• 제목/요약/키워드: Collapse behavior analysis

검색결과 272건 처리시간 0.032초

Collapse-resistant performance of a single-story frame assembly and multi-story sub-frame under an internal column-removal scenario

  • Zhong, Wei-hui;Tan, Zheng;Tian, Li-min;Meng, Bao;Zheng, Yu-hui;Daun, Shi-chao
    • Steel and Composite Structures
    • /
    • 제41권5호
    • /
    • pp.663-679
    • /
    • 2021
  • To elucidate the differences in the collapse behavior between a single-story beam-column assembly and multi-story frame, two 1/3-scale two-bay composite frames, including a single-story composite beam-column assembly and a three-story composite sub-frame, were designed and quasi-statically tested. The load-displacement responses, failure modes, and internal force development of the two frames were analyzed and compared in detail. Furthermore, the resistance mechanisms of the two specimens were explored, and the respective contributions of different load-resisting mechanisms to the total resistances were quantitatively separated to gain deeper insights. The experimental tests indicated that Vierendeel action was present in the two-dimensional multi-story frames, which led to an uneven internal force distribution among the three stories. The collapse resistance of TSDWA-3S in the flexural stage was not significantly increased by the structural redundancy provided by the additional story, as compared to that of TSDWA-1S. Although the development of the load response was similar in the two specimens at flexural stage, the collapse mechanisms of the multi-story composite frame were much more complicated than those of the single-story beam-column assembly, and the combined action between stories was critical in determining the internal force redistribution and rebalancing of the remaining structure.

Detailed Finite Element Analysis of Full-scale Four-story Steel Frame Structure subjected to Consecutive Ground Motions

  • Tagawa, Hiroyuki;Miyamura, Tomoshi;Yamashita, Takuzo;Kohiyama, Masayuki;Ohsaki, Makoto
    • 국제초고층학회논문집
    • /
    • 제4권1호
    • /
    • pp.65-73
    • /
    • 2015
  • Detailed finite element (FE) analyses of a full-scale four-story steel frame structure, subjected to consecutive 60% and 100% excitations from the JR Takatori records during the 1995 Hyogoken-Nanbu earthquake, are conducted using E-Simulator. The four-story frame was tested at the largest shake-table facility in the world, E-Defense, in 2007. E-Simulator is a parallel FE analysis software package developed to accurately simulate structural behavior up to collapse by using a fine mesh of solid elements. To reduce computational time in consecutive dynamic time history analyses, static analysis with gravity force is introduced to terminate the vibration of the structure during the analysis of 60% excitation. An overall sway mechanism when subjected to 60% excitation and a story mechanism resulting from local buckling of the first-story columns when subjected to 100% excitation are simulated by using E-Simulator. The story drift response to the consecutive 60% and 100% excitations is slightly smaller than that for the single 100% excitation.

Methodology for investigating the behavior of reinforced concrete structures subjected to post earthquake fire

  • Behnam, Behrouz;Ronagh, Hamid R.;Baji, Hassan
    • Advances in concrete construction
    • /
    • 제1권1호
    • /
    • pp.29-44
    • /
    • 2013
  • Post earthquake fire (PEF) can lead to the collapse of buildings that are partially damaged in a prior ground-motion that occurred immediately before the fire. The majority of standards and codes for the design of structures against earthquake ignore the possibility of PEF and thus buildings designed with those codes could be too weak when subjected to a fire after an earthquake. An investigation based on sequential analysis inspired by FEMA356 is performed here on the Life-Safety performance level of structures designed to the ACI 318-08 code after they are subjected to two different earthquake levels with PGA of 0.35 g and 0.25 g. This is followed by a four-hour fire analysis of the weakened structure, from which the time it takes for the weakened structure to collapse is calculated. As a benchmark, the fire analysis is also performed for undamaged structure and before occurrence of earthquake. The results show that the vulnerability of structures increases dramatically when a previously damaged structure is exposed to PEF. The results also show the damaging effects of post earthquake fire are exacerbated when initiated from second and third floor. Whilst the investigation is for a certain class of structures (regular building, intermediate reinforced structure, 3 stories), the results confirm the need for the incorporation of post earthquake fire in the process of analysis and design and provides some quantitative measures on the level of associated effects.

송전철탑의 극한하중 도출을 위한 비선형해석 기법 (Development of Nonlinear Analysis Technic to Determine the Ultimate Load in Electric Transmission Tower)

  • 김우범;최병정;안진규
    • 한국강구조학회 논문집
    • /
    • 제20권3호
    • /
    • pp.389-398
    • /
    • 2008
  • 현행 송전철탑의 경우 허용응력 설계개념을 도입한 철탑설계기준을 적용하여 설계, 제작되고 있으나 탄성해석을 전제로 한 허용응력 설계기법으로는 송전철탑의 명확한 도괴 원인을 규명할 수가 없다. 철탑 도괴의 원인을 규명하기 위해서는 철탑 부 재 및 접합부의 재료 및 기하학적 비선형성을 고려한 2차 변형효과를 고려하여야 한다. 2차 변형에 영향을 주는 요인으로는 부재의 잔류응력, 초기변형, 접합부의 단부구속도 등이 있으며 이는 비선형 대변형 해석을 통하여 거동 파악이 가능하다. 본 연구에서는 선형해석과 비선형해석의 비교를 통하여 비선형 해석의 필요성을 확인하고 비선형 유한요소해석에 따르는 해석상의 복잡함을 줄이기 위해서 등가비선형 해석기법을 개발하고 이로부터 도출된 철탑의 극한하중을 비선형 유한요소해석의 극한하중과 비교를 함으로써 개발기법의 신뢰성을 확인하였다. 개발된 해석기법을 바탕으로 사재의 축력 및 세장비가 주주재의 최대내력에 미치는 영향을 파악하고 실무적 편의성을 제공하기 위하여 이를 도표화 하였다.

원형평판의 붕괴문제에 관한 유한차분 완전 하계해 (Complete lower bound solutions of circular plate collapse problems by a finite difference method)

  • 허훈
    • 대한기계학회논문집
    • /
    • 제14권6호
    • /
    • pp.1382-1390
    • /
    • 1990
  • 본 연구에서는 Yang의 이론을 바탕으로 여러가지 원형집중하중을 받는 원형평 판에 관한 최대하계해를 구하고자 한다.앞서 열거한 문헌에서는 여러가지 해석법이 제시되었으나, 문제의 성격에 비하여 그 해법이 매우 복잡하였다. 본 논문에서는 원 형평판에 관한 해법으로서 전산기를 응용하여 가능한 한 단순한 해법으로 최대화기법 에 의한 완전한 해를 얻기 위한 시도를 제시하고자 한다.

Capacity design of boundary elements of beam-connected buckling restrained steel plate shear wall

  • Liu, Wen-Yang;Li, Guo-Qiang;Jiang, Jian
    • Steel and Composite Structures
    • /
    • 제29권2호
    • /
    • pp.231-242
    • /
    • 2018
  • As a lateral load resisting component, buckling restrained steel plate shear walls (BRW) have excellent energy dissipating capacity. Similar to thin steel plate shear walls, the mechanical behavior of BRWs depends on the boundary elements (adjacent beams and columns) which need adequate strength and stiffness to ensure the complete yielding of BRWs and the emergence of expected plastic collapse mechanism of frame. This paper presents a theoretical approach to estimate the design forces for boundary elements of beam-connected BRW (i.e., The BRW is only connected to beams at its top and bottom, without connections to columns) using a fundamental plastic collapse mechanism of frame, a force transferring model of beam-connected BRW and linear beam and column analysis. Furthermore, the design method of boundary beams and columns is presented. The proposed approach does not involve nonlinear analyses, which can be easily and efficiently used to estimate the design forces of beams and columns in a frame with BRWs. The predicted design forces of boundary elements are compared with those from nonlinear finite element analyses, and a good agreement is achieved.

알루미늄-복합재료 혼성 사각관 보의 굽힘 성능평가 (Bending Performance Evaluation of Aluminum-Composite Hybrid Square Tube Beams)

  • 이성혁;최낙삼
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2005년도 춘계학술발표대회 논문집
    • /
    • pp.76-79
    • /
    • 2005
  • Bending deformation and energy absorption characteristics of aluminum-composite hybrid tube beams have been analyzed for improvement in the bending performance of aluminum space frame by using experimental tests combined with theoretical and finite element analyses. Hybrid tube beams composed of glass fabric/epoxy layer wrapped around on aluminum tube were made in autoclave with the recommended curing cycle. Basic properties of aluminum material used for initial input data of the finite element simulation and theoretical analysis were obtained from the true stress-true strain curve of specimen which had bean extracted from the Al tube beam. A modified theoretical model was developed to predict the resistance to the collapse of hybrid tube beams subjected to a bending load. Theoretical moment-rotation angle curves of hybrid tube beams were in good agreement with experimental ones, which was comparable to the results obtained from finite element simulation. Hybrid tube beams strengthened by composite layer on the whole web and flange showed an excellent bending strength and energy absorption capability.

  • PDF

알루미늄합금 선체의 최종 종강도에 대한 해석 (Longitudinal Ultimate Strength Analysis of Aluminum Alloy Ship Structures)

  • 백점기;이제명;박철민;박영일;고재용
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2004년도 가을 학술발표회 논문집
    • /
    • pp.254-261
    • /
    • 2004
  • Until now, there are different kinds of design and evaluation method criteria for ship hulls and ship strength based on allowable stress design using past experiences. But for many sinking accidents of large ships in operation, it has also a doubt about allowable stress design. It is recognized that structural plastic collapse caused by large external force is a main cause of that accidents. Therefore, there is the need for new design criteria based on ultimate limit state with a consideration about progressive collapse behavior as a safety assessment of ship hulls. Also many aluminum alloy ships is built for the purposes of lightweight of ship hulls, with that, a developing of criteria based on ultimate limit state should be made. In this study, the ultimate strength characteristics of aluminum ship hull are investigated by the ALPS/USAS program using already developed design formula for aluminum plate and stiffened panel.

  • PDF

차량 충돌에 의한 기둥의 콘크리트 기초 접합부 거동 평가 (Behavior of Column-Foundation Joint under Vehicle Impact)

  • 강현구;김진구
    • 콘크리트학회논문집
    • /
    • 제26권3호
    • /
    • pp.393-400
    • /
    • 2014
  • 구조물은 사고 혹은 테러에 의한 공격 등과 같은 차량에 의한 충돌에 노출되어 있으며, 차량 충격이 구조물의 주요 기둥에 발생 할 경우 구조물 전체가 연쇄붕괴로 인하여 붕괴 할 수 있다. 이 연구에서는 차량 충격하중을 받는 강재 기둥과 콘크리트 기초 상부 접합부의 거동 및 보강방법에 관하여 분석하였다. 충돌해석을 위하여 모델링 된 단일 강재 기둥의 크기와 기둥이 받는 축 하중의 양은 일반적인 3층, 6 m길이의 3경간 구조물의 1층에 위치한 기둥으로 가정하였다. 또한 충돌해석에 사용한 8톤 트럭은 미국 NCAC(National Crash Analysis Center)에서 제공한 모델을 사용하였다. 충돌 해석은 상용 유한요소 프로그램인 LS-DYNA를 사용하였으며 차량 충돌해석 해석 결과, 충격하중을 받는 기둥은 기초 상부 앵커볼트 및 접합부 형태에 큰 영향을 받는 것으로 나타났다.

Estimating uncertainty in limit state capacities for reinforced concrete frame structures through pushover analysis

  • Yu, Xiaohui;Lu, Dagang;Li, Bing
    • Earthquakes and Structures
    • /
    • 제10권1호
    • /
    • pp.141-161
    • /
    • 2016
  • In seismic fragility and risk analysis, the definition of structural limit state (LS) capacities is of crucial importance. Traditionally, LS capacities are defined according to design code provisions or using deterministic pushover analysis without considering the inherent randomness of structural parameters. To assess the effects of structural randomness on LS capacities, ten structural parameters that include material strengths and gravity loads are considered as random variables, and a probabilistic pushover method based on a correlation-controlled Latin hypercube sampling technique is used to estimate the uncertainties in LS capacities for four typical reinforced concrete frame buildings. A series of ten LSs are identified from the pushover curves based on the design-code-given thresholds and the available damage-controlled criteria. The obtained LS capacities are further represented by a lognormal model with the median $m_C$ and the dispersion ${\beta}_C$. The results show that structural uncertainties have limited influence on $m_C$ for the LSs other than that near collapse. The commonly used assumption of ${\beta}_C$ between 0.25 and 0.30 overestimates the uncertainties in LS capacities for each individual building, but they are suitable for a building group with moderate damages. A low uncertainty as ${\beta}_C=0.1{\sim}0.15$ is adequate for the LSs associated with slight damages of structures, while a large uncertainty as ${\beta}_C=0.40{\sim}0.45$ is suggested for the LSs near collapse.