• Title/Summary/Keyword: Cavity design

Search Result 715, Processing Time 0.036 seconds

Design of V-Band Waveguide Slot Sub-Array Antenna for Wireless Communication Back-haul (무선통신 백-홀용 V-밴드 도파관 슬롯 서브-배열 안테나의 설계)

  • Noh, Kwang-Hyun;Kang, Young-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.7
    • /
    • pp.334-341
    • /
    • 2016
  • In this paper, the study of a waveguide aperture-coupled feed-structured antenna has been conducted for the purpose of applying it to a wireless back-haul system sufficient for high-capacity gigabits-per-second data rates. For this study, a $32{\times}32$ waveguide slot sub-array antenna with a corporate-feed structure was designed and produced. Also, this antenna is used at 57 GHz to 66 GHz in the V-band. The construction of the antenna is a laminated form with radiating parts (outer groove and slot, cavity), a coupled aperture, and feeds in each. The antenna was designed with HFSS, which is based on 3D-FEM, produced with aluminum processed by a precision-controlled milling machine, and assembled after a silver-plating process. The measurement result from analysis of the characteristics of the antenna shows that return loss is less than -12 dB, VSWR < 2.0, and a wide bandwidth ranges up to 16%. An overall first side lobe level is less than -12.3 dB, and a 3 dB beam width is narrow at about $1.85^{\circ}$. Also, antenna gain is 38.5 dBi, offering high efficiency exceeding 90%.

Functional Results of Soft Palate Defect Reconstruction using Radial Forearm Free Flap after Tonsil Cancer Surgery (편도암 절제술후 전완유리피판술을 이용한 연구개 결손부 재건의 기능적 결과)

  • Kim, Min-Sik;Sun, Dong-Il;Park, Hae-Sup;Cho, Seung-Ho;Jai, Hyeon-Soon
    • Korean Journal of Bronchoesophagology
    • /
    • v.5 no.2
    • /
    • pp.191-197
    • /
    • 1999
  • Background and Objective : Soft palate plays a great role in function of speech and swallowing. Ablation of tonsil cancer results in multi-demensional defect including soft palate in most cases and restoration of the postoperative oral cavity function is a continuing surgical challenge. Although a variety of techniques are available, radial forearm free flap has been known as an effective method for these defect, which offers a thin, pliable, and relatively hairless skin, and a long vascular pedicle. The aim of the present study is to report the speech and swallowing function test results of our 5 consecutive radial forearm free flaps used for tonsil cancers. Materials and Methods : We reviewed the medical records of 5 patients who were offered intraoral reconstruction with a radial forearm free flap after ablative surgery for tonsil cancers, from Dec. 1997 to Oct. 1998, and analyzed the surgical methods, complications, and speech and swallowing function test results. We have examined with modified barium swallow to evaluate postoperative wallowing function and articulation and resonance test for speech. Results : The tumor sizes by TNM stage(AJCC, 1997) were T1(1), T2(2), and T4(3). The paddles of flaps were tailored in multilobed designs from oval shape to pentalobed design and in variable size from 24$cm^2$ to 108$cm^2$(average size = 78.4$cm^2$), according to the defect after ablation. This procedures resulted in satisfactory flap success and functional results all but 1 case of flap contracture in 2 postoperative week, achieved early oral diet until 16-57 postoperative day(average, 28 days) and social speech. The oropharyngeal defect including soft palate reconstruction with radial forearm free flap might be an excellent method for the maximal functional results, after ablative surgery of tonsil cancer that results in multidimensional defect.

  • PDF

Quantitative analysis of mutans streptococci adhesion to various orthodontic bracket materials in vivo (다양한 교정용 브라켓 원재료에 부착하는 mutans streptococci 양의 비교분석)

  • Yu, Jin-Kyoung;Ahn, Sug-Joon;Lee, Shin-Jae;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.39 no.2
    • /
    • pp.105-111
    • /
    • 2009
  • Objective: To estimate the effects of bracket material type on enamel decalcification during orthodontic treatment, this study analyzed the adhesion level of mutans streptococci (MS) to orthodontic bracket materials in vivo. Methods: Three different types of orthodontic bracket materials were used: stainless steel, monocrystalline sapphire, and polycrystalline alumina. A balanced complete block design was used to exclude the effect of positional variation of bracket materials in the oral cavity. Three types of plastic individual trays were made and one subject placed the tray in the mouth for 12 hours. Then, the attached bacteria were isolated and incubated on a mitis salivarius media containing bacitracin for 48 hours. Finally, the number of colony forming units of MS was counted. The experiments were independently performed 5 times with each of the 3 trays, resulting in a total of 15 times. Mixed model ANOVA was used to compare the adhesion amount of MS. Results: There was no difference in colony forming units among the bracket materials irrespective of jaw and tooth position. Conclusions: This study suggested that the result of quantitative analysis of MS adhesion to various orthodontic bracket materials in vivo may differ from that of the condition in vitro.

Horizontal Consolidation Characteristics of Marine Clay Using Piezocone Test (Piezocone 시험을 이용한 해성점토의 수평압밀 특성 연구)

  • 이강운;윤길림;채영수
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.5
    • /
    • pp.133-144
    • /
    • 2003
  • Horizontal consolidation characteristics of Busan marine clay were investigated by computing coefficient of horizontal consolidation from Piezocone data and comparing their results with those of standard consolidation test. It is well known that current prediction models of $c_h$ for high plastic soils have large uncertainties, and show a great difference between the predicted and the measured values. However, the spherical models and expanding cavity theory of Torstensson(1977), and Burns & Mayne(1998) based on modified Cam-Clay model with critical limit state concepts have relative reliability in estimating $c_h$ and good applicability in highly plasticity soils. In this paper, a normalization technique was used to evaluate $c_h$ using the Burns and Mayne's method based on the dissipation test, and their normalized consolidation curves give 0.015 of time factor($T_{50}$) when 50% degree of consolidation is completed. Comparison study using Piezocone data obtained at other similar ground site shows 1.5 times less systematicality than that of standard consolidation test, which indicates considerable approximation with the measured values because standard consolidation test gives the difference of three to few times compared with the measured values. In addition, design chart for estimating $c_h$ based on the chart from Robertson et al.(1992) and using the other method of the direct prediction from the of dissipation test was newly proposed. It is judged that new proposed chart is very applicable to Korean marine soils, especially in very high plastic soils.

Broadband LTCC Receiver Module for Fixed Communication in 40 GHz Band (40 GHz 대역 고정통신용 광대역 LTCC 수신기 모듈)

  • Kim Bong-Su;Kim Kwang-Seon;Eun Ki-Chan;Byun Woo-Jin;Song Myung-Sun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.10 s.101
    • /
    • pp.1050-1058
    • /
    • 2005
  • This paper presents how to design and implement a very compact, cost effective and broad band receiver module for IEEE 802.16 FWA(Fixed Wireless Access) in the 40 GHz band. The presented receiver module is fabricated in a multi-layer LTCC(Low Temperature Cofired Ceramic) technology with cavity process to achieve excellent electrical performances. The receiver consists of two MMICs, low noise amplifier and sub-harmonic mixer, an embedded image rejection filter and an IF amplifier. CB-CPW, stripline, several bond wires and various transitions to connect each element are optimally designed to keep transmission loss low and module compact in size. The LTCC is composed of 6 layers of Dupont DP-943 with relative permittivity of 7.1. The thickness of each layer is 100 um. The implemented module is $20{\times}7.5{\times}1.5\;mm^3$ in size and shows an overall noise figure of 4.8 dB, an overall down conversion gain of 19.83 dB, input P1 dB of -22.8 dBm and image rejection value of 36.6 dBc. Furthermore, experimental results demonstrate that the receiver module is suitable for detection of Digital TV signal transmitted after up-conversion of $560\~590\;MHz$ band to 40 GHz.

Evaluation of Weathering Intensity and Strength Parameter for Weathered Granite Masses (I) (화강 풍화암의 풍화도 및 강도정수의 평가 (I))

  • 이종규;장서만
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.2
    • /
    • pp.227-236
    • /
    • 2003
  • The evaluation of the reliable strength and deformation characteristics of weathered granite masses is very important for the design of geotechnical structure under working stress conditions. Various types of laboratory test such as triaxial compression test can be performed to determine the strength parameters. However, it is very difficult to obtain the representative undisturbed samples on the site and also the rock specimen cannot represent rock mass including discontinuities, fracture zone, etc. This study aims to investigate the strength and deformation characteristics of granite masses corresponding to its weathering and develop a practical strength parameter evaluation method using the results of PMT. To predict weathering intensity and strength parameters of the weathered granite masess in the field, various laboratory tests and in-situ tests including field triaxial test and PMT are carried out. Based on the results of weathering index tests, the classification method is proposed to identify the weathering degree in three groups for the weathered granite masses. Using the analytical method based on the Mohr-Coulomb failure criteria and the cavity expansion theory, the strength parameters of rock masses were evaluated from the results of PMT. It shows that weathering intensity increases with decreasing the strength parameters exponentially. The strength parameters evaluated with the results of PM almost coincide with the results of field triaxial test.

Flow Visualization in the Branching Duct by Using Particle Imaging Velocimetry (입자영상유속계를 이용한 분기관내 유동가시화)

  • No, Hyeong-Un;Seo, Sang-Ho;Yu, Sang-Sin
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.1
    • /
    • pp.29-36
    • /
    • 1999
  • The objective of this study is to analyse the flow field in the branching duct by visualizing the flow phenomena using the PIV system. A bifurcation model is fabricated with transparent acrylic resin to visualize the whole flow field with the PIV system. Water was used as the working fluid and the conifer powder as the tracer particles. The single-frame and two-frame methods of the PIV system and 2-frame of the grey level correlation method are applied to obtain the velocity vectors from the images captured in the flow filed. The velocity distributions in a lid-driven cavity flow are compared with the so-called standard experimental data, which was obtained from by 4-frame method in order to validate experimental results of the PIV measurements. The flow patterns of a Newtonian fluid in a branching duct were successfully visualized by using the PIV system and the sub-pixel and the area interpolation method were used to obtain the final velocity vectors. The velocity vectors obtained from the PIV system are in good agreement with the numerical results of the 3-dimensional branch flow. The results of numerical analyses and the PIV experiments for the three-dimensional flows in the branch ing duct show the recirculation zone distal to the branching point and the sizes of the recirculation length and height of the tow different methods are in good agreement.

  • PDF

Performance Evaluation of Mid-IR Spectrometers by Using a Mid-IR Tunable Optical Parametric Oscillator (중적외선 광 파라메트릭 발진기를 이용한 중적외선 분광기 성능 평가)

  • Nam, Hee Jin;Kim, Seung Kwan;Bae, In-Ho;Choi, Young-Jun;Ko, Jae-Hyeon
    • Korean Journal of Optics and Photonics
    • /
    • v.30 no.4
    • /
    • pp.154-158
    • /
    • 2019
  • We have used a mid-IR (mid-infrared) continuous-wave (cw) optical parametric oscillator (OPO), developed previously and described in Ref. 12, to build a performance-evaluation setup for a mid-IR spectrometer. The used CW OPO had a wavelength tuning range of $ 2.5-3.6{\mu}m$ using a pump laser with a wavelength of 1064 nm and a fan-out MgO-doped periodically poled lithium niobate (MgO:PPLN) nonlinear crystal in a concentric cavity design. The OPO was combined with a near-IR integrating sphere and a Fourier-transform IR optical spectrum analyzer to build a performance-evaluation setup for mid-IR spectrometers. We applied this performance-evaluation setup to evaluating a mid-IR spectrometer developed domestically, and demonstrated the capability of evaluating the performance, such as spectral resolution, signal-to-noise ratio, spectral stray light, and so on, based on this setup.

A Study on the Development of Bubble Reduction System through Experimentation and Analysis (실험과 해석을 통한 기포저감 시스템의 개발에 대한 연구)

  • Sim, Woo-Bin;Yoo, Young-Cheol;Park, Sung-Young
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.3
    • /
    • pp.197-204
    • /
    • 2021
  • This study relates to a device that increases efficiency by reducing air bubbles in a hydraulic system used in hydraulic machinery. The reverse design and product production of the bubble reduction device, which is a commercial product overseas, was carried out. Overseas commercial products were set as the base model, a rotary rotor and an inclined rotor were added to increase the surface area of the fluid, and an annular equal distribution part with a slot in the lower part was additionally applied to distribute the fluid evenly. In addition, internal flow trends were analyzed and a system that evenly distributes the linear flow of fluid was selected as the first improvement model. Based on the first improvement model, a case where the angle of the inclined rotor is 45° was selected as the second improvement model. Based on this, as a result of setting the exit width of the annular equally distributed part as a variable, the bubble reduction efficiency was highest when the lower slot diameter of the annular part was 10mm. Finally, the system in which the average cross-sectional flow velocity decreased by 147% compared to the Base Model was derived as the final improved model.

Prosthetic rehabilitation by obturator considering the biomechanics in partially edentulous patient after maxillectomy (상악골 절제술을 받은 부분 무치악 환자에서 생역학을 고려해 제작한 구개 폐색장치를 이용한 보철 수복 증례)

  • Lee, Kang-Shin;Park, Ju-Mi;Ahn, Seung-Geun;Seo, Jae-Min;Park, Yeon-Hee;Lee, Jung-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.37 no.4
    • /
    • pp.281-293
    • /
    • 2021
  • Patients who went through maxillectomy can have severely impaired swallowing, mastication, and pronunciation functions because of palatal defects. Leakage occurs through the nasal cavity while eating, chewing becomes difficult due to the loss of teeth and alveolar ridges, and oral and nasal passages are not separated, leading to hyper-nasal sound, and significantly reducing the quality of life. To prosthetically reconstruct the defect, the weight of the obturator should be reduced as much as possible to minimize dropout because of gravity, and the bulb of the obturator should be properly extended into the defect to get additional retention and stability. In this case of a partially edentulous patient who underwent additional maxillary resection because of tumor recurrence, a metal framework was designed by applying the basic design principles of removable partial dentures. An obturator with improved retention, stability, and support was fabricated through functional impressions. The patient was satisfied with the improved facial expression, mastication, swallowing, and pronunciation, and showed stable occlusion and oral hygiene management during the follow-up period.