• Title/Summary/Keyword: Class V

Search Result 1,016, Processing Time 0.029 seconds

A Prospect of the Future Power System Configuration with 22kV Class Superconducting Cable (22kV급 초전도 케이블을 이용한 미래 전력계통 구성 방안 고찰)

  • Kim, Jong-Yul;Yoon, Jae-Young;Choi, Heung-Kwan
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.406-408
    • /
    • 2003
  • As power demand increases gradually, the call for underground transmission system increases. But it is very difficult and high in cost to construct new ducts and/or tunnels for power cables in metropolitan areas. HTS (High Temperature Superconducting) cable has the several useful characteristics such as increased power density. Therefore HTS cable can allow more power to be moved in existing ducts, which means very large economical and environmental benefits. In this paper, we investigate the status of korean power system and underground transmission system. Based on this, the feasibility study on applying 22kV class HTS cable to korean power system is carried out and then we propose the new power system configuration of metropolitan area with 22kV class HTS cable.

  • PDF

Surface roughness and microleakage of class V composite restorations : Effect of surface sealing

  • Kim, Min-Jeong;Yu, Mi-Kyung;Lee, Kwang-Won
    • Proceedings of the KACD Conference
    • /
    • 2003.11a
    • /
    • pp.572-572
    • /
    • 2003
  • There were attempts to reduce the micro leakage and surface roughness of resin composite. One of them is surface sealing. The purpose of this study was to compare the effect of materials, specifically developed for surface sealing, on microleakage and surface roughness in Class V composite restorations. Twenty five standardized Class V cavity preparations were made on the facial surface of extracted human premolars and were randomly assigned to 5 groups. The teeth were restored with Z-250 resin composite after applying Single Bond adhesive system.(중략)

  • PDF

Insulation Design for a 154 kV Class HTS Power Cable (154kV급 고온초전도 전력케이블의 전기절연 설계)

  • Kwag, Dong-Soon;Cheon, Hyeon-Gweon;Choi, Jae-Hyeong;Kim, Hae-Jong;Cho, Jeon-Wook;Yun, Mun-Soo;Kim, Sang-Hyun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.8 no.1
    • /
    • pp.29-33
    • /
    • 2006
  • A 154 kV class high temperature superconducting (HTS) power cable system is developing in Korea. For insulation design or this cable, the grading method of insulating paper is proposed. The use of graded insulation gives improved bending properties of the cable. Therefore, we discussed the electrical stress distribution and calculation for grading insulation design of a HTS cable. Also. the basic insulation design of 154 kV class HTS power cable was done.

Study on the Variations of Inter-annual Tracheid Length for Korean Red Pine from Sokwang-ri in Uljin (경상북도 울진군 소광리 소나무의 가도관 길이 변이 분석)

  • Seo, Jeong-Wook;Eom, Chang-Deuk;Park, So-Yeon
    • Journal of the Korean Wood Science and Technology
    • /
    • v.42 no.6
    • /
    • pp.646-652
    • /
    • 2014
  • This study was carried out to test the possibility that tracheid length of red pine growing in Sokwang-ri in Uljin could be used as one of variables to estimate its wood properties. For the study, forest stands of V (500 m a.s.l.) and VIIII (900 m a.s.l.) age class plots were selected in the region, and three trees in each plot were investigated. The tracheid length was separately measured for early- and latewood. It took approximately 25 and 40 years for V and VIIII age class stands, respectively, until the length was stabilized. The lengths in latewood were 3.14 (V age class) and 3.30 (VIIII age class) mm, and in earlywood 2.98 (V age class) and 3.15 (VIIII age class) mm. The lengths in latewood therefore were longer than in earlywood and the lengths for VIIII age class were longer than for V age class. However, the ratio between their lengths in early- and latewood was the same as 0.96 in all age classes. It might be verified whether this ratio can be used as a variable to test the wood property according to provinces by comparing it with others.

POSITIVE RADIAL SOLUTIONS FOR A CLASS OF ELLIPTIC SYSTEMS CONCENTRATING ON SPHERES WITH POTENTIAL DECAY

  • Carriao, Paulo Cesar;Lisboa, Narciso Horta;Miyagaki, Olimpio Hiroshi
    • Bulletin of the Korean Mathematical Society
    • /
    • v.50 no.3
    • /
    • pp.839-865
    • /
    • 2013
  • We deal with the existence of positive radial solutions concentrating on spheres for the following class of elliptic system $$\large(S) \hfill{400} \{\array{-{\varepsilon}^2{\Delta}u+V_1(x)u=K(x)Q_u(u,v)\;in\;\mathbb{R}^N,\\-{\varepsilon}^2{\Delta}v+V_2(x)v=K(x)Q_v(u,v)\;in\;\mathbb{R}^N,\\u,v{\in}W^{1,2}(\mathbb{R}^N),\;u,v&gt;0\;in\;\mathbb{R}^N,}$$ where ${\varepsilon}$ is a small positive parameter; $V_1$, $V_2{\in}C^0(\mathbb{R}^N,[0,{\infty}))$ and $K{\in}C^0(\mathbb{R}^N,[0,{\infty}))$ are radially symmetric potentials; Q is a $(p+1)$-homogeneous function and p is subcritical, that is, 1 < $p$ < $2^*-1$, where $2^*=2N/(N-2)$ is the critical Sobolev exponent for $N{\geq}3$.

EXISTENCE OF POSITIVE SOLUTIONS FOR A CLASS OF QUASILINEAR ELLIPTIC SYSTEM WITH CONCAVE-CONVEX NONLINEARITIES

  • Yin, Honghui;Yang, Zuodong
    • Journal of applied mathematics & informatics
    • /
    • v.29 no.3_4
    • /
    • pp.921-936
    • /
    • 2011
  • In this paper, our main purpose is to establish the existence of weak solutions of a weak solutions of a class of p-q-Laplacian system involving concave-convex nonlinearities: $$\{\array{-{\Delta}_pu-{\Delta}_qu={\lambda}V(x)|u|^{r-2}u+\frac{2{\alpha}}{\alpha+\beta}|u|^{\alpha-2}u|v|^{\beta},\;x{\in}{\Omega}\\-{\Delta}p^v-{\Delta}q^v={\theta}V(x)|v|^{r-2}v+\frac{2\beta}{\alpha+\beta}|u|^{\alpha}|v|^{\beta-2}v,\;x{\in}{\Omega}\\u=v=0,\;x{\in}{\partial}{\Omega}}$$ where ${\Omega}$ is a bounded domain in $R^N$, ${\lambda}$, ${\theta}$ > 0, and 1 < ${\alpha}$, ${\beta}$, ${\alpha}+{\beta}=p^*=\frac{N_p}{N_{-p}}$ is the critical Sobolev exponent, ${\Delta}_su=div(|{\nabla}u|^{s-2}{\nabla}u)$ is the s-Laplacian of u. when 1 < r < q < p < N, we prove that there exist infinitely many weak solutions. We also obtain some results for the case 1 < q < p < r < $p^*$. The existence results of solutions are obtained by variational methods.

An Experimental Comparison of the Fluidity of G-class cement with Portland cement (지열발전을 위한 지열정 시멘트용 G-class시멘트와 일반 포틀랜드시멘트와의 유동성 비교실험)

  • Jeon, Jong-Ug;Won, Jong-Muk;Choi, Hang-Seok
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.8 no.2
    • /
    • pp.1-8
    • /
    • 2012
  • The G-class cement is usually used for geothermal well grouting to protect a steel casing which is equipped in a geothermal well to transfer geothermal water from deep subsurface to ground surface. In geothermal grouting process, obtaining appropriate fluidity is extremely important in order to fill cement grout flawlessly. In this paper, a series of the V-funnel and Slump Flow test was performed on both of the Portland cement and the G-class cement in order to compare fluidity and filling ability of those kind of cements. In the result of V-funnel test, the fluidity of G-class cement was evaluated much better than the Portland cement at the water/cement ratio of 0.8. In the case of Slump Flow test, the fluidity of G- class cement was estimated slightly better than the Portland cement at both the water/cement ratio of 0.55 and 0.8. Even though the initial fluidity and filling ability of G-class cement were relatively higher than the Portland cement, the results could be considerably changed with time. The results show that the fluidity and filling ability for geothermal well cementation can be properly controlled with water content and additives for adverse geothermal well environment.

Correlation between Insulation Diagnostic Test and AC Breakdown Test for 3.3 kV Class Induction Motor

  • Byun, Doo-Gyoon;Hong, Jin-Woong
    • Transactions on Electrical and Electronic Materials
    • /
    • v.7 no.5
    • /
    • pp.262-266
    • /
    • 2006
  • The insulation diagnostic test and the AC breakdown test were performed under off-line using the 3.3 kV class induction motor which have been served for 10 years. These tests were conducted in means of nondestructive and destructive test. In this paper, we compared the correlation between the nondestructive and destructive test. Furthermore we setup an experimental condition with moisture and compared the insulation characteristics between moist and dry sample. From the results of the nondestructive and destructive test, it was found that the second AC current, which is the previous step of insulation breakdown, suddenly increased at a point of around 8.5 kV. The insulation breakdown of moist sample occurred at 12-14 kV, which is 4-5 kV lower than dry sample.

PERFECT IDEALS OF GRADE THREE DEFINED BY SKEW-SYMMETRIZABLE MATRICES

  • Cho, Yong-Sung;Kang, Oh-Jin;Ko, Hyoung-June
    • Bulletin of the Korean Mathematical Society
    • /
    • v.49 no.4
    • /
    • pp.715-736
    • /
    • 2012
  • Brown provided a structure theorem for a class of perfect ideals of grade 3 with type ${\lambda}$ > 0. We introduced a skew-symmetrizable matrix to describe a structure theorem for complete intersections of grade 4 in a Noetherian local ring. We construct a class of perfect ideals I of grade 3 with type 2 defined by a certain skew-symmetrizable matrix. We present the Hilbert function of the standard $k$-algebras R/I, where R is the polynomial ring $R=k[v_0,v_1,{\ldots},v_m]$ over a field $k$ with indeterminates $v_i$ and deg $v_i=1$.