• Title/Summary/Keyword: Cell area

Search Result 3,142, Processing Time 0.037 seconds

A Study on The Optimum Structure of Dye-sensitized Solar Cell for Upscaling (염료감응형 태양전지의 대면적화를 위한 최적 구조 연구)

  • Seo, Hyun-Woong;Kim, Mi-Jeong;Hong, Ji-Tae;Kim, Hee-Je
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1295-1296
    • /
    • 2007
  • A lot of researches about dye-sensitized solar cell (DSC) are recently being conducted. Because DSC has several advantages to pass the limits of silicon solar cells such as a low manufacturing expense, a simple manufacturing process and its transparency. But most researches on DSC are still conducted about the unit cell and laboratory-centered. That is, present researches on DSC are not practical. Therefore, researches about large area cells and modules have to be prerequisites for DSC to have the practicality. Characteristics of large area DSC are so different from those of small area DSC in aspect of fill factor and efficiency. In this study, we made an experiment on finding suitable size of DSC that has the most effective power according to the variation of active area. In detail, the experiment was conducted about the optimum ratio of length to width and we introduced the ratio of active area to non-active area to find the active area which has the best output. Because small DSC doesn‘t have the best output in comparison with total area of cell although the smaller DSC has the better efficiency. As a result, we achieved the optimum ratio of length to width of 8:3 and active area of $8cm^2$ as the optimum size for upscaling DSC.

  • PDF

On the Dynamic Characteristics of Cell Contact by Analyzing TIRE Images (전반사 형광 이미지 분석을 통한 세포 부착점의 운동 특성에 관한 연구)

  • Lee, Yong-Ku;Jin, Song-Wan;Koo, Sang-Mo;Yoo, Jung-Yul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.3 s.258
    • /
    • pp.380-387
    • /
    • 2007
  • We carried out an image analysis of living cells forming their contacts at the bottom of the cell culturing substrate. In order to visualize the contact area selectively, we adopted total-internal-reflection-fluorescence (TIRF) method, which can illuminate the specimen volume within only several hundred nano-meters above the substrate. From the fluorescent intensity of the TRF image, we could calculate the distance of the cell surface from the substrate. As a result, we visualized the origin of cell contacts, their movements, and the change of cell-contact type from the close-contact into focal-contact with information of its vertical displacement representing the temporal evolution process of the three-dimensional cell-surface-profile near the contact area during this metamorphosis.

Rapid Ecoassessment Technique about Anthropogenic Disturbance Potentiality of Land Use (토지의 훼손 잠재성에 대한 신속한 생태평가기법)

  • 김종원
    • The Korean Journal of Ecology
    • /
    • v.26 no.1
    • /
    • pp.19-22
    • /
    • 2003
  • In order to determine the degree of anthropogenic disturbance potentiality (ADP) of the area a rapid ecoassessment technique was developed on the basis of actual vegetation map. ADP degree of relevant unit cell was computed by using four criteria of land use patterns such as forested area, open water and stream, agricultural area, and urbanized area. Ultimate ADP degree of each cell was obtained by means of direct and indirect computation process. Finally the map of ADP was drawn and analyzed. Vulnerable cell and disturbance nuclei were determined according to disturbance vector which is a kind of potential disturbance pressure of relevant cell influenced by surrounding cell. A case study was accomplished in the Gijang area of Pusan metropolitan city. 973 meshes (500m×500m) were analyzed and a total of 79 meshes were currently threatened. Present technique of rapid ecoassessment was practically useful for diagnosing and planning land use.

MEASURING CROWN PROJECTION AREA AND TREE HEIGHT USINGLIDAR

  • Kwak Doo-Ahn;Lee Woo-Kyun;Son Min-Ho
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.515-518
    • /
    • 2005
  • LiDAR(Light Detection and Ranging) with digital aerial photograph can be used to measure tree growth factors like total height, height of clear-length, dbh(diameter at breast height) and crown projection area. Delineating crown is an important process for identifying and numbering individual trees. Crown delineation can be done by watershed method to segment basin according to elevation values of DSMmax produced by LiDAR. Digital aerial photograph can be used to validate the crown projection area using LiDAR. And tree height can be acquired by image processing using window filter$(3cell\times3cell\;or\;5cell\times5cell)$ that compares grid elevation values of individual crown segmented by watershed.

  • PDF

Modeling and Performance Analysis of Zone-Based Registration Considering Cell by Cell Expansion of Location Area (셀 단위로 증가하는 위치영역을 고려한 영역기준 위치등록의 모형화 및 성능 분석)

  • 김경희;백장현;정호연
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.28 no.3
    • /
    • pp.67-79
    • /
    • 2003
  • An efficient mobility management for mobile stations plays an important role in mobile communication networks. Even though many a mobility management schemes have been proposed, most of mobile communication networks adopt the mobility scheme based on zone-based registration. This paper studies the mobility management scheme that combines zone-based registration and 2-step selective paging. We assume cell by cell registration area, not ring by ring registration area of previous studies, and set up a new mobility model based on 2-dimensional random walk model considering the characteristic of zone-based registration to evaluate its performance exactly. We provide numerical results using proposed model to demonstrate the performance of zone-based registration and 2-step selective paging under various circumstances.

Morphometric Study of the Irradiation Effect on the Cartilage Formation in the Rat Mandibular Condyle (방사선 조사가 백서 하악과두 연골 형성에 미치는 영향에 관한 형태계측학적 연구)

  • Kim Jeong-Hwa;Heo Min-Suk;Lee Sam-Sun;Choi Soon-Chul
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.1
    • /
    • pp.87-103
    • /
    • 1999
  • Purpose: This study was undertaken to quantitatively estimate the degree of the damage and recovery of the irradiated rat condylar cartilage using the Image Analyzer. Materials and Methods: Experimental animals were 16 male rats of the Sprague-Dawley strain at the age of 20 day irradiated with the dose of 10 Gy in their head and neck region. Four rats were sacrificed at the each of the following time intervals - 1, 4, 7 and 14 days, respectively. The same number of control group animals were sacrificed at the each age of 21. 24, 27 and 34 days, respectively. The specimens were stained with 0.5% toluidine blue and examined with light microscope. The condylar cartilage was divided into 4 zones; fibrous zone, proliferating zone, upper hypertrophic zone, and lower hypertrophic zone. And then, the proliferating zone was subdivided into 2 layers - upper and lower layer, and upper and lower hypertrophic zone were subdivided into three layers, respectively - upper, middle and lower layer. With the aid of Image Analyzer, morphometric analysis was performed. The thickness, the numerical density of cells, the cell area density, the extracellular matrix area density, the mean area of single cell, the mean area of extracellular matrix per single cell were measured and analysed. Results: In the experimental group, the thickness of the fibrous zone was slightly increased and that of the proliferating zone and the upper and the lower hypertrophic zone was markedly decreased. With time, the thickness of the fibrous zone was gradually increased and that of the proliferating zone and the upper and the lower hypertrophic zone was steadily in the decreased state. The numerical density of cells of the proliferating zone was increased on post-irradiated 1 day, but decreased after post-irradiated 4 day, and that of the upper hypertrophic zone was decreased. The numerical density of cells of the lower hypertrophic zone was decreased in the early stage and then was decreased or not significantly different from that of the control group with time. In the experimental group, the cell area density of the fibrous zone and the proliferating zone was decreased in the early stage and then gradually increased or not significantly different from that of the control group with time. The cell area density of the upper and the lower hypertrophic zone was varied with time. The extracellular matrix area density value were totally opposite to the cell area density values: The mean area of single cell of the fibrous zone and the proliferating zone was .decreased on post-irradiated 1 day, and increased after post-irradiated 4 day. The mean area of single cell of the upper hypertrophic zone was varied with each layer and time. In the experimental group, the mean area of extracellular matrix per single cell of the fibrous zone was not significantly different with control group, and that of the proliferating zone was decreased on post-irradiated 1 day, and increased after post-irradiated 4 day. The mean area of extracellular matrix per single cell of the lower hypertrophic zone was increased in the early stage. and that of upper hypertrophic zone was varied with each layer and time. Conclusion: The condylar cartilages of rats were affected by irradiation, but the changes were vaned with each layer and time. By morphometric analysis. the changes of the cells of the condylar cartilage of irradiated rat could be calculated quantitatively.

  • PDF

A Study of the Quantitative Relationship of Charge-Density Changes and the Design Area of a Fabricated Solar Cell

  • Jeon, Kyeong-Nam;Kim, Seon-Hun;Kim, Hoy-Jin;Kim, In-Sung;Kim, Sang-Hyun
    • Transactions on Electrical and Electronic Materials
    • /
    • v.12 no.5
    • /
    • pp.204-208
    • /
    • 2011
  • In this paper, the design area of a fabricated solar cell has been analyzed with respect to its charge density. The mathematical calculation used for charge-density derivation was obtained from the 2001 version of a MATHCAD program. The parameter range for the calculations was ${\pm}1{\times}10^{17}cm^{-3}$, which is in the normal parameter range for n-type doping impurities ($7.0{\times}10^{17}cm^{-3}$) and also for p-type impurities ($4.0{\times}10^{17}cm^{-3}$). Therefore, it can be said that the fabricated solar-cell design area has a direct effect on charge-density changes.

The Histological Study about the Effects of Paljeungsan-gagambang on Liver and Epididymal Cell of Rats Fed High Fat Diet (팔정산가감방(八正散加減方)이 고지방식이(高脂肪食餌)를 한 백서(白鼠)의 간(肝) 및 부고환지방조직(副睾丸脂肪組織)에 미치는 영향(影響)에 대한 조직화학적(組織化學的) 연구(硏究))

  • Kim Bong-Hyeon;Kim Sang-Chan;Kim Seon-Hui;Kim Yeon-Byeon
    • Herbal Formula Science
    • /
    • v.6 no.1
    • /
    • pp.141-156
    • /
    • 1998
  • This histological study was performed to investigate the effects of .Paljeungsan-gagambang on the epididymal fat cell size, number and the fat drop area of hepatic lobule of rats fed High Fat Diet. Paljeungsan-gagambang was orally administered to the rats of sample group 26mg per 200g of rat's weight everyday for 4 weeks, and the control group were just fed with equal amount of saline solution. Then they are the epididymal fat cell size, epididymal fat cell numberand fat drop area of hepatic lobule that were measured. The results were summarized as follows; 1. The size of the epididymal fat cell was decreased significantly as compared with the control group. 2. The number of the epididymal fat cells was decreased significantly as compared with the control group in distribution chart classified by cell size 3. The Area(%) of the Fat drops in the hepatic lobule was decreased significantly as compared with the control group. According to the above results, it is considered that Paljeungsan-gagambang have effects on the decrease of the epididymal fat cell size, number and fat drop area of hepatic lobule of rats fed high fat diet; Thus, the adminisrtation of Paljeungsan-gagambang is considered to have an improving effect on obesities and liver diseases caused by high fat diet.

  • PDF

Electron Microscopic Observations of the Effects of Thiocarbanilides(L-1) on Dermatophytes (표재성(表在性) 진균(眞菌)의 Thiocarbanilide(L-1) 처리효과에 대(對)한 전자현미경적(電子顯微鏡的) 관찰(觀察))

  • Koh, Choon-Myung;Kim, Tai-Won;Lew, Joon
    • The Journal of the Korean Society for Microbiology
    • /
    • v.5 no.1
    • /
    • pp.9-18
    • /
    • 1970
  • The present study is of ultra-fine structures of Trichophyton rubrum, Trichophyton mentagrophytes, Microsporum canis and Epidermophyton floccosum by means of electron microscopy and reveals the following. 1. In contrast to the bacteria, the normal fungus contains nuclear membrane, mitochondria, endoplasmic reticulun, distinct cell wall and cell membrane and secretory granules as observed in the higher plants and animals. 2. Thickening of the cell wall, inapparent cell wall, inapparent cell membrane with the appearance of electron thin area(ETA) and increase of inclusions were observed in the L-1 treated groups. 3. Thickening of cell wall and increase of ETA were more apparent in the Epidermophyton floccosum than the other groups. 4. Increase of electron thin area was thought to be associated with autolysis.

  • PDF

A Novel Current Steering Cell Matrix DAC Architecture with Reduced Decoder Area (디코더 면적을 줄이는 새로운 전류구동 셀 매트릭스 DAC 구조)

  • Jeong, Sang-Hun;Shin, Hong-Gyu;Cho, Seong-Ik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.3
    • /
    • pp.627-631
    • /
    • 2009
  • This paper presents a novel current steering cell matrix DAC(digital-to-analog converter) architecture to reduce decoder area. The current cell matrix of a existing architecture is selected by columns and lows thermometer code decoder of input bits. But The current cell matrix of a proposal architecture is divided 2n by the thermometer code decoder of upper input bits and are selected by the thermometer code decoder of middle and lower input bits. Because of this configuration, decoder numbers have increased. But the gate number that composed of decoder has decreased. In case of the designed 8 bit current steering cell matrix DAC, the gate number of decoder has decreased by about 55% in comparison with a existing architecture.