• Title/Summary/Keyword: Chip on glass

Search Result 176, Processing Time 0.03 seconds

Low Temperature Co-firing of Camber-free Ceramic-metal Based LED Array Package (세라믹-금속 기반 LED 어레이 패키지의 저온동시소성시 휨발생 억제 연구)

  • Heo, Yu Jin;Kim, Hyo Tae
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.23 no.4
    • /
    • pp.35-41
    • /
    • 2016
  • Ceramic-metal based high power LED array package was developed via thick film LTCC technology using a glass-ceramic insulation layer and a silver conductor patterns directly printed on the aluminum heat sink substrate. The thermal resistance measurement using thermal transient tester revealed that ceramic-metal base LED package exhibited a superior heat dissipation property to compare with the previously known packaging method such as FR-4 based MCPCB. A prototype LED package sub-module with 50 watts power rating was fabricated using a ceramic-metal base chip-on-a board technology with minimized camber deformation during heat treatment by using partially covered glass-ceramic insulation layer design onto the aluminum heat spread substrate. This modified circuit design resulted in a camber-free packaging substrate and an enhanced heat transfer property compared with conventional MCPCB package. In addition, the partially covered design provided a material cost reduction compared with the fully covered one.

A Method for Evaluation of the Quality of DNA Microarray Spots

  • Zhang, Bao;Ma, Wen-Li;Hu, Zi-You;Shi, Rong;Song, Yan-Bin;Zheng, Wen-Ling
    • BMB Reports
    • /
    • v.35 no.5
    • /
    • pp.532-535
    • /
    • 2002
  • To establish a method to evaluate the quality of the printed microarray and DNA fragments' immobilization. The target gene fragments that were made with the restriction display PCR (RD-PCR) technique were printed on a superamine modified glass slide, then immobilized with UV cross-linking and heat. This chip was hybridized with universal primers that were labeled with cy3-dUTP, as well as cDNA that was labeled with cy3-dCTP, as the conventional protocol. Most of the target gene fragments on the chip showed positive signals, but the negative control showed no signal, and vice versa. We established a method that enables an effective evaluation of the quality of the microarrays.

Microfabrication of Microwave Transceivers for On-Chip Near-Field Electromagnetic Shielding Characterization of Electroplated Copper Layers (극소형 전자기파 송수신기의 제작 및 전기도금된 구리박막의 칩단위 근접 전자기장 차폐효과 분석)

  • Gang, Tae-Gu;Jo, Yeong-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.6
    • /
    • pp.959-964
    • /
    • 2001
  • An experimental investigation on the near-field electromagnetic loss of thin copper layers has been presented using microfabricated microwave transceivers for applications to multi-chip microsystems. Copper layers in the thickness range of 0.2$\mu$m∼200$\mu$m have been electroplated on the Pyrex glass substrates. Microwave transceivers have been fabricated using the 3.5mm$\times$3.5mm nickel microloop antennas, electroformed on the silicon substrates. Electromagnetic radiation loss of the copper layers placed between the microloop transceivers has been measured as 10dB∼40dB for the wave frequency range of 100MHz∼1GHz. The 0.2$\mu$m-thick copper layer provides a shield loss of 20dB at the frequencies higher than 300MHz, whereas showing a predominant decreases of shield loss to 10dB at lower frequencies. No substantial increase of the shield effectiveness has been found for the copper shield layers thicker that 2 $\mu$m.

Flexible Display i Low Temperature Processes for Plastic LCDs

  • Han, Jeong-In
    • Transactions on Electrical and Electronic Materials
    • /
    • v.4 no.2
    • /
    • pp.10-14
    • /
    • 2003
  • Flexible displays such as plastic-based liquid crystal displays (LCDs) and organic light-emitting diode displays (OLEDDs) have been researched and developed at KETI since 1997. The plastic film substrate is very weak to heat and pressure compared to glass substrate, that its fabrication process is limited to 110$^{\circ}C$ and low pressure. The ITO films were deposited on the bare plastic film substrate by rf-magnetron sputtering. Moreover, in order to maintain uniform cell gap and pressure on the plastic film substrate, we utilized newly-invented jig and fabrication process. Electro-optical characteristics were better than or equivalent to those of typical glass LCDs though it is thinner, lighter-weight, and more robust than glass LCDs.

Preparation of Porous PLGA Microfibers Using Gelatin Porogen Based on a Glass Capillary Device (젤라틴 기공유도물질과 유리모세관 장치를 이용한 다공성 PLGA 미세섬유의 제조)

  • Kim, Chul Min;Kim, Gyu Man
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.1
    • /
    • pp.63-67
    • /
    • 2016
  • We present a method of fabricating poly (lactic-co-glycolic acid) (PLGA) porous microfibers using a pore template. PLGA microfibers were synthesized using a glass capillary tube in a poly-(dimethylsiloxane) (PDMS) microfluidic chip. Gelatin solution was used as a porous template to prepare pores in microfibers. Two phases of PLGA solutions in different solvents-DMSO (dimethyl sulfoxide) and DCM (dichloromethane)-were used to control the porosity and strength of the porous microfibers. The porosity of the PLGA microfibers differed depending on the ratio of flow rates in the two phases. The porous structure was formed in a spiral shape on the microfiber. The porous structure of the microfiber is expected to improve transfer of oxygen and nutrients, which is important for cell viability in tissue engineering.

One-Touch Type Immunosenging Lab-on-a-chip for Portable Point-of-care System (휴대용 POC 시스템을 위한 원터치형 면역 센싱 랩온어칩)

  • Park, Sin-Wook;Kang, Tae-Ho;Lee, Jun-Hwang;Yoon, Hyun-C.;Yang, Sang-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.8
    • /
    • pp.1424-1429
    • /
    • 2007
  • This paper presents a simple and reliable one-touch type multi-immunosensing lab-on-a-chip (LOC) detecting antibodies as multi-disease markers using electrochemical method suitable for a portable point-of-care system (POCS). The multi-stacked LOC consists of a PDMS space layer for liquids loading, a PDMS valve layer with 50 im in height for the membrane, a PDMS channel layer for the fluid paths, and a glass layer for multi electrodes. For the disposable immunoassay which needs sequential flow control of sample and buffer liquids according to the designed strategies, reliable and easy-controlled on-chip operation mechanisms without any electric power are necessary. The driving forces of sequential liquids transfer are the capillary attraction force and the pneumatic pressure generated by air bladder push. These passive fluid transport mechanisms are suitable for single-use LOC module. Prior to the application of detection of the antibody as a disease marker, the model experiments were performed with anti-DNP antibody and anti-biotin antibody as target analytes. The flow test results demonstrate that we can control the fluid flow easily by using the capillary stop valve and the PDMS check valves. By the model tests, we confirmed that the proposed LOC is easily applicable to the bioanalytic immunosensors using bioelectrocatalysis.

Protein Adsorption on the Nickel-coated Glass Slide for Protein Chips

  • Hyun, June-Won;Kim, Shi-Yong;Lee, Sang-Hee;Park, Heon-Yong;Pyee, Jae-Ho;Kim, Sung-Hoon
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.12
    • /
    • pp.1724-1728
    • /
    • 2002
  • The adsorption of proteins on the surface of glass slides is essential for the construction of protein chips. Here, we report that a Histidine (His)-tagged protein protein has been efficiently adsorbed on glass coated with nickel. A variety of nickel chloride-coated plates were prepared by the spin-coating method and adsorbed to the His-tagged protein. When the protein was adsorbed onto the surface of a variety of nickel chloride-coated glass slides, the efficiency of protein adsorption was dependent upon the coating conditions such as nickel chloride concentration, the spin speed and the drying temperature. The slides appropriate for protein adsorption were obtained when the slides were coated with 11%(w/w) of $NiCl_2$ at the spin speed of 4000 rpm for 20 sec and then dried at higher than 40°C. The physical properties of their nickel chloride thin layer were characterized by scanning electron microscopy. x-ray diffraction and atomic force microscopy, finding that the nickel chloride particles were around 10 nm in diameter and uniformly crystallized at 101 faces. These results show that nickel chloride-coated slides prepared by the spin-coating method are utilizable for the construction of Histagged protein chips.