Analysis of Test Operations Effect of Open-Closed Loops Complex Geothermal System Combined with Groundwater Well (지하수정호 결합 복합지열시스템의 시범운영 효과분석)

  • Song, Jae-Yong;Kim, Ki-Joon;Lee, Geun-Chun;Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.28 no.3
    • /
    • pp.475-488
    • /
    • 2018
  • This study evaluates geothermal system efficiency in terms of input power and heat exchange volume on the heat-source and load sides, by applying a combined open-closed type loop system comprising a geothermal system and a groundwater well to a cultivation site. In addition, this study analyzes the effects of heating and cooling for a complex geothermal system, by evaluating the temperatures of an external site and a cultivation site during operation. During cooling operations the heat exchange volume on the heat source side, average 90.0kW/h for an open type system with an input of 235L/minute groundwater, and 40.1kW/h for a closed type system with an input of 85L/minute circulating water, for a total average heat exchange volume of 130.1kW/h. The actual heat exchange volume delivered on the load side averages 110.4kW/h. The average EER by analysis of the geothermal system's cooling efficiency is 5.63. During heating operation analysis, the heat exchange volume on the heat source side, average 60.4kW/h in an open type system with an input of 266L/minute groundwater, and 22.4kW/h in closed type system with an input of 86L/minute circulating water, for a total average heat exchange volume of 82.9kW/h. The actual heat exchange volume delivered on the load side averages 112.0kW/h in our analysis. The average COP determined by analysis of the geothermal system's heating efficiency is 3.92. Aa a result of the tradeoff between the outside temperature and the inside temperature of the production facility and comparing the facility design with a combined well and open-closed loops geothermal(CWG) system, we determine that the 30RT-volume CWG system temperature are lower by $3.4^{\circ}C$, $6.8^{\circ}C$, $10.1^{\circ}C$ and $13.4^{\circ}C$ for ouside temperature is of $20^{\circ}C$, $25^{\circ}C$, $30^{\circ}C$ and $35^{\circ}C$, respectively. Based on these results, a summer cooling effect of about $10^{\circ}C$ is expected relative to a facility without a CWG system as the outside temperature is generally ${\geq}30^{\circ}C$. Our results suggest that a complex geothermal system provides improvement under a variety of conditions even when heating conditions in winter are considered. Thus It is expected that the heating-cooling tradeoffs of complex geothermal system are improved by using water screen.

Giant Neurofibroma on Both Buttocks (양측 엉덩이의 거대 신경섬유종)

  • Kim, Ji Hoon;Burm, Jin Sik;Kim, Yang Woo;Kang, So Ra;Kim, Hyoung Kyoung
    • Archives of Plastic Surgery
    • /
    • v.36 no.4
    • /
    • pp.512-515
    • /
    • 2009
  • Purpose: Neurofibromatosis(NF) is an autosomal - dominant systemic disease. Up to fifty percent of patients with NF are reported to have concomitant vascular abnormalities. In the resection of a larger NF, the risk of uncontrolled hemorrhage is much higher due to the difficulty of hemostasis of large vessels within the tumor. We ligated the base of the giant NF with a simple loop - shaped ligation before removal of the giant NF in both buttocks. And then we could successfully reduce the amount of hemorrhage during the operation. Methods: A 46 - year - old female patient presented for giant masses of both gluteal area, which has been growing slowly for the last ten years. Each mass was about $30{\times}20cm$ in size. After designing the elliptical resection margin, we tightened the tumor base by using continuous loop - shaped suture ligation(weaving the thread up and down in a loop - shaped pattern, leaving a space of 2 cm between each loop) with a straight needle and prolene 2 - 0. After skin incision, we proceeded the dissection toward the central and inferior side of the mass obliquely while we avoided breaking large vascular sinuses. We resected the tumor in a wedged - shape. Subcutaneous tissue was sutured layer by layer and skin was closed by vertical mattress and interrupted suture. The loop - shaped ligation of the base was removed and compressive dressing was done with gauzes and elastic bandages. Results: Postoperative complications such as infection, hemorrhage, hematoma, and dehiscense did not occur. Perioperatively the patient was sufficiently transfused with five units of blood and two units of fresh frozen plasma. During the subsequent 1 year follow - up, the functional and cosmetic result was excellent. Conclusion: A continuous loop - shaped suture ligation procedure along the base of the giant NF effectively reduced the amount of hemorrhage during the operation, made dissection and ligation of vessels easily and quickly, and shorten the operating time and postoperative recovery time.

Performance Evaluation and Economic Estimation of Ground Source Heat Pump Cooling and Heating System (지열 냉난방 시스템의 성능 및 경제성 평가)

  • Lim Hyo Jae;Song Yoon Seok;Kong Hyoung Jin;Park Seong Koo
    • Journal of Energy Engineering
    • /
    • v.13 no.4
    • /
    • pp.296-300
    • /
    • 2004
  • Performance evaluation and economic estimation were conducted on the water to water GSHP (Ground Source Heat Pump) installed in existing building. Ground heat exchanger was a closed vertical loop type and sized to be 5 boreholes and 100m depth per borehole. Operation efficiency of the system shows that, COP increased from 3.0 to 4.2 with entering water temperature in heating operation, however, COP decreased from 5.0 to 3.7 in cooling operation. Economic estimation was analyzed by LCC (Life Cycle Cost) method and it showed that GSHP could save 68% of cost compare to the conventional oil source. Thus, despite of the large amount of initial cost, GSHP has a economic advantage to the other energy sources.

Performance Analysis of Rotation-lock Differential Precoding Scheme (회전로크 구조의 차분 선부호화 기법의 성능 분석)

  • Kim, Young Ju
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.4
    • /
    • pp.9-16
    • /
    • 2013
  • Long term evolution (LTE) and LTE-Advanced (LTE-A) systems adopt closed-loop multiple-input multiple-output antenna techniques. Equal gain transmission which has equal gain property is the key factor in their codebook design. In this paper, a novel differential codebook structure which maintains the codebook design requirements of LTE or LTE-A systems. Especially, eight-phase shift keying (8-PSK) constellations are used as elements of codewords, which not only maintain equal gain property but also reduce the computation complexity of precoding and decoding function blocks. The equal gain property is very important to uplink because the performance of uplink is very sensitive to the peak-to-average power ratio (PAPR). Moreover, the operation of the proposed differential codebook is explained as a rotation-lock structure. As the results of computer simulations, the steady-state throughput performance of the proposed codebook shows at least 0.9dB of SNR better than those of the conventional LTE codebook with the same amount of feedback information.

Development of RTDS-MATLAB Integrated Simulation Environment for Development and Verification of Voltage Measurement based CVR Control Algorithm (전압계측기반 CVR제어 알고리즘 개발 및 검증을 위한 RTDS-MATLAB 연동 시뮬레이션 환경 개발)

  • Go, Seok-Il;Ahn, Seon-Ju;Choi, Joon-Ho;Nam-Koong, Won;Shin, Chang-Hoon
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.4
    • /
    • pp.549-556
    • /
    • 2016
  • CVR is a technique for reducing power consumption by reducing the voltage of the system and many demonstrations and studies have been conducted in the past. Recently, SCADA-based or AMI-based VVC have been developed and the CVR is used as an important operation mode. Using a variety of instruments, CVR determines the optimal VVC control references by closed loop control. In this paper, we implemented RTDS-MATLAB integrated simulation environment for development and verification of CVR control algorithm based on voltage measurement. The voltage control device of distribution system was modeled using RTDS and MATLAB has constructed a controller that can measure and control the voltage of the simulation system of RTDS. After the capacitor, which is a reactive power control device, flattens the voltage of the system, the control algorithm reduces the voltage of the system by tap control of the OLTC based on the flatten voltage. The proposed system was verified by simulations.

Performance Evaluation of a Closed-Loop Pressure Retarded Membrane Distillation for Brackish Water Desalination and Power Generation (기수담수화와 전력 생산을 위한 폐루프형 압력 지연식 막 증류 공정의 성능 평가)

  • Cho, Gyu Sang;Lee, Jun-Seo;Park, Kiho
    • Korean Chemical Engineering Research
    • /
    • v.60 no.4
    • /
    • pp.525-534
    • /
    • 2022
  • In this study, we investigated the applicability and optimal operating strategy of a closed-loop pressure retarded membrane distillation (PRMD) for brackish water desalination. For effective operation with net power generation, high temperature of heat source over 90 ℃ and feed flow rate at 0.6 kg/s are recommended. At 3 g/L of feed concentration, the average permeate flux and net energy density showed 8.04 kg/m2/hr and 2.56 W/m2, respectively. The average permeate flux and net energy density were almost constant in the range of feed concentration from 1 to 3 g/L. Compared to the case with seawater feed, the PRMD with brackish water feed showed higher average permeate flux and net energy density. Thus, PRMD application using brackish water feed can be more effective than that using seawater feed in terms of power generation.

High-efficiency Operation of Switched Reluctance Generator based on Current Waveform Control

  • Li, Zhenguo;Yu, Siyang;Ahn, Jin-Woo
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.2 no.1
    • /
    • pp.120-126
    • /
    • 2013
  • The main aim of this paper is to expound high-efficiency operation of Switched Reluctance Generator (SRG) based on the current waveform. For this purpose, theoretical analysis of the copper loss and iron loss of the system is done first. Then, necessary simulation is done to find the variation trend of the copper loss and iron loss with the variation of the current waveform at the same output power. Finally, the best current waveform which can make the system operate with high efficiency is obtained by considering the influence of these two kinds of loss. In order to verity the simulation results, the experimental platform of DC motor-SRG is built and the modified angle position control (APC) method which can specify the current shape optionally is presented. By comparing the system efficiency at the three kinds of typical current waveform, the correctness and feasibility of the theory is verified. The proposed method is simple, reliable, and easy to achieve.

Open-Loop Pipeline ADC Design Techniques for High Speed & Low Power Consumption (고속 저전력 동작을 위한 개방형 파이프라인 ADC 설계 기법)

  • Kim Shinhoo;Kim Yunjeong;Youn Jaeyoun;Lim Shin-ll;Kang Sung-Mo;Kim Suki
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.1A
    • /
    • pp.104-112
    • /
    • 2005
  • Some design techniques for high speed and low power pipelined 8-bit ADC are described. To perform high-speed operation with relatively low power consumption, open loop architecture is adopted, while closed loop architecture (with MDAC) is used in conventional pipeline ADC. A distributed track and hold amplifier and a cascading structure are also adopted to increase the sampling rate. To reduce the power consumption and the die area, the number of amplifiers in each stage are optimized and reduced with proposed zero-crossing point generation method. At 500-MHz sampling rate, simulation results show that the power consumption is 210mW including digital logic with 1.8V power supply. And the targeted ADC achieves ENOB of about 8-bit with input frequency up to 200-MHz and input range of 1.2Vpp (Differential). The ADC is designed using a $0.18{\mu}m$ 6-Metal 1-Poly CMOS process and occupies an area of $900{\mu}m{\times}500{\mu}m$

Trajectory Control of Excavator Actuators Using IMV (IMV를 이용한 굴착기 작업장치 궤적제어)

  • Jung, Gyuhong
    • Journal of Drive and Control
    • /
    • v.17 no.2
    • /
    • pp.45-54
    • /
    • 2020
  • The IMV is a combination of four two-way valve systems which replace a conventional four-way spool valve to improve efficiency mostly in excavator hydraulics. As the environmental regulations for construction equipment have tightened, some overseas advanced companies have released commercial excavators in which the MCV is implemented with the IMVs. Development of the IMV type MCV relies on the control algorithm as well as the robust performance of proportional flow control valves. In this study, the IMV controller was designed and verified with experiments for the excavator working unit, which determines the IMV mode of operation and the extent of the valve opening in consideration of the load conditions on hydraulic actuators. First, the open-loop controller was designed with a joystick command vs. a PSV reference current map comprising several control parameters in to compensate for the different flow characteristics and non-linearities of two-way flow control valves. Second, the closed-loop controller was designed with the PI control fed by the actuator displacement and outputs actuator percent effort equivalent to the operator's joystick command. Finally, the performance of the IMV type MCV was verified with the trajectory control of position references derived from the energy consumption test standard. Experimental results showed the control performance of the IMV developed in this study, and suggest that future studies to be conducted to advance technical progress.

Digital Phase-Locked Loop(DPLL) Technique for UPS (무정전 전원장치용 디지털 위상동기화 기법)

  • 김제홍;최재호
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.11 no.3
    • /
    • pp.106-113
    • /
    • 1997
  • In uninterruptible power supply(UPS), a high speed phase control is usually required to compensate transients in the output voltage at the instant of transfer from the ac line to the inverter when the ac line fails or backs to the ac line in case of the inverter fails. To overcome this problem, this paper pre¬sents the closed digital phase-locked loop(DPLL) techniques designed by full software with TMS320C31 digital signal processor and describes the functional operation of the proposed DPLL. Fi¬nally, the performance of the proposed DPLL is shown and discussed through simulation and experiment.