• Title/Summary/Keyword: Close loop

Search Result 171, Processing Time 0.022 seconds

Development of Remote Control System for KNUO 16 (공주대학교 천문대 16인치 반사망원경의 원격 제어 시스템 구축)

  • Kim, Chil-Young;Chung, Jung-In;Kim, Jong-Hun;Kim, Hyouk;Jang, Bi-Ho;Kim, Hee-Soo
    • Journal of the Korean earth science society
    • /
    • v.24 no.5
    • /
    • pp.456-466
    • /
    • 2003
  • We developed a remote control system for the 16" reflecting telescope at KNUO (Kongiu National University Observatory). This system is a close loop system. The electronic control part used TCS-196 of the Korea Astronomy Observatory, the mechanical part was developed directly in this research. The pointing accuracy of this system was ${\pm}$50" in the hour angle direction, ${\pm}$40" in the declination direction after mount modeling. The tracking accuracy was about 1"/min. This pilot test result means that this system is suitable for research or education of astronomical fields.

Experience with Enterostomy Closure in Very Low Birth Weight Infants (극소 저출생 체중아에서 조성한 장루의 복원 경험)

  • Shin, Hee-Chul;Moon, Suk-Bae;Lee, Seong-Cheol;Jung, Sung-Eun;Park, Kwi-Won
    • Advances in pediatric surgery
    • /
    • v.15 no.1
    • /
    • pp.18-26
    • /
    • 2009
  • The survival of Very Low Birth Weight (VLBW) infants has been improved with the advancement of neonatal intensive care. However, the incidence of accompanying gastrointestinal complications such as necrotizing enterocolitis has also been increasing. In intestinal perforation of the newborn, enterostomy with or without intestinal resection is a common practice, but there is no clear indication when to close the enterostomy. To determine the proper timing of enterostomy closure, the medical records of 12 VLBW infants who underwent enterostomy due to intestinal perforation between Jan. 2004 and Jul. 2007 were reviewed retrospectively. Enterostomy was closed when patients were weaned from ventilator, incubator-out and gaining adequate body weight. Pre-operative distal loop contrast radiographs were obtained to confirm the distal passage and complete removal of the contrast media within 24-hours. Until patients reached oral intake, all patients received central-alimentation. The mean gestational age of patients was $26^{+2}$ wks ($24^{+1}{\sim}33^{+0}$ wks) and the mean birth weight was 827 g (490~1450 g). The mean age and the mean body weight at the time of enterostomy formation were 15days (6~38 days) and 888 g (590~1870 g). The mean body weight gain was 18 g/day (14~25 g/day) with enterostomy. Enterostomy closure was performed on the average of 90days (30~123 days) after enterostomy formation. The mean age and the mean body weight were 105 days (43~136 days) and 2487 g (2290~2970 g) at the time of enterostomy closure. The mean body weight gain was 22 g/day after enterostomy closure. Major complications were not observed. In conclusion, the growth in VLBW infants having enterostomy was possible while supporting nutrition with central-alimentation and the enterostomy can be closed safely when the patient's body weights is more than 2.3 kg.

  • PDF

Fresh Produce Container Operated with a Routine of Hypobaric Application, CO2 Injection and Diffusion Tube Opening for Keeping Beneficial Modified Atmosphere

  • Park, Su Yeon;An, Duck Soon;Lee, Dong Sun
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.26 no.2
    • /
    • pp.53-60
    • /
    • 2020
  • A concept of household container to create and keep the modified atmosphere (MA) beneficial for fresh produce mix was devised and tested under typical chilled storage conditions of 3℃. The container system containing mixed products is initialized by applying weak hypobaric condition (0.9 atm) and subsequently injecting CO2 gas at an appropriate low level (0.03 atm). The passive atmosphere modification by produce respiration is then induced to reach a target until gas diffusion tube of proper dimension starts to open. The design was made to attain quasi-steady state mass balance of O2, CO2 and N2 to maintain the desired MA through the storage. Interrupted opening for taking out or placing some products was to reinitialize the loop of control logic. The developed concept was tested by the container which held commodities of spinach, pak choi, oyster mushroom, peeled onion, strawberry and cut carrot. The target optimum MA of 11% O2 and 10% CO2 (0.11 and 0.10 atm, respectively) was set to avoid injurious range of O2 and CO2 concentrations for any commodities. The developed container system could work to reach and maintain beneficial MA of 0.10-0.12 atm O2 and 0.07-0.10 atm CO2 close to the target during the storage contributing to quality retention of products measured in weight loss, chlorophyll content of spinach, ascorbic acid content of pak choi, color of onion, texture of oyster mushroom, bacterial count of strawberry and carotenoids of carrot. The container system shows potential to improve current preservation practice of fresh produce mix on consumers' level.

Lyapunov-based Semi-active Control of Adaptive Base Isolation System employing Magnetorheological Elastomer base isolators

  • Chen, Xi;Li, Jianchun;Li, Yancheng;Gu, Xiaoyu
    • Earthquakes and Structures
    • /
    • v.11 no.6
    • /
    • pp.1077-1099
    • /
    • 2016
  • One of the main shortcomings in the current passive base isolation system is lack of adaptability. The recent research and development of a novel adaptive seismic isolator based on magnetorheological elastomer (MRE) material has created an opportunity to add adaptability to base isolation systems for civil structures. The new MRE based base isolator is able to significantly alter its shear modulus or lateral stiffness with the applied magnetic field or electric current, which makes it a competitive candidate to develop an adaptive base isolation system. This paper aims at exploring suitable control algorithms for such adaptive base isolation system by developing a close-loop semi-active control system for a building structure equipped with MRE base isolators. The MRE base isolator is simulated by a numerical model derived from experimental characterization based on the Bouc-Wen Model, which is able to describe the force-displacement response of the device accurately. The parameters of Bouc-Wen Model such as the stiffness and the damping coefficients are described as functions of the applied current. The state-space model is built by analyzing the dynamic property of the structure embedded with MRE base isolators. A Lyapunov-based controller is designed to adaptively vary the current applied to MRE base isolator to suppress the quake-induced vibrations. The proposed control method is applied to a widely used benchmark base-isolated structure by numerical simulation. The performance of the adaptive base isolation system was evaluated through comparison with optimal passive base isolation system and a passive base isolation system with optimized base shear. It is concluded that the adaptive base isolation system with proposed Lyapunov-based semi-active control surpasses the performance of other two passive systems in protecting the civil structures under seismic events.

Replication origins oriGNAI3 and oriB of the mammalian AMPD2 locus nested in a region of straight DNA flanked by intrinsically bent DNA sites

  • Balani, Valerio Americo;De Lima Neto, Quirino Alves;Takeda, Karen Izumi;Gimenes, Fabricia;Fiorini, Adriana;Debatisse, Michelle;Fernandez, Maria Aparecida
    • BMB Reports
    • /
    • v.43 no.11
    • /
    • pp.744-749
    • /
    • 2010
  • The aim of this work was to determine whether intrinsically bent DNA sites are present at, or close to, the mammalian replication origins oriGNAI3 and oriB in the Chinese hamster AMPD2 locus. Using an electrophoretic mobility shift assay and in silico analysis, we located four intrinsically bent DNA sites (b1 to b4) in a fragment that contains the oriGNAI3 and one site (b5) proximal to oriB. The helical parameters show that each bent DNA site is curved in a left-handed superhelical writhe. A 2D projection of 3D fragment trajectories revealed that oriGNAI3 is located in a relatively straight segment flanked by bent sites b1 and b2, which map in previously identified Scaffold/Matrix Attachment Region. Sites b3 and b4 are located approximately 2 kb downstream and force the fragment into a strong closed loop structure. The b5 site is also located in an S/MAR that is found just downstream of oriB.

A Brief Review of Approaches Using Planktonic Organisms to Assess Marine Ecosystem Health (부유생물을 이용한 해양생태계 건강성 평가)

  • Kim, Young-Ok;Choi, Hyun-Woo;Jang, Min-Chul;Jang, Pung-Kuk;Lee, Won-Je;Shin, Kyoung-Soon;Jang, Man
    • Ocean and Polar Research
    • /
    • v.29 no.4
    • /
    • pp.327-337
    • /
    • 2007
  • Plankton communities have close relationships with environmental changes in water columns. Thus, the use of plankton as a biological tool for assessing the marine ecosystem health may be effective. Major issue regarding coastal pollution has been usually recognized as phytoplankton blooms or red tides caused by the eutrophication, an increase in concentration of inorganic nutrients such as nitrogen and phosphorus. However, in order to understand the effects of the overall pollution on marine ecosystem, the organic pollutants as well as the inorganic nutrients should be also considered. For understanding the effects of the organic pollution, among the planktonic organisms, heterotrophic bacteria, heterotrophic flagellates and ciliates should be investigated. Generally, there are three approaches for assessing the marine ecosystem health using the plankton taxa or plankton communities. The first one is a community-based approach such as diversity index and chlorophyll a concentration which are common in analysis of the plankton communities. The second is an indiviual-based approach which is to monitor the pollution indicative species. This approach needs one's ability to identify the plankton to species level. The last approach is a bioassay of toxicity, which can be applied to the plankton. A pilot study in Masan Bay was conducted to assess the effects of the inorganic and organic pollution. In this article, a new approach using plankton communities was tentatively presented as a biological tool for assessing the ecosystem health of Masan Bay.

A Study on the Thermal-Hydraulic Characteristics of Molten Salt in Minichannels of an Intermediate Heat Exchanger for a Very High Temperature Reactor (VHTR) (초고온원자로 중간열교환기 미니챈널에서의 Molten Salt 열수력 특성 연구)

  • Jeong, Hui-Seong;Hwang, In-Seon;Bang, Kwang-Hyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.12
    • /
    • pp.1093-1099
    • /
    • 2010
  • For Very High Temperature Reactors (VHTR), the designs of the Intermediate Heat Transport Loop (IHTL) and the Intermediate Heat Exchanger (IHX) are particularly difficult because of the high-temperature operation (up to $950^{\circ}C$). In this study, Flinak molten salt, a eutectic mixture of LiF, NaF, and KF (46.5:11.5:42.0 mole %) is considered as the heat transporting fluid in the IHTL. To evaluate the flow and heat transfer performance of the Flinak molten salt in small channels with hydraulic diameters in the millimeter range, a double-pipe heat exchanger was constructed using small-diameter tubes for the heat exchange between the Flinak and the gas flow. The experimental data showed that, for laminar Flinak flow, the measured friction factors were close to the 64/Re curve and the Nusselt numbers were generally between 3.66 and 4.36.

SBAS SIGNAL SYNCHRONIZATION

  • Kim, Gang-Ho;Kim, Do-Yoon;Lee, Taik-Jin;Kee, Changdon
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.1
    • /
    • pp.309-314
    • /
    • 2006
  • In general DGPS system, the correction message is transferred to users by wireless modem. To cover wide area, many DGPS station should be needed. And DGPS users must have a wireless modem that is not necessary in standalone GPS. But SBAS users don't need a wireless modem to receive DGPS corrections because SBAS correction message is transmitted from the GEO satellite by L1 frequency band. SBAS signal is generated in the GUS(Geo Uplink Subsystem) and uplink to the GEO satellite. This uplink transmission process causes two problems that are not existed in GPS. The one is a time delay in the uplink signal. The other is an ionospheric problem on uplink signal, code delay and carrier phase advance. These two problems cause ranging error to user. Another critical ranging error factor is clock synchronization. SBAS reference clock must be synchronized with GPS clock for an accurate ranging service. The time delay can be removed by close loop control. We propose uplink ionospheric error correcting algorithm for C/A code and carrier. As a result, the ranging accuracy increased high. To synchronize SBAS reference clock with GPS clock, I reviewed synchronization algorithm. And I modified it because the algorithm didn't consider doppler that caused by satellites' dynamics. SBAS reference clock synchronized with GPS clock in high accuracy by modified algorithm. We think that this paper will contribute to basic research for constructing satellite based DGPS system.

  • PDF

Automatic Detection of Vehicle Area Rectangle and Traffic Volume Measurement through Vehicle Sub-Shadow Accumulation (차량 그림자 누적을 통한 검지 영역 자동 설정 및 교통량 측정 방법)

  • Kim, Jee-Wan;Lee, Jaesung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.8
    • /
    • pp.1885-1894
    • /
    • 2014
  • There are various high-performance algorithms in the area of the existing VDSs (vehicle detection systems). However, they requires a large amount of computational time-complexity and their systems generally are very expensive and consumes high-power. This paper proposes real-time traffic information detection algorithm that can be applied to low-cost, low-power, and open development platform such as Android. This algorithm uses a vehicle's sub-shadow to set ROI(region of interest) and to count vehicles using a location of the sub-shadow and the vehicle. The proposed algorithm is able to count the vehicles per each roads and each directions separately. The experiment result show that the detection rate for going-up vehicles is 94.1% and that for going-down vehicles is 97.1%. These results are close to or surpasses 95%, the detection rate of commercial loop detectors.

Axial compressive behavior of concrete-encased CFST stub columns with open composite stirrups

  • Ke, Xiaojun;Ding, Wen;Liao, Dingguo
    • Advances in concrete construction
    • /
    • v.12 no.5
    • /
    • pp.399-409
    • /
    • 2021
  • The existing method to improve the coordination performance of the inner and outer parts of concrete-encased concrete-filled steel tube (CFST) composite columns by increasing the volume-stirrup ratio causes difficulties in construction due to over-dense stirrups. Thus, this paper proposes an open polygonal composite stirrup with high strength and high ductility CRB600H reinforced rebar, and seventeen specimens were constructed, and their axial compressive performance was tested. The main parameters considered were the volume-stirrup ratio, the steel tube size, the stirrup type and the stirrup strength. The test results indicated: For the specimens restrained by open octagonal composite stirrups, compared with the specimen of 0.5% volume-stirrup ratio, the compressive bearing capacity increased by 14.6%, 15.7% and 21.5% for volume-stirrup ratio of 0.73%, 1.07% and 1.61%, respectively. For the specimens restrained by open composite rectangle stirrups, compared with the specimen of 0.79% volume-stirrup ratio, the compressive bearing capacity increased by 7.5%, 6.1%, and -1.4% for volume-stirrup ratio of 1.12%, 1.58% and 2.24%, respectively. The restraint ability and the bearing capacity of the octagonal composite stirrup are better than other stirrup types. The specimens equipped with open polygonal composite stirrup not only had a higher ductility than those with the traditional closed-loop stirrup, but they also had a higher axial bearing capacity than those with an HPB300 strength grades stirrup. Therefore, the open composite stirrup can be used in practical engineering. A new calculation method was proposed based on the stress-strain models for confined concrete under different restrain conditions, and the predicted value was close to the experimental value.