• Title/Summary/Keyword: Charge balance condition

Search Result 17, Processing Time 0.034 seconds

Design and Fabrication of Super Junction MOSFET Based on Trench Filling and Bottom Implantation Process

  • Jung, Eun Sik;Kyoung, Sin Su;Kang, Ey Goo
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.3
    • /
    • pp.964-969
    • /
    • 2014
  • In Super Junction MOSFET, Charge Balance is the most important issue of the trench filling Super Junction fabrication process. In order to achieve the best electrical characteristics, the N type and P type drift regions must be fully depleted when the drain bias approaches the breakdown voltage, called Charge Balance Condition. In this paper, two methods from the fabrication process were used at the Charge Balance condition: Trench angle decreasing process and Bottom implantation process. A lower on-resistance could be achieved using a lower trench angle. And a higher breakdown voltage could be achieved using the bottom implantation process. The electrical characteristics of manufactured discrete device chips are compared with those of the devices which are designed of TCAD simulation.

Enhancement of On-Resistance Characteristics Using Charge Balance Analysis Modulation in a Trench Filling Super Junction MOSFET

  • Geum, Jongmin;Jung, Eun Sik;Kim, Yong Tae;Kang, Ey Goo;Sung, Man Young
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.3
    • /
    • pp.843-847
    • /
    • 2014
  • In Super Junction (SJ) MOSFETs, charge balance is the most important issue of the SJ fabrication process. In order to achieve the best electrical characteristics, such as breakdown voltage and on-resistance, the N-type and P-type drift regions must be fully depleted when the drain bias approaches the breakdown voltage, which is known as the charge balance condition. In conventional charge balance analysis, based on multi-epi process SJ MOSFETs, analytical model has only N, P pillar width and doping concentration parameter. But applying a conventional charge balance principle to trench filling process, easier than Multi-epi process, is impossible due to the missing of the trench angle parameter. To achieve much more superior characteristics of on-resistance in trench filling SJ MOFET, the appropriate trench angle is necessary. So in this paper, modulated charge balance analysis is proposed, in which a trench angle parameter is added. The proposed method is validated using the TCAD simulation tool.

4-Channel LED Current Balancing Scheme Using C-Fed Hybrid Quasi-Z-Source Converter (전류형 하이브리드 Quasi-Z-Source 컨버터를 이용한 4-채널 LED 전류 밸런싱 기법)

  • Hong, Daheon;Cha, Honnyong
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.1
    • /
    • pp.66-73
    • /
    • 2021
  • This study presents a novel four-channel light-emitting diode (LED) current balancing topology using a current-fed hybrid quasi-Z-source converter. With the proposed structure, currents flowing through four LED strings are automatically balanced owing to the charge (amp-sec) balance condition on capacitors. Thus, automatic current balancing of the proposed driver is simple and precise. In addition, the proposed LED driver uses only one active switch and three diodes. The operating principle and characteristics of the proposed four-channel LED driver are analyzed in detail. To verify the operation of the proposed LED driver, a prototype is built and tested with different numbers of LEDs.

Nonisolated Multichannel LED Current Balancing Scheme Using Coupled Inductor and Series Resonant Converter (결합인덕터와 직렬 공진을 이용한 비절연 다중 LED 전류 평형 기법)

  • Shin, Yooyong;Hong, Daheon;Choi, Byungcho;Cha, Honnyong
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.4
    • /
    • pp.249-255
    • /
    • 2021
  • A novel current balancing technique for multichannel light-emitting diode (LED) that uses a series resonance and coupled inductor is proposed in this paper. The proposed LED driver balances output currents through frequency control and enables zero-voltage switching. The proposed converter utilizes the charge balance condition of the resonant capacitor and the current sharing function of the coupled inductor to achieve whole LED current balancing without an additional controller. The proposed coupled inductor can integrate the current balancing function and the resonant inductor, so the power density can be increased by reducing the number of magnetic devices. A 40 W prototype is built to verify the validity of this LED driver, and the experimental results are successfully obtained.

New LED Current Balancing Scheme Using C-Fed Z-Source Converter (전류형 Z-Source 컨버터를 이용한 새로운 LED 전류 밸런싱 기법)

  • Hong, Daheon;Cha, Honnyong
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.1
    • /
    • pp.9-15
    • /
    • 2021
  • In multi-string light-emitting diode (LED) driver system, current balancing is crucial because the brightness of LED is directly related to its forward current. This paper presents a novel LED current balancing topology using current-fed Z-source converter. With the proposed structure, currents flowing through two LED strings are automatically balanced owing to the charge-balance condition on capacitors. Operation of the proposed converter is simple and the proposed converter uses only one active switch and one diode. Moreover, low-side gate driving can be used to operate the active switch. To verify the operation of the proposed LED current balancing converter, a prototype is built and tested with different numbers of LEDs.

Development and Evaluation of Body Surface Electric Energy Measurement System for Oriental Medical Diagnosis (한의 진단을 위한 체표에너지 측정 시스템의 개발 및 평가)

  • Kim, Soo-Byung;Kwon, Sun-Min;Kang, Hee-Jung;Yim, Yun-Kyoung;Lee, Yong-Heum
    • Korean Journal of Acupuncture
    • /
    • v.26 no.1
    • /
    • pp.51-60
    • /
    • 2009
  • Objectives : It is considered not easy to diagnose the condition of acupoints or meridians. Oriental Medical instruments have rarely complied with Oriental Medical diagnostic/therapeutic theories. The aim of this study was to develop a system which measures meridian electric potential(MEP) in proportion to bio-electric charge for the purpose of Oriental Medical diagnosis. Method : To evaluate a meridian energy measurement system(MEMS), we carried out a performance test. For significance test, we conducted a clinical trial which measured the MEP of ST36(Chok-samni) on Stomach Meridian(ST). Results & Conclusions : We could evaluate the balance or the imbalance of the MEPs on the left/right ST36. Also, through the comparison of MEPs before and after meals, we could identify the correlation between the MEP and the condition of internal organs. Namely, MEP reflects the condition of acupoints/meridians and internal organs, therefore, we propose this new method for measuring and analyzing the condition of meridians and acupoints for Oriental Medical diagnosis.

  • PDF

Analysis of Meridians Energy change by Cupping Stimulation (부항자극에 대한 체표 경락.경혈의 생체에너지 변화 분석)

  • Kim, Soo-Byeong;Lee, Na-Ra;Kim, Young-Dae;Lim, Jong-Hyeon;Song, Gil-Soo;Jung, Byung-Jo;Lee, Yong-Heum
    • Korean Journal of Acupuncture
    • /
    • v.27 no.4
    • /
    • pp.49-57
    • /
    • 2010
  • Objectives : The aim of this study is evaluation for significance of skin meridian-acupoints energy measurement system, and is verification of principle to measure the bio-ion charge on acupoints. Methods : To check a correlation between the MEP(Meridian Energy Potential) and bio-electric charge condition, ten acupoints(left/right BL meridian : BL13, BL15, BL18, BL20, BL23) were chosen. Based on basic theory concerning the upward trend of the bio-electric charge by cupping therapy, we measured MEP change before and after 600mmHg(80kPa) Negative pressure stimulation using cupping. Results : We could identify the correlation between MEP and the condition of bio-electric charge in acupoints. Also, we checked the balance or imbalance of left/right the MEP and unusual cases. Conclusions : We confirmed significance of proposed principle and meridian energy measurement system.

A Study on the Performance Evaluation of Double-Layered Catayst MEA (이중촉매 MEA의 성능평가에 관한 연구)

  • Kim Hong-Gun;Kang Sung-Soo;Kwac Lee-Ku;Kang Young-Woo
    • New & Renewable Energy
    • /
    • v.2 no.2 s.6
    • /
    • pp.50-59
    • /
    • 2006
  • An experimental and numerical study is carried out to investigate the performance and the efficiency humidifying Membrane Electrolyte Assembly and having the double-layered catalyst in a fuel cell system which is taken into account the physical and thermal concept. Based on the principals of the problem, the equation of electronic charge conservation equation, gas-phase continuity equation, and mass balance equation are used for the numerical calculation. A unit cell for $200cm^2$ MEA is assembled and measured for finding better operational situation. After finding the optimal condition, 10 cell stacked PEMFC is fabricated. For the performance evaluation, V-I and power curves are examined in detail by changing the condition of humidity, temperature, pressure, thickness of catalyst and oxidant. It is found that the power is maximized around 500W at 80A.

  • PDF

A Numerical Solution of Transport of Mono- and Tri-valent Cations during Steady Water Flow in a Binary Exchange System

  • Ro, Hee-Myong;Yoo, Sun-Ho
    • Journal of Applied Biological Chemistry
    • /
    • v.43 no.1
    • /
    • pp.18-24
    • /
    • 2000
  • A one-dimensional transport of displacing monovalent ion, $A^+$, and a trivalent ion being displaced, $B^{3+}^ in a porous exchange system such as soil was approximated using the Crank-Nicolson implicit finite difference technique and the Thomas algorithm in tandem. The variations in the concentration profile were investigated by varying the ion-exchange equilibrium constant (k) of ion-exchange reactions, the influent concentrations, and the cation exchange capacity (CEC) of the exchanger, under constant flux condition of pore water and dispersion coefficient. A higher value of k resulted in a greater removal of the native ion, behind the sharper advancing front of displacing ion, while the magnitude of the penetration distance of $A^+$ was not great. As the CEC increased, the equivalent fraction of $B^{3+}^ initially in the soil was greater, thus indicating that a higher CEC adsorbed trivalent cations preferentially over monovalent ions. Mass balance error from simulation results was less than 1%, indicating this model accounted for instantaneous charge balance fairly well.

  • PDF

A New Current Balancing Operation for LED using Double-Step-Down DC-DC Converter (이중강압 DC-DC 컨버터를 이용한 새로운 LED 전류 밸런싱 기법)

  • Kim, Kisu;Do, Tuan Duc;Cha, Honnyong;Kim, Heung-Geun
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.347-348
    • /
    • 2017
  • This paper presents a new current balancing operation for LED using double-step-down dc-dc converter. The two output currents of the proposed converter can be balanced by charge balance condition although the two output resistances are different. In addition, voltage stresses of the switches of the proposed converter are lower than those of interleaved buck converter. To verify the operation of the proposed converter, simulation program is used.

  • PDF