• 제목/요약/키워드: Closed circuit potential

검색결과 16건 처리시간 0.026초

Investigation of buckling behavior of functionally graded piezoelectric (FGP) rectangular plates under open and closed circuit conditions

  • Ghasemabadian, M.A.;Kadkhodayan, M.
    • Structural Engineering and Mechanics
    • /
    • 제60권2호
    • /
    • pp.271-299
    • /
    • 2016
  • In this article, based on the higher-order shear deformation plate theory, buckling analysis of a rectangular plate made of functionally graded piezoelectric materials and its effective parameters are investigated. Assuming the transverse distribution of electric potential to be a combination of a parabolic and a linear function of thickness coordinate, the equilibrium equations for the buckling analysis of an FGP rectangular plate are established. In addition to the Maxwell equation, all boundary conditions including the conditions on the top and bottom surfaces of the plate for closed and open circuited are satisfied. Considering double sine solution (Navier solution) for displacement field and electric potential, an analytical solution is obtained for full simply supported boundary conditions. The accurate buckling load of FGP plate is presented for both open and closed circuit conditions. It is found that the critical buckling load for open circuit is more than that of closed circuit in all loading conditions. Furthermore, it is observed that the influence of dielectric constants on the critical buckling load is more than those of others.

Stability analysis of transversely isotropic laminated Mindlin plates with piezoelectric layers using a Levy-type solution

  • Ghasemabadian, M.A.;Saidi, A.R.
    • Structural Engineering and Mechanics
    • /
    • 제62권6호
    • /
    • pp.675-693
    • /
    • 2017
  • In this paper, based on the first-order shear deformation plate theory, buckling analysis of piezoelectric coupled transversely isotropic rectangular plates is investigated. By assuming the transverse distribution of electric potential to be a combination of a parabolic and a linear function of thickness coordinate, the equilibrium equations for buckling analysis of plate with surface bonded piezoelectric layers are established. The Maxwell's equation and all boundary conditions including the conditions on the top and bottom surfaces of the plate for closed and open circuited are satisfied. The analytical solution is obtained for Levy type of boundary conditions. The accurate buckling load of laminated plate is presented for both open and closed circuit conditions. From the numerical results it is found that, the critical buckling load for open circuit is more than that of closed circuit in all boundary and loading conditions. Furthermore, the critical buckling loads and the buckling mode number increase by increasing the thickness of piezoelectric layers for both open and closed circuit conditions.

뇌보호설비용 인하도선의 설치조건에 따른 전위상승 (Potential Rises of Down-conductor for Lightning Protection System according to Establishment Conditions)

  • 이복희;강성만;이승칠;이동문;안창환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1724-1726
    • /
    • 2001
  • This paper deals with the characteristics of the potential rises of down-conductor due to lightning surge currents. Direct lightning strikes can cause high impulse currents to the lightning protection system(LPS) of a building. These high impulse currents have the front time as short as 1[${\mu}s$]. In this case, the induced voltages caused in a closed circuit inside the building can be very high and cause damage or submit people to electric hazard. So, the LPS has to be designed to ensure safety condition to person and acceptable levels of induced voltages to the electrical and electronic equipments. The results of the potential rises related to the bonding conditions between the grounding conductor and metal raceway and the type of down-conductors are introduced.

  • PDF

센서 모듈과 인공신경망을 활용한 실시간 반려견 행동 분석 및 케어 시스템 (Real-time Dog Behavior Analysis and Care System Using Sensor Module and Artificial Neural Network)

  • 이희래;김선경;이형규
    • 한국산업정보학회논문지
    • /
    • 제29권4호
    • /
    • pp.35-42
    • /
    • 2024
  • 본 연구에서는 움직임 센서 모듈과 딥러닝을 활용하여 반려견의 행동을 실시간으로 인식하고 분석하는 방법을 제안한다. 일반적으로 반려견의 행동을 파악하는 홈 CCTV(Closed-Circuit Television)는 개인의 사생활 보호 문제와 보안 이슈가 있어 이를 극복하기 위한 새로운 기술의 필요성이 제기되고 있다. 본 논문에서는 움직임 센서에서 측정되는 데이터를 기반으로 반려견의 행동을 분석하고 케어할 수 있는 시스템을 제안한다. 본 연구에서는 MLP(Multi-Layer Perceptron)와 CNN(Convolutional Neural Network) 모델을 비교하여 반려견 행동 분석에 적합한 모델을 선정하고 최적화를 하였으며, 실험 결과, 제안된 MLP 모델은 평균 82.19%의 정확도를 보이는 것을 확인하였으며, 모델 경량화를 통해 임베디드 환경에서 효율적으로 활용될 수 있음을 확인하였다.

유압 트랜스포머를 이용한 유압 실린더의 에너지 절감에 관한 연구 (A Study on Energy Saving Hydraulic Cylinder System Using Hydraulic Transformer)

  • 이민수;조용래;윤홍수;안경관
    • 한국정밀공학회지
    • /
    • 제25권2호
    • /
    • pp.49-56
    • /
    • 2008
  • In order to reduce energy consumption, secondary controlled system has been applied to many types of equipments. In lifting equipments or press machines using hydraulic cylinder, a hydraulic transformer is used as a control component instead of a valve for motion control and a component for recovering potential energy of load. The transformer is a combination of a variable displacement pump/motor as a secondary controlled element and a fixed displacement pump/motor. In this paper the effect of transformer is studied. Multiple closed loop controllers with displacement feedback of variable pump/motor, speed feedback and position feedback of cylinder are used. The efficiency and energy consumption when cylinder is driven up and down is calculated by simulation. Simulation results show that considerable energy saving is achieved by choosing load ratio, circuit type and supply pressure.

Accurate Formulas for Frequency-Dependent Resistance and Inductance Per Unit Length of On-Chip Interconnects on Lossy Silicon Substrate

  • Ymeri, H.;Nauwelaers, B.;Maex, K.;Roest, D.De;Vandenberghe, S.;Stucchi, M.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제2권1호
    • /
    • pp.1-6
    • /
    • 2002
  • A new closed-form expressions to calculate frequency-dependent distributed inductance and the associated distributed series resistance of single interconnect on a lossy silicon substrate (CMOS technology) are presented. The proposed analytic model for series impedance is based on a self-consistent field method and the vector magnetic potential equation. It is shown that the calculated frequency-dependent distributed inductance and the associated resistance are in good agreement with the results obtained from rigorous full wave solutions and CAD-oriented equivalent-circuit modeling approach.

무부하 충전케이블 개방시 잔류전압에의한 과전압계전기 동작현상 연구 (A Study of Over Voltage Ground Relay Operation Status at Opening of No-load Charged Cable)

  • 김영한;최종혁;윤기섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.185-187
    • /
    • 2000
  • Fault current is flowed into 154/23kV M. Tr when line-to-ground fault occurs in power system. NGR(Neutral Grounded Reactor) is set up in order to prevent M.Tr fault by limiting magnitude of fault currents. Here, disconnection of NGR causes voltage increase by L-C resonance and line-to-ground fault in an unearthed system results in voltage increase at healthy phases. So Over Voltage Ground Relay(OVGR) is used for tripping M.Tr. Also, buses at second phases of M.Trs are all connected with section circuit breakers closed for the purpose of parallel operation and load shedding. In case of speciality buses are comprised of power cable in part for GIS connection. When no-load charged cable or bus is open by a section CB, unbalanced voltage charged on the bus is induced. Also discrepant opening time for circuit breakers on different phases gives rise to unbalanced zero sequence voltage. It was observed that this zero sequence voltage detected in the 22.9kV P.T (Potential Transformer for bus) mal-operated 59GT and tripped M.Tr. The zero sequence voltage of which vanishing time is longer than relay operating time came out by EMTDC simulation. Also, it was shown that the voltage waves of actual test are similar to those of simulation. On the basis of above results, R-C circuit complement on the relay without any effect on a power system made operating time of the relay longer than vanishing time of distorted waves. Consequently, operating time of the relay was delayed and magnitude of distorted waves was decreased by increasing time constant of the relay.

  • PDF

ZVS-FB PWM DC/DC 변환기의 동특성 해석 및 제어기 설계 (Dynamic Analysis and Control Loop Design of ZVS-FB PWM DC/DC Converter)

  • 이득기;윤길문;차영길;김흥근
    • 전력전자학회논문지
    • /
    • 제3권3호
    • /
    • pp.231-239
    • /
    • 1998
  • 본 논문에서는 대용량에 적합한 영전압 스위칭 전브리지 PWM 직류/직류 변한기의 동특성 해석과 제어 루프의 설계에 대해 논하였다. 전압을 제어하기 위한 위상전이제어의 효과와 영전압 스위칭을 위한 변압기의 누설인덕턴스, FET의 적합 커패시턴스의 이용효과를 고려한 소신호 모델을 유도하였다. 이 소신호 모델은 PWM 벅 변환기의 등가모델에 시비율 변조에 대한 두 개의 종속 전원을 추가함으로써 모델링할 수 있다. 소신호 해석 결과를 근거로 하여 2-극점, 1-영점 보상회로를 사용한 전압제어기를 설계하였다. 설계된 제어기의 타당성을 검증하기 위해서 개루프 시스템과 폐루프 시스템의 소신호 해석결과를 비교하였으며, 2kW급 부하실험으로 설계한 전압제어기의 동특성이 우수함을 실험적으로 입증하였다.

  • PDF

Coupled electro-elastic analysis of functionally graded piezoelectric material plates

  • Wu, Chih-Ping;Ding, Shuang
    • Smart Structures and Systems
    • /
    • 제16권5호
    • /
    • pp.781-806
    • /
    • 2015
  • A unified formulation of finite layer methods (FLMs), based on the Reissner mixed variational theorem (RMVT), is developed for the three-dimensional (3D) coupled electro-elastic analysis of simply-supported, functionally graded piezoelectric material (FGPM) plates with open- and closed-circuit surface conditions and under electro-mechanical loads. In this formulation, the material properties of the plate are assumed to obey an exponent-law varying exponentially through the thickness coordinate, and the plate is divided into a number of finite rectangular layers, in which the trigonometric functions and Lagrange polynomials are used to interpolate the in- and out-of-plane variations of the primary field variables of each individual layer, respectively, such as the elastic displacement, transverse shear and normal stress, electric potential, and normal electric displacement components. The relevant orders used for expanding these variables in the thickness coordinate can be freely chosen as the linear, quadratic and cubic orders. Four different mechanical/electrical loading conditions applied on the top and bottom surfaces of the plate are considered, and the corresponding coupled electro-elastic analysis of the loaded FGPM plates is undertaken. The accuracy and convergence rate of the RMVT-based FLMs are assessed by comparing their solutions with the exact 3D piezoelectricity ones available in the literature.

유압 트랜스포머를 이용한 유압 실린더의 에너지 절감에 관한 연구 (A study of Energy Saving Hydraulic Cylinder System Using Hydraulic Transformer)

  • 안경관;이민수;조용래;윤주현;조우근;윤홍수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.1075-1080
    • /
    • 2007
  • In order to reduce energy consumption, secondary controlled system has been applied to many types of equipments. In lifting equipments or press machines using hydraulic cylinder, a hydraulic transformer is used as a control component instead of a valve for motion control and a component for recovering potential energy of load. The transformer is a combination of a variable displacement pump/motor as a secondary controlled element and a fixed displacement pump/motor. In this paper the effect of transformer is studied. Multiple closed loop controllers with displacement feedback of variable pump/motor, speed feedback and position feedback of cylinder are used. The efficiency and energy consumption when cylinder is driven up and down is calculated by simulation. Simulation results show that considerable energy saving is achieved by choosing load ratio, circuit type and supply pressure.

  • PDF