Abstract
The current design practice of electric transmission tower is based on the allowable stress design. However, it is difficult to find the cause behind a transmission tower's collapse by the above design approach as the collapse is caused by large secondary deformations based on and geometrical nonlinear behavior.influence factor for the nonlinear behavior is mainly residual stress, initial imperfection and end restraints on members. In this study, the necessity of the nonlinear analysis is examined through the comparison between elastic ana the nonlinear analysis, a new analytical method (equivalent nonlinear analysis technique) is proposed. To confirm the reliability of the proposed method, the computed ultimate load of the transmission tower using the method was compared with that of the nonlinear finite element analysis. Effects of parameters, such as compressive force and the slenderness ratio of the brace member on the main post member, were investigated. The effective member length according to influential parameters was formulated in table form for practical purposes.
Keywords
electric transmission tower; nonlinear analysis; ultimate load;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Siu Lai Chan and Sritawat Kitipornchai, 1998, Inelastic Post-Buckling Behavior of Tubular Struts, ASCE, Journal of Structural Engineering. Vol. 114, No. 5, pp.1091-1104   DOI   ScienceOn
2 한국전력공사, 1997, 가공송전용 철탑설계기준 송전편, 설계기준-1111
3 F. Bleich, McGraw-Hill, Buckling Strength of Metal Structures, 1952, pp.20-30
4 F.G.A. Al-Bermani and S. Kitipornchai, 1992, Nonlinear analysis of transmission towers, Eng. Struct., vol. 14, No. 3, pp.139-151   DOI   ScienceOn
5 ABAQUS User's Manual Version 6.5, Hibbit Karlsson, and Sorensen, Inc.,Pawtucke, R,I.
6 A.C. Walker, 1984, Buckling of offshore Structures.
7 김우범, 2005, 송전철탑 가섭선의 대변형을 고려한 비선형 광역 모델링 개발, 전력선행기술 논문집
8 (사)한국강구조학회, 2004, 강구조의 설계, pp.318-382
9 S. Roy, 1984, Secondary Stresses on Transmission Tower Structures, ASCE, Journal of Structural Engineering. Vol. 110, No. 2, pp.157-172   DOI   ScienceOn