• Title/Summary/Keyword: Cell Capacitance

Search Result 220, Processing Time 0.026 seconds

Soft Error Rate for High Density DRAM Cell (고집적 DRAM 셀에 대한 소프트 에러율)

  • Lee, Gyeong-Ho;Sin, Hyeong-Sun
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.2
    • /
    • pp.87-94
    • /
    • 2001
  • A soft error rate for DRAM was predicted in connection with the leakage current in cell capacitor. The charge in cell capacitor was decreased during the DRAM operation, and soft error retes due to the leakage current were calculated in various operation mode of DRAM. It was found that the soft error rate of the /bit mode was dominant with small leakage current, but as increasing the leakage current memory mode shown the dominant effect on soft error rate. Using the 256M grade DRAM structure it was predicted that the soft error rate was influenced by the change of the cell capacitance, bit line capacitance, and the input voltage sensitivity of sense amplifier, and these results can be used to the design of the optimum cells in the next generation DRAM development.

  • PDF

Effect of MIM and n-Well Capacitors on Programming Characteristics of EEPROM

  • Lee, Chan-Soo;Cui, Zhi-Yuan;Jin, Hai-Feng;Sung, Si-Woo;Lee, Hyung-Gyoo;Kim, Nam-Soo
    • Transactions on Electrical and Electronic Materials
    • /
    • v.12 no.1
    • /
    • pp.35-39
    • /
    • 2011
  • An electrically erasable programmable read-only memory (EEPROM) containing a stacked metal-insulator-metal (MIM) and n-well capacitor is proposed. It was fabricated using a 0.18 $\mu$m standard complementary metal-oxide semiconductor process. The depletion capacitance of the n-well region was effectively applied without sacrificing the cell-area and control gate coupling ratio. The device performed very similarly to the MIM capacitor cell regardless of the smaller cell area. This is attributed to the high control gate coupling ratio and capacitance. The erase speed of the proposed EEPROM was faster than that of the cell containing the MIM control gate.

High Frequency Electroporation-transformation of Coryneform Bacteria Grown in the Medium with Penicillin-G (Penicillin-G 첨가 배지에서 배양한 코리네형 세균의 전기장 충격법에 의한 고효율 형질전환)

  • 노갑수;김성준
    • KSBB Journal
    • /
    • v.6 no.3
    • /
    • pp.223-230
    • /
    • 1991
  • Using the shuttle vector pECCGl between Escherichia coli and Corynebacterium glutamicum and C. glutamicum strain JS231 grown in the medium supplemented with penicillin-G, which inhibits the formation of cross-links in the peptidoglycan of bacterial cell wall, various parameters involved in electroporation system including resistance, electric field strength, capacitance, DNA concentration, and cell density were investigated independently and optimized for the high efficiency transformation of coryneform bacteria. Using cells grown with 0.3U/ml of penicillin-G and harvested at A600 of 0.7-0.8, transformation efficiencies of 107-l08 transformants/$\mu\textrm{g}$ of DNA with Corynebcctertum glutamicum strain JS231 and wild type ATCC13032 were achieved under conditions of 12.5kV/cm of electric field strength, 400 ohms of resistance, $25\mu$F of capacitance, 3$\times$108 cells per transformation(1.2$\times$1010 cells/ml) and 100ng of plasmid DNA per transformation.

  • PDF

Electro-Optical characteristics with dielectric thickness of AC-PDP

  • Jung, K.B.;Choi, J.H.;Kim, S.B.;Jung, Y.;Choi, E.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.768-770
    • /
    • 2003
  • In AC PDP, since charges generated by gas discharge are accumulated on the dielectric. The dielectric is a major factor to determine cell capacitance and its memory effect is a play an important role in PDP driving. In this experiment, we have investigated the electro-optical characteristics with dielectric thickness and we have analyzed wall charge and wall voltage by Q-V energy diagram. The dielectric thickness was varied from 20 um to 50 um. As results, according to the dielectric thickness increase,cell capacitance and power consumption is reduced.

  • PDF

Writable Cholesteric Liquid Crystal Display and the algorithm used to detect its image

  • Lee, Da-Wei;Shiu, Jyh-Wen;Sha, Yi-An;Chang, Yu-Pei
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.356-359
    • /
    • 2007
  • Writable Cholesteric Liquid Crystal Display and the algorithm used to detect its image were developed. We could use any hard tip, ex: the tip of a forefinger, to directly write an image on the surface of Cholesteric Liquid Crystal Display (CHLCD). By measuring the capacitance of one pixel of test cell (12mm x 15mm/1x1), F-state or P-state could be detected. By measuring the capacitance of one pixel of 4.1" CHLCD (241um x 241um/ 320x320), F-state or Pstate could not be detected, due to the effect of parasitic capacitance. Therefore, high frequency measurement and the algorithm were developed to detect the image on CHLCD.

  • PDF

Charge/discharge Properties of $V_2O_5$-AC Composite for Supercapacitor (Supercapacitor용 $V_2O_5$-AC Composite의 충방전 특성)

  • 김명산;김종욱;구할본
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.366-369
    • /
    • 1999
  • The purpose of this study is to research and develop V2Os-AC(activated carbon) composite electrode for supercapacitor. Supaercapacitor cell of V2Os-AC composite electrode with 25P70FLiCIO$_{4}$/PC$_{10}$/EC$_{10}$ polymer electrolyte bring out good capacitor Performance below 3V. The discharge capacitance of V2Os-AC(30:70) composite with 70wt.% AC in 1st and 200th cycles was 9.6 and 8.2 F/g at current density of 1m7/cm2. The capacitance of V$_2$O$_{5}$-AC composite with 70wt.% AC capacitor was larger than that of others. The coulombic efficiency of supercapacitor at discharge process of 1 and 200 cycles were 96 and 100%, respectively. V$_2$O$_{5}$-AC composite supercapacitor with 70wt.% AC content showed good capacitance and stability with cycling.ing.ing.

  • PDF

Study on High Density Activated Carbons for Electrode Materials of Supercapacitor (초고용량 커패시터 전극활성물질용 고밀도 활성탄 제조 및 특성 연구)

  • Roh, Kwang Chul;Park, Jin Bae;Lee, Chul-Tae;Park, Chul Wan
    • Applied Chemistry for Engineering
    • /
    • v.18 no.4
    • /
    • pp.381-385
    • /
    • 2007
  • High density activated carbons electrode materials, for supercapacitor were prepared by chemical KOH activation of cokes as the starting material under Ar atmosphere. By controlling the synthesis conditions and reducing KOH quantity in the activation step, the specific surface area of the product was decreased. BET surface area was measured to be $500{\sim}1260m^2/g$, and the electrode density was in the range of $0.68{\sim}0.83g/cm^3$. Volumetric specific capacitance (unit cell test) was as high as 20 F/cc, which corresponds to gravimetric specific capacitance of about 95 F/cc on the basis of half cell test. It should be noted that the specific capacitance of the activated carbons prepared in this study is superior to that of commercial activated carbons.

A Hybrid Electrochemical Capacitor Using Aqueous Electrolyte (수용성 전해액을 사용하는 하이브리드 전기화학 축전기)

  • Kim, Jong-Huy;Jin, Chang-Soo;Shin, Kyoung-Hee;Lee, Mi-Jung
    • Journal of the Korean Electrochemical Society
    • /
    • v.6 no.2
    • /
    • pp.153-157
    • /
    • 2003
  • A hybrid electrochemical capacitor having both characteristics of electric double layer capacitance and pseudo-capacitance was studied throughout cell tests. Asymmetric electrodes with $Ni(OH)_2/activated$ carbon based positive electrode and activated carbon based negative electrode were used in preparing test cells of $5\times5cm^2$. Cyclic voltammetry measurements and impedance measurements were conducted to understand electrochemical behavior of each electrode. To find an optimal mass ratio of negative to positive electrode, charge-discharge cycle tests were also performed.

MEMS based capacitive biosensor for real time detection of bacterial growth (실시간 박테리아 감지를 위한 정전용량방식의 MEMS 바이오센서)

  • Seo, Hye-Kyoung;Lim, Dae-Ho;Lim, Mi-Hwa;Kim, Jong-Baeg;Shin, Jeon-Soo;Kim, Yong-Jun
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.3
    • /
    • pp.195-202
    • /
    • 2008
  • A biosensor based on the measurement of capacitance changes has been designed and fabricated for simple and realtime detection of bacteria. Compared to an impedance measurement technique, the capacitance measurement can make additional measurement circuits simpler, which improves a compatability for integration between the sensor and circuit. The fabricated sensor was characterized by detecting Escherichia coli(E. coli). The capacitance changes measured by the sensor were proportional to E. coli cell density, and the proposed sensor could detect $1{\times}10^6$ cfu/ml E. coli at least. The real-time detection was verified by measuring the capacitance every 20 minutes. After 7 hours of E. coli growth experiment, the capacitance of the sensor in the micro volume well with $4.5{\times}10^5$ cfu/ml of initial E. coli density increased by 20 pF, and that in another wells with $1.5{\times}10^6$ cfu/ml and $8.5{\times}10^7$ cfu/ml initial E. coli density increased by 56 pF and 71 pF, respectively. The proposed sensor has a possibility of the real-time detection for bacterial growth, and can detect E. coli cells with $1.8{\times}10^5$ cfu in nutrient broth in 5 hours.

Design of a Multiband Frequency Selective Surface

  • Kim, Dong-Ho;Choi, Jae-Ick
    • ETRI Journal
    • /
    • v.28 no.4
    • /
    • pp.506-508
    • /
    • 2006
  • A frequency selective surface (FSS), whose unit cell consists of a ternary tree loop loaded with a modified tripole, is proposed to block multiple frequency bands. Target frequency bands correspond to Korean personal communication services, cellular mobile communication, and 2.4 GHz industrial, scientific, and medical bands. Through the adjustment of inter-element and inter-unit cell gaps, and adjustment of the length of elements, we present an FSS design method that makes the precise tuning of multiple resonance frequencies possible. Additionally, to verify the validity of our approach, simulation results obtained from a commercial software tool and experimental data are also presented.

  • PDF