• 제목/요약/키워드: Chopper Amplifier

검색결과 23건 처리시간 0.021초

매연입자의 LII 신호를 이용한 충류확산화염 유동속도 측정 (Flow Velocity Measurement for Laminar Diffusion Flames Utilizing LII Signal from Soot Particles)

  • 이정수;남연우;이원남
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2006년도 제32회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.157-163
    • /
    • 2006
  • A new technique utilizing LII signal for the measurement of flow velocities of laminar diffusion flames has been investigated. Soot particles in ethylene diffusion flames are heated by a modulated Ar-ion laser beam. LII signals and their phase angles are measured using a lock-in amplifier at the different flame heights and the axial flow velocity are obtained from the measured phase angle delay. The measured velocities are similar to those from LDV measurements under the same operating conditions. The effects of laser power, LII signal wavelength, and modulation frequency are not sensitive to the velocity measurement. However, the choice of an optical chopper blade type could affect the measurement result. The use of a 6/5 chopper blade showed the better result that is possibly due to the square shape of modulated laser beam. This study successfully demonstrated that axial flow velocities of laminar diffusion flames can be measured by a new technique utilizing LII signal, which does not need particle seeding unlikely to LDV or PIV techniques.

  • PDF

공통-모드 간섭 (CMI)에 강인한 2-전극 기반 심전도 계측 회로 (CMI Tolerant Readout IC for Two-Electrode ECG Recording)

  • 강상균;남경식;고형호
    • 센서학회지
    • /
    • 제32권6호
    • /
    • pp.432-440
    • /
    • 2023
  • This study introduces an efficient readout circuit designed for two-electrode electrocardiogram (ECG) recording, characterized by its low-noise and low-power consumption attributes. Unlike its three-electrode counterpart, the two-electrode ECG is susceptible to common-mode interference (CMI), causing signal distortion. To counter this, the proposed circuit integrates a common-mode charge pump (CMCP) with a window comparator, allowing for a CMI tolerance of up to 20 VPP. The CMCP design prevents the activation of electrostatic discharge (ESD) diodes and becomes operational only when CMI surpasses the predetermined range set by the window comparator. This ensures power efficiency and minimizes intermodulation distortion (IMD) arising from switching noise. To maintain ECG signal accuracy, the circuit employs a chopper-stabilized instrumentation amplifier (IA) for low-noise attributes, and to achieve high input impedance, it incorporates a floating high-pass filter (HPF) and a current-feedback instrumentation amplifier (CFIA). This comprehensive design integrates various components, including a QRS peak detector and serial peripheral interface (SPI), into a single 0.18-㎛ CMOS chip occupying 0.54 mm2. Experimental evaluations showed a 0.59 µVRMS noise level within a 1-100 Hz bandwidth and a power draw of 23.83 µW at 1.8 V.

층류화염 유동속도 측정을 위한 modulated LII 기법 (Modulated LII technique for the Measurement of Flow Velocity in Laminar Flames)

  • 이원남;이정수;남연우
    • 한국연소학회지
    • /
    • 제11권3호
    • /
    • pp.36-43
    • /
    • 2006
  • The modulated LII technique has been suggested for the measurement of axial velocity profiles of laminar diffusion flames. The theoretical background is explained based on the blackbody radiation and LII signal. Experimentally, soot particles in ethylene diffusion flames are heated by a modulated Ar-ion laser beam. LII signals and their phase angles are measured using a lock-in amplifier at the different flame heights and the axial flow velocities are obtained from the measured phase angle delay informations. The measured velocities are similar to those from LDV measurements under the same operating conditions. The effects of laser power, LII signal wavelength, and modulation frequencies are not sensitive to the velocity measurement. However, the choice of an optical chopper blade type could affect the measurement result. The use of a 6/5 chopper blade showed the better result that is. possibly due to the square shape of modulated laser beam. This study successfully demonstrated that axial flow velocities of laminar diffusion flames can be measured by a new technique utilizing LII signal, which does not need particle seeding unlikely to LDV or PIV techniques.

  • PDF

선형 계수율계에 관한 연구 (A Study on the Linear Counting Ratemeter)

  • 이병선
    • 대한전자공학회논문지
    • /
    • 제8권6호
    • /
    • pp.8-16
    • /
    • 1971
  • 본 논문은 원자로 또는 방사성 동위요소등에서 방사되는 방사선의 계수률을 선형적으로 미터로 지시할 수 있는 동시에 기록계로도 기록할 수 있는 완전 트랜지스터화된 선형 계수률계의 개발에 관한 연구이다. 이 계수률계는 양호한 안정을 위하여 트랜지스터 Chopper를 사용하였다. 교류증폭기의 입력단에는 높은 입력저항을 주기 위하여 composite emitter follower buffer stage를 사용하였으며 hybrid parameter 등가회로를 구성하여 해석하였다. 계수률은 수 CPS로 부터 100KCPS까지 4개 영역으로 나누어서 선형적으로 계수할 수 있으며 분해능은 0.5μsec 미만이고 상온에서의 출력 drift는 7시간 계속동작시켰을시에 ±0.5μA 정도이다.

  • PDF

A Hybrid Audio ${\Delta}{\Sigma}$ Modulator with dB-Linear Gain Control Function

  • Kim, Yi-Gyeong;Cho, Min-Hyung;Kim, Bong-Chan;Kwon, Jong-Kee
    • ETRI Journal
    • /
    • 제33권6호
    • /
    • pp.897-903
    • /
    • 2011
  • A hybrid ${\Delta}{\Sigma}$ modulator for audio applications is presented in this paper. The pulse generator for digital-to-analog converter alleviates the requirement of the external clock jitter and calibrates the coefficient variation due to a process shift and temperature changes. The input resistor network in the first integrator offers a gain control function in a dB-linear fashion. Also, careful chopper stabilization implementation using return-to-zero scheme in the first continuous-time integrator minimizes both the influence of flicker noise and inflow noise due to chopping. The chip is implemented in a 0.13 ${\mu}m$ CMOS technology (I/O devices) and occupies an active area of 0.37 $mm^2$. The ${\Delta}{\Sigma}$ modulator achieves a dynamic range (A-weighted) of 97.8 dB and a peak signal-to-noise-plus-distortion ratio of 90.0 dB over an audio bandwidth of 20 kHz with a 4.4 mW power consumption from 3.3 V. Also, the gain of the modulator is controlled from -9.5 dB to 8.5 dB, and the performance of the modulator is maintained up to 5 nsRMS external clock jitter.

전기차량에 적용한 Bang-Bang 제어기 연구 (A Study on The Bang-Bang Controller Applied to Electrical Vehicle)

  • 배종일
    • 전기학회논문지
    • /
    • 제65권6호
    • /
    • pp.1089-1094
    • /
    • 2016
  • In order to establish the robust controller design technique of series wound motor driver system. This paper proposes a method of Bang-Bang controller using a series wound motor driver system under improperly variable load. A Bang-Bang controller structure is simpler than the structure of PID plus Bang-Bang controller. This paper shows that a general 8 bits microprocessor is used efficiently implementing such an algorithm. The calculation time of software is extremely small when compared with conventional PID plus Bang-Bang controller. Both nonlinear operating characteristics of digital switching elements and describing function methods are used for the analysis and synthesis. Real time implementation of Bang-Bang controller is achieved. Concept design strategy of the control and PWM waveform generation algorithms are presented in the paper.

비접촉 방법에 의한 표면탄성파의 검출 (A Study on the Detection of Surface Acoustic Waves by Noncontact Method)

  • 유일현;윤정심;김동일
    • 비파괴검사학회지
    • /
    • 제10권2호
    • /
    • pp.56-62
    • /
    • 1990
  • Surface Acoustic Waves(SAW) are generated on silicon wafer and $YZ-LiTaO_3$ substrate and are detected by noncontact method. As wave sources two kinds of transducers are used : the wedge-type of 20.0 MHz and fabricated Interdigital Transducer(IDT) of 20.8 MHz. SAW are modulated by the optical chopper frequency and are syncronized with a laser beam. In signal processing, intensity variations of light due to the intensity of SAW are analyzed using lock- in amplifier. From the results, corresponding to the applied input power, the intensity variations of a deflected light by corrugations on the substrates are increased and saturation phenomenon is observed.

  • PDF

고감도 삼상력률계전기에 관한 연구 (Study on the High Sensitive Three Phase Power Factor Meter and Relay)

  • 박정후
    • 수산해양기술연구
    • /
    • 제16권1호
    • /
    • pp.43-47
    • /
    • 1980
  • The author designed and tested the high sensitive three-phase power factor meter and relay circuit, and dealt with the circuit to detect the phase of the current and the voltage. An operational amplifier comparator circuit and two single-phase transformers are used to control and detect the phase angle between the current and the voltage. The results obtained are as follows: 1. Converting the sine wave input current into the constant amplitude rectangular wave form by using a transistor chopper circuit, the power factor can be measured precisely over the load current of 0.08 A. 2. Using the moving coil type current meter, the power factor meter can be read in uniform . scale all over the range. 3. Using the three-phase power factor meter, the power factor relay which works at any power factor can be made.

  • PDF

광학적 측정방법에 의한 표면 탄성파의 감쇠에 관한 연구 (A Study on the Attenuation of Surface Acoustic Waves by Optical Measurement Method)

  • 유일현;김동일
    • 비파괴검사학회지
    • /
    • 제14권4호
    • /
    • pp.237-243
    • /
    • 1995
  • 고체 시료를 대상으로 하여 silicon wafer에는 $90^{\circ}$ wedge형 진동자를 사용하고 압전재료인 $LiTaO_3$에는 interdigital transducer(IDT)를 사용하였으며, knife edge를 이용한 광학적 검지(optical probing)법을 써서 표면탄성파의 발생 및 측정하는 기법으로써 재료에서의 표면탄성파의 감쇠를 검출하는 방법을 연구하였다. IDT1 및 IDT2로는 20.8 MHz와 14.5 MHz를, $90^{\circ}$ wedge형 진동자로부터는 20.0 MHz의 표면탄성파를 발생시켰으며 표면탄성파로 생기는 표면의 굴곡을 검출하는데 He-Ne laser beam을 이용하였다. Optical chopper로 변조시킨 laser beam을 같은 주파수로 변조시킨 표면탄성파에 입사시켜 산란되는 광을 같은 주파수로 동조된 lock-in amplifier로 검출하였다. 이와 같이 함으로써 검출할 표면탄성파와 검출에 사용된 laser beam 및 측정기기인 위상감지기(Phase Sensitive Detector : PSD)를 같은 주파수로 변조하여 동기시킬 수 있었으며 측정계를 단순화하였다. IDT1, IDT2에서 발생된 표면탄성과의 감쇠계수는 각각 $0.62{\sim}0.75dB/mm,\;0.60{\sim}0.72dB/mm$였으며 wedge형 진동자에서는 $0.83{\sim}1.28dB/mm$인 값을 얻었다.

  • PDF

임피던스 변환 회로를 이용한 건식능동뇌파전극 개발 (Development of an Active Dry EEG Electrode Using an Impedance-Converting Circuit)

  • 고덕원;이관택;김성민;이찬희;정영진;임창환;정기영
    • Annals of Clinical Neurophysiology
    • /
    • 제13권2호
    • /
    • pp.80-86
    • /
    • 2011
  • Background: A dry-type electrode is an alternative to the conventional wet-type electrode, because it can be applied without any skin preparation, such as a conductive electrolyte. However, because a dry-type electrode without electrolyte has high electrode-to-skin impedance, an impedance-converting amplifier is typically used to minimize the distortion of the bioelectric signal. In this study, we developed an active dry electroencephalography (EEG) electrode using an impedance converter, and compared its performance with a conventional Ag/AgCl EEG electrode. Methods: We developed an active dry electrode with an impedance converter using a chopper-stabilized operational amplifier. Two electrodes, a conventional Ag/AgCl electrode and our active electrode, were used to acquire EEG signals simultaneously, and the performance was tested in terms of (1) the electrode impedance, (2) raw data quality, and (3) the robustness of any artifacts. Results: The contact impedance of the developed electrode was lower than that of the Ag/AgCl electrode ($0.3{\pm}0.1$ vs. $2.7{\pm}0.7\;k{\Omega}$, respectively). The EEG signal and power spectrum were similar for both electrodes. Additionally, our electrode had a lower 60-Hz component than the Ag/AgCl electrode (16.64 vs. 24.33 dB, respectively). The change in potential of the developed electrode with a physical stimulus was lower than for the Ag/AgCl electrode ($58.7{\pm}30.6$ vs. $81.0{\pm}19.1\;{\mu}V$, respectively), and the difference was close to statistical significance (P=0.07). Conclusions: Our electrode can be used to replace Ag/AgCl electrodes, when EEG recording is emergently required, such as in emergency rooms or in intensive care units.