Aerosol Filtration/Sampling Device Based on Irrigated Rotating Wires

  • ;;이규원
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 2000년도 추계학술대회 논문집
    • /
    • pp.265-267
    • /
    • 2000
  • The objective of this study is to analyze, design and evaluate a new gas cleanup or sampling system that will remove erosive, corrosive, and fouling contaminants present in an effluent stream as either solid or liquid particles providing a clean gas stream. The gas clean-up or sampling system considered in this study is an irrigated, rotating element device. The device consists of a central disk-like hub from which emanate radially wires or cylindrical elements. (omitted)

  • PDF

환경대기 중 프탈레이트 화합물의 농도 측정 (II) - 실험재료 전처리 및 시료정제과정 평가 - (Determination of Phthalates Compounds in the Ambient Atmosphere (II) - Evaluation of Experimental Artifacts and Sample Clean-up Procedures -)

  • 박영화;황윤정;서영교;백성옥
    • 대한환경공학회지
    • /
    • 제32권5호
    • /
    • pp.455-460
    • /
    • 2010
  • 본 연구에서는 프탈레이트 화합물 측정 시 시료채취 및 분석과정 증에서 야기될 수 있는 공시료의 오염여부를 평가하고 clean-up 절차와 같은 적절한 개선 방안을 제시하였다. 실험도구 및 시료채취 매체에 대한 공시료를 평가한 결과 많은 종류의 실험기구 및 장치에서 DBP와 DEHP가 잔존하는 것으로 나타났다. 따라서 실험도구는 반드시 전처리하여 사용해야 하며, 이후 공시료 보정이 수반되어야 한다. 또한 본 연구에서 제시한 clean-up 방법을 통해 불순물이 많이 제거되었으며, GC/MS를 이용한 정성?정량분석에서 정도개선에 효과적인 것으로 나타났다.

원료돈육의 오염원 추적 및 위생기준 설정에 관한 연구 (Study on Pursuit of Contamination Sources and Establishment of Sanitary Standard from Raw Pork Meat)

  • 임대석;강희곤;김용곤;김창한
    • 한국축산식품학회지
    • /
    • 제21권2호
    • /
    • pp.149-155
    • /
    • 2001
  • The aims of this study were to examine contamination sources and provide the basic data in establishment of sanitary standard for raw pork meat. From \"Random sampling(I)\", initial total plate counts of post-slaughter samples for the group A, B and C were 1.5${\times}10^4$cfu/$textrm{cm}^2$, 5.5${\times}10^5$cfu/$textrm{cm}^2$ and 1.8${\times}10^4$cfu/$textrm{cm}^2$, respectively, and of post-prechilling samples for the group A, B and C were 1.0${\times}10^4$cfu/$textrm{cm}^2$, 4.6${\times}10^5$cfu/$textrm{cm}^2$ and 2.5${\times}10^4$cfu/$textrm{cm}^2$, respectively. Initial total plate counts of post-transportation samples for the group D, E and F did not increased, as did the group A, B and C. From \"Normal sampling(II)\", initial total plate counts of post-slaughter, post-prechilling, post-transportation and post-2 days preservation samples were 7.3${\times}10^4$cfu/$textrm{cm}^2$, 9.6${\times}10^4$cfu/$textrm{cm}^2$, 2.0${\times}10^5$cfu/$textrm{cm}^2$ and 2.5${\times}10^5$cfu/$textrm{cm}^2$, respectively. From \"Clean sampling(III)\", initial total plate counts of post-slaughter, post-prechilling, post-transportation and post-2 days preservation samples were decreased to 7.0${\times}10^2$cfu/$textrm{cm}^2$, 7.5${\times}10^2$cfu/$textrm{cm}^2$, 8.5${\times}10^2$cfu/$textrm{cm}^2$ and 5.5${\times}10^3$cfu/$textrm{cm}^2$, respectively, compared with "Normal sampling(II)". No E. coli O157:H7, Staphylococcus aureus and Salmonella were detected at each sampling step. Consequently, a slaughter method like "Clean sampling(III)" showed a better sanitary effect to low total plate counts of 10$^2$∼10$^3$times, compared with "Normal sampling(II)". The one of contamination sources for raw pork meat was at a slaughtering step, and "Clean sampling" method may be considered as the one of sanitary standards.

  • PDF

고정 오염원의 연소과정에서 발생하는 먼지를 측정하기 위한 희석방법 연구동향 (Dilution methods for combustion aerosol measurement from stationary emission sources: A review)

  • 우창규;김학준;김용진;한방우;강수지;천성남
    • 한국입자에어로졸학회지
    • /
    • 제13권4호
    • /
    • pp.165-172
    • /
    • 2017
  • For precise particle measurements in combustion environments, various dilution sampling methods were compared. Dilution equipments using dilution tunnels and hot/cold dilution with porous tube dilutors were most frequently used so far. The combination of porous tube dilutor and ejector diluter has relatively small footprint, and it results in lower particle losses compared to other methods. To determine the portion of condensable particulate matter, proper temperature control and flow control is required.

대기 중 다환방향족 탄화수소의 측정을 위한 시료포집방법의 비교평가 (Evaluation of Sampling Methodology for the Measurement of Polycyclic Aromatic Hydrocarbons in the Atmosphere)

  • 백성옥;최진수
    • 한국대기환경학회지
    • /
    • 제14권1호
    • /
    • pp.43-62
    • /
    • 1998
  • This study was carried out to investigate the influence of different sampling methods on the measured concentrations of polycyclic aromatic hydrocarbons (PAH) both in the vapor and particulate phases, and to evaluate the effects of ambient temperature and sampling duration on the losses of PAH associated with particle samples due to volatilization. The experimental protocol of this study is consisted of two parts. The first part is related to the comparison of PAH concentrations measured by 4 different sampling systems, each of which involves different sampling principles for comparison purposes, including a medium-volume sampler with XAD-2 adsorbent, a high-volume sampler with polyurethane foam (PUF), two identical low-volume samplers: one with XAD-2 and the other with PUF, respectively. The second part of this study is to quantitatively estimate the losses of particulate PAH samples by volatilization during sampling, using two identical low-volume samplers: one was used for changing the filters every 3 hrs, 6 hrs, 12 hrs, and 24 hrs sampling, while the other was maintained for continuous 48 hours sampling without changing the filter. The concentrations of volatile PAH including 2-3 rings appeared to be significantly affected by the type of adsorbent. Measured levels of these lower-molecular weight PAH by XAD-2 adsorbent were much higher than those by PUF for both high-volume and low-volume sampling. PUF was found to give rise to unknown components that interfered with the PAH analysis, even after extensive clean-up. In addition, the retention efficiency of PUF for lower molecular weight PAH was subject to a large variation, being significantly influenced by sampling conditions such as ambient temperature. However, the effect of sampling methods with different adsorbents on the measured levels of semi-volatile compounds including 4 rings PAH such as fluoranthene, pyrene, BaA and chrysene, was not so much significant as more volatile PAH compounds. It was also clear from this study that volatilization losses of the semi-volatile PAH collected on the filters were inevitably occurred during prolonged sampling, and hence the results obtained from conventional sampling methods may not be expected to yield an accurate distribution of PAH between the vapor and particulate phases.

  • PDF

대기 유기질소화합물의 분석방법 및 농도 (Review on the Analytical Methods and Ambient Concentrations of Organic Nitrogenous Compounds in the Atmosphere)

  • 최나래;김용표
    • 한국대기환경학회지
    • /
    • 제34권1호
    • /
    • pp.120-143
    • /
    • 2018
  • The analytical methods and their ambient levels of organic nitrogenous compounds such as nitrosamines, nitramines (nitroamines), imines, amides and nitro-polycyclic aromatic hydrocarbons (nitro-PAHs) in the atmosphere are summarized and discussed. Sampling for the analysis of organic nitrogenous compounds was mostly conducted using high volume air sampler. The direct liquid extraction (DLE) using sonification and the pressurized liquid extraction (PLE) using the accelerated solvent extraction (ASE) have been frequently employed for the extraction of organic nitrogenous compounds in the atmospheric samples. After extraction, clean-up via filtration and the solid phase extraction (SPE) and concentrations using nitrogen and rotary evaporator have been generally conducted but in some studies the clean-up and concentration steps have been omitted to prevent the loss of analyte and improve the recovery rate of the analytical procedure. Instrumental analysis was mainly carried out using gas chromatography (GC) or the high performance liquid chromatography (HPLC) coupled with the single quadrupole mass spectrometer or tandem mass spectrometer in the electron ionization (EI), positive chemical ionization (PCI) and negative chemical ionization (NCI) mode and analysis sensitivity of nitrosamines and nitramines were higher in NCI mode. Desirable sampling and analysis methods for analyzing particulate organic nitrogenous compounds are suggested.

A Simple Proposition for Improving Industrial Hygiene Air Sampling Methods

  • Paik, Samuel Y.;Zalk, David M.
    • Safety and Health at Work
    • /
    • 제10권3호
    • /
    • pp.389-392
    • /
    • 2019
  • When conducting an exposure assessment, the primary goal of the industrial hygienist is to fully characterize the worker's exposure during a work shift to compare it with an occupational exposure limit. This applies regardless of the duration of the work activity as an activity that is relatively short in duration can still present exposure in excess of the occupational exposure limit even when normalized over an 8-hr shift. This goal, however, is often impeded by the specification of a minimum sample volume in the published sampling method, which may prevent the sample from being collected or submitted for analysis. Removing the specification of minimum sample volume (or adjusting it from a requirement to a recommendation), in contrast, allows for a broader assessment of jobs that consist of short-duration and high-exposure activities and also eliminates the unnecessary practice of running sampling pumps in clean air to collect a specified, minimum volume.

연약 점성토의 시료채취방법에 따른 시료교란도의 영향에 관한 연구 (A Study on the Disturbance Effects with Sampling Methods of Soft Clay)

  • 박춘식;장정욱;김종환
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.577-584
    • /
    • 2002
  • We have employed two methods to remove slime at the end of the sampler in clay layers. The first method is a sampling process that harnesses low pressure to clean up the ground around the sampler tip. The second method, in consideration of a disturbed layer, involves a technique of inserting the sampler 50 cm deep into the ground before cleaning up the verge of the sampler by using high pressure. Physical and mechanical properties of these two methods have been compared and analyzed to investigate how different sampling methods affect degree of disturbance. The first method shows little disturbance since the unconfined compression test results in quite greater E$\_$50//q$\_$u/ in the first method than in the second method. On the other hand, the consolidation test results in a slightly greater compression index in the second method than in the first method, when their indexes are compared in the same depth. This suggests that the second method demonstrates less disturbance than the first method does. It is assumed that the second method may reduce disturbance slightly, However, we suspect that choosing any of the two methods would not obtain a considerable difference in sampling.

  • PDF

대기 중 다환방향족탄화수소 측정방법의 성능평가 - 하이볼륨 샘플링 및 GC/MS 분석방법을 대상으로 (Evaluation of a Method for the Measurement of PAHs in the Ambient Atmosphere - Focusing on High Volume Sampling and GC/MS Analysis)

  • 서영교;박대권;백성옥
    • 한국환경보건학회지
    • /
    • 제35권4호
    • /
    • pp.322-333
    • /
    • 2009
  • In this study, a measurement method was evaluated for the determination of polycyclic aromatic hydrocarbons (PAHs) in the ambient atmosphere. PAHs were sampled by high-volume samplers, and were then analysed with a GC/MS system. Particulate PAHs were collected on $8"{\times}10"$ quartz fiber filter, while vapor phase PAHs were adsorbed on polyurethane foam (PUF). Target compounds included a total of 36 PAHs, which are known to be frequently detected in the urban atmosphere. It was not necessary to clean-up samples before samples were analyzed using GC/MS, and the overall performance of the method was tested by a variety of quality control and quality assurance schemes. It is generally known that the clean-up procedure can negatively affect the recovery of samples. Precision and accuracy was evaluated using SRM provided by US NIST, and the results were generally satisfactory and reliable. However, the GC/MS method appeared not to be adequate for 6-rings PAHs, such as coronene, due to its lower sensitivity. In addition, collection efficiencies for low molecular compounds, such as 2-rings PAHs, were poor because of the lower retention volume of the PUF adsorbent. As a result, it was concluded that the method based on high-volume sampling and GC/MS analysis can give very reliable data by simultaneous sampling of both particulate and vapor phases for 3-rings to 5-rings PAHs of environmental concern.

환경대기중 다환방향족탄화수소의 포집과 분석방법에 관한 연구 (Evaluation of Sampling and Analytical Methods for the Determination of Polycyclic Aromatic Hydrocarbons in the Ambient Atmosphere)

  • 백성옥
    • 한국대기환경학회지
    • /
    • 제7권1호
    • /
    • pp.1-16
    • /
    • 1991
  • 본 연구에서는 대기중 저농도 수준의 다환방향족탄화수소(PAH) 농도를 측정하기 위하여 이들의 포집과 분석방법을 평가하였다. PAH의 포집매체로서 기체상은 Tenax 흡착제를, 입자상은 PTEE 및 유리섬유필터를 이용하였으며 양자 모두 저유량샘플러에 의해 포집되었다. 필터 및 흡착제에 함유된 유기성분은 Soxhlet 장치로 추출하였으며 신속하고도 간편한 Silica 미니칼럼을 이용하여 PAH 함유성분을 분리하였다. PAH 성분은 역상 HPLC로 분리되어 형광 및 UV 검출기로 검지하였다. 분석은 환경보건학적 중요성을 갖는 18개의 PAH에 대하여 행하여졌다. 분석방법의 타당성을 검토하기 위하여 추출능(시료의 회수율), 시료의 전처리단계, HPLC 분리능과 재현성 및 검출한계치 등이 평가되었으며 이울러 서로 다른 포집매체의 이용에 따른 회수율의 영향도 비교 검토되었다. 본 연구에서 채택된 포집 및 분석방법을 실제 환경시료에 적용하여 가스상 및 입자상 PAH 분석을 위한 실례를 제시하였다.

  • PDF