• Title/Summary/Keyword: Center Fire

Search Result 997, Processing Time 0.026 seconds

An Analysis for the Educational Training Program of Seoul Fire Academy through AHP (AHP를 이용한 서울특별시소방학교 교육훈련프로그램 분석)

  • Kim, Jin Keun;Park, Chan Seok
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.3
    • /
    • pp.121-132
    • /
    • 2014
  • In recent years, the surroundings of Fire have rapidly changed and citizens need for Fire have been demanding very high. Under these situations, in order for satisfaction to all these demands, Seoul Metropolitan Government Fire Academy(SFA) have only to improve its educational training program as the fire educational training center in Korea. The purpose of this study is to scrutinize current educational training program of SFA and measure the relative weight among the hierarchy of disaster management(prevention and mitigation-preparedness-response-recovery) by using the Analytic Hierarchy Process(AHP). The result of this study presents that how many hours must be allocated and set the educational training program with scientific and systematic way of AHP compared the current program of SFA in 2013. And This study is applied to increase access and comprehension about the AHP and will be able to present guideline for the selection of optimal the educational training of SFA to serve Seoul citizens the best Fire services.

Optimum Fire Extinguishing Modeling using Impact Factor Analysis on Water Mist System of Pool Fire (영향인자 분석을 통한 고임화재의 미분무수 최적소화 모델링)

  • Hwang, Won-Jun;Kim, Hwang-Jin;Lee, Sung-Eun;Kim, Sung-Won;Oh, Kyu-Hyung
    • Fire Science and Engineering
    • /
    • v.23 no.5
    • /
    • pp.84-89
    • /
    • 2009
  • In this study, the fire extinguishing experiment was performed using a water mist nozzle with variation of factors which affect on the extinguishing time. The variables were distance from nozzle center to fire location, droplet size, height of nozzle and opening or not. With the experimental data, interaction and sensitivity between factors were analysed with Mini tab and deduce a optimum model of fire extinguishing of water mist system. Based on the experiment and modeling of fire extinguishing with water mist system, the most important factor on extinguishing time is the distance from the center of nozzle to fire and the opening effect was small compare with other factors.

A Study on the Characteristics of Smoke Release for Architectural Surface Materials and Architectural Adhesives (건축용 외장재와 접착제의 발연특성에 관한 연구)

  • Park, Young Ju;Kim, Won Jong;Lee, Hae Pyeong;Yu, Jae Yeol;Yang, Young Suk
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.1
    • /
    • pp.21-24
    • /
    • 2014
  • In this study, we have investigated the maximum smoke density and the initial stage smoke density in order to see the characteristics of smoke release of the architectural surface materials and the architectural adhesives, using smoke density chamber. As a result of the study, polyurethane foam showed the highest smoke density index, 206.55 within 10 min. In the case of the other samples, reinforced styrofoam was followed as 39.90, general styrofoam 33.73, and glass fiber 5.40, respectively. In the intial stage of a fire, it is forecasted actually to give hardship at the clear visibility. In the case of architectural adhesives, the highest ranking was those for windows and doors 509.64, stone 275.63, wood 232.25, tile 18.65, and styrofoam 6.44 were followed, respectively. This result is an early research to show characteristics of smoke release through experiment. However, it is meaningful that this study can be used as a basic for further study on architectural fire hazard prediction.

Localization Strategy of Building Fire Following Earthquake Risk Assessment Method (건축물 지진화재위험도 평가기법의 국산화 전략)

  • Kang, Taewook;Kim, Subin;Kim, Ye-eun;Kang, Jaedo;Kim, Haewon;Shin, Jiuk
    • Journal of Korean Association for Spatial Structures
    • /
    • v.23 no.3
    • /
    • pp.57-69
    • /
    • 2023
  • In this study, in order to establish a strategy for developing an fire following earthquake risk assessment method that can utilize domestic public databases(building datas, etc.), the method of calculating the ignition and fire-spread among the fire following earthquake risk assessment methodologies proposed by past researchers is investigated After investigating and analyzing the methodology used in the HAZUS-MH earthquake model in the United States and the fire following earthquake risk assessment methodology in Japan, based on this, a database such as a domestic building data utilized to an fire following earthquake risk assessment method suitable for domestic circumstances (planned) was suggested.

The Real Fire Test in Bedroom for the Performance Based Fire Design (성능기반 화재안전설계를 위한 침실 공간에서의 실화재 실험)

  • Kim, Hyung-Jun;Kwon, In-Kyu;Kweon, Oh-Sang;Kim, Heung-Youl;Chae, Seung-Un
    • Fire Science and Engineering
    • /
    • v.27 no.6
    • /
    • pp.32-37
    • /
    • 2013
  • For The performance based fire design of the buildings, the fire characteristic such as proceeding and scale of the fire should be figured out but, there is lack of relevant information because of different conditions and difficulties of mock-up test like type of division space, ventilation condition, etc, in buildings. Therefore, in the study, a heal release rate etc, the engineering characteristic data value on the fire is proposed by mock-up fire test for division space in buildings. The mock-up fire test is carried out in a bedroom with 2.4 (L) ${\times}$ 3.6 (W) ${\times}$ 2.4 (H) m model. Initial ignition was started from trash box and the test was carried out for 30 min. As a result of the fire test, flame was broken to outside within 7 min and 50 s after starting the test and the maximum heat release rate was measured as 3,810.6 kW at 9 min and 34 s.

A Study on the Risks Factors of Fire Occurrence and Expansion for Traditional Markets (전통시장 화재 발생 및 확대 위험요인에 관한 연구)

  • Kim, Jung-Gon;Park, Chang-Il;Jung, Jae-Wook;Kim, Seong-Gon
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.1
    • /
    • pp.60-67
    • /
    • 2021
  • Purpose: Traditional markets often have irregular space utilization patterns because the spaces are created and divided as time passed. Internally, there is high risk of fire due to problems such as aging facilities and high-density of stores and externally, there is high risk of fire spread since it is often adjacent to deteriorated residential and commercial facilities. Method: In this paper, on-site investigations were carried out to check fire risk factors and fire spread risk, and fire occurrence and expansion risk factors were investigated for traditional markets in Hwanghak-dong and Dong-daemun by using large-scale fire data from existing traditional markets. Result: As a result of the analysis, there are likely to be various problems such as high fire load and lack of safety awareness due to aging facilities and high-density of stores. In particular, it is necessary to prepare countermeasures because deteriorated residential facilities with narrow alleys around traditional markets have high fire spread. It is situation that while traditional markets mainly are managing for fire and disaster centering on the merchant association, the surrounding residential areas are not properly managed. Conclusion: It is necessary to manage deteriorated residential facilities with traditional markets, also to be linked early warning system and information to evacuate rapidly in case of fire there.

A Comparison on the General Characteristics of Acute Stroke Patients between Fire-Heat and Deficiency of Yin (화열과 음허로 진단된 급성기 뇌질환 환자의 특성 비교 연구)

  • Kim, Hye-mi;Gwak, Ja-young;Cho, Seung-yeon;Shin, Ae-sook;Lee, In-whan;Kim, Na-hee;Na, Byung-Jo;Park, Seong-Uk;Jung, Woo-sang;Mun, Sang-gwan;Park, Jung-mi;Ko, Chang-nam;Cho, Ki-ho;Kim, Young-suk;Bae, Hyung-sup
    • The Journal of the Society of Stroke on Korean Medicine
    • /
    • v.10 no.1
    • /
    • pp.33-39
    • /
    • 2009
  • Objects : This study propose to compare on general characteristics of acute stroke patients between Fire-Heat group and Deficiency of Yin group. Method : We recruited acute stroke patient within 4 weeks after stroke admitted to Department of Internal Medicine of Kyunghee University Oriental Medicial Center, Dongguk University Ilsan Oriental Medical Center, Kyungwon University Songpa Oriental Medical Centar and Kyungwon University Incheon Oriental Medical Center from April 2007 to August 2009. We investigate age, sex, type of stroke, past history, general characteristics, smoking, drinking alcohol, marriage sasang constitution, etc. Result : It was significant different in sex, smoking, dringking alcohol and marriage between Fire-Heat group and Deficiency Yin group. We need more cases for another result that could associate with diagnosis of stroke. Conclusion : We found that Fire heat group was more associated with lifestyle than deficiency yin group. Further study will be needed to analysis for the diagnosis and the treatments of stroke.

  • PDF

Study of Diagnosis Criteria For Fire-Heat Pattern in Stroke Patients (중풍환자의 화열변증 진단 기준에 관한 연구)

  • Kang, Byoung-Kab;Sun, Seung-Ho;Lee, Jeong-Seob;Kim, So-Yeon;Choi, Sun-M;Go, Mi-Mi;Kim, Jeong-Cheol;Bang, Ok-Sun
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.23 no.6
    • /
    • pp.1486-1490
    • /
    • 2009
  • To develop the diagnostic tool for Fire-heat pattern, we analyzed sensitivity and specificity of symptom signs to diagnose the Fire-heat pattern in stroke patients. Korean medicine doctor surveyed Fire-Heat of the symptoms for the Stroke(KSDS) case report form in stroke patients within 1 month of onset. The sensitivity of "more 1/5 in major sings and 2/11 in helpful sings", "more 2/5 in major sings and 2/11 in helpful sings", "more 3/5 in major sings and 2/11 in helpful sings", "more 1/5 in major sings and 3/11 in helpful sings" "more 2/5 in major sings and 3/11 in helpful sings" "more 3/5 in major sings and 3/11 in helpful sings" are respectively 93%, 59%, 33%, 80%, 53%, 32%. The specificity are respectively 93%, 59%, 33%, 80%, 53%, 32%. The sensitivity(59%) and specificity(80%) of "more 2/5 in major sings and 2/11 in helpful sings" that to be implanted.