• Title/Summary/Keyword: Clean level test

Search Result 57, Processing Time 0.067 seconds

Design and Manufacturing of Clean Room Garments Required at Ultra Clean Environment - Based on comparative analysis of Particle Release- (고청정 작업환경에 적합한 방진복 디자인 개발 -파티클 발생량을 중심으로-)

  • 박상희;송명견
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.25 no.6
    • /
    • pp.1037-1045
    • /
    • 2001
  • This research is done to design and manufacture prototype clean room garments to improve the product yield of the clean room processing. To assist the research, other papers and references on the same subject were collected for analysis. Also the researcher made interviews with the workers at the clean room. The prototype garments made for this project was compared against the commercially available clean room garments used in the industry. A set of test was conducted to measure particle release from the garments. The prototype clean room garments was manufactured after having considered all the aspects stated above, and tested for the level of particle release. The test subjects performed 4 different movements(marching, arms stretch, squat and rise, and jogging) while wearing the prototype garments and commercially available clean room garments. Particle counts produced by each movement were measured. The data collected was statistically analyzed. The followings are the result of the test. 1) Overall, the prototype garments yielded less particle release.(p<0.001) 2) It showed greatest difference of particle counts for jogging(p<0.001) and squat and rise(p<0.001). In the arms stretch test. the prototype garments was also more effective in controling the particle, however, in the marching test. no significant difference was detected. 3) The prototype garments had less particle release in upper(p<0.001), middle(p< 0.001), and lower level(p<0.01) than the commercially available clean room garments. Manufacturing a new fabric for the clean room processing is important, but this research proves that the design of the clean room garments also determines the efficiency garments in the particle control. Therefore the same fabric can perform differently according to how it is designed. Improving the design will also improve the 7article control and reduce the cost of research. Eventually, the manufacturers will increase the product yield.

  • PDF

JAXA TechCLEAN Project

  • Futamura, Hisao;Hayashi, Shigeru
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.03a
    • /
    • pp.628-637
    • /
    • 2008
  • The JAXA's TechCLEAN project(2003-present) is summarized, with the interim technical achievements. TechCLEAN is collateral program with the NEDO engine project to accelerate R&D work of small passenger aircraft engine as well as to develop innovative environment technologies applicable to the future improvements. In the project NOx reduction, CO2 reduction and noise reduction are targeted. Component level researches and system demonstrator validation are planned with test facility renovation and demonstration base engines.

  • PDF

Analysis of Leakage Current Waveforms for Transmission Line Porcelain Insulators due to ESDD Contamination (ESDD 오손에 따른 송전용자기애자의 누설전류 파형의 분석)

  • Park, Jae-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.10
    • /
    • pp.1461-1470
    • /
    • 2012
  • This paper reports the contamination performance of transmission line porcelain insulators tested under five different contaminant conditions - clean and ESDD (equivalent salt deposit density) level (A, B, C, and D) through measurement of their leakage current under drop of potential method. To estimate the contamination for transmission line porcelain insulators, leakage current waveform and its maximum value were measured under step-up power test. In the clean insulators test, % distortion factors decreased with increasing step-up power, and as the ESDD level increased, some characteristics such as frequency analysis, harmonics and % distortion facotor could be used for contamination diagnosis of the transmission line porcelain insulators.

The Effect of an 8-weeks Velocity-based Training on Strength and Mechanical Power of Professional Athletes (8주간 속도 기반 트레이닝이 전문 운동선수의 근력과 근 파워 능력에 미치는 영향)

  • Jae Ho Kim;Sukhoon Yoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.34 no.1
    • /
    • pp.9-17
    • /
    • 2024
  • Objective: The purpose of this study is to apply 8-week velocity-based training to domestic professional athletes and the kinematic and kinetic analysis of the 1-RM improvement of back squat and power clean, which can represent strength-power ability, to verify the effectiveness of velocity-based training in Korea and to establish a basic basis. Method: The subjects who participated in this study were 10 professional athletes from K University (age: 21.40 ± 0.97 yrs., height: 179.90 ± 3.54 cm., body mass: 71.298 ± 2.98 kg). All subjects performed back squat and power clean 1-RM before and after 8-weeks of velocity-based training. A 3-dimensional motion analysis with 8 infrared cameras and 4 channels of EMG was performed in this study. A paired t-test was used for statistical verification. The significant level was set at α=.05. Results: Both Back squat and Power Clean 1-RM showed statistically significant increases (p<.05). In the case of back squat, there was no statistically significant difference in both kinematic and kinetic variables (p>.05). In the case of Power Clean, only the quadriceps of Phase 1 showed a statistically significant decrease (p<.05). Conclusion: Domestic professional athletes can improve their strength-power ability through velocity-based training, and such training for at least 8-weeks is considered a way to improve their performance.

R&D Status of NOx and Flue-gas Treatment Technologies in KIER (KIER의 NOx 및 연소배가스 처리기술 개발현황)

  • Min, Byoung-Moo;Choi, Sang-Il
    • 한국연소학회:학술대회논문집
    • /
    • 2003.05a
    • /
    • pp.295-300
    • /
    • 2003
  • In Korea, the emission standards for air pollutants will be more tighten from Jan. 2005. Especially, the new emission standards is focused on the nitrogen oxide. From this trend of standards, nitrogen oxide emission is hot issue in energy fields. Also, we have a new environmental problem, the carbon dioxide emission, which are related to the global warming. To solve the environmental problems, we must define the situation of clean-up technologies level in Korea and decide the direction of R&D for flue gas cleaning technologies. Now, this paper discus briefly on the De-NOx R&D activities and the large scale testing facility for flue gas clean-up technologies in Korea Institute of Energy Research. These discussions are contribute to the increasing of the R&D activities for flue gas clean-up technologies in Korea.

  • PDF

Multivariate analysis of the cleaning efficacy of different final irrigation techniques in the canal and isthmus of mandibular posterior teeth

  • Yoo, Yeon-Jee;Lee, WooCheol;Kim, Hyeon-Cheol;Shon, Won-Jun;Baek, Seung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.38 no.3
    • /
    • pp.154-159
    • /
    • 2013
  • Objectives: The aim of this study was to compare the cleaning efficacy of different final irrigation regimens in canal and isthmus of mandibular molars, and to evaluate the influence of related variables on cleaning efficacy of the irrigation systems. Materials and Methods: Mesial root canals from 60 mandibular molars were prepared and divided into 4 experimental groups according to the final irrigation technique: Group C, syringe irrigation; Group U, ultrasonics activation; Group SC, VPro StreamClean irrigation; Group EV, EndoVac irrigation. Cross-sections at 1, 3 and 5 mm levels from the apex were examined to calculate remaining debris area in the canal and isthmus spaces. Statistical analysis was completed by using Kruskal-Wallis test and Mann-Whitney U test for comparison among groups, and multivariate linear analysis to identify the significant variables (regular replenishment of irrigant, vapor lock management, and ultrasonic activation of irrigant) affecting the cleaning efficacy of the experimental groups. Results: Group SC and EV showed significantly higher canal cleanliness values than group C and U at 1 mm level (p < 0.05), and higher isthmus cleanliness values than group U at 3 mm and all levels of group C (p < 0.05). Multivariate linear regression analysis demonstrated that all variables had independent positive correlation at 1 mm level of canal and at all levels of isthmus with statistical significances. Conclusions: Both VPro StreamClean and EndoVac system showed favorable result as final irrigation regimens for cleaning debris in the complicated root canal system having curved canal and/or isthmus. The debridement of the isthmi significantly depends on the variables rather than the canals.

Determination of Phthalates Compounds in the Ambient Atmosphere (II) - Evaluation of Experimental Artifacts and Sample Clean-up Procedures - (환경대기 중 프탈레이트 화합물의 농도 측정 (II) - 실험재료 전처리 및 시료정제과정 평가 -)

  • Park, Young-Hwa;Hwang, Yoon-Jung;Seo, Young-Kyo;Baek, Sung-Ok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.5
    • /
    • pp.455-460
    • /
    • 2010
  • This study was carried out to find out any inherent problems occurring in the sampling and analytical procedures, and to suggest the relevant solutions to the problems. In addition, an optimal condition of clean-up process was developed, which was based on a method using silica glass column. As a result of experiments to test any artificial contamination of blank samples such as glassware and collection media, artifacts of DBP and DEHP appeared to be detected in various kinds of laboratory tools and apparatuses used in the sampling and analytical works. Therefore, it is necessary to investigate a degree of contamination before laboratory works by conducting a prior check any possible contaminations in all experimental tools and apparatus. It is also necessary to devise a method to avoid a tool, if possible, or to use a substitute of phthalate free. If the use of any plastic tool to cause contamination is inevitable, it should be properly corrected with a blank level, as is equally treated as the sample. The clean-up process demonstrated in this study can give us a significant benefit in terms of the quantity and quality of a target compound by GC/MS analysis.

Analysis of performance test results of CA-certified air cleaners from 2003 to 2015 (2003년부터 2015년까지 CA 인증 공기청정기의 성능 시험 결과 분석)

  • Kim, Hak-Joon;Hong, Kee-Jung;Woo, Chang Gyu;Han, Bangwoo;Kim, Yong-Jin
    • Particle and aerosol research
    • /
    • v.13 no.1
    • /
    • pp.17-23
    • /
    • 2017
  • In this study, the test results obtained from the performance tests for CA (Korea Association of Cleaning Air) certificated air cleaners which had been commercially available in Korea from 2003 to 2015 were analyzed. Among the test parameters such as flow rate, particle collection efficiency, clean air delivery rate (CADR), ozone emission, odor removal efficiency and noise level, noise level and CADR were correlated with flow rates. Collection and odor removal efficiencies were 20% higher than the limit of the CA certification. The ozone emissions from the air cleaners were negligible because all the air cleaners were equipped with only HEPA filters, not electrostatic precipitation method which produces ozone.