• Title/Summary/Keyword: Cavity thickness

Search Result 318, Processing Time 0.032 seconds

OPACITY AND MASHING EFFECT OF THE OPAQUE SHADE COMPOSITE RESINS (Opaque shade 복합레진의 opacity와 배경 색상 차단 능력의 평가)

  • Park, Su-Jung;Hwang, Yun-Chan;Oh, Won-Mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.4
    • /
    • pp.356-364
    • /
    • 2007
  • The purpose of this study was to assess the background color-interceptive ability ana opacity of opaque shade composites (Universal composite, Filtek Z350, Charisma, Clearfil ST, Palpaque Estelite, Esthet-X, and Metafil Flo). Twenty four background specimens (diameter 5.5 mm, thickness 3.0 mm) with Root dentin Mustard (Bisco, Schaumburg, IL, USA) were made. The CIE $L^*a^*b^*$ value of background specimens was measured by a spectrophotometer (Spectrolino, GretagMacbeth, Regensdorf, Switzerland). Three specimens in every group were filled on the background specimens. The surface color of samples was measured by a spectrophotometer in 3.0 mm and every thickness to 0.5 mm while grinding. The color difference in the background color along with 3.0 mm specimen gauged the masking effect in each thickness while grinding and polishing. The opacity was calculated in 1 mm thick specimens. The opacity was in the decreasing order of Clearfil ST, Metafil Flo, Filtek Z350, Palpaque Estelite, Universal composite, Charisma, and Esthet-X (p < 0.05). As the thickness get reduced, $L^*$ value showed decreasing, $a^*$ increasing tendency. The surface color difference between pair of the 3.0 mm thick specimen and after grinding in same opaque resin was above 3.3 except Clearfil ST and Metafil Flo. The color difference (${\Delta}E^*$) between pair of background specimen and opaque resin built-up specimen showed more than 10.0 regardless kinds and thickness. The variance in opacity characteristics and color of the opaque composites is dependent upon manufacturer. When using the opaque resin, the optical properties of each material must be considered as well as cavity.

Microanatomy of the Heart-kidney Complex of Tegillarca granosa (Bivalvia: Arcidae) (꼬막 Tegillarca granosa 심신낭복합체의 미세해부학적 특징)

  • Ku, Kayeon;Ju, Sun Mi;Lee, Jung Sick
    • The Korean Journal of Malacology
    • /
    • v.31 no.4
    • /
    • pp.291-298
    • /
    • 2015
  • This study was conducted to provide the microanatomical information of the heart-kidney complex of Tegillarca granosa. The heart-kidney complex was located in the pericardial cavity between the dosal visceral mass and posterior adductor muscle. The heart composed of two atrium and one ventricle. The kidney composed of a pair of left and right. The atrium and ventricle of the heart were composed of the epicardium, myocardium and endocardium. The epicardium of simple epithelial layer composed of cuboidal epithelial cells that had a strong basophilic nucleus located in the center. The myocardium composed of muscle fiber bundles. The myocardium in ventricle was denser than in the atrium. The endocardium of simple epithelial layer composed of squamous epithelial cell that had a strong basophilic nucleus was located in the center. The endocardium thickness of the atrium was $6.04({\pm}2.26){\mu}m$, endocardium thickness of the atrium was $7.36({\pm}3.21){\mu}m$, and appeared to be thicker in the ventricle. The kidney composed of numerous renal tubules. The renal tubule of simple epithelial layer composed of columnar epithelial cell with nucleus located in the basal zone and a number of cytoplasmic granules. The developed striated border was the inner epidermis.

THE EFFECT OF MOISTENING OF ETCHED DENTIN AND ENAMEL SURFACE ON THE MICROLEAKAGE OF COMPOSITE RESINS (복합레진 수복시 상아질 표면 처리가 미세 변연 누출에 미치는 영향에 관한 연구)

  • Jeon, Cheol-Min;Kwon, Hyuk-Choon;Lee, Chung-Sik;Lee, Myung-Jon;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.21 no.1
    • /
    • pp.321-338
    • /
    • 1996
  • The purpose of this study was to evaluate the effect of moistening and air-drying of acid conditioned dentin and enamel on the marginal microleakage. In this study, Class V cavity were prepared on both buccal and lingual surface of sixty extracted human premolars with cementum margin. These specimens were randomly devided into three groups and three dentin adhesives(Scotchbond Multi-Purpose, All bond 2, Prisma Universal Bond 3) were applied to each group. The specimens in each group were subdevided into four groups (Wet/primed, Dry/primed, Wet/not primed, Dry/not primed) and the etched dentin and enamel surface were treated these four surface treatments prior to the placement of a bonding agent or adhesive. Wet/primed group was simply blot-dried with a damp facial tissue before primer placement ; Dry/primed group was air dried for 30 seconds before the placement of a primer ; Wet/not primed group and Dry/not primed group were not primed after blot dried and air dried for 30 seconds each group. The bonding agent and composite resin were applied for each group. All specimens were exposed to 500 cycle of thermal stress. Specimens were placed in a silver nitrate solution and then sectioned buccolingually through the center of the restoration. The dye penetrations of the specimens were observed with a stereo microscope. The statistical test were applied to the results using a one way analysis variance (ANOVA) and Duncan's multiple range test. The aspects of silver ion penetration into the resin/dentin interface were examined under scanning electron microscopy. The results were as follows. 1. In all groups, the enamel margin showed significantly lower leakage value than the cementum margin (p<0.05). 2. Regardless of various surface treatment and dentin adhesives, there was no significant difference at the enamel margins (p>0.05). 3. At the dentin margins, the leakage values of Dry/not primed group showed significantly higher than that of the other groups (p<0.05). The leakage values of Wet/primed group showed significantly lower than that of the other groups, but, there was no significant difference between Wet group and Dry group. 4. There was no significantly difference between the dentin adhesives regarding the surface treatments in all groups(p>0.05). 5. On the backscatterd scanning electron microscopy observation, the penetration of the silver ion occured at the bonding resin/dentin interface. In the Wet/primed group, resindentin hybrid zone and resin penetration into the dentin was observed. The resin tags were compactively formed to a thickness of $3\sim4{\mu}m$ at the upper part of dentinal tubules. In the Dry/primed group, the thickness of the hybrid zone and the diameter, depth of the resin tags diminished. In the Non-primed groups, the hybrid zone was not identified and few resin tag was observed. There was the gap formation in the resin/dentin interface.

  • PDF

The effect of irradiated cancellous human bone on exophytic bone formation in residual ridge of the beagle dog (방사선 조사 망상골이 외방형 골형성에 미치는 영향)

  • Chung, Mi-Hyun;Herr, Yeek;Kwon, Young-Hyuk;Park, Joon-Bong;Chung, Jong-Hyuk
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.4
    • /
    • pp.791-803
    • /
    • 2007
  • The purpose of this study was to evaluate exophytically vertical bone formation in residual ridge of the beagle dog by the concept of guided bone regeneration with a titanium reinforced e-PTFE membrane combined with irradiated cancellous human bone. Twelve male beagle dogs(mean age 1.5 years and mean weight 12kg) were used for this study. The alveolar ridges after extraction of all mandibular premolars were surgically and horizontally removed. At 8 weeks after extractions, full-thickness flap was reflected and cortical bone was removed with round bur and copious irrigation. Rectangular parallelepiped(10mm in length, 5mm in width, and 4mm in height) bended with titanium-reinforced e-PTFE(TR e-PTFE) membrane was placed on the decorticated alveolar ridge, fixed with metal pins and covered with full-thickness flap and assigned as a control group. Test groups ere treated with TR e-PTFE membrane filled with irradiated cancellous human bone. Of twelve beagle dogs, four control dogs and four test dogs without membrane exposure to oral cavity were sacrificed at 8 and 16 weeks respectively. The surgical sites were dissected out, fixed in 4% buffered formaldehyde, dyed using a Villanueva staining technique, and processed for embedding in plastic resin. The cutting and grinding methods were routinely processed for histologic and histomophometric analyis of exophytic bone formation as well as statistical analysis. The results of this study were as follows: 1. Exophytic bone formation in the both of experimental groups was increased respectively after surgery from 23.40% at 8 weeks to 46.26% at 16 weeks in the control groups, from 40.23% at 8 weeks to 47.11% at 16 weeks in the test groups(p<0.05). 2. At 8 weeks after surgery, exophytic bone formation was made 40.23% in the test groups and 33.40% in the control groups. Exophytic bone formation was significantly made in the test group more than in the control group. At 16 weeks after surgery, exophytic bone formation was made 44.11% in the test groups and 46.26% in the control groups. Exophytic bone formation was made in the test groups more than in the control groups, but there was no statistically significant differences. 3. The membrane was fixed with metal pins to closely contact it to the bone surface. So, collapse and deviation of the membrane could be prevented and in growth of connective tissue also could be blocked from the periphery of the membrane. On the basis of these findings, wee suggest that intraoral experimental model for exophytic bone formation may be effective to evaluate the effect of bone graft material. And it indicates that combined use of membrane and ICB graft material is more effective than use of membrane only for exophytic bone formation.

Novel Resectable Myocardial Model Using Hybrid Three-Dimensional Printing and Silicone Molding for Mock Myectomy for Apical Hypertrophic Cardiomyopathy

  • Wooil Kim;Minje Lim;You Joung Jang;Hyun Jung Koo;Joon-Won Kang;Sung-Ho Jung;Dong Hyun Yang
    • Korean Journal of Radiology
    • /
    • v.22 no.7
    • /
    • pp.1054-1065
    • /
    • 2021
  • Objective: We implemented a novel resectable myocardial model for mock myectomy using a hybrid method of three-dimensional (3D) printing and silicone molding for patients with apical hypertrophic cardiomyopathy (ApHCM). Materials and Methods: From January 2019 through May 2020, 3D models from three patients with ApHCM were generated using the end-diastolic cardiac CT phase image. After computer-aided designing of measures to prevent structural deformation during silicone injection into molding, 3D printing was performed to reproduce anatomic details and molds for the left ventricular (LV) myocardial mass. We compared the myocardial thickness of each cardiac segment and the LV myocardial mass and cavity volumes between the myocardial model images and cardiac CT images. The surgeon performed mock surgery, and we compared the volume and weight of the resected silicone and myocardium. Results: During the mock surgery, the surgeon could determine an ideal site for the incision and the optimal extent of myocardial resection. The mean differences in the measured myocardial thickness of the model (0.3, 1.0, 6.9, and 7.3 mm in the basal, midventricular, apical segments, and apex, respectively) and volume of the LV myocardial mass and chamber (36.9 mL and 14.8 mL, 2.9 mL and -9.4 mL, and 6.0 mL and -3.0 mL in basal, mid-ventricular and apical segments, respectively) were consistent with cardiac CT. The volume and weight of the resected silicone were similar to those of the resected myocardium (6 mL [6.2 g] of silicone and 5 mL [5.3 g] of the myocardium in patient 2; 12 mL [12.5 g] of silicone and 11.2 mL [11.8 g] of the myocardium in patient 3). Conclusion: Our 3D model created using hybrid 3D printing and silicone molding may be useful for determining the extent of surgery and planning surgery guided by a rehearsal platform for ApHCM.

Case Study on the Impact-Echo Method for Tunnel Safety Diagnosis (터널 안전진단을 위한 충격반향법 사례 연구)

  • Shin, Sung-Ryul;Jo, Cheol-Hyun
    • Tunnel and Underground Space
    • /
    • v.19 no.1
    • /
    • pp.19-30
    • /
    • 2009
  • For the purpose of determining the thickness of concrete lining and detect of the cavity where may be located behind tunnel lining, IE (Impact-Echo) method it effectively useful in the tunnel safety diagnosis and the quality control during the construction. As a part of case study, we applied IE method to various tunnel structure types such as road tunnel and subway tunnel constructed by NATM (New Austrian Tunnelling Method) and ASSM (American Steel Support Method). As tunnel specifications estimated from this method were compared with coring data, design drawing and other survey results, it was very good agreement with each other. In conclusion, we verified that IE method shows an accurate and reliable result. The conventional interpretation of IE method in frequency domain gives only vertical information at a certain point. However, the interpretation using time-frequency analysis and depth section imaging technique from two dimensional profiling surveys can show more reliable information about structure inside.

Numerical Analysis on Heat Transfer Characteristics of a Heat Pipe Type Solar Thermal Receiver Depending on End Wall Angle Variation (고온 히트파이프식 태양열 흡수기의 후벽 각도 변화에 따른 열전달 특성의 수치해석)

  • Park, Young-Hark;Jung, Eui-Guk;Boo, Joon-Hong;Kang, Yong-Heack
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.226-231
    • /
    • 2008
  • The heat transfer characteristics of a solar high-temperature receiver with heat pipes was investigated by numerical simulation. The concentration ratio of the solar receiver ranges 1000 and the concentrated heat is required to be transported to a certain distance for specific applications. This study deals with internal geometry variation of a solar receiver incorporating high-temperature heat pipe. The isothermal characteristics in the receiver section is of major concern. The diameter of the solar thermal receiver was 120 mm and the length was 400 mm. The angle of receiver end wall was varied between $0^{\circ}$ and $45^{\circ}$. The wall thickness of the heat pipe channel was 4mm and 48 axial channels of the same dimensions were attached to the outer wall of the receiver with even spacing in the circumferential direction. The channels are changed to high-temperature sodium heat pipes. Commercial softwares were employed to deal with the radiative heat transfer inside the receiver cavity and the conduction heat transfer along the channels. The numerical results are compared and analyzed from the view Point of high-temperature solar receiver.

  • PDF

In vivo Optical Coherence Tomography Imaging of the Mesothelium Using Developed Window Models

  • Ahn, Yeh-Chan;Chae, Yu-Gyeong;Hwang, Sang Seok;Chun, Bong-Kwon;Jung, Maan Hong;Nam, Sung Jin;Lee, Hae-Young;Chung, Jae Min;Oak, Chulho;Park, Eun-Kee
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.1
    • /
    • pp.69-73
    • /
    • 2015
  • The mesothelium is an essential lining for maintaining the normal homeostasis of the closed body cavity and a central component of pathophysiologic processes. The mesothelium has been known as the end target for asbestos which induces asbestos-related lung diseases. Malignant mesothelioma (MM) is a rare and fatal neoplasm predominantly due to asbestos exposure. Adaptation of an advanced and reliable technology is necessary for early detection of MM because it is difficult to diagnose this disease in its early stages. Optical coherence tomography (OCT) provides cross-sectional images of micro-tissue structures with a resolution of $2-10{\mu}m$ that can image the mesothelium with a thickness of ${\sim}100{\mu}m$ and, therefore, enable investigation of early development of MM. The mesothelium is typically located at the pleura and tunica vaginalis of the scrotum. In this study, we developed animal window models in the above two anatomical sites to visualize mesothelial layers within the mesothelium. OCT images at the two locations were also acquired.

Color Filter Utilizing a Thin Film Etalon (박막형 에탈론 기반의 투과형 컬러필터)

  • Yoon, Yeo-Taek;Lee, Sang-Shin
    • Korean Journal of Optics and Photonics
    • /
    • v.21 no.4
    • /
    • pp.175-178
    • /
    • 2010
  • A transmission type color filter based on a thin film Ag-$SiO_2$-Ag etalon was proposed and realized in a quartz substrate. The device could acquire infrared suppressed transmission and wide effective area compared to costly e-beam lithography and laser interference lithography. The FDTD method was introduced to take into account the effect of the dispersion characteristics of the silver metal and the thickness thereof. Three different color filters were devised: The cavity length for the red, green and blue filters were 160 nm, 130 nm, and 100 nm respectively, with the metal layer unchanged at 25 nm. The observed center wavelengths were measured at 650 nm, 555 nm, and 480 nm for the red, green, and blue devices; the corresponding bandwidths were about 120 nm, 100 nm, and 120 nm; and the peak transmission for all was ~60%. Finally the relative transmission was measured to decline with the angle of the incident beam with the rate of 1%/degree.

A Study on the Mode Characteristics of CSP-LOC Laser Diode for High Power (고출력 CSP-LOC 레이저 다이오드의 모우드 특성에 관한 연구)

  • Yoon, Seok-Beom;Oh, Hwan-Sool
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.25 no.11
    • /
    • pp.1367-1372
    • /
    • 1988
  • In this paper, we have optimized the computation of the CSP - LOC (Channel Substrate Planar-Large Optical Cavity) structure to design the gith power (Ga, Al) As/GaAs CSP-LOC laser diode. The parameters of the device on the bases of experimental datas include the effects of the various layer thickness, material absorption coefficients, stripe width and so forth. At active layer ($d_2$)=0.08 um with optical layer ($d_3$)=0.5 um and $d_2$ = 0.1 um with $d_3$ = 0.4 um, we find the narrower beam divergence and stable high power in the lowest-order mode without the phenomenon of spatial hole burning. The results of theoretical computation show good agreement with experimental measurements made on LPE grown CSP-LOC. Finally, we developed an practical program and the program is applicable to the CSP-LOC lasers with any materials.

  • PDF