• 제목/요약/키워드: Cold Joint

검색결과 191건 처리시간 0.028초

Effects of loading conditions and cold joint on service life against chloride ingress

  • Yang, Keun-Hyeok;Mun, Ju-Hyun;Yoon, Yong-Sik;Kwon, Seung-Jun
    • Computers and Concrete
    • /
    • 제22권3호
    • /
    • pp.319-326
    • /
    • 2018
  • RC (Reinforced Concrete) members are always subjected to loading conditions and have construction joints when constructed on a big scale. Service life for RC structure exposed to chloride attack is usually estimated through chloride diffusion test in sound concrete, however the test is performed without consideration of effect of loading and joint. In the present work, chloride diffusion coefficient is measured in concrete cured for 1 year. In order to evaluate the effect of applied load, cold joint, and mineral admixtures, OPC (Ordinary Portland Cement) and 40%-replaced GGBFS (Ground Granulated Blast Furnace Slag) concrete are prepared. The diffusion test is performed under loading conditions for concrete containing cold joint. Investigating the previous test results for 91 days-cured condition and the present work, changing diffusion coefficients with applied stress are normalized considering material type and cold joint. For evaluation of service life in RC continuous beam with 2 spans, non-linear analytical model is adopted, and service life in each location is evaluated considering the effects of applied stress, cold joint, and GGBFS. From the work, varying service life is simulated under various loading conditions, and the reduced results due to cold joint and tensile zone are quantitatively evaluated. The effect of various conditions on diffusion can provide more quantitative evaluation of chloride behavior and the related service life.

관절염환자에게 적용한 냉요법과 온요법의 효과비교 (A Study on Comparisons of the Effect of Local Heat and Cold Therapy on the Symptoms of the Arthritic Knee Joint)

  • 임난영
    • 근관절건강학회지
    • /
    • 제2권1호
    • /
    • pp.73-86
    • /
    • 1995
  • Heat and cold often produce a similar clinical effect but different physiologic mechanisms. The purpose of this study was to compare the effects of local heat and cold therapy on joint pain, discomfort and, ROM of the arthritic knee joint. Thirty female subjects took Ice bag and hot bag with random assignment of initial therapy Subjects rated the degree of Joint pain and discomfort before and after each therapy, and then ROM was measured. The results of the study were as follows : 1. The hot bag group showed significantly lower joint pain & discomfort score than the ice bag group. ROM was increased in the hot bag group compared with subjects in the ice bag group. But there is not significant differences. 2. The ice bag group showed significantly lower joint pain score after than before therapy. But there are no significant differences in discomfort score & ROM between after & before therapy. 3. The hot bag group showed significantly lower joint pain, discomfort score after than before therapy. ROM was significantly increased after than before therapy in hot bag group. Therefore hot bag was significantly more effective than the ice bag in relieving the arthritic joint symptoms. A further study is necessary to determine the effect of local heat and cold therapy including the related variables such as preference for heat or cold.

  • PDF

콜드조인트를 가진 OPC 및 GGBFS 콘크리트의 투수성 평가 (Permeability Evaluation of OPC and GGBFS Concrete with Cold Joint)

  • 최세진;김성준;문진만;권성준
    • 콘크리트학회논문집
    • /
    • 제27권4호
    • /
    • pp.435-441
    • /
    • 2015
  • 콘크리트는 다공성 매채로 투수성을 가지고 있으며, 투수성은 내구성 평가의 중요한 인자가 된다. 콘크리트는 이어치기의 지연을 통해서 콜드조인트를 가지게 되는데, 이러한 이음은 투수와 유해물질의 유입을 가속화시킨다. 본 연구에서는 고로 슬래그 미분말과 보통포틀랜트 시멘트를 사용하여 콜드조인트 콘크리트를 제조하였으며, 91일 재령 하에서 2주간 투수계수 및 유량을 측정하였다. 고로슬래그 미분말을 혼입한 배합에서는 투수성이 OPC 배합에 비해 0.89배 감소하였으며, 콜드조인트에도 보통배합에 비해 투수계수가 0.86배 감소하였다. 본 연구에서는 저압 투수법을 통하여 콜드조인트 및 혼화재가 투수성에 미치는 영향이 평가되었으며, 확률론적인 방법을 통하여 건전부와 콜드조인트부의 투수 변동성 또한 분석되었다.

고로슬래그 미분말을 혼입한 콜드조인트 콘크리트의 염화물 확산계수 (Chloride Diffusion Coefficients in Cold Joint Concrete with GGBFS)

  • 오경석;문진만;권성준
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제20권5호
    • /
    • pp.44-49
    • /
    • 2016
  • 철근 콘크리트 구조물의 철근에 대한 부식을 발생시키는 다양한 유해 열화인자 중 염화물 이온(Cl-)은 침투로 인한 확산속도가 빠르고, 철근에 직접적으로 관여하여 부식을 야기시켜 매우 중요한 열화원인이다. 대형 콘크리트 구조물의 타설에서 불가피하게 발생하는 콜드 조인트는 전단력에 취약하여, 이는 내구적 열화에 대한 피해를 증가시키는 경향을 보인다. 본 연구에서는 콜드조인트를 가진 OPC(Ordinary Portland Cement) 콘크리트와 GGBFS(Ground Granulated Blast Furnace Slag) 염화물 촉진 실험으로 염화물 확산계수를 정량적으로 평가하였다. GGBFS 콘크리트에서는 $6.6{\times}10^{-12}m^2/sec$의 확산계수가 측정되었는데. 이는 OPC 콘크리트에 비하여 약 30% 수준의 낮은 확산계수값을 나타내었으며, 콜드조인트를 가진 콘크리트에서도 비슷한 경향이 관측되었다. OPC 건전부 콘크리트에 비하여 GGBFS 콘크리트의 염화물 확산계수는 건전부에서 0.30배, 콜드조인트부에서 0.39배 정도의 우수한 염해 저항성을 나타내었다.

Behaviour of RC beam-column joint with varying location of construction joints in the column

  • Vanlalruata, Jonathan;Marthong, Comingstarful
    • Earthquakes and Structures
    • /
    • 제20권1호
    • /
    • pp.29-38
    • /
    • 2021
  • According to ACI 224.3R-95 (ACI, 2013), construction joints (cold joint) in the column are to be provided at the top of floor slab for column continuing to the next floor and underside of floor slab and beam. A recent study reveals that providing cold joint of the mentioned location significantly reduced the seismic performance of the frame structures. Since, the construction joints in multi-story frame structures normally provided at the top of the floor slabs and at soffit of the beam in the column. This study investigated the effect of construction joint at various location in the column of beam-column joint such as at the top of floor slab, soffit level of the beam, half the depth of beam below the soffit of the beam and at a full depth of the beam below the soffit of the beam. The study revealed that there is an improvement in seismic capacity of the specimens as the location of cold joint is placed away from the soffit of the beam for lower story column.

인장 및 압축영역에서 콜드조인트 콘크리트의 염화물 확산계수 평가 (Evaluation of Chloride Diffusion Coefficients in Cold Joint Concrete Considering Tensile and Compressive Regions)

  • 문진만;권성준
    • 콘크리트학회논문집
    • /
    • 제28권4호
    • /
    • pp.481-488
    • /
    • 2016
  • 콘크리트는 공용기간동안 구조물 자체의 자중 및 이동 하중에 따른 응력을 받게 되며, 이러한 응력은 구조적인 거동뿐 아니라 내구적인 거동에도 영향을 준다. 대단위 콘크리트 부재의 시공은 시공이음을 요구하는데, 면처리 불량 또는 이어치기의 지연에 의해 콜드조인트가 발생하게 된다. 이러한 콜드조인트는 전단력에 취약할 뿐 아니라 염화물 확산성에도 영향을 미친다. 본 연구에서는 응력조건과 콜드조인트가 콘크리트의 염화물 확산에 미치는 영향을 정량적으로 평가하였다. 콜드조인트를 가진 콘크리트는 인장하중 수준이 30%에서 60%로 커질 때, 확산계수는 꾸준하게 증가하여 건전부와 큰 차이를 보이지 않았다. 그러나 압축부에서는 하중재하 30% 수준부터 콜드조인트 콘크리트에서 염화물 확산계수가 크게 증가하여 확산계수가 170% 이상 증가하였다. 이러한 특성은 압축하중을 받는 건전부 콘크리트와 큰 차이가 있으므로 이음부를 가지는 콘크리트의 내구성 설계에 주의가 필요하다.

OPC 및 GGBFS를 혼입한 콘크리트의 하중조건과 콜드조인트에 따른 내구수명 변화 (Changes in Service life in RC Containing OPC and GGBFS Considering Effects of Loadings and Cold Joint)

  • 김혁중;권성준
    • 한국건설순환자원학회논문집
    • /
    • 제5권4호
    • /
    • pp.466-473
    • /
    • 2017
  • 콘크리트 구조물은 동일한 환경에 노출되었다 하더라도 하중특성과 콜드조인트 유무에 따라서 확산특성이 변화하고 이에 따라 내구수명이 변하게 된다. 본 연구에서는 기존의 선행연구를 분석하여 OPC 및 GGBFS를 사용한 콘크리트의 압축특성, 인장특성, 콜드조인트를 고려한 함수를 도출하였다. 경간 10.0m의 단순보를 가정하여 하중을 2.5kN/m에서 균열모멘트에 이르는 5.5kN/m까지 증가시키면서 내구수명을 평가하였다. 최대 하중에 이를 경우, 건전부 OPC 콘크리트의 경우 인장영역에서는 89.4%로, 압축영역에서는 101%로 내구수명이 변화하였으며, GGBFS 콘크리트의 경우 80.0%와 106%의 변화가 발생하였다. 콜드조인트의 경우 GGBFS를 사용한 콘크리트에서는 압축부에서는 82~80%로, 인장부에서는 69~61% 수준으로 크게 감소하였는데, 건전부의 확산계수가 OPC에 비하여 작지만 콜드조인트부의 확산성 증가가 상대적으로 크기 때문이다.

등속조인트용 외륜의 다단 냉간 단조공정에 관한 실험적 연구 (Experimental Study on Multi-Stage Cold Forging for an Outer Race of a CV Joint)

  • 강범수;구태완
    • 소성∙가공
    • /
    • 제23권4호
    • /
    • pp.221-230
    • /
    • 2014
  • This study deals with a series of experimental investigations on multi-stage cold forging of an outer race used for a constant velocity (CV) joint with six inner ball grooves. The multi-stage cold forging, which consists of forward extrusion, upsetting, backward extrusion, and combined sizing-necking including ironing, was used to produce a prototype of the outer race. The cold forging tools such as forging punches and dies required in this multi-stage cold forging were also designed and fabricated. For the combined sizing-necking, especially, the longitudinally six-segmentallized punches were developed to easily eject from the necked inner groove of the outer race with consideration of the operating mechanism. Spheroidized SCr420H billet was used in the experimental study. To verify the suitability of the proposed process, the obtained parts were obtained from each forging operation, and the geometries were compared with the target dimensions. It was confirmed that the outer race with six inner ball grooves was well forged by adopting the proposed multi-stage cold forging, and the dimensional accuracy of the forged outer race matched well with the requirements.