• Title/Summary/Keyword: Cell scattering

Search Result 213, Processing Time 0.051 seconds

Characteristics of the Nd:YAG laser with stimulated brillouin scattering phase conjugate mirror (유도 브릴루앙 산란 위상공액 거울을 이용한 Nd:YAG 레이저 발진기의 출력특성)

  • 이동원;이성구;박승현;공홍진
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.6
    • /
    • pp.548-553
    • /
    • 2002
  • We have investigated the output characteristics of a Nd:YAG oscillator with a Stimulated Brillouin Scattering phase conjugation mirror (SBS-PCM). FC-75 is used as an SBS gain medium and Cr:YAG (T=50%) as a Q-switcher. The SBS-PCM consists of an SBS-cell and a simple plano-convex focusing lens system. For the case of not using a Q-switcher, an SBS-cell doesn't work as a phase conjugation mirror. For the case of using a Q-switcher, the energy characteristics remains nearly the same whether using the SBS-cell or not using it. The pulse width is reduced from 50 ns to 40 ns by an SBS-PCM. When the SBS-cell is used with a Q- switcher, the SBS-cell works very well as a phase conjugation mirror and its beam-profile is improved dramatically. And in order to explain the progression of beam-profile, we propose a simple model based on the nonlinear reflectivity of the SBS-PCM, whose reflectivity is dependent on the pumping intensity at the focal plane.

STARS: A 3D GRID-BASED MONTE CARLO CODE FOR RADIATIVE TRANSFER THROUGH RAMAN AND RAYLEIGH SCATTERING WITH ATOMIC HYDROGEN

  • Chang, Seok-Jun;Lee, Hee-Won
    • Journal of The Korean Astronomical Society
    • /
    • v.53 no.6
    • /
    • pp.169-179
    • /
    • 2020
  • Emission features formed through Raman scattering with atomic hydrogen provide unique and crucial information to probe the distribution and kinematics of a thick neutral region illuminated by a strong far-ultraviolet radiation source. We introduce a new 3-dimensional Monte-Carlo code in order to describe the radiative transfer of line photons that are subject to Raman and Rayleigh scattering with atomic hydrogen. In our Sejong Radiative Transfer through Raman and Rayleigh Scattering (STaRS) code, the position, direction, wavelength, and polarization of each photon is traced until escape. The thick neutral scattering region is divided into multiple cells with each cell being characterized by its velocity and density, which ensures flexibility of the code in analyzing Raman-scattered features formed in a neutral region with complicated kinematics and density distribution. To test the code, we revisit the formation of Balmer wings through Raman scattering of the far-UV continuum near Lyβ and Lyγ in a static neutral region. An additional check is made to investigate Raman scattering of O vi in an expanding neutral medium. We find a good agreement of our results with previous works, demonstrating the capability of dealing with radiative transfer modeling that can be applied to spectropolarimetric imaging observations of various objects including symbiotic stars, young planetary nebulae, and active galactic nuclei.

Enhancement of Dye-Sensitized Solar Cell Efficiency by Spherical Voids in Nanocrystalline ZnO Electrodes

  • Hieu, Hoang Nhat;Dao, Van-Duong;Vuong, Nguyen Minh;Kim, Dojin;Choi, Ho-Suk
    • Korean Journal of Materials Research
    • /
    • v.24 no.9
    • /
    • pp.458-464
    • /
    • 2014
  • Light scattering enhancement is widely used to enhance the optical absorption efficiency of dye-sensitized solar cells. In this work, we systematically analyzed the effects of spherical voids distributed as light-scattering centers in photoanode films made of an assembly of zinc oxide nanoparticles. Spherical voids in electrode films were formed using a sacrificial template of polystyrene (PS) spheres. The diameter and volume concentration of these spheres was varied to optimize the efficiency of dye-sensitized solar cells. The effects of film thickness on this efficiency was also examined. Electrochemical impedance spectroscopy was performed to study electron transport in the electrodes. The highest power conversion efficiency of 4.07 % was observed with $12{\mu}m$ film thickness. This relatively low optimum thickness of the electrode film is due to the enhanced light absorption caused by the light scattering centers of voids distributed in the film.

Resonance Elastic Scattering and Interference Effects Treatments in Subgroup Method

  • Li, Yunzhao;He, Qingming;Cao, Liangzhi;Wu, Hongchun;Zu, Tiejun
    • Nuclear Engineering and Technology
    • /
    • v.48 no.2
    • /
    • pp.339-350
    • /
    • 2016
  • Based on the resonance integral (RI) tables produced by the NJOY program, the conventional subgroup method usually ignores both the resonance elastic scattering and the resonance interference effects. In this paper, on one hand, to correct the resonance elastic scattering effect, RI tables are regenerated by using the Monte Carlo code, OpenMC, which employs the Doppler broadening rejection correction method for the resonance elastic scattering. On the other hand, a fast resonance interference factor method is proposed to efficiently handle the resonance interference effect. Encouraging conclusions have been indicated by the numerical results. (1) For a hot full power pressurized water reactor fuel pin-cell, an error of about +200 percent mille could be introduced by neglecting the resonance elastic scattering effect. By contrast, the approach employed in this paper can eliminate the error. (2) The fast resonance interference factor method possesses higher precision and higher efficiency than the conventional Bondarenko iteration method. Correspondingly, if the fast resonance interference factor method proposed in this paper is employed, the $k_{inf}$ can be improved by ~100 percent mille with a speedup of about 4.56.

Sound Propagation in 5CB Liquid Crystals Homogeneously Confined in a Planar Cell

  • Ko, Jae-Hyeon;Hwang, Yoon-Hwae;Kim, Jong-Hyun
    • Journal of Information Display
    • /
    • v.10 no.2
    • /
    • pp.72-75
    • /
    • 2009
  • The Brillouin spectrum of 4'-n-pentyl-4-cyano-biphenyl (5CB) liquid crystals homogeneously confined in a planar liquid crystal (LC) cell was measured using a 6-pass tandem Fabry-Perot interferometer. By adopting a special right-angle scattering geometry, the sound velocity of 5CB was estimated from the Brillouin shift without knowing the refractive index. The sound velocity of the longitudinal wave propagating along the direction of the directors aligned parallel to the glass plates of the LC cell was 1784${\pm}$7 m/s at 300 K. The attenuation coefficient $\alpha$ was estimated to be approximately $1.9{\times}10^6m^{-1}$, which is about twice as large as that of the longitudinal sound wave propagating along the direction perpendicular to the directors. The present method may be very useful in the evaluation of the elastic properties of the materials used in display devices, whose refractive indices are not known.

Electro-Optic Characteristics of Polymer Dispersed Liquid Crystal Cell with Transparent State Initially (초기에 투명한 상태인 고분자 분산형 액정셀의 전기 광학 특성)

  • 김미숙;원해경;송성훈;이명훈;이승희
    • Polymer(Korea)
    • /
    • v.28 no.4
    • /
    • pp.298-304
    • /
    • 2004
  • We fabricated a polymer dispersed liquid crystal (PDLC) cell using LC with negative dielectric anisotropy and UV curable monomer exhibiting transparent state initially (called normally transparent (NT)) and studied the electro-optic characteristics. The NT PDLC cell made with the ratio of LC : monomer = 70/30 wt%, curing temperature of 20 $^{\circ}C$ and strong UV intensity of 198 ㎽/$\textrm{cm}^2$ had high contrast ratio and showed good electro-optic characteristics. In this condition, LC is aligned vertically on the substrate due to the vertical alignment layer and the polymer made with the UV exposure does not influence the alignment of the LC much. Therefore, the transmittance at the zero voltage is very high and the scattering state of the cell is good after applying the voltage because LC with negative dielectric anisotropy tries to align perpendicular to the field. And also, the NT PDLC cell showed better viewing angle characteristics than that in the normally scattering (NS) PDLC.

A Theoretical Study of Ultrasound Scattering by Blood (혈액에 의한 초음파 산란의 이론적 고찰)

  • 최재준;홍승홍
    • Journal of Biomedical Engineering Research
    • /
    • v.2 no.1
    • /
    • pp.15-20
    • /
    • 1981
  • In this study, the scattering of ultrasound by blood is theoretically studied. At first, the Chernow equation which represents acoustic propagation inside the region of inhomogenieties is modified to be fitted for blood. Then, scattering amplitude and scattering Cross-section at the far-field region are obtained from this equation. In this case, hemotocrit is assumed to be less than 26 per cent, and the red blood cell is modeled as independent scatterer. This study also develops a practical approximation for the backscattering of periodic sinewave bursts by a volume of randomly distributed scatterers, i.e., whole red blood cells. This expression for the received backscattering ultrasound pressure after the n-th burst of narrowband transducer is obtained from an ideal continuous wave transducer's response.

  • PDF

Synthesis of Titanium Dioxide Nanoparticles with a High Crystalline Characteristics (높은 결정성을 갖는 이산화티탄 나노입자의 합성)

  • Kim, Ki-Chul
    • Journal of Convergence for Information Technology
    • /
    • v.7 no.5
    • /
    • pp.53-58
    • /
    • 2017
  • In the age of oil exhaustion, low cost, semi-transparent solar cell, the dye-sensitized solar cell (DSC) has attracted significant attention since 1991 of $Gr{\ddot{a}}tzel$ report. To enhance the light-harvest capability of the photoelectric electrode, and efficiency of photoelectric transformation of the DSC, scattering layer of various structure have been proposed to photoelectric electrode materials. The scattering center of scattering layer needs the large titanium dioxide nanoparticles of 250 - 300 nm in diameter. In this study, the large sized $TiO_2$ nanocyrstals of around 300 nm were synthesized using the modified sol-gel process. According to the analysis of XRD and TEM, the synthesized $TiO_2$ nanoparticles exhibit single crystals of anatase phase. The optical transmittance of the synthesized titanium dioxide film prepared by spin coating is around 50% at 550 nm. It is suitable for scattering layer as a scattering center, and expected to enhance the efficiency of photoelectric transformation of the DSC.

The Scattering Beam Measurement of the RBC and the Fabrication of the Micro Cell Biochip (적혈구의 산란빔 측정과 마이크로 세포 분석 바이오칩 제작)

  • Byun, In Soo;Kwon, Ki Jin;Lee, Joon Ha
    • Progress in Medical Physics
    • /
    • v.25 no.2
    • /
    • pp.116-121
    • /
    • 2014
  • Next future, The bio technology will be a rapidly developing. This paper is the scattering beam measurement of the red blood cell (RBC) and the fabrication of the micro cell biochip using the bio micro electro mechanical system (Bio-MEMS) process technology. The Major process method of Bio-MEMS technology was used the buffered oxide etchant (BOE), electro chemical discharge (ECD) and ultraviolet sensitive adhesives (UVSA). All experiments were the 10 times according to the process conditions. The experiment and research are required the ultraviolet expose, the micro fluid current, the cell control and the measurement of the output voltage Vpp (peak to peak) waveform by scattering angles. The transmitting and receiving of the laser beam was used the single mode optical fiber. The principles of the optical properties are as follows. The red blood cells were injected into the micro channel. The single mode optical fiber was inserting in the guide channel. The He-Ne laser beam was focusing in the single mode optical fiber. The transmission He-Ne laser beam is irradiating to the red blood cells. The manufactured guide channel consists of the four inputs and the four outputs. The red blood cell was allowed with the cylinder pump. The output voltage Vpp waveform of the scattering beam was measured with a photo detector. The receiving angle of the output optical fiber is $0^{\circ}$, $5^{\circ}$, $10^{\circ}$, $15^{\circ}$. The magnitude of the output voltage Vpp waveform was measured in the decrease according to increase of the reception angles. The difference of the output voltage Vpp waveform is due differences of the light transmittance of the red blood cells.