Photonics
    • /
    • v.6 no.4
    • /
    • pp.266-273
    • /
    • 1995
  • Colors reproduced by color imaging system are affected by various physical factors. The spectral response of the color image sensor is one of the important factors. We developed a spectral response characteristics measurement system which is composed of optical part and color analyzing part. The data from the optical part was analyzed by the color analyzing part and spectral response characteristics of R, G, B three color sensors were obtained. Using this system, the spectral response characteristics of a CCD color camera was measured. From this result, color rendition and linearity of the camera could be analyzed. This measurement system is $.$considered to be very useful for the evaluation of color image sensor characteristics. stics.

  • PDF