• Title/Summary/Keyword: College Link

Search Result 728, Processing Time 0.027 seconds

A Study on the Concept and Clinical Treatment of Link Meridian (유맥(維脈)의 개념과 임상 활용에 대한 고찰)

  • Yun, Ki-ryoung;Baik, Yousang;Jang, Woo-chang;Jeong, Chang-hyun
    • Journal of Korean Medical classics
    • /
    • v.32 no.1
    • /
    • pp.145-158
    • /
    • 2019
  • Objectives : This study attempts to identify the concept of Link meridian in previous medical books, and explore how Link meridian theory was used in a clinical practice focusing on YeTianshi. Methods : This study looked at the medical books related to acupuncture and moxibustion in the past and the part where Link meridian is mentioned in the annotations of "Huangdineijing" and "Nanjing", and examined how medical doctors prior to YeTianshi used Link meridian in a clinical practice. And then this study examined treatment cases in the medical records of YeTianshi. Results & conclusions : Yang-Link meridian and Eum-Link meridian were arranged as ascending route by the majority of medical doctors. However, there are doubts because startpoints of them are not "Jeyanghoe" and "Jeeumgyo" respectively described in "Nanjing". Link meridian is thought to be a structure that connects each meridian passing through crossing points with each crossing point itself as a starting point. Thus, Link meridian can be seen as a role in strengthening the connection of crossing meridians and balancing and controlling those meridians centering on each crossing point. The point that YeTianshi's identifying that pathology of Eight extra meridians associates with liver and kidney(肝腎) to be a symptom of weakness, and his development of Link meridian's physiology and pathology through the relationship with other Eight extra meridians are thought to be more advanced than the previous medicine prior to YeTianshi.

Congestion Aware Fast Link Failure Recovery of SDN Network Based on Source Routing

  • Huang, Liaoruo;Shen, Qingguo;Shao, Wenjuan
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.11 no.11
    • /
    • pp.5200-5222
    • /
    • 2017
  • The separation of control plane and data plane in Software Defined Network (SDN) makes it flexible to control the network behavior, while also causes some inconveniences to the link failure recovery due to the delay between fail point and the controller. To avoid delay and packet loss, pre-defined backup paths are used to reroute the disrupted flows when failure occurs. However, it may introduce large overhead to build and maintain these backup paths and is hard to dynamically construct backup paths according to the network status so as to avoid congestion during rerouting process. In order to realize congestion aware fast link failure recovery, this paper proposes a novel method which installs multi backup paths for every link via source routing and per-hop-tags and spread flows into different paths at fail point to avoid congestion. We carry out experiments and simulations to evaluate the performance of the method and the results demonstrate that our method can achieve congestion aware fast link failure recovery in SDN with a very low overhead.

Link Prediction Algorithm for Signed Social Networks Based on Local and Global Tightness

  • Liu, Miao-Miao;Hu, Qing-Cui;Guo, Jing-Feng;Chen, Jing
    • Journal of Information Processing Systems
    • /
    • v.17 no.2
    • /
    • pp.213-226
    • /
    • 2021
  • Given that most of the link prediction algorithms for signed social networks can only complete sign prediction, a novel algorithm is proposed aiming to achieve both link prediction and sign prediction in signed networks. Based on the structural balance theory, the local link tightness and global link tightness are defined respectively by using the structural information of paths with the step size of 2 and 3 between the two nodes. Then the total similarity of the node pair can be obtained by combining them. Its absolute value measures the possibility of the two nodes to establish a link, and its sign is the sign prediction result of the predicted link. The effectiveness and correctness of the proposed algorithm are verified on six typical datasets. Comparison and analysis are also carried out with the classical prediction algorithms in signed networks such as CN-Predict, ICN-Predict, and PSNBS (prediction in signed networks based on balance and similarity) using the evaluation indexes like area under the curve (AUC), Precision, improved AUC', improved Accuracy', and so on. Results show that the proposed algorithm achieves good performance in both link prediction and sign prediction, and its accuracy is higher than other algorithms. Moreover, it can achieve a good balance between prediction accuracy and computational complexity.

Sensorless Control of Three Phase Converter using estimated Input Phase-Voltage and DC-link Voltage (전원전압과 DC-link 전압 추정을 통한 3상 컨버터 센서리스 제어)

  • Chu, Hung-Seok;Park, Sung-Jun;Kim, Kwong-Tae;Kim, Cheul-U
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1233-1235
    • /
    • 2000
  • A new control method of three phase converter without measuring input phase-voltage and DC-link voltage is proposed. Input phase-voltage of these required voltages is estimated using EKF(Extended Kalman Filter) and DC-link voltage is estimated from the measured line currents and the estimated input phase-voltage. This control method is achieved without PLL(Phase Locked Loop) which senses the angle of input phase-voltage and DC-link voltage sensor. In addition, the proposed method controls high power factor and DC-link voltage utilizing the estimated phase angle. This paper describes the effectiveness of the proposed estimated algorithm through simulations.

  • PDF

Prosthetic restorations with cementless screw-retained implant systems: a case report (시멘트리스 나사 유지형 임플란트 시스템을 이용한 보철물 수복 증례)

  • Young-hae Jung;Im-Sun Kim
    • Journal of Technologic Dentistry
    • /
    • v.45 no.4
    • /
    • pp.124-130
    • /
    • 2023
  • This study aims to describe the clinical experience of single and bridge crowns fabricated using a cementless screw-retained implant prosthesis system. In the case of single crown (#37), regular link (HDL) was used, and bridge crowns (#15~#24), (#26~#27), (#17~#14) (#24~#26) were fabricated by selecting regular link and short link considering the vertical height. One abutment was hex shaped to ensure that it could be mounted while preventing insertion and prosthesis rotation. The advantages of cementless implant prosthesis include shorter chair time and periodic care, strong retention with LINK abutment, safety from inflammation, bacterial infection, and complications due to peri-implant cement, and high patient satisfaction. Dentists should double-check the position of the implant fixture and dental technicians should continuously manage the fit of the link and prosthesis with digital equipment to reduce screw loosening and fractures.

An Improved Shared-Path Protection Algorithm for Double-Link Failures in Meshed WDM Optical Networks

  • Wang, Xingwei;Guo, Lei;Li, Lemin;Wei, Xuetao
    • Journal of Communications and Networks
    • /
    • v.10 no.3
    • /
    • pp.331-337
    • /
    • 2008
  • In this paper, we investigate survivability in wavelength division multiplexing (WDM) mesh networks and propose a new algorithm called improved shared-path protection (ISPP) to completely tolerate the double-link failures. Compared with previous algorithms for protecting double-link failures, i.e., shared-path protection (SPP) and shared-link protection (SLP), the advantage of ISPP is to allow primary paths and backup paths to share the mixed wavelength-links based on the proposed new rules in which some primary wavelength-links can be changed to mixed wavelength-links, which can be shared by primary paths and backup paths. In addition, some mixed wavelength-links also can be shared by different backup paths for saving resources. Simulation results show that ISPP algorithm performs better in resource utilization ratio and blocking probability than conventional SPP and SLP algorithms.

Energy-efficient Custom Topology Generation for Link-failure-aware Network-on-chip in Voltage-frequency Island Regime

  • Li, Chang-Lin;Yoo, Jae-Chern;Han, Tae Hee
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.16 no.6
    • /
    • pp.832-841
    • /
    • 2016
  • The voltage-frequency island (VFI) design paradigm has strong potential for achieving high energy efficiency in communication centric manycore system-on-chip (SoC) design called network-on-chip (NoC). However, because of the diminished scaling of wire-dimension and supply voltage as well as threshold voltage in modern CMOS technology, the vulnerability to link failure in VFI NoC is becoming a crucial challenge. In this paper, we propose an energy-optimized topology generation technique for VFI NoC to cope with permanent link failures. Based on the energy consumption model, we exploit the on-chip communication traffic patterns and characteristics of link failures in the early design stage to accommodate diverse applications and architectures. Experimental results using a number of multimedia application benchmarks show the effectiveness of the proposed three-step custom topology generation method in terms of energy consumption and latency without any degradation in the fault coverage metric.

Monitoring of Chemical Processes Using Modified Scale Space Filtering and Functional-Link-Associative Neural Network (개선된 스케일 스페이스 필터링과 함수연결연상 신경망을 이용한 화학공정 감시)

  • Park, Jung-Hwan;Kim, Yoon-Sik;Chang, Tae-Suk;Yoon, En-Sup
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.6 no.12
    • /
    • pp.1113-1119
    • /
    • 2000
  • To operate a process plant safely and economically, process monitoring is very important. Process monitoring is the task to identify the state of the system from sensor data. Process monitoring includes data acquisition, regulatory control, data reconciliation, fault detection, etc. This research focuses on the data recon-ciliation using scale-space filtering and fault detection using functional-link associative neural networks. Scale-space filtering is a multi-resolution signal analysis method. Scale-space filtering can extract highest frequency factors(noise) effectively. But scale-space filtering has too large calculation costs and end effect problems. This research reduces the calculation cost of scale-space filtering by applying the minimum limit to the gaussian kernel. And the end-effect that occurs at the end of the signal of the scale-space filtering is overcome by using extrapolation related with the clustering change detection method. Nonlinear principal component analysis methods using neural network have been reviewed and the separately expanded functional-link associative neural network is proposed for chemical process monitoring. The separately expanded functional-link associative neural network has better learning capabilities, generalization abilities and short learning time than the exiting-neural networks. Separately expanded functional-link associative neural network can express a statistical model similar to real process by expanding the input data separately. Combining the proposed methods-modified scale-space filtering and fault detection method using the separately expanded functional-link associative neural network-a process monitoring system is proposed in this research. the usefulness of the proposed method is proven by its application a boiler water supply unit.

  • PDF

An Inductive-coupling Link with a Complementary Switching Transmitter and an Integrating Receiver

  • Jeong, Youngkyun;Kim, Hyun-Ki;Kim, Sang-Hoon;Kwon, Kee-Won;Chun, Jung-Hoon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.14 no.2
    • /
    • pp.227-234
    • /
    • 2014
  • A transceiver for a high-speed inductive-coupling link is proposed. The bi-phase modulation (BPM) signaling scheme is used due to its good noise immunity. The transmitter utilizes a complementary switching method to remove glitches in transmitted data. To increase the timing margin on the receiver side, an integrating receiver with a pre-charging equalizer is employed. The proposed transceiver was implemented via a 130-nm CMOS process. The measured timing window for a $10^{-12}$ bit error rate (BER) at 1.8 Gb/s was 0.33 UI.