• Title/Summary/Keyword: Chip Flow

Search Result 315, Processing Time 0.024 seconds

A study on the development of CW(Continuous-Wave) Doppler System using FFT (FFT를 이용한 연속초음파 도플러 장치에 관한 연구)

  • Lee, Dae-Hyung;Kang, Chung-Shin;Park, Sei-Hyun;Kim, Young-Kil
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.709-712
    • /
    • 1988
  • Ultrasonic Doppler Diagnostic System utilizes the Doppler effect for measurement of blood velocity. The sign of the Doppler frequency shift represents blood flow direction. CW(Continuous-Wave) Doppler System uses quadrature detection and phase rotation method to produce simultaneous independent audio and velocity signals for forward and reverse blood flow direction in the time-domain, had been fabricated. But time-domain analyzing such as audio evaluation and zero- crossing detection for instantaneous and mean frequnecy measurement do not provide both an accurate and quantitative result. Therefore, it is necessary to adopt frequency-domain technique to improve system performance. In this paper, we describe a unit which is composed of CW Doppler System and real-time spectrum analyzer (installed TMS 32010 DSP Chip). This unit shows time-dependent spectrum variation and mean velocity of Blood signal.

  • PDF

Development of Exhaust Flow Controller for P/R Coater Process (P/R Coater공정용 Exhaust Flow Controller의 개발)

  • Park, Chan-Won;Kim, Hyun-Sik;Joo, Yong-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 2002.07d
    • /
    • pp.2185-2187
    • /
    • 2002
  • 본 연구에서는 반도체 제조공정에서 photo resister를 도포하고 제거하는 coater와 developer 장치에서 도포막의 균일화를 위한 배기장치의 정밀한 유량제어기술을 소개 하고자 한다. 개발된 배기 제어장치는 차압식 유량계로서 차동 압력센싱 방식을 이용하고 One chip microprocessor로 A/D변환과 피드백 서보제어로 장치를 구현하였으며 제어 유량은 최대 2000${\ell}$/min로서 개발 후 성능과 안정성 평가가 우수하여 실제장비에의 장착이 가능하였다.

  • PDF

Voltammetric Analysis on a Disposable Microfluidic Electrochemical Cell

  • Chand, Rohit;Han, Dawoon;Kim, Yong-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.4
    • /
    • pp.1175-1180
    • /
    • 2013
  • A microfabricated electrochemical cell comprising PDMS-based microchannel and in-channel gold microelectrodes was fabricated as a sensitive and a miniature alternative to the conventional electroanalytical systems. A reproducible fabrication procedure enabled patterning of multiple microelectrodes integrated within a PDMS-based fluidic network. The active area of each electrode was $200{\mu}m{\times}200{\mu}m$ with a gap of $200{\mu}m$ between the electrodes which resulted in a higher signal to noise ratio. Also, the PDMS layer served the purpose of shielding the electrical interferences to the measurements. Analytes such as potassium ferrocyanide; amino acid: cysteine and nucleoside: guanosine were characterized using the fabricated cell. The microchip was comparable to bulk electrochemical systems and its applicability was also demonstrated with flow injection based rapid amperometric detection of DNA samples. The device so developed shall find use as a disposable electrochemical cell for rapid and sensitive analysis of electroactive species in various industrial and research applications.

Miniaturization of Polymerase Chain Reaction

  • Lee, Ji-Youn;Kim, Jae-Jeong;Park, Tai-Hyun
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.8 no.4
    • /
    • pp.213-220
    • /
    • 2003
  • Polymerase chain reaction (PCR) is one of the most widely used analytical tool and is an important module that would benefit from being miniaturized and integrated onto diagnostic or analytical chips. There are potentially two different approaches for the miniaturization of the PCR module: chamber-type and flow-type micro-PCR. These miniaturized PCRs have distinct characteristics and advantages. In this article, we review the necessity of micro-PCR, the materials for the chip fabrication, the surface modification, and characteristics of the two types of micro-PCR. The motivation underlying the development of micro-PCR, the advantages and disadvantages of the various materials used in fabrication and the surface modification methods will be discussed. And finally, the precise features of the two different types of micro-PCR will be compared.

Electro-migration Phenomenon in Flip-chip Packages (플립칩 패키지에서의 일렉트로마이그레이션 현상)

  • Lee, Ki-Ju;Kim, Keun-Soo;Suganuma, Katsuaki
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.17 no.4
    • /
    • pp.11-17
    • /
    • 2010
  • The electromigration phenomenon in lead-free flip-chip solder joint has been one of the serious problems. To understand the mechanism of this phenomenon, the crystallographic orientation of Sn grain in the Sn-Ag-Cu solder bump has been analyzed. Different time to failure and different microstructural changes were observed in the all test vehicle and bumps, respectively. Fast failure and serious dissolution of Cu electrode was observed when the c-axis of Sn grain parallel to electron flow. On the contrary of this, slight microstructural changes were observed when the c-axis of Sn perpendicular to electron flow. In addition, underfill could enhance the electromigration reliability to prevent the deformation of solder bump during EM test.

Thermal Characteristics of Designed Heat Sink for 13.5W COB LED Down Light (주거용 13.5W COB LED 다운라이트 방열판 형상 설계에 따른 열 특성 분석)

  • Kwon, Jae-Hyun;Kim, Hyo-Jun;Park, Keon-Jun;Kim, Yong-Kab;Hoang, Geun-Chang
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.5
    • /
    • pp.561-566
    • /
    • 2014
  • The high power COB(Chip on Board) LED, densely arranged chips on a board, are increasing to resolve heat problems in LED that has luminous semiconductor chips as main materials. In case of high-power COB LED, protection against heat is necessary due to the power consumption is high. Also if the temperature of device increases, the optical emission becomes less efficient and the life rapidly reduces due to thermal stress. This study packaged 13.5W COB LED and heat sink with difference form and produced 13.5W COB LED down-light heat sink by analyzing the thermal modes with Solidworks Flow Simulation. And finally it analyzed and evaluated the thermal modes using contacting and non-contacting thermometers.

Thermal Characteristics of the Optimal Design on 15W COB LED Down Light Heat Sink (주거용 15W COB LED 다운라이트 방열판 최적설계에 따른 열적 특성 분석 및 평가)

  • Kwon, Jae-Hyun;Park, Keon-Jun;Kim, Tae-Hyung;Kim, Yong-Kab
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.2
    • /
    • pp.401-407
    • /
    • 2014
  • There are increasing interests in COB (Chip On Board) that densely arranged many LED chips on one board in order to solve the heat issue. There are many problems being on the rise: the lifespan decreases as the temperature of LED devices increases; Red Shift phenomenon, in which wave length of spectral line moves from original wave length to long wave length, occurs; and optical power decreases as $T_j$ increases. In order to resolve such problems, this study selected the optimum thickness and length of Fin, planned the second Heat sink that is optimum for COB LED with 15W, and analyzed thermal mode by Solid Works Flow Simulation through 15W COB packaging with the planned Heat sink. 15W COB down-light Heat sink that is produced based on this analysis was utilized to analyze thermal mode through contact thermometer and electrical properties through Kelthley 2430.

A Realization of CNN-based FPGA Chip for AI (Artificial Intelligence) Applications (합성곱 신경망 기반의 인공지능 FPGA 칩 구현)

  • Young Yun
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2022.11a
    • /
    • pp.388-389
    • /
    • 2022
  • Recently, AI (Artificial Intelligence) has been applied to various technologies such as automatic driving, robot and smart communication. Currently, AI system is developed by software-based method using tensor flow, and GPU (Graphic Processing Unit) is employed for processing unit. However, if software-based method employing GPU is used for AI applications, there is a problem that we can not change the internal circuit of processing unit. In this method, if high-level jobs are required for AI system, we need high-performance GPU, therefore, we have to change GPU or graphic card to perform the jobs. In this work, we developed a CNN-based FPGA (Field Programmable Gate Array) chip to solve this problem.

  • PDF

Permeability of the Lateral Air Flow through Unstructured Pillar-like Nanostructures (비정형 기둥 형상을 가진 나노구조에서의 가스 투과성 실험 연구)

  • Hyewon Kim;Hyewon Lim;Jeong Woo Park;Sangmin Lee;Hyungmo Kim
    • Tribology and Lubricants
    • /
    • v.39 no.5
    • /
    • pp.197-202
    • /
    • 2023
  • Recently, research on experimental and analytical techniques utilizing microfluidic devices has been pursued. For example, lab-on-a-chip devices that integrate micro-devices onto a single chip for processing small sample quantities have gained significant attention. However, during sample preparation, unnecessary gases can be introduced into the internal channels, thus, impeding device flow and compromising specific function efficiency, including that of analysis and separation. Several methods have been proposed to mitigate this issue, however, many involve cumbersome procedures or suffer from complexities owing to intricate structures. Recently, some approaches have been introduced that utilize hydrophobic device structures to remove gases within channels. In such cases, the permeability of gases passing through the structure becomes a crucial performance factor. In this study, a method involving the deposition and sintering of diluted Ag-ink onto a silicon wafer surface is presented. This is followed by unstructured nano-pattern creation using a Metal Assisted Chemical Etching (MACE) process, which yields a nanostructured surface with unstructured pillar shapes. Subsequently, gas permeability in the spaces formed by these surface structures is investigated. This is achieved by experiments conducted to incorporate a pressure chamber and measure gas permeability. Trends are subsequently analyzed by comparing the results with existing theories. Finally, it can be confirmed that the significance of this study primarily lies in its capability to effectively evaluate gas permeability through unstructured pillar-like nanostructures, thus, providing quantitative values for the appropriate driving pressure and expected gas removal time in practical device operation.

Highly Sensitive Detection of Pathogenic Bacteria Using PDMS Micro Chip Containing Glass Bead (유리비드를 포함한 PDMS 마이크로칩을 이용한 고감도 감염성 병원균 측정에 관한 연구)

  • Won, Ji-Yeong;Min, Jun-Hong
    • KSBB Journal
    • /
    • v.24 no.5
    • /
    • pp.432-438
    • /
    • 2009
  • Here, we demonstrated simple nucleic acid, RNA, concentration method using polymer micro chip containing glass bead ($100\;{\mu}m$). Polymer micro chip was fabricated by PDMS ($1.5\;cm\;{\times}\;1.5\;cm$, $100\;{\mu}m$ in the height) including pillar structure ($160\;{\mu}m\;(I)\;{\times}\;80\;{\mu}m\;(w)\;{\times}\;100\;{\mu}m\;(h)$, gap size $50\;{\mu}m$) for blocking micro bead. RNA could be adsorbed on micro glass bead at low pH by hydrogen bonding whereas RNA was released at high pH by electrostatic force between silica surface and RNA. Amount of glass beads and flow rate were optimized in aspects of adsorption and desorption of RNA. Adsorption and desorption rate was measured with real time PCR. This concentrated RNA was applied to amplification micro chip in which NASBA (Nucleic Acid Sequence Based Amplification) was performed. As a result, E.coli O157 : H7 in the concentration of 10 c.f.u./10 mL was successfully detected by these serial processes (concentration and amplification) with polymer micro chips. It implies this simple concentration method using polymer micro chip can be directly applied to ultra sensitive method to measure viable bacteria and virus in clinical samples as well as environmental samples.